1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Expression of severe fever with thrombocytopenia syndrome virus Gn-D Ⅲ-Ⅲ and development of indirect ELISA for antibody detection
Mengyao ZHANG ; Tianlai LIANG ; Feihu YAN ; Tao CHEN ; Cuicui JIAO ; Hongli JIN ; Jiaoyan LUAN ; Xiao WU ; Pei HUANG ; Haili ZHANG ; Qin NING ; Hualei WANG ; Yuanyuan LI
Chinese Journal of Veterinary Science 2024;44(8):1704-1712
The PCR-amplified severe fever with thrombocytopenia syndrome virus(SFTSV)Gn-DⅢ-Ⅲ gene was inserted into the pET-30a(+)prokaryotic expression vector to generate the re-combinant plasmid pET-SFTSV-Gn-D Ⅲ-Ⅲ.The plasmid was transformed into E.coli BL21(DE3)for Gn-DⅢ-m protein expression and the expression conditions were optimized.The Gn-DⅢ-Ⅲ protein purified with Ni-NTA column affinity chromatography was applied as the captured antigen to establish an indirect ELISA method for the detection of SFTSV antibody.The results demonstrated that the recombinant plasmid pET-SFTSV-Gn-D Ⅲ-Ⅲ was successfully constructed as identified by PCR and sequencing.The recombinant protein SFTSV Gn-D m-Ⅲ was soluble ex-pression in E.coli under the optimal induction conditions of 0.4 mmol/L IPTG at 25 ℃ for 4 h,and the protein purity was 91.77%after purification by Ni-NTA column.The optimal reaction con-ditions for the indirect ELISA of SFTSV antibody were as follows:coating antigen concentration(5 μg/mL),primary antibody(incubation at 37 ℃ for 1.5 h),and secondary antibody(diluted 1:10 000 and incubated at 37 ℃ for 1 h).The established method had no cross-reactivity with Rift Valley fever virus(RVFV),Ebola virus(EBOV),and tick-borne encephalitis virus(TBEV)posi-tive sera.The method had a high sensitivity,with P/N>2.1 for SFTSV-positive sera diluted to 81920.Coefficients of variation for intra-and inter-batch reactions were less than 10%.Detection of four SFTSV-infected human clinical serum samples showed the serum samples from patients in re-mission were tested as positive(P/N>2.1),while serum samples from patients with multiple or-gan failure were detected as negative(P/N<2.1).The results indicated that the SFTSV Gn-D Ⅲ-Ⅲ protein was successfully expressed and purified,and it was used as the coating protein to estab-lish an indirect ELISA assay for SFTSV antibody,which possesses good specificity,sensitivity and reproducibility.This method might be applied to detect human SFTSV clinical serum samples.
7.The Effects of RNF213 on the Proliferation and Apoptosis of Acute Myeloid Leukemia THP-1 Cells
Xiao-Qi SHI ; Ping-Ping ZHANG ; Ya-Ning GUAN ; Zuo-Chen DU ; Yan CHEN ; Pei HUANG ; Zhi-Xu HE
Journal of Experimental Hematology 2024;32(5):1365-1371
Objective:To discover the relationship between the RNF213 gene and acute myeloid leukemia(AML),and explore the effect of RNF213 on the proliferation and apoptosis of THP-1 cells.Methods:Analyze the expression of RNF213 gene in AML and its relationship with prognosis through the GEPIA database.Collecting 30 AML patients and non-tumor hematological patients who went to the Affiliated Hospital of Zunyi Medical University from January 2017 to January 2022.RT-qPCR and Western blot were used to detect the expression levels of RNF213 mRNA and protein.Perform survival of patients was analysed by Kaplan-Meier.Meanwhile,the expression levels of RNF213 mRNA and protein were detected in AML cell lines(THP-1,OCI-AML2).CRISPR-Cas9 was used to knockdown the RNF213 gene in THP-1 cells;flow cytometry was used to detect apoptosis rate of cell.CCK-8 and colony formation assay were used to detect cell proliferation.Western blot was used to detect the expression level of Cleaved-Caspase 3 protein.Results:Compared with the control group,the expression level of RNF213 in AML patients was significantly increased,and patients with high expression of RNF213 have a worse prgnosis.Higher expression level of RNF213 protein in THP-1 cells.After knocking down the RNF213 gene of THP-1 cells,cell proliferation was significantly reduced,and the apoptosis rate and expression of apoptosis related protein Cleared-Caspase3 were significantly increased.Conclusion:AML patients have high expression of RNF213,and the prognosis of high expression patients is poor.The RNF213 gene affects AML cell proliferation and apoptosis,and may be a prognostic marker and potential therapeutic target for AML.
