1.Genetic analysis and reproductive intervention for 46 Chinese pedigrees affected with Hereditary multiple exostoses.
Lilan SU ; Xiao HU ; Jing DAI ; Zhengxing WAN ; Duo YI ; Shuangfei LI ; Liang HU ; Yueqiu TAN ; Fei GONG ; Ge LIN ; Guangxiu LU ; Qianjun ZHANG ; Juan DU ; Wenbin HE
Chinese Journal of Medical Genetics 2026;43(4):253-258
OBJECTIVE:
To explore the genetic etiology of 46 Chinese pedigrees affected with Hereditary multiple exostoses (HME) and provide genetic counseling and reproductive intervention.
METHODS:
Whole-exome sequencing and Sanger sequencing were carried out on 87 patients from the 46 pedigrees to analyze the variants of EXT1 and EXT2 genes. Pathogenicity of the variants was assessed based on the guidelines from the American College of Medical Genetics and Genomics and Association for Molecular Pathology (ACMG/AMP). Prenatal diagnosis and preimplantation genetic testing (PGT) were provided for couples with identified pathogenic mutations. This study was approved by the Medical Ethics Committee of the hospital (Ethics No.: LL-SC-SG-2014-010).
RESULTS:
In total 17 and 22 pathogenic variants were respectively identified in the EXT1 and EXT2 genes, among which 5 EXT1 and 12 EXT2 variants were unreported previously. Three patients with no family history were found to harbor de novo variants of the EXT1 gene. Twenty nine couples had opted for PGT or underwent prenatal diagnosis following natural conception, and 17 healthy babies were born.
CONCLUSION
This study has clarified the genetic etiology of 45 HME pedigrees and identified 17 novel variants, which has enriched the mutational spectrum of the EXT1 and EXT2 genes. Reproductive intervention through PGT and prenatal diagnosis have prevented the recurrence of HME in these families.
Humans
;
Female
;
Male
;
Pedigree
;
Exostoses, Multiple Hereditary/diagnosis*
;
N-Acetylglucosaminyltransferases/genetics*
;
Adult
;
Exostosin 1
;
Asian People/genetics*
;
Genetic Testing
;
Exostosin 2
;
Mutation
;
China
;
Prenatal Diagnosis
;
Pregnancy
;
Genetic Counseling
;
Preimplantation Diagnosis
;
Exome Sequencing
;
East Asian People
2.Laboratorydiagnosis and perinatal blood management of HDFN in a Jr(a-) pregnant woman
Pan XIAO ; Ke SONG ; Wei YANG ; Lingling LI ; Yi LIU ; Chunya MA ; Yang YU
Chinese Journal of Blood Transfusion 2026;39(2):248-255
Objective: To report the antibody identification, blood management during pregnancy and the monitoring process of fetal hemolytic disease of fetus and newborn (HDFN) in a pregnant woman with a history of blood transfusion and pregnancy who developed anti-Jr
. Methods: Saline tube technique and anti-human globulin technique were used for maternal blood typing, unexpected antibody screening and identification, as well as for determining antibody titer and IgG subclasses. PCR-SSP was employed for genotyping of 18 blood group systems. Next-generation sequencing (NGS) was utilized for gene sequencing of 38 blood group systems. Sanger sequencing was applied to verify rare blood group mutations detected by NGS and to investigate the corresponding rare blood group genes in family members. Blood preparation was achieved through anemia management in prenatal clinics and autologous blood collection during pregnancy. The newborn underwent the three primary tests for HDFN and plasma IgG subclass testing. Results: The pregnant woman's blood type was B, RhD positive, with a positive unexpected antibody screen, and the antibody identification pattern was consistent with a high-frequency antigen antibody. Gene sequencing revealed a homozygous ABCG2 c.376C>T mutation in the woman, resulting in the Jr(a-) phenotype, and anti-Jr
antibody was present in her plasma. No compatible Jr(a-) blood was found among family members. The maternal anti-Jr
IgG titer remained stable at 256 during pregnancy, with no detectable IgG1 or IgG3 subclasses against the Jr
antigen. A total of 800 mL of autologous blood was collected in two stages during pregnancy. The newborn was B, RhD positive, Jr(a+), with a positive unexpected antibody screen (anti-Jr
). IgG subclass typing detected no IgG1 or IgG3. The direct antiglobulin test was positive, while the acid elution test was negative. Conclusion: The combination of serology and blood group genetic analysis provides a diagnostic basis for identifying antibodies to high-frequency antigens. Managing perinatal anemia and implementing staged autologous blood storage can secure blood supply for the perioperative period. IgG antibody subclass typing offers a reference for clinical assessment and prevention of HDFN.
