1.Spatiotemporal Electrical Impedance Tomography for Speech Respiratory Assessment in Cleft Palate: an Interpretable Machine Learning Study
Yang WU ; Xiao-Jing ZHANG ; Hao YU ; Cheng-Hui JIANG ; Bo SUN ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2026;53(2):485-500
ObjectiveCleft palate (CP) is a common congenital deformity often associated with velopharyngeal insufficiency (VPI), which disrupts the physiological coupling between respiration and speech. Conventional clinical assessments, such as nasometry and spirometry, provide limited static data and fail to visualize the dynamic spatiotemporal distribution of lung ventilation during phonation. This study introduces spatiotemporal electrical impedance tomography (ST-EIT) to evaluate speech-respiratory functional features in CP patients compared to normal controls (NC). The aim is to characterize multi-domain respiratory patterns and to validate an interpretable machine learning framework for providing objective, quantitative evidence for clinical assessment. MethodsSeventy-five participants were enrolled in this study, comprising 37 patients with surgically repaired CP and 38 healthy volunteers matched for age, gender, and body mass index (BMI). All subjects performed standardized sustained phonation tasks while undergoing synchronous monitoring with a 16-electrode EIT system and a pneumotachograph. A comprehensive feature engineering pipeline was developed to extract physiological parameters across 3 complementary domains. (1) Temporal domain: including inspiratory/expiratory phase duration (tPhase), time constants (Tau), and inspiratory-to-expiratory time ratios (TI/TE); (2) airflow domain: comprising mean flow, peak flow, and instantaneous flow at 25%, 50%, and 75% of tidal volume; and (3) spatial domain: quantifying global and regional tidal impedance variation (TIV), global inhomogeneity (GI), and center of ventilation (CoV). Extreme Gradient Boosting (XGBoost) classifiers were trained using 5 distinct data sources (Spirometry, Nasometry, Inspiratory-EIT, Expiratory-EIT, and fused ST-EIT). Model performance was rigorously evaluated via stratified 5-fold cross-validation, and Shapley additive explanations (SHAP) were employed to quantify global and local feature contributions. ResultsThe CP group exhibited a distinct respiratory phenotype compared to controls. In the temporal domain, CP patients showed significantly shorter inspiratory (1.60 s vs.1.85 s, P<0.001) and expiratory phase durations (2.45 s vs. 3.95 s, P<0.001), indicating a rapid, shallow breathing rhythm. In the airflow domain, while inspiratory flows were comparable, the CP group demonstrated significantly elevated mean and peak flows during the expiratory phase (P<0.001), reflecting compensatory respiratory effort. Spatially, CP patients presented significant ventilation redistribution, characterized by higher regional TIV in the right-anterior (ROI1) and left-posterior (ROI4) quadrants, but lower TIV in the left-anterior (ROI2) quadrant. In terms of diagnostic accuracy, the multi-modal ST-EIT model achieved the highest performance (AUC: 0.915±0.012, Accuracy: 0.843±0.019, F1-score: 0.872±0.017), substantially outperforming models based on spirometry (AUC: 0.721) or nasometry (AUC: 0.625) alone. Interpretability analysis revealed that spatial domain features were the most critical, contributing 53.4% to the model’s decision-making, followed by temporal (25.0%) and airflow (21.6%) features. ConclusionST-EIT successfully captures the temporal, airflow, and spatial deviations in CP speech respiration that are undetectable by conventional methods—specifically, rapid phase transitions, hyperdynamic expiratory airflow, and regional ventilation heterogeneity. This study validates ST-EIT as a robust, non-invasive, and radiation-free tool for characterizing speech-respiratory dysfunction, offering high clinical value for bedside screening, rehabilitation planning, and longitudinal monitoring of patients with cleft palate.