8.Chemical derivatization strategies for enhancing the HPLC analytical performance of natural active triterpenoids
Huang XIAO-FENG ; Xue YING ; Yong LI ; Wang TIAN-TIAN ; Luo PEI ; Qing LIN-SEN
Journal of Pharmaceutical Analysis 2024;14(3):295-307
Triterpenoids widely exist in nature,displaying a variety of pharmacological activities.Determining triterpenoids in different matrices,especially in biological samples holds great significance.High-performance liquid chromatography(HPLC)has become the predominant method for triterpenoids analysis due to its exceptional analytical performance.However,due to the structural similarities among botanical samples,achieving effective separation of each triterpenoid proves challenging,necessitating significant improvements in analytical methods.Additionally,triterpenoids are characterized by a lack of ultraviolet(UV)absorption groups and chromophores,along with low ionization efficiency in mass spectrometry.Consequently,routine HPLC analysis suffers from poor sensitivity.Chemical derivatization emerges as an indispensable technique in HPLC analysis to enhance its performance.Considering the structural characteristics of triterpenoids,various derivatization reagents such as acid chlorides,rho-damines,isocyanates,sulfonic esters,and amines have been employed for the derivatization analysis of triterpenoids.This review comprehensively summarized the research progress made in derivatization strategies for HPLC detection of triterpenoids.Moreover,the limitations and challenges encountered in previous studies are discussed,and future research directions are proposed to develop more effective derivatization methods.
9.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
10.Survey on the basic situation and quality safety of radiation therapy in Hunan province
Biao ZENG ; Shixiong HUANG ; Xiangshang SUN ; Songhua YANG ; Qianxi NI ; Pei YANG ; Xuelian XIAO ; Gang HUANG ; Yaqian HAN ; Yingrui SHI
Chinese Journal of Radiation Oncology 2024;33(6):499-505
Objective:To investigate the current status and quality and safety of radiation therapy resources in medical institutions in Hunan province.Methods:The basic situation questionnaire, quality and safety self-assessment form were designed according to the content of the survey, distributed and recovered through the network, and the survey was conducted on all medical institutions (excluding military hospitals) conducting radiotherapy in Hunan province in 2022, and the quality and safety evaluation was checked by the Hunan Radiotherapy Quality Control Center using stratified sampling field inspection. The differences between the self-evaluation scores of radiotherapy quality and safety and the on-site inspection scores of each unit was compared using Wilcoxon test.Results:By the end of 2022, there were 76 medical institutions (excluding military hospitals) conducting radiotherapy in Hunan province, including 62 tertiary hospitals and 14 secondary hospitals, with a total of 44 253 radiotherapy patients admitted annually. The total number of personnel engaged in radiotherapy was 1 381, including 746 physicians, 205 physicists, 397 technicians and 33 maintenance engineers. There were a total of 88 accelerators (including 3 tomotherapy units), 10 gamma knives, and 28 rear-loading machines, with 1.33 gas pedals per million population. There were 36 units that were carrying out three-dimensional conformal technology, 60 static intensity modulation technology, 20 volumetric rotational intensity modulation, 27 stereotactic radiotherapy, 44 image-guided radiotherapy, 33 respiratory motion management, and 27 rear-loading radiotherapy. In the quality and safety evaluation situation, the basic requirements of radiotherapy specialty scored high, with 2 units achieving full marks and no failing units. Radiotherapy personnel and organization, radiotherapy process, documentation record score and other aspects of no full-score units, the score was concentrated in 60~<80 points, and all have part of the unit failed.Conclusions:The radiotherapy industry in Hunan province has been developed steadily in recent years in general, and the structure of radiotherapy personnel tends to be reasonable, but there still exists uneven distribution of radiotherapy resources, poor utilization of equipment in some areas, and inadequate development of technology. The overall quality and safety evaluation are good, but there are still many deficiencies in the organizational requirements of radiotherapy personnel, process requirements and documentation, which need to be continuously optimized and improved in the future, and at the same time, field inspections will be intensified to ensure the quality and safety of radiotherapy.