3.Construction of Saikosaponin D Multifunctional Liposomes and Evaluation of Its Anti-liver Cancer Efficacy and Targeting
Kun YU ; Guochun YANG ; Yaliang JIANG ; Yunting XIAO ; Congxian WANG ; Qionge SUN ; Ziyue LI ; Yikun SHANG ; Yu MAO ; Xin CHENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(9):205-216
ObjectiveTo construct a multifunctional liposomal delivery system by replacing cholesterol(Chol) in conventional liposomes with saikosaponin D(SSD) and modifying with poloxamer 407(P407) for co-delivery of curcumin(Cur). The system was evaluated for in vivo tumor targeting and inhibitory effects on mouse subcutaneous solid tumors. MethodsSingle-factor and orthogonal tests combined with information entropy weighting were used to optimize the formulation process of the liposome with encapsulation efficiency and absolute Zeta potential as indexes, and validation studies and liposomal characterization were performed. A subcutaneous solid tumor model was established by injecting H22 hepatocellular carcinoma cells subcutaneously into the dorsal surface of the right forelimb of mice. DiR-loaded traditional Chol liposomes(P407-DiR-Chol-LPs, PDCL) and novel SSD-based liposomes(P407-DiR-SSD-LPs, PDSL) were prepared by the optimized formulation process, and tail vein injection was performed to investigate the impact of SSD on liposome tumor targeting with small animal in vivo imaging. Mice were randomly divided into eight groups, including blank group, model group, free doxorubicin(DOX) group(2 mg·kg-1), free Cur group(8 mg·kg-1), free SSD group(10 mg·kg-1), P407-Cur-Chol-LPs(PCCL) group, P407-SSD-LPs(PSL) group, and P407-Cur-SSD-Lps(PCSL) group. Treatments were administered intraperitoneally every other day for seven doses. Antitumor efficacy and biocompatibility were evaluated by monitoring body weight change, organ indices, tumor volume and mass, relative tumor proliferation rate(T/C), and tumor growth inhibition rate(TGI). Histopathological analysis of liver, kidney, and tumor tissues was performed using hematoxylin-eosin(HE) staining. Serum levels of aspartate aminotransferase(AST), alanine aminotransferase (ALT), blood urea nitrogen(BUN), and creatinine(Crea)in mice were quantified by fully automated biochemical analyzer. ResultsOrthogonal test yielded optimal ratios of Cur, SSD, and P407 to soybean phosphatidylcholine(SPC) as 1∶25, 1∶20, and 1∶4. The optimized PCSL exhibited spherical morphology with a particle size of 179.15 nm, a Zeta potential of -47.25 mV, and an encapsulation efficiency of 96.40%. Its in vitro release profile conformed to first-order kinetics, demonstrating excellent storage stability and hemocompatibility. In vivo imaging revealed that the fluorescence signal in tumor tissues and the fluorescence intensity ratio between tumors and organs were significantly higher in the PDSL group than in the PDCL group(P<0.05, P<0.01). Among the treatment groups, PCSL group showed superior efficacy over free Cur group, free SSD group, PCCL group, and PSL group, with TGI>40% and T/C<60%, indicating pronounced anti-hepatocellular carcinoma effects(P<0.05, P<0.01). Histopathology and serum biochemistry indicated minimal hepatorenal toxicity and improved hepatic and renal function in PCSL-treated mice. ConclusionReplacing Chol with SSD in preparing multifunctional drug delivery systems not only stabilizes liposomes but also yields superior anti-hepatocellular carcinoma efficacy, achieving the effect of drug-excipient integration. Co-delivery of Cur via this system can be used for treating subcutaneous solid tumors in hepatocellular carcinoma, providing new insights and technical approaches for anti-hepatocellular carcinoma research and the meridian-guiding and messenger-directing theory in traditional Chinese medicine.