2.Spatiotemporal Electrical Impedance Tomography for Speech Respiratory Assessment in Cleft Palate: an Interpretable Machine Learning Study
Yang WU ; Xiao-Jing ZHANG ; Hao YU ; Cheng-Hui JIANG ; Bo SUN ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2026;53(2):485-500
ObjectiveCleft palate (CP) is a common congenital deformity often associated with velopharyngeal insufficiency (VPI), which disrupts the physiological coupling between respiration and speech. Conventional clinical assessments, such as nasometry and spirometry, provide limited static data and fail to visualize the dynamic spatiotemporal distribution of lung ventilation during phonation. This study introduces spatiotemporal electrical impedance tomography (ST-EIT) to evaluate speech-respiratory functional features in CP patients compared to normal controls (NC). The aim is to characterize multi-domain respiratory patterns and to validate an interpretable machine learning framework for providing objective, quantitative evidence for clinical assessment. MethodsSeventy-five participants were enrolled in this study, comprising 37 patients with surgically repaired CP and 38 healthy volunteers matched for age, gender, and body mass index (BMI). All subjects performed standardized sustained phonation tasks while undergoing synchronous monitoring with a 16-electrode EIT system and a pneumotachograph. A comprehensive feature engineering pipeline was developed to extract physiological parameters across 3 complementary domains. (1) Temporal domain: including inspiratory/expiratory phase duration (tPhase), time constants (Tau), and inspiratory-to-expiratory time ratios (TI/TE); (2) airflow domain: comprising mean flow, peak flow, and instantaneous flow at 25%, 50%, and 75% of tidal volume; and (3) spatial domain: quantifying global and regional tidal impedance variation (TIV), global inhomogeneity (GI), and center of ventilation (CoV). Extreme Gradient Boosting (XGBoost) classifiers were trained using 5 distinct data sources (Spirometry, Nasometry, Inspiratory-EIT, Expiratory-EIT, and fused ST-EIT). Model performance was rigorously evaluated via stratified 5-fold cross-validation, and Shapley additive explanations (SHAP) were employed to quantify global and local feature contributions. ResultsThe CP group exhibited a distinct respiratory phenotype compared to controls. In the temporal domain, CP patients showed significantly shorter inspiratory (1.60 s vs.1.85 s, P<0.001) and expiratory phase durations (2.45 s vs. 3.95 s, P<0.001), indicating a rapid, shallow breathing rhythm. In the airflow domain, while inspiratory flows were comparable, the CP group demonstrated significantly elevated mean and peak flows during the expiratory phase (P<0.001), reflecting compensatory respiratory effort. Spatially, CP patients presented significant ventilation redistribution, characterized by higher regional TIV in the right-anterior (ROI1) and left-posterior (ROI4) quadrants, but lower TIV in the left-anterior (ROI2) quadrant. In terms of diagnostic accuracy, the multi-modal ST-EIT model achieved the highest performance (AUC: 0.915±0.012, Accuracy: 0.843±0.019, F1-score: 0.872±0.017), substantially outperforming models based on spirometry (AUC: 0.721) or nasometry (AUC: 0.625) alone. Interpretability analysis revealed that spatial domain features were the most critical, contributing 53.4% to the model’s decision-making, followed by temporal (25.0%) and airflow (21.6%) features. ConclusionST-EIT successfully captures the temporal, airflow, and spatial deviations in CP speech respiration that are undetectable by conventional methods—specifically, rapid phase transitions, hyperdynamic expiratory airflow, and regional ventilation heterogeneity. This study validates ST-EIT as a robust, non-invasive, and radiation-free tool for characterizing speech-respiratory dysfunction, offering high clinical value for bedside screening, rehabilitation planning, and longitudinal monitoring of patients with cleft palate.
3.Investigation of natural radionuclide activity in drinking water in Hohhot, China
Bo JU ; Yulong BAO ; Shuai ZHANG ; Xiang LIU ; Xiao XU ; Zhichao SUN ; Xiaojuan YANG
Chinese Journal of Radiological Health 2026;35(2):159-164
Objective To investigate the activity concentrations of natural radionuclides in drinking water (tap water and well water) in urban and rural areas of Hohhot, assess the safety of drinking water, and to provide data support for local drinking water radioactivity monitoring and management. Methods Representative samples of well water and tap water were collected from nine banners/counties/districts in Hohhot. Activity concentrations were measured using a low-background gross α/β counter, an α spectrometer, inductively coupled plasma mass spectrometry, and a radium/radon analyzer. Results A total of nine tap water samples and nine well water samples were analyzed. For the tap water samples, gross α activity concentrations ranged from 0.093 to 0.193 Bq/L, gross β from 0.091 to 0.225 Bq/L, uranium mass concentrations from 2.32 to 10.36 μg/L, thorium mass concentrations from 0.09 to 0.20 μg/L,210Po activity concentrations from below the minimum detectable limit to 0.41 mBq/L, and 226Ra activity concentrations from 8.70 to 13.35 mBq/L. For the well water samples, gross α activity concentrations ranged from 0.111 to 0.203 Bq/L, gross β from 0.111 to 0.270 Bq/L, uranium mass concentrations from 2.31 to 13.28 μg/L, thorium mass concentrations from 0.17 to 0.26 μg/L,210Po activity concentrations from 1.03 to 2.12 mBq/L, and 226Ra activity concentrations from 15.38 to 23.63 mBq/L. Conclusion The activity concentrations of natural radionuclides in both well water and tap water in the Hohhot region were at environmental background levels and met national drinking water hygiene standards.
4.MTAP Orchestrates Stemenss and 5-Fluorouracil Resistance in Liver Cancer via PRMT5/SOX2 Signaling
Yu-Bo ZHANG ; Zhao-Xiong FANG ; Yun LI ; Jie DONG ; Xiao-Peng HONG ; Hui LUO
Progress in Biochemistry and Biophysics 2026;53(10):2797-2807
ObjectiveMethylthioadenosine phosphorylase (MTAP) is found to be frequently deleted in malignant cancers, but the role of MTAP underlying metastasis and stemness of liver cancer remains far from clear. 5-fluorouracil (5-Fu) is clinically used in treating advanced liver cancer, however, chemoresistance is one of the major barriers impeding its efficacy. Liver cancer stem cells are considered to be the reservoir for tumor progression and chemoresistance. This study aims to explore the role of MTAP in regulating stemness and chemoresistance of 5-Fu in liver cancer. It is designed to elucidate the molecular mechanisms underlying MTAP-manipulated stemness. How MTAP influences metastasis and chemoresistance against 5-Fu in liver cancer is also elaborated. MethodsThe correlation of MTAP expression with stemness marker CD133 was evaluated by flow cytometry. Colony formation assays were conducted to analyze the tumorigenic ability. Western blot assays were applied to delineate the molecular mechanisms underlying MTAP-regulated stemness. Trans-well assays were conducted to analyze the metastatic potential of liver cancer cells.In vivo experiments were performed using subcutaneous xenograft and lung metastasis model on nude mice. Tumor size and weight were analyzed upon 5-Fu treatment. Metastatic nodules on lungs were evaluated. Immunohistochemical and TUNNEL assays were performed on slides obtained from tumor tissues. ResultsMTAP overexpression inhibited expression of CD133 and colony formation, which is further ablated by MTAP inhibitor. MTAP deprivation augmented stemness and colony formation, which is reversed by protein arginine methyltransferase 5 (PRMT5) overexpression but not its catalytically inactive counterparts. Critically, SRY-box transcription factor 2 (SOX2) was found to be a downstream regulator of MTAP/PRMT5, leading to stemness of liver cancer cells. MTAP overexpression suppressed SOX2 expression, while MTAP inhibition augmented expression of SOX2. Critically, MTAP overexpression inhibited migration and invasion of liver cancer cells. In vivo experiments in animal model found that MTAP deprivation promotes tumor growth and metastatic nodules of liver cancer. Additionally, MTAP overexpression inhibits tumor growth. Moreover, MTAP deprivation contributes to chemoresistance shown by increased tumor size and weight treated by 5-Fu. In contrast, MTAP overexpression led to further decline in tumor size and weight elicited by 5-Fu treatment. Accordingly, SOX2 was inhibited in tumor tissues after MTAP overexpression. Marker of proliferation Ki67 (Ki67) expression was dampened while apoptosis was found in MTAP-overexpressed tumor tissues. ConclusionIn this study, plethora of experimental studies collectively demonstrated that MTAP deprivation enhances stemness of liver cancer by regulating SOX2, exerting anti-cancer and chemoresistant role against 5-Fu in liver cancer. It is also worth noting that MTAP inhibition promoted metastasis of liver cancer. MTAP overexpression augmented tumor shrinking elicited by 5-Fu and SOX2 was involved in this process. These results concluded that MTAP/PRMT5/SOX2 signaling axis was involved in regulating stemness and chemoresistance of liver cancer. These findings help to exploit novel therapies by targeting stemness in MTAP-depleted liver cancer. It shed novel light on unveiling MTAP-regulated stemness in antagonizing 5-Fu treatment in liver cancer. It also adds mounting evidence to the theoretical basis for accomplishing personalized chemotherapy of liver cancer patients by targeting MTAP or its downstream PRMT5/SOX2.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Study on The Detection Method of Fat Infiltration in Muscle Tissue Based on Phase Angle Electrical Impedance Tomography
Wu-Guang XIAO ; Xiao-Peng ZHU ; Hui FENG ; Bo SUN ; Tong ZHAO ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2025;52(10):2663-2676
ObjectiveFat infiltration has been shown to be closely related to muscle mass loss and a variety of muscle diseases. This study proposes a method based on phase-angle electrical impedance tomography (ΦEIT) to visualize the electrical characteristic response caused by muscle fat infiltration, aiming to provide a new technical means for early non-invasive detection of muscle mass deterioration. MethodsThis study was divided into two parts. First, a laboratory pork model was constructed to simulate different degrees of fat infiltration by injecting1 ml or 2 ml of emulsified fat solution into different muscle compartments, and the phase angle images were reconstructed using ΦEIT. Second, a human experiment was conducted to recruit healthy subjects (n=8) from two age groups (20-25 years old and 26-30 years old). The fat content percentage ηfat of the left and right legs was measured by bioelectrical impedance analysis (BIA), and the phase angle images of the left and right calves were reconstructed using ΦEIT. The relationship between the global average phase angle ΦM and the spatial average phase angle ΦMi of each muscle compartment and fat infiltration was further analyzed. ResultsIn the laboratory pork model, the grayscale value of the image increased with the increase of ηfat and ΦM showed a downward trend. The results of human experiments showed that at the same fat content percentage, the ΦM of the 26-30-year-old group was about 20%-35% lower than that of the 20-25-year-old group. The fat content percentage was significantly negatively correlated with ΦM. In addition, the M2 (soleus) compartment was most sensitive to fat infiltration, and the spatial average phase angles of the M2 (soleus), M3 (tibialis posterior and flexor digitorum longus), and M4 (tibialis anterior, extensor digitorum longus, and peroneus longus) compartments all showed significant inter-group differences. ConclusionΦEIT imaging can effectively distinguish different degrees of fat infiltration, especially in deep, small or specially located muscles, showing high sensitivity, demonstrating the potential application of this method in local muscle mass monitoring and early non-invasive diagnosis.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.