1.Study of Reference Materials for Quantitative Analysis of Gene Copy Numbers of Lentiviral Vectors
Yin-Bo HUO ; Jia-Qi YANG ; Qing TAO ; Wen LIANG ; Li XU ; Lan-Ying LI ; Xiao-Lei ZUO ; Juan YAN ; Min DING ; Ai-Wen MA ; Gang LIU
Chinese Journal of Analytical Chemistry 2025;53(9):1555-1565
Lentiviral vectors(LVs)are key gene delivery tools for integrating target genes into the host genome,but they may also pose risks of insertional mutagenesis.The vector copy number(VCN)in cells is critical for determining the safety of gene modification.However,the reliability and accuracy of its quantification process are influenced by multiple factors.Developing cell reference materials with specific vector copy numbers represents a viable approach to enhance the reliability and consistency of measurement results,enabling quality control of the quantification process and traceability of outcomes.However,the preparation of such reference materials faces challenges in cell sample design,preparation protocols,and advanced quantification techniques.In this study,T lymphocyte cell line Jurkat-based reference materials with LV gene copy numbers of 1 and 2 copy/cell were developed.A high-precision duplex digital polymerase chain reaction(dPCR)method was established to quantify the LV gene and endogenous genes simultaneously.Additionally,the results of dPCR were cross-validated through next-generation sequencing and flow cytometric analysis.Ultimately,confocal microscopy characterization results showed that the developed cell reference materials had intact morphology.The quantification result of VCN-1 was(1.07±0.11)copy/cell,and that of VCN-2 was(2.09±0.21)copy/cell.These cell reference materials demonstrated compliance with stability and homogeneity requirements,and could be applied for quality control throughout the VCN measurement workflow and metrological traceability,improving the accuracy,comparability,and validity of copy number measurements.
2.Raman Enhancement-Nanozyme Dual Functional Nanocomposite Au@MnO2-based Surface Enhanced Raman Scattering Biosensor for Organophosphorus Pesticides
Xiao-Tong ZHANG ; Meng-Ren XUAN ; Fu-Gang XU ; Yue ZHANG
Chinese Journal of Analytical Chemistry 2025;53(10):1664-1673,中插1-中插4
Surface enhanced Raman scattering(SERS)is an important technique for detecting pesticide residues.However,many pesticides have small Raman scattering cross sections and low affinity for gold/silver enhancement substrates,resulting in low sensitivity for direct SERS detection.Indirect methods typically require complex surface modifications and have poor universality.Here,a dual functional composite Au@MnO2 combined with acetylcholinesterase(AChE)was proposed for SERS biosensing of pesticides.The Au@MnO2 with oxidase-like activity could oxidize 3,3′,5,5′-tetramethylbenzidine(TMB)into oxTMB with a large Raman scattering cross section,producing strong SERS signal using Au@MnO2 itself as enhancement substrate.In the presence of AChE,acetylthiocholine(ATCh)was catalytically hydrolyzed to produce thiocholine(TCh),and its reducibility could induce the decomposition of MnO2.Consequently,oxidase-like activity of Au@MnO2 was declined,less oxTMB was produced,and gold nanoparticles(AuNPs)detached from the MnO2 layer,resulting in a weakened SERS response.Organophosphorus pesticides(OPs),as inhibitors of AChE,prevented the production of TCh,thereby blocking the decomposition of MnO2 and leading to the recovery of Raman signals.Under optimized conditions,the Raman signal switching strategy was successfully used for detection of three OPs,i.e.,fenthion,chlorpyrifos,and methyl parathion,with detection limits of 4×10-11 mol/L,2×10-9 mol/L,and 3×10-9 mol/L,respectively.In actual spinach sample testing,the spiked recoveries of the three OPs ranged from 86.5%to 110.6%.This study provided a new strategy for detecting pesticide residues using SERS.
3.Research progress in effect of traditional Chinese medicine on aerobic glycolysis in colorectal cancer.