4.Expert consensus on clinical application of parenteral direct thrombin inhibitors in perioperative period
Mingyu JIANG ; Yuan BIAN ; Lizhu HAN ; Qinan YIN ; Fengjiao KANG ; Anhua WEI ; Danjie ZHAO ; Lin WANG ; Ying SHAO ; Li TANG ; Yi WANG ; Shuhong LIANG ; Huijuan LIU ; Guirong XIAO ; Yue LI
China Pharmacy 2026;37(6):689-699
OBJECTIVE To form an expert consensus on the clinical application of parenteral direct thrombin inhibitors (DTIs) in patients during the perioperative period. METHODS Led by Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital (the Affiliated Hospital of UESTC), a multidisciplinary working group was established. Through literature review and the Delphi method, clinical questions related to the rational perioperative use of parenteral DTIs were identified. A structured design was adopted using the “Population-Intervention-Comparison-Outcome” framework; systematic searches were conducted in CNKI, Medline, Embase and other databases. Relevant evidence from randomized controlled trials and cohort studies was included and synthesized. Evidence quality was assessed using the Grades of Recommendations Assessment,Development and Evaluation (GRADE) approach, and recommendations were formulated through multiple rounds of Delphi surveys and expert consensus meetings. RESULTS &CONCLUSIONS Seven recommendations (each with an expert consensus rate exceeding 90%) on the use of parenteral DTIs in perioperative patients were developed. These recommendations specify drug selection, dosing ranges, key monitoring points, and safety management strategies for parenteral DTIs in various scenarios, including the perioperative period of ventricular assist device implantation, the perioperative period of cardiac surgery, perioperative patients with lower-extremity atherosclerotic disease, the perioperative period of percutaneous coronary intervention in patients with acute coronary syndrome, the perioperative period of carotid artery stenting in patients with carotid stenosis, the perioperative period of patients with right heart thrombosis, and patients who develop related thrombosis and dysfunction after a central venous catheter insertion. In addition, warning and management pathways for perioperative bleeding and thrombotic events were proposed. This expert consensus, which is formulated based on the best available evidence, provides evidence-based guidance for standardized and individualized use of parenteral DTIs in perioperative period.
5.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
6.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
7.Olfactory Receptors Expressed in The Intestine and Their Functions
Pei-Wen YANG ; Meng-Meng YUAN ; Ying ZHOU ; Peng LI ; Gui-Hong QI ; Ying YANG ; Zhong-Yi MAO ; Meng-Sha ZHOU ; Xiao-Shuang MAO ; Jian-Ping XIE ; Yi-Nan YANG ; Shi-Hao SUN
Progress in Biochemistry and Biophysics 2026;53(3):534-549
Olfactory receptors (ORs) form the largest superfamily of G protein-coupled receptors (GPCRs). Traditionally recognized for their role in the nasal olfactory epithelium, where they mediate the sense of smell, accumulating evidence has firmly established their ectopic expression in non-olfactory tissues, including the intestine, lungs, and kidneys. The intestine, as the primary site for nutrient digestion and absorption, harbors a highly complex chemical environment. To adapt to this environment, the gut employs a sophisticated network of “chemosensors” to monitor luminal contents and maintain homeostasis. Among these sensors, intestinal ORs have emerged as crucial functional components, serving as a molecular bridge that connects environmental chemical signals—such as food-derived odorants—to specific physiological responses. This discovery has significantly deepened our understanding of how dietary flavors and compounds influence intestinal physiology at the molecular level. This review systematically summarizes the expression profiles, ligand classification, and biological functions of ORs within the gastrointestinal tract. Studies indicate that intestinal ORs exhibit distinct spatial distribution patterns across different gut segments and display cell-type specificity, particularly within enterocytes and enteroendocrine cells. These receptors function as versatile sensors capable of recognizing a wide variety of ligands, including exogenous dietary components, gut microbiota metabolites such as short-chain fatty acids, and endogenous small molecules like azelaic acid. Upon activation by specific ligands, intestinal ORs trigger intracellular signaling cascades, primarily involving the AC-cAMP-PKA pathway or calcium influx channels. A major focus of this review is to elucidate the molecular mechanisms by which these receptors regulate the secretion of gut hormones. Activation of specific ORs in enteroendocrine cells has been shown to stimulate the release of hormones such as glucagon-like peptide-1 (GLP-1), peptide YY (PYY), and serotonin (5-HT), thereby modulating systemic energy metabolism, glucose homeostasis, and gastrointestinal motility. Furthermore, the review addresses the critical roles of ORs in immune regulation and