1.Evaluation of Hemolytic Performance of Cellulose Hemostatic Products
Qing-qing HOU ; Qin-lian JIAO ; Chun-xia QIAO ; Zi-ye WANG ; Xiao-yan WANG ; Wen-qian MA ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(9):1488-1495
Objective:To compare the differences in the evaluation of hemolysis performance of cellulose hemostatic materials using different detection methods and test media,and to explore a m ore reasonable testing plan for such products.Methods:Hemolysis tests were conducted on cellulose hemostatic materials using the absorbance measurement hemolysis method and hemoglobin concentration measurement hemolysis method in accordance with YY/T 1651.1-2019 standard.We compared the changes in hemolysis rate,pH value,and osmotic pressure under different experimental media.Results:Under the same experimental method,compared to SC,the hemolysis results using PBS as the extraction medium are smaller,and the changes in pH and osmotic pressure are closer to the normal range of human body changes.Conclusions:The changes in pH and osmotic pressure may be one of the reasons for the high hemolysis rate of cellulose hemostatic materials.Choosing PBS with buffering effect as the leaching medium may be more suitable for evaluating the hemolysis performance of cellulose hemostatic materials.
2.Efficacy and long-term follow-up report of FCR regimen in the first-line treatment of chronic lymphocytic leukemia/small lymphocytic lymphoma
Xiao LU ; Yi XIA ; Yi MIAO ; Tonglu QIU ; Luomengjia DAI ; Ziyuan ZHOU ; Hui JIN ; Hairong QIU ; Chun QIAO ; Yujie WU ; Lei FAN ; Wei XU ; Jianyong LI ; Huayuan ZHU
Chinese Journal of Hematology 2025;46(11):1032-1037
Objective:To evaluate the efficacy and long-term outcomes of fludarabine, cyclophosphamide, and rituximab (FCR) in treatment-na?ve patients with chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL) .Methods:Clinical data from 68 CLL/SLL patients treated with FCR at Jiangsu Province Hospital (August 2008–May 2021) were retrospectively analyzed to assess efficacy, safety, and survival outcomes.Results:Among 68 patients [46 males, 22 females; median age 55 (47, 60) years], 13.1% (8/61) had a complex karyotype, 32.3% (20/62) had immunoglobulin heavy variable region mutated (IGHV-M) type, 6.6% (4/61) had del (17p), and 14.8% (8/54) had del (11q). Patients received a median of 6 (4, 6) FCR cycles. The overall response rate was 88.2% (60/68), including 47.0% (32/68) complete remissions. Over a median follow-up of 82 (59, 98) months, 66.2% (45/68) experienced disease progression. Median progression-free survival was 56 (21, 123) months, while median overall survival was not reached. The 5- and 10-year PFS rates were 42.6% (95% CI: 31.9–56.8% ) and 28.7% (95% CI: 19.0–43.4% ), respectively. Poor PFS was associated with del (17p) ( HR=5.04, 95% CI: 1.72–14.74, P=0.003), del (11q) ( HR=5.27, 95% CI: 2.11–13.15, P<0.001), IGHV unmutated (IGHV-UM) ( HR=4.11, 95% CI: 1.72–9.79, P=0.001), complex karyotype (CK) ( HR=3.53, 95% CI: 1.58–7.85, P=0.002), β 2-microglobulin >3.5 mg/L ( HR=2.87, 95% CI: 1.37–6.01, P=0.005). In multivariate analysis, IGHV-UM remained an independent predictor of PFS ( HR=8.63, 95% CI: 1.09–68.40, P=0.042). Sixteen patients with IGHV-M and lacking del (17p) or CK had a median PFS of 123 (58,123) months and a 5-year PFS rate of 70.7% (95% CI: 49.7–99.1% ), reaching a plateau after 5 years with no recurrences by 10 years. Common grade 3–4 adverse events included hematologic toxicity (44.1%, 30/68), infection (36.7%, 25/68), and liver dysfunction (4.4%, 3/68). Among 25 patients receiving single-agent BTK inhibitors after FCR progression, median follow-up was 45 (26, 64) months; 36% (9/25) experienced disease progression, with a median PFS time of 55 (27, 55) months. Conclusion:First-line FCR provides durable long-term benefits for patients with IGHV-M CLL without del (17p) or CK.
3.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
4.Subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets
Qiu-jin QU ; Ling-xiao SUN ; Xiao-fei WANG ; Fu-yu ZHU ; Guo-xi CHE ; Jing XU ; Xiao-yan WANG ; Nai-shui HAN ; Xiao-xia SUN ; Chun-xia QIAO
Chinese Medical Equipment Journal 2025;46(10):29-35
Objective To evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets using hydroxyethyl starch(HES)130/0.4 sodium chloride injection as an extraction medium.Methods Firstly,40 Sprague Dawley(SD)rats including 20 male and 20 female ones were seleted and randomly enrolled into a sample group and a control group by sex,with 20 ones in each group.Secondly,instead of plasma HES 130/0.4 sodium chloride injection was used to leach disposable plasma virus-inactivated blood transfusion sets to prepare the test solution by simulating clinical application such as lighting,adsorption and filtration and storage.Finally,the test solution and HES 130/0.4 sodium chloride injection were injected into the tail vein of the SD rats at a dose of 20 mL/kg for 28 d in the sample group and in the control group respectively,and the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets and the feasibility of using HES 130/0.4 sodium chloride injection as the extraction medium to assess their subchronic systemic toxicity were evaluated with clinical observation,body mass monitoring,clinical pathology examination,gross necropsy and histopathology examination.Results The sample group and control group had no significant differences in mortality rates,clinical observation results,body mass,gross necropsy results,hematological and coagulation examination results and organ weight(all P>0.05);blood biochemical examinations showed the male rats in the sample group had the cholesterol(CHO)values higher while the creatinine(CR)values lower than those in the control group,with the differences being statistically significant(both P<0.05)and the two indexes within the range of the laboratory's historical reference data,and other blood biochemical indexes were not significantly different(all P>0.05);the sample group had the spleen weight-to-body mass ratios of the female rates lower significantly than those in the control group(P<0.05),and the ratios of other organ weight to body mass had significant differences(all P>0.05);histopathology examination showed slight pathological changes in liver,spleen and kidney of female rats and in spleen and kidney of male rats in the sample group,and the female and male rats in the control group had similar pathological changes found in the sample group,which might be caused by HES metabolites.Conclusion Disposable plasma virus-inactivated blood transfusion sets prove to have no significant subchronic systemic toxicity,and its feasible to use HES 130/0.4 sodium chloride injection as the extraction medium to evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets.[Chinese Medical Equipment Journal,2025,46(10):29-35]
5.Subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets
Qiu-jin QU ; Ling-xiao SUN ; Xiao-fei WANG ; Fu-yu ZHU ; Guo-xi CHE ; Jing XU ; Xiao-yan WANG ; Nai-shui HAN ; Xiao-xia SUN ; Chun-xia QIAO
Chinese Medical Equipment Journal 2025;46(10):29-35
Objective To evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets using hydroxyethyl starch(HES)130/0.4 sodium chloride injection as an extraction medium.Methods Firstly,40 Sprague Dawley(SD)rats including 20 male and 20 female ones were seleted and randomly enrolled into a sample group and a control group by sex,with 20 ones in each group.Secondly,instead of plasma HES 130/0.4 sodium chloride injection was used to leach disposable plasma virus-inactivated blood transfusion sets to prepare the test solution by simulating clinical application such as lighting,adsorption and filtration and storage.Finally,the test solution and HES 130/0.4 sodium chloride injection were injected into the tail vein of the SD rats at a dose of 20 mL/kg for 28 d in the sample group and in the control group respectively,and the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets and the feasibility of using HES 130/0.4 sodium chloride injection as the extraction medium to assess their subchronic systemic toxicity were evaluated with clinical observation,body mass monitoring,clinical pathology examination,gross necropsy and histopathology examination.Results The sample group and control group had no significant differences in mortality rates,clinical observation results,body mass,gross necropsy results,hematological and coagulation examination results and organ weight(all P>0.05);blood biochemical examinations showed the male rats in the sample group had the cholesterol(CHO)values higher while the creatinine(CR)values lower than those in the control group,with the differences being statistically significant(both P<0.05)and the two indexes within the range of the laboratory's historical reference data,and other blood biochemical indexes were not significantly different(all P>0.05);the sample group had the spleen weight-to-body mass ratios of the female rates lower significantly than those in the control group(P<0.05),and the ratios of other organ weight to body mass had significant differences(all P>0.05);histopathology examination showed slight pathological changes in liver,spleen and kidney of female rats and in spleen and kidney of male rats in the sample group,and the female and male rats in the control group had similar pathological changes found in the sample group,which might be caused by HES metabolites.Conclusion Disposable plasma virus-inactivated blood transfusion sets prove to have no significant subchronic systemic toxicity,and its feasible to use HES 130/0.4 sodium chloride injection as the extraction medium to evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets.[Chinese Medical Equipment Journal,2025,46(10):29-35]
6.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
7.Evaluation of Hemolytic Performance of Cellulose Hemostatic Products
Qing-qing HOU ; Qin-lian JIAO ; Chun-xia QIAO ; Zi-ye WANG ; Xiao-yan WANG ; Wen-qian MA ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(9):1488-1495
Objective:To compare the differences in the evaluation of hemolysis performance of cellulose hemostatic materials using different detection methods and test media,and to explore a m ore reasonable testing plan for such products.Methods:Hemolysis tests were conducted on cellulose hemostatic materials using the absorbance measurement hemolysis method and hemoglobin concentration measurement hemolysis method in accordance with YY/T 1651.1-2019 standard.We compared the changes in hemolysis rate,pH value,and osmotic pressure under different experimental media.Results:Under the same experimental method,compared to SC,the hemolysis results using PBS as the extraction medium are smaller,and the changes in pH and osmotic pressure are closer to the normal range of human body changes.Conclusions:The changes in pH and osmotic pressure may be one of the reasons for the high hemolysis rate of cellulose hemostatic materials.Choosing PBS with buffering effect as the leaching medium may be more suitable for evaluating the hemolysis performance of cellulose hemostatic materials.
8.Efficacy and long-term follow-up report of FCR regimen in the first-line treatment of chronic lymphocytic leukemia/small lymphocytic lymphoma
Xiao LU ; Yi XIA ; Yi MIAO ; Tonglu QIU ; Luomengjia DAI ; Ziyuan ZHOU ; Hui JIN ; Hairong QIU ; Chun QIAO ; Yujie WU ; Lei FAN ; Wei XU ; Jianyong LI ; Huayuan ZHU
Chinese Journal of Hematology 2025;46(11):1032-1037
Objective:To evaluate the efficacy and long-term outcomes of fludarabine, cyclophosphamide, and rituximab (FCR) in treatment-na?ve patients with chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL) .Methods:Clinical data from 68 CLL/SLL patients treated with FCR at Jiangsu Province Hospital (August 2008–May 2021) were retrospectively analyzed to assess efficacy, safety, and survival outcomes.Results:Among 68 patients [46 males, 22 females; median age 55 (47, 60) years], 13.1% (8/61) had a complex karyotype, 32.3% (20/62) had immunoglobulin heavy variable region mutated (IGHV-M) type, 6.6% (4/61) had del (17p), and 14.8% (8/54) had del (11q). Patients received a median of 6 (4, 6) FCR cycles. The overall response rate was 88.2% (60/68), including 47.0% (32/68) complete remissions. Over a median follow-up of 82 (59, 98) months, 66.2% (45/68) experienced disease progression. Median progression-free survival was 56 (21, 123) months, while median overall survival was not reached. The 5- and 10-year PFS rates were 42.6% (95% CI: 31.9–56.8% ) and 28.7% (95% CI: 19.0–43.4% ), respectively. Poor PFS was associated with del (17p) ( HR=5.04, 95% CI: 1.72–14.74, P=0.003), del (11q) ( HR=5.27, 95% CI: 2.11–13.15, P<0.001), IGHV unmutated (IGHV-UM) ( HR=4.11, 95% CI: 1.72–9.79, P=0.001), complex karyotype (CK) ( HR=3.53, 95% CI: 1.58–7.85, P=0.002), β 2-microglobulin >3.5 mg/L ( HR=2.87, 95% CI: 1.37–6.01, P=0.005). In multivariate analysis, IGHV-UM remained an independent predictor of PFS ( HR=8.63, 95% CI: 1.09–68.40, P=0.042). Sixteen patients with IGHV-M and lacking del (17p) or CK had a median PFS of 123 (58,123) months and a 5-year PFS rate of 70.7% (95% CI: 49.7–99.1% ), reaching a plateau after 5 years with no recurrences by 10 years. Common grade 3–4 adverse events included hematologic toxicity (44.1%, 30/68), infection (36.7%, 25/68), and liver dysfunction (4.4%, 3/68). Among 25 patients receiving single-agent BTK inhibitors after FCR progression, median follow-up was 45 (26, 64) months; 36% (9/25) experienced disease progression, with a median PFS time of 55 (27, 55) months. Conclusion:First-line FCR provides durable long-term benefits for patients with IGHV-M CLL without del (17p) or CK.
9.MicroRNA-199a-5p reducing blood-brain barrier disruption following ischemic stroke in rats
Guang-Xiao NI ; Chun-Qiao DUAN ; Lu-Lu KOU ; Ran MENG ; Xiao-Qing WANG ; Pu WANG
Acta Anatomica Sinica 2024;55(4):460-467
Objective To investigate whether microRNA(miR)-199a-5p regulates blood-brain barrier(BBB)integrity through PI3K/Akt pathway after cerebral ischemia.Methods A permanent middle cerebral artery occlusion(MCAO)model was established in SPF adult male SD rats.Totally 48 rats were randomly divided into sham group(n=12),model group(n=12),MCAO+miR-199a-5p group(n=12),and MCAO+miR-199a-5p negative control group(n=12).The Ludmila Bellayev 12 point score was used to evaluate the neurobehavioral performance of rats;The integrity of the BBB after ischemia stroke was detected through Evans blue staining;Immunofluorescent staining was used to determine apoptosis after cerebral ischemia;Western blotting technology was used to detect the protein expression of claudin-5,phosphatidylinositol-3 kinase regulatory subunit 2(PIK3R2),p-Akt,Akt,and vascular endothelial growth factor(VEGF)-A;Real-time PCR was used to investigate the expression levels of miR-199a-5p,claudin-5,and VEGF-A in the ischemic penumbra and infarcted area of the brain.Results The result showed that miR-199a-5p mimic intervention improved proprioception and motor ability in MCAO rats.MiR-199a-5p mimic reduced the expression of PIK3R2 following ischemia stroke,activated the Akt signaling pathway,and increased the expression of claudin-5 and VEGF-A in the ischemic penumbra.In addition,miR-199a-5p alleviated inflammation after cerebral ischemia.MiR-199a-5p mimic reduced BBB permeability and reduced neuronal apoptosis after cerebral ischemia.Conclusion MiR-199a-5p can reduce the expression of PIK3R2 following ischemic stroke,activate the Akt signaling pathway,reduce the expression of inflammatory cytokines,and alleviate the damage to the blood-brain barrier.
10.Design, synthesis, and antifungal mechanism of carbaline fluorescent probes
Xiao-qing WANG ; Ji YANG ; Qiao SHI ; Dong-jian XU ; Na LIU ; Chun-quan SHENG
Acta Pharmaceutica Sinica 2024;59(3):643-650
Three carboline fluorescent probes F1-F3 were designed and synthesized, based on lead compound JYJ-19, an antifungal compound discovered previously by our group. The antifungal activity

Result Analysis
Print
Save
E-mail