1.SIRT5 Potentiates Hepatocarcinogenesis by Modulating Protein Acylation in Mice
Yu ZHANG ; Feng-Rui REN ; Jia-Yun LI ; Xiang-Yu CHEN ; Zi-Yi WANG ; Qi SUN ; Jun-Cheng ZHAO ; Ye ZHANG ; Zhen HUANG ; Hao HU ; Tao-Tao WEI ; Min XIAO
Progress in Biochemistry and Biophysics 2026;53(6):1712-1722
ObjectiveHepatocellular carcinoma (HCC) represents 90% of all primary liver cancers. The main risk factors associated with HCC include viral hepatitis (B and/or C), alcohol abuse, and metabolic dysfunction-associated steatotic liver disease (MASLD), which progressively advance to liver fibrosis, cirrhosis, and ultimately evolve into HCC. Surgical resection represents the most effective treatment for HCC, while recent advances in immunotherapy, including immune checkpoint inhibitors and adoptive cell therapies, have provided improved treatment prospects for patients with unresectable HCC. However, the complex metabolic heterogeneity of HCC limits the therapeutic efficacy. Metabolic intermediates acyl-CoA not only provide energy and substrates for numerous biochemical reactions but also serve as donors for protein lysine acylation, a major class of post-translational modification (PTM). Therefore, a deeper understanding of the molecular mechanisms underlying protein lysine acylation and hepatocarcinogenesis is urgently needed. MethodsThe levels of protein lysine acylation and silence information regulator 5 (SIRT5) expression levels in clinical HCC samples were analyzed by Western blot. Quantitative malonylome and succinylome of HCC samples were analyzed by antibody-based affinity enrichment coupled with tandem mass spectrometry. The proliferation of HCC cells was analyzed with Cell Counting Kit-8 (CCK-8) assays, the apoptosis was quantified by Annexin V-FITC/propidium iodide (PI) staining coupled with flow cytometry, and the ability of cells to migrate was assayed by Transwell assays. The enzymatic activity of glutathione S-transferase Mu 1 (GSTM1) was quantified. Transgenic mice with hepatic overexpression of SIRT5 were constructed using CRISPR-Cas9, and primary hepatocarcinogenesis was induced by administration of diethylnitrosamine. ResultsWestern blot analysis indicated that the expression level of SIRT5 was elevated in clinical samples from HCC patients, and the levels of lysine malonylation, glutarylation, and succinylation were significantly reduced in HCC tissues. Knockout of SIRT5 in MHCC-97H and MHCC-97L hepatoma cells suppressed cell proliferation, and increased the percentage of apoptotic cells significantly. Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analyses of the differentially malonylome and succinylome of HCC samples revealed significant enrichment in two major classes of biological processes: core energy metabolism (e.g., glycolysis/gluconeogenesis, tricarboxylic acid metabolic process, fatty acid beta oxidation) and detoxification and oxidative stress response (e.g., response to toxic substance, chemical carcinogenesis, reactive oxygen species (ROS)). SIRT5 removes malonylation from lysine residues in GSTM1 and restores its detoxification activity, which is crucial for the survival of hepatocytes under stressed conditions. More importantly, in vivo experiment indicated that hepatic-specific overexpression of SIRT5 in mice accelerated diethylnitrosamine-induced liver fibrosis and hepatocarcinogenesis, indicating the critical role of SIRT5 in HCC progression. ConclusionThis study highlights the previously unrecognized SIRT5-GSTM1 axis as a key regulator in hepatocarcinogenesis, and suggests a potential target for the treatment of patients with HCC.
2.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
3.Impact factors and reference range upper limit of thyroid volume in children aged 8-10 years old in Huangpu District, Shanghai
Weihua CHEN ; Chengdi SHAN ; Lili SONG ; Lifang MA ; Yun CAO ; Youshun QIAN ; Aina HE ; Jun XIAO
Journal of Environmental and Occupational Medicine 2025;42(2):205-210
Background As one of the key populations in the prevention and treatment of iodine deficiency disorders, it is important to continuously monitor the iodine nutritional level of school-age children. The current reference interval for thyroid volume in China is based on age only, without taking into account differences in individual developmental levels, and the distribution of thyroid volume may vary regionally due to economic, demographic, and environmental factors. The current reference cut-off points for thyroid volume proposed by the World Health Organization are not based on the Chinese population. Objective To understand the iodine nutritional status and distribution of thyroid volume (Tvol) among children aged 8-10 years in Huangpu District, Shanghai, China, to identify impact factors of Tvol, and to propose a reference range upper limit for local thyroid health surveillance, so as to provide a basis for goiter control and prevention. Methods Six hundred children aged 8-10 years in Huangpu District were recruited in 2017, 2020, and 2023, and body height, weight, thyroid volume, urinary iodine, and iodine content of household edible salt were determined. A multilevel model was constructed using population density and area as regional variables, and age, body surface area (BSA), and body mass index (BMI) as potential impact factors for at the individual level, to assess their effects on thyroid volume. Quantile regression of thyroid volume was performed, and the 98th percentile (P98) of thyroid volume was predicted based on age and BSA. Results The iodized salt coverage in the households of surveyed children in 2017, 2020, and 2023 was 72.0%, 57.0%, and 48.0%, respectively, and the iodized salt coverage decreased by year (χ2=24.31, P<0.001). The urinary iodine level of children in 2017 was higher than that in 2020 and 2023 (χ2=18.77, P<0.001). The Tvol medians of children in 2017, 2020, and 2023 were 2.29, 2.49, and 2.97 mL, respectively, and the Tvol increased by year (χ2=60.04, P<0.001). The proportion of goiter was higher in children in 2023 than in 2017 and 2020 (χ2=6.57, P<0.05). Sex differences were not statistically significant for urinary iodine levels, thyroid volume, and goiter. The median Tvol was 2.26, 2.58, and 2.76 mL in children of 8, 9, and 10 years old respectively, and the Tvol increased with age (χ2=49.02, P <0.001). Tvol was positively correlated with age, BSA, and BMI with correlation coefficients of
4.A Sensitive Ion Chromatography-Inductively Coupled Plasma Mass Spectrometry Method for Analysis of Iodine Speciation in Environmental Water Samples
Huan JIANG ; Ning CHEN ; Yan-Yun WANG ; Yu-Kun FAN ; Meng-Ting ZHANG ; Lu-Yuan ZHANG ; Xiao-Lin HOU
Chinese Journal of Analytical Chemistry 2025;53(2):278-288
Iodine speciations in aquatic environments are affected by dissolved oxygen,redox potential,microbial activity,organic matter decomposition,light reaction,etc.Accurate quantification of iodine speciation can not only help to understand the geochemical cycle of iodine,but also help to trace and study environmental processes.Based on the combination of ion chromatography(IC)and inductively coupled plasma mass spectrometry(ICP-MS),a rapid and sensitive method was established for determining the speciations of iodine in environmental water samples including seawater,river water,lake water,rainwater,groundwater,etc.The results presented here showed that IO3?and I?in seawater were quickly separated and measured within 120 s when using guard column AG22 and 8 mmol/L(NH4)2CO3 as the mobile phase.While for lake water,river water and precipitation samples with high soluble organically bond iodine(SOI),an AS22 separation column(250 mm×4 mm)connected with a guard column and using 50 mmol/L(NH4)2CO3 as mobile phase could effectively separate unknown SOI from IO3? to achieve accurate quantification of IO3?.For accurate correction of iodine measurement signal fluctuations,133Cs was directly added to the(NH4)2CO3 mobile phase as an internal standard.The SOI content was calculated by the total iodine concentrations minus the sum of IO3?and I?.The precision of the established iodine speciation analytical method was better than 3.5%,and the standard addition experiment showed that the analytical method was accurate.When the injection volume was 25 μL,the detection limits were 0.011?0.025 μg/L for IO3? and 0.023?0.031 μg/L for I?,respectively.The method was successfully used to analyze IO3?,SOI and I? in environmental water samples,such as seawater,river water,rainwater and groundwater.
5.Highly Sensitive Mass Spectrometric Analysis of Trace Iodine in Environmental Samples
Huan JIANG ; Yan-Yun WANG ; Yu-Kun FAN ; Ning CHEN ; Xiao-Lin HOU
Chinese Journal of Analytical Chemistry 2025;53(9):1536-1545
The cycling of iodine in the atmosphere and ocean plays a critical role in climate and environmental change.Ice cores and tree rings,as ideal climate archives,can provide essential data for paleoclimate reconstruction through accurate iodine analysis.However,iodine concentrations in ice core samples are as low as 0.01 μg/L,and as low as 0.01 μg/g in tree rings.Most currently reported analytical methods face challenges in accurately quantifying such low levels.In this study,a highly sensitive analytical method for trace iodine in environmental samples was developed based on inductively coupled plasma mass spectrometry(ICP-MS),incorporating a collision/reaction cell under the optimized collision/reaction gas conditions.Collision/reaction cell mode was employed to evaluate potential interferences in determination of trace iodine by ICP-MS.The results indicated that peak tailing from adjacent mass-to-charge ratios and polyatomic ion interferences could be considered negligible.However,residual iodine in ultrapure water constituted the major source of background,highlighting the need for strict control of sample pretreatment and procedural blanks in trace-level iodine analysis.By utilizing collision focusing effect of helium,the measurement sensitivity of iodine was enhanced to 3.5×105 cps(counts per second)/(μg/L),and the detection limit was reduced to 0.002 μg/L.The developed method exhibited a deviation of less than 2.3%in measurement of low-concentration standard solutions,indicating good accuracy.For actual samples and blanks,the precision of repeated measurements within 2 h was better than 1.6%,demonstrating excellent repeatability.No significant memory effect was observed during the measurements.The established method was successfully applied to determination of trace iodine in ice cores,tree rings,and other environmental samples,providing a robust technical foundation for investigating the role of iodine in climate and environmental change.
6.Comparison of Three Drowning-related Plankton Testing Methods in Drowning Diagnosis
Xiao-Feng ZHANG ; Qin SU ; Xiao-Hui CHEN ; Wei-Bin WU ; Dong-Yun ZHENG ; Jian ZHAO ; Ling CHEN ; Qu-Yi XU ; Chao LIU
Journal of Forensic Medicine 2025;41(3):244-251
Objective To compare the application effects of plankton multiplex polymerase chain reac-tion-capillary electrophoresis(PCR-CE),SYBR Green Ⅰ real-time quantitative PCR(qPCR)and microwave digestion-vacuum filtration-automated scanning electron microscopy(MD-VF-Auto SEM)in the diagnosis of drowning.Methods Lung,liver and kidney tissues from 212 drowned corpses and 30 non-drowned corpses were examined respectively by the three drowning-related plankton testing methods,and the detection rates of plankton in each tissue by three methods were compared.Results In drowned corpses,the total detection rates of PCR-CE,qPCR,and MD-VF-Auto SEM were 93.9%,96.2%,and 95.3%,respectively,with no statistically significant difference(P>0.05).The detection rate of lung tissue by MD-VF-Auto SEM(100%)was higher than those of PCR-CE and qPCR(P<0.05),and there was no significant difference in the detection rates of the three methods in liver or kidney tissues(P>0.05).In non-drowning corpses,a small number of diatoms(less than 10 cells/10 g)were detected by MD-VF-Auto SEM method,only in liver and kidney tissues,while the other two methods yielded negative results for all tissues.Conclusion All three methods have good efficacy in the examination of drowned corpses.The MD-VF-Auto SEM method directly observes diatom morpho-logical characteristics through scanning electron microscopy,and the qualitative and quantitative analy-ses are intuitive and accurate.It has great advantages in the examination of difficult degradation samples.The PCR-CE method and qPCR method have a low sample demand(0.5 g),are easy to operate and have short detection time(4-7 h).They are easy to be applied in the grassroots depart-ments and are suitable for the rapid determination of drowned corpses in routin cases.The combina-tion of the two DNA methods with the MD-VF-Auto SEM method can increase the detection rate of plankton,ensuring the reliability of examination results.This combined use is of significant importance in the application of drowning diagnosis.
7.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
8.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
9.Genetic and clinical characteristics of children with RAS-mutated juvenile myelomonocytic leukemia.
Yun-Long CHEN ; Xing-Chen WANG ; Chen-Meng LIU ; Tian-Yuan HU ; Jing-Liao ZHANG ; Fang LIU ; Li ZHANG ; Xiao-Juan CHEN ; Ye GUO ; Yao ZOU ; Yu-Mei CHEN ; Ying-Chi ZHANG ; Xiao-Fan ZHU ; Wen-Yu YANG
Chinese Journal of Contemporary Pediatrics 2025;27(5):548-554
OBJECTIVES:
To investigate the genomic characteristics and prognostic factors of juvenile myelomonocytic leukemia (JMML) with RAS mutations.
METHODS:
A retrospective analysis was conducted on the clinical data of JMML children with RAS mutations treated at the Hematology Hospital of Chinese Academy of Medical Sciences, from January 2008 to November 2022.
RESULTS:
A total of 34 children were included, with 17 cases (50%) having isolated NRAS mutations, 9 cases (27%) having isolated KRAS mutations, and 8 cases (24%) having compound mutations. Compared to children with isolated NRAS mutations, those with NRAS compound mutations showed statistically significant differences in age at onset, platelet count, and fetal hemoglobin proportion (P<0.05). Cox proportional hazards regression model analysis revealed that hematopoietic stem cell transplantation (HSCT) and hepatomegaly (≥2 cm below the costal margin) were factors affecting the survival rate of JMML children with RAS mutations (P<0.05); hepatomegaly was a factor affecting survival in the non-HSCT group (P<0.05).
CONCLUSIONS
Children with NRAS compound mutations have a later onset age compared to those with isolated NRAS mutations. At initial diagnosis, children with NRAS compound mutations have poorer peripheral platelet and fetal hemoglobin levels than those with isolated NRAS mutations. Liver size at initial diagnosis is related to the prognosis of JMML children with RAS mutations. HSCT can improve the prognosis of JMML children with RAS mutations.
Humans
;
Leukemia, Myelomonocytic, Juvenile/therapy*
;
Mutation
;
Male
;
Female
;
Child, Preschool
;
Retrospective Studies
;
Child
;
Infant
;
GTP Phosphohydrolases/genetics*
;
Membrane Proteins/genetics*
;
Adolescent
;
Hematopoietic Stem Cell Transplantation
;
Proportional Hazards Models
;
Proto-Oncogene Proteins p21(ras)/genetics*
;
Prognosis
10.Genetic screening and follow-up results in 3 001 newborns in the Yunnan region.
Ao-Yu LI ; Bao-Sheng ZHU ; Jin-Man ZHANG ; Ying CHAN ; Jun-Yue LIN ; Jie ZHANG ; Xiao-Yan ZHOU ; Hong CHEN ; Su-Yun LI ; Na FENG ; Yin-Hong ZHANG
Chinese Journal of Contemporary Pediatrics 2025;27(6):654-660
OBJECTIVES:
To evaluate the application value of genetic newborn screening (gNBS) in the Yunnan region.
METHODS:
A prospective study was conducted with a random selection of 3 001 newborns born in the Yunnan region from February to December 2021. Traditional newborn screening (tNBS) was used to test biochemical indicators, and targeted next-generation sequencing was employed to screen 159 genes related to 156 diseases. Positive-screened newborns underwent validation and confirmation tests, and confirmed cases received standardized treatment and long-term follow-up.
RESULTS:
Among the 3 001 newborns, 166 (5.53%) were initially positive for genetic screening, and 1 435 (47.82%) were genetic carriers. The top ten genes with the highest variation frequency were GJB2 (21.29%), DUOX2 (7.27%), HBA (6.14%), GALC (3.63%), SLC12A3 (3.33%), HBB (3.03%), G6PD (2.94%), SLC25A13 (2.90%), PAH (2.73%), and UNC13D (2.68%). Among the initially positive newborns from tNBS and gNBS, 33 (1.10%) and 47 (1.57%) cases were confirmed, respectively. A total of 48 (1.60%) cases were confirmed using gNBS+tNBS. The receiver operating characteristic curve analysis demonstrated that the areas under the curve for tNBS, gNBS, and gNBS+tNBS in diagnosing diseases were 0.866, 0.982, and 0.968, respectively (P<0.05). DeLong's test showed that the area under the curve for gNBS and gNBS+tNBS was higher than that for tNBS (P<0.05).
CONCLUSIONS
gNBS can expand the range of disease detection, and its combined use with tNBS can significantly shorten diagnosis time, enabling early intervention and treatment.
Humans
;
Infant, Newborn
;
Neonatal Screening
;
Genetic Testing
;
Female
;
Male
;
Follow-Up Studies
;
Prospective Studies
;
China

Result Analysis
Print
Save