pathology. Evidence suggests that specific ORs contribute to the maintenance of intestinal immune homeostasis and may offer protection against inflammation. Beyond their involvement in inflammatory responses, ORs such as Olfr78 have been shown to regulate the differentiation and function of intestinal endocrine cells. Similarly, Olfr544 has been demonstrated to alleviate intestinal inflammation by remodeling the gut microbiome and metabolome. These findings collectively suggest that specific ORs hold promise as therapeutic targets for mitigating intestinal inflammation and maintaining gut homeostasis. Additionally, the review explores the emerging role of ORs in cancer. Although OR expression is often downregulated in tumor tissues compared to normal mucosa, activation of specific ORs by certain ligands can inhibit tumor cell proliferation and migration and induce apoptosis via pathways such as MEK/ERK and p38 MAPK. Conversely, other receptors, such as OR7C1, may serve as biomarkers for cancer-initiating cells. In conclusion, intestinal ORs represent a vital component of the gut’s sensory network. The review also discusses the translational potential of these findings. By elucidating the precise pairing relationships between dietary components and specific ORs, novel therapeutic strategies could be developed. Intestinal ORs may thus emerge as promising targets for nutritional and pharmacological interventions in metabolic diseases, inflammatory bowel diseases, and malignancies.
8.Rapid Identification of Different Parts of Nardostachys jatamansi Based on HS-SPME-GC-MS and Ultra-fast Gas Phase Electronic Nose
Tao WANG ; Xiaoqin ZHAO ; Yang WEN ; Momeimei QU ; Min LI ; Jing WEI ; Xiaoming BAO ; Ying LI ; Yuan LIU ; Xiao LUO ; Wenbing LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):182-191
ObjectiveTo establish a model that can quickly identify the aroma components in different parts of Nardostachys jatamansi, so as to provide a quality control basis for the market circulation and clinical use of N. jatamansi. MethodsHeadspace solid-phase microextraction-gas chromatography-mass spectrometry(HS-SPME-GC-MS) combined with Smart aroma database and National Institute of Standards and Technology(NIST) database were used to characterize the aroma components in different parts of N. jatamansi, and the aroma components were quantified according to relative response factor(RRF) and three internal standards, and the markers of aroma differences in different parts of N. jatamansi were identified by orthogonal partial least squares-discriminant analysis(OPLS-DA) and cluster thermal analysis based on variable importance in the projection(VIP) value >1 and P<0.01. The odor data of different parts of N. jatamansi were collected by Heracles Ⅱ Neo ultra-fast gas phase electronic nose, and the correlation between compound types of aroma components collected by the ultra-fast gas phase electronic nose and the detection results of HS-SPME-GC-MS was investigated by drawing odor fingerprints and odor response radargrams. Chromatographic peak information with distinguishing ability≥0.700 and peak area≥200 was selected as sensor data, and the rapid identification model of different parts of N. jatamansi was established by principal component analysis(PCA), discriminant factor alysis(DFA), soft independent modeling of class analogies(SIMCA) and statistical quality control analysis(SQCA). ResultsThe HS-SPME-GC-MS results showed that there were 28 common components in the underground and aboveground parts of N. jatamansi, of which 22 could be quantified and 12 significantly different components were screened out. Among these 12 components, the contents of five components(ethyl isovalerate, 2-pentylfuran, benzyl alcohol, nonanal and glacial acetic acid,) in the aboveground part of N. jatamansi were significantly higher than those in the underground part(P<0.01), the contents of β-ionone, patchouli alcohol, α-caryophyllene, linalyl butyrate, valencene, 1,8-cineole and p-cymene in the underground part of N. jatamansi were significantly higher than those in the aboveground part(P<0.01). Heracles Ⅱ Neo electronic nose results showed that the PCA discrimination index of the underground and aboveground parts of N. jatamansi was 82, and the contribution rates of the principal component factors were 99.94% and 99.89% when 2 and 3 principal components were extracted, respectively. The contribution rate of the discriminant factor 1 of the DFA model constructed on the basis of PCA was 100%, the validation score of the SIMCA model for discrimination of the two parts was 99, and SQCA could clearly distinguish different parts of N. jatamansi. ConclusionHS-SPME-GC-MS can clarify the differential markers of underground and aboveground parts of N. jatamansi. The four analytical models provided by Heracles Ⅱ Neo electronic nose(PCA, DFA, SIMCA and SQCA) can realize the rapid identification of different parts of N. jatamansi. Combining the two results, it is speculated that terpenes and carboxylic acids may be the main factors contributing to the difference in aroma between the underground and aboveground parts of N. jatamansi.
9.Minimally invasive therapy for new-onset or residual aortic arch pathology after ascending aortic replacement
Yi XIE ; Peng YANG ; Hongwei ZHANG ; Chen LU ; Yu LIU ; Yu ZHANG ; Qianlei LANG ; Wenfan LI ; Zhenyuan XU ; Chenhao WANG ; Zhenghua XIAO ; Jia HU
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(6):366-371
Objective:To evaluate the outcomes of minimally invasive therapy for aortic arch pathology after ascending aortic replacement.Methods:A retrospective analysis was conducted at the Department of Cardiovascular Surgery, West China Hospital of Sichuan University from 2016 to 2024. After multidisciplinary discussion, these included patients were evaluated to be at high risk for traditional open surgery. Various minimally invasive repair techniques were employed, including Ⅳb hybrid technique, physician-modified endograft and novel unibody endograft. The study outcomes were technical success, in-hospital and follow-up mortality, stroke, endoleak, and the patency of the supra-aortic vessels.Results:A total of 40 patients(32 males and 8 females) with a median age of 60 years old were included in this study. The technique success rate was 100%, with no deaths or strokes reported. The patency of the supra-aortic vessels was 100%. 10 patients underwent Type Ⅳb hybrid surgery without any endoleaks occurring. Among the 22 patients who received physician-modified endograft, endoleaks were observed in 2 cases. One of these type Ⅰc endoleaks persisted and underwent reintervention. One patient underwent femoral artery replacement due to vascular injury. For the 8 patients who received novel unibody endograft, one case required reintervention due to persistent type Ⅰc endoleaks.Conclusion:With the development of different endovascular techniques and novel branched endograft, patients with aortic arch pathology who are at high risk for redo open surgery can achieve favorable outcomes with various minimal invasive techniques. However, long-term and large-sample follow-up studies are needed for further evaluation.
10.Establishment of quantitative models for effective components in Yishen Xiezhuo Mixture
Zi-fang FENG ; Min-min HU ; Xiao-wei CHEN ; Wen-ming ZHANG ; Li-hong GU ; Ping QIN ; Yi PENG ; Zhen-hua BIAN ; Qing-you YANG ; Tu-lin LU
Chinese Traditional Patent Medicine 2025;47(10):3177-3184
AIM To establish the quantitative models for gallic acid,mononucleoside,loganin,resveratrol,and rhein in Yishen Xiezhuo Mixture.METHODS HPLC was adopted in the content determination of various effective components,after which the near-infrared spectroscopy(NIRS)data were collected in 128 batches of samples and pretreatment was conducted,competitive adaptive reweighting sampling(CARS)algorithm was used for screening wavelength,partial least square method(PLS)regression analysis was performed.RESULTS There were no significant differences between the predicted values obtained by PLS models and measured values obtained by HPLC for various effective components(P>0.05).CONCLUSION The quantitative models established by NIRS combined with chemometrics display good predictive performance,which can be used for the rapid determination of effective components in Yishen Xiezhuo Mixture,and provide a reference for the rapid monitoring of other traditional Chinese medicine preparations in production processes.

Result Analysis
Print
Save
E-mail