Xu MA ; Sheng-Long LI ; Guang-Rong ZHENG ; Da-Cheng TIAN ; Gang-Gang LU ; Jie GAO ; Yu-Qi AN ; Li-Yuan CAO ; Liang LI ; Xiao-Yong TANG
China Journal of Chinese Materia Medica 2025;50(6):1496-1506
Colorectal cancer(CRC) is a common malignant tumor worldwide. Due to the treatment intolerance and side effects, CRC rank the top among various cancers regarding the incidence and mortality rates. Therefore, exploring new therapies is of great significance for the treatment of CRC. Aerobic glycolysis(AEG) plays an important role in the microenvironment formation, proliferation, metastasis, and recurrence of CRC and other tumor cells. It has been confirmed that intervening in the AEG pathway can effectively curb CRC. The active ingredients and compound prescriptions of traditional Chinese medicine(TCM) can effectively inhibit the proliferation, metastasis, and drug resistance and regulate the apoptosis of tumor cells by modulating AEG-associated transport proteins [eg, glucose transporters(GLUT)], key enzymes [hexokinase(HK) and phosphofructokinase(PFK)], key genes [hypoxia-inducible factor 1(HIF-1) and oncogene(c-Myc)], and signaling pathways(MET/PI3K/Akt/mTOR). Accordingly, they can treat CRC, reduce the recurrence, and improve the prognosis of CRC. Although AEG plays a key role in the development and progression of CRC, the specific mechanisms are not yet fully understood. Therefore, this article delves into the intrinsic connection of the targets and mechanisms of the AEG pathway with CRC from the perspective of tumor cell glycolysis and explores how active ingredients(oxymatrine, kaempferol, and dioscin) and compound prescriptions(Quxie Capsules, Jiedu Sangen Decoction, and Xianlian Jiedu Prescription) of TCM treat CRC by intervening in the AEG pathway. Additionally, this article explores the shortcomings in the current research, aiming to provide reliable targets and a theoretical basis for treating CRC with TCM.
Humans
;
Colorectal Neoplasms/genetics*
;
Drugs, Chinese Herbal/therapeutic use*
;
Glycolysis/drug effects*
;
Animals
;
Medicine, Chinese Traditional
;
Signal Transduction/drug effects*
4.Enhancement of Ca2+ Signal Strength in Astrocytes in the Lateral Septum Improves Cognitive Disorders in Mice After Hemorrhagic Shock and Resuscitation.
Wen-Guang LI ; Lan-Xin LI ; Rong-Xin SONG ; Xu-Peng WANG ; Shi-Yan JIA ; Xiao-Yi MA ; Jing-Yu ZHANG ; Gang-Feng YIN ; Xiao-Ming LI ; Li-Min ZHANG
Neuroscience Bulletin 2025;41(8):1403-1417
Hemorrhagic shock is a common clinical emergency that can aggravate cell injury after resuscitation. Astrocytes are crucial for the survival of neurons because they regulate the surrounding ionic microenvironment of neurons. Although hemorrhagic shock and resuscitation (HSR) injury can impair cognition, it remains unclear how this insult directly affects astrocytes. In this study, we established an HSR model by bleeding and re-transfusion in mice. The social interaction test and new object recognition test were applied to evaluate post-operative cognitive changes, and the results suggest that mice experience cognitive impairment following exposure to HSR. In the HSR group, the power spectral density of β and γ oscillations decreased, and the coupling of the θ oscillation phase and γ oscillation amplitude was abnormal, which indicated abnormal neuronal oscillation and cognitive impairment after HSR exposure. In brief, cognitive impairment in mice is strongly correlated with Ca2+ signal strength in lateral septum astrocytes following HSR.
Animals
;
Astrocytes/metabolism*
;
Shock, Hemorrhagic/metabolism*
;
Resuscitation/adverse effects*
;
Male
;
Mice
;
Calcium Signaling/physiology*
;
Mice, Inbred C57BL
;
Septal Nuclei/metabolism*
;
Cognitive Dysfunction/etiology*
;
Disease Models, Animal
;
Cognition Disorders/etiology*
5.A minimally invasive, fast on/off "odorgenetic" method to manipulate physiology.
Yanqiong WU ; Xueqin XU ; Shanchun SU ; Zeyong YANG ; Xincai HAO ; Wei LU ; Jianghong HE ; Juntao HU ; Xiaohui LI ; Hong YU ; Xiuqin YU ; Yangqiao XIAO ; Shuangshuang LU ; Linhan WANG ; Wei TIAN ; Hongbing XIANG ; Gang CAO ; Wen Jun TU ; Changbin KE
Protein & Cell 2025;16(7):615-620
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail