1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Veronica anagallis-aquatica L. iridoid glycosides alleviate heart failure via metabolites homoveratrumic acid and 2-hydroxy-3,4-dimethoxybenzoic acid mediated by the gut microbiota.
Manjiong WANG ; Xiaobo GUO ; Hanfang LIU ; Xiao LI ; Yue YAO ; Qing FU ; Yu JIN ; Shuaishuai NI ; Xiaokang LI ; Chaojiang XIAO ; Bei JIANG ; Conglong XIA ; Jian LI ; Yixiang XU
Acta Pharmaceutica Sinica B 2025;15(6):3338-3342
The iridoid glycosides from Veronica anagallis-aquatica L. alleviate heart failure by modulating the gut microbiota and influencing the production of two metabolites with potential antihypertrophic effects, HVA and 2OH-VA.Image 1.
7.Histaminergic Innervation of the Ventral Anterior Thalamic Nucleus Alleviates Motor Deficits in a 6-OHDA-Induced Rat Model of Parkinson's Disease.
Han-Ting XU ; Xiao-Ya XI ; Shuang ZHOU ; Yun-Yong XIE ; Zhi-San CUI ; Bei-Bei ZHANG ; Shu-Tao XIE ; Hong-Zhao LI ; Qi-Peng ZHANG ; Yang PAN ; Xiao-Yang ZHANG ; Jing-Ning ZHU
Neuroscience Bulletin 2025;41(4):551-568
The ventral anterior (VA) nucleus of the thalamus is a major target of the basal ganglia and is closely associated with the pathogenesis of Parkinson's disease (PD). Notably, the VA receives direct innervation from the hypothalamic histaminergic system. However, its role in PD remains unknown. Here, we assessed the contribution of histamine to VA neuronal activity and PD motor deficits. Functional magnetic resonance imaging showed reduced VA activity in PD patients. Optogenetic activation of VA neurons or histaminergic afferents significantly alleviated motor deficits in 6-OHDA-induced PD rats. Furthermore, histamine excited VA neurons via H1 and H2 receptors and their coupled hyperpolarization-activated cyclic nucleotide-gated channels, inward-rectifier K+ channels, or Ca2+-activated K+ channels. These results demonstrate that histaminergic afferents actively compensate for Parkinsonian motor deficits by biasing VA activity. These findings suggest that targeting VA histamine receptors and downstream ion channels may be a potential therapeutic strategy for PD motor dysfunction.
Animals
;
Histamine/metabolism*
;
Male
;
Oxidopamine/toxicity*
;
Rats
;
Ventral Thalamic Nuclei/physiopathology*
;
Rats, Sprague-Dawley
;
Disease Models, Animal
;
Parkinson Disease/metabolism*
;
Neurons/physiology*
;
Humans
;
Optogenetics
8.The Dance Between Schwann Cells and Macrophages During the Repair of Peripheral Nerve Injury.
Wei LI ; Guixian LIU ; Jie LIANG ; Xiao WANG ; Meiying SONG ; Xiaoli LIU ; Luoyang WANG ; Zijie YANG ; Bei ZHANG
Neuroscience Bulletin 2025;41(8):1448-1462
Schwann cells and macrophages are the main immune cells involved in peripheral nerve injury. After injury, Schwann cells produce an inflammatory response and secrete various chemokines, inflammatory factors, and some other cytokines to promote the recruitment and M2 polarization of blood-derived macrophages, enhancing their phagocytotic ability, and thus play an important role in promoting nerve regeneration. Macrophages have also been found to promote vascular regeneration after injury, promote the migration and proliferation of Schwann cells along blood vessels, and facilitate myelination and axon regeneration. Therefore, there is a close interaction between Schwann cells and macrophages during peripheral nerve regeneration, but this has not been systematically summarized. In this review, the mechanisms of action of Schwann cells and macrophages in each other's migration and phenotypic transformation are reviewed from the perspective of each other, to provide directions for research on accelerating nerve injury repair.
Schwann Cells/metabolism*
;
Peripheral Nerve Injuries/physiopathology*
;
Animals
;
Macrophages/immunology*
;
Nerve Regeneration/physiology*
;
Humans
;
Cell Movement/physiology*
9.Anatomical structures of the matrix channel network for interstitial fluid flow in the human hand
Tian-Tian LI ; Jian-Ping ZHAO ; Chao-Zhi YANG ; Zhen CHEN ; Nai-Li WANG ; Bei LI ; Jin CAI ; Xiao-Yu WANG ; Hong-Yi LI
Acta Anatomica Sinica 2025;56(3):307-314
Objective To investigate the anatomical and microscopic structures of interstitial fluid flow channels in the skin tissue of hand dorsum in human cadavers.Methods Totally 7 fresh cadavers within 12 hours post-mortem were included.MRI was used to observe the distribution of interstitial fluid flow from the first phalanx of the fingers to the wrist,precisely locating the flow channels.Based on imaging results,histological analyses were conducted to determine the histological characteristics of the flow channels.Furthermore,multi-immunofluorescence and microcomputed tomography(Micro-CT)techniques were employed to analyze the channels,and image post-processing was used to elucidate their anatomical structures at the microscopic level.Results After injecting a contrast agent into the first phalanx of ten finger specimens and applying repeated pressure,MRI image revealed centripetal long-range interstitial fluid flow along channels distinct from blood vessels and lymphatic vessels.Histological analysis and Micro-CT further confirmed that the flow primarily occurred within the fibrous connective tissue and adventitia of the skin.Conclusion The orderly fibrous connective tissue and adventitia in the skin form the interstitial fluid flow channels in the human hand dorsum skin,named as"stromal membrane channels"in the skin.
10.Antimicrobial susceptibility and molecular characterization of Streptococcus agalactiae in pregnant women with advanced maternal age in Tangshan City
Ze-Liang LIU ; Xin-Yi GONG ; Xiao HAN ; Xue-Qi JIANG ; Bei-Bei MIAO ; Shuang MENG ; Ai-Ying DONG ; Juan LI
Chinese Journal of Infection Control 2024;23(10):1199-1205
Objective To analyze the antimicrobial susceptibility,molecular types,serotypes,virulence factors and resistance mechanisms of Streptococcus agalactiae(S.agalactiae)isolated from pregnant women with ad-vanced maternal age in Tangshan City,and provide basic data for the treatment,prevention and control of S.aga-lactiae infection.Methods 42 strains of S.agalactiae isolated from pregnant women with advanced maternal age in North China University of Science and Technology Affiliated Hospital as well as Tangshan Maternal and Child Health Hospital were collected.Detection of antimicrobial susceptibility and whole genome sequencing of 13 antimi-crobial agents were performed.Results The percentage of tetracycline,erythromycin,levofloxacin,and chloram-phenicol concurrently resistant strains was 7.1%,35.7%of the strains presented multidrug resistance to erythro-mycin,clindamycin,and levofloxacin.The carriage rates of resistance genes ermB and tetM were 66.7%and 47.6%,respectively.29 strains(69.0%)exhibited mutations in both gyrA and parC fluoroquinolone resistance determi-nants.42 strains of S.agalactiae belonged to 4 serotypes,namely ⅠB(35.7%),Ⅲ(33.3%),Ⅴ(26.2%),andⅠA(4.8%);and 11 sequence types(STs),with the highest proportion being ST10(35.7%)and ST19(31.0%);as well as 6 clonal complexes(CCs),among which CC19(42.9%)and CC12(35.7%)had the highest proportion.All S.agalactiae carried virulence factor-encoding genes of cfb,cylE,and pavA.Conclusion The molecular types and serotypes of S.agalactiae carried by pregnant women with advanced maternal age in Tangshan City pre-sent polymorphism,with obvious multidrug resistance,and carry multiple types of drug resistance genes and viru-lence genes.

Result Analysis
Print
Save
E-mail