1.Skeleton Binding Protein 1 of Plasmodium berghei Influences Deformability and Cytoskeletal Ultrastructure of Infected Erythrocyte
Xin-Yue GUO ; Huan-Qi ZHAO ; Yan-Xuan ZHONG ; Ru-Meng JIANG ; Yao-Xian LI ; Lei-Ting PAN ; Qian WANG ; Xiao-Yu SHI
Progress in Biochemistry and Biophysics 2026;53(4):1015-1027
ObjectiveThe malaria parasites remodel the host erythrocyte structure by exporting parasite proteins that interact with the membrane skeleton proteins of red blood cells (RBCs), facilitating their intracellular survival and pathogenicity. Skeleton-binding protein 1 (SBP1) is a conserved exported protein across Plasmodium species. In Plasmodium falciparum, SBP1 has been reported to interact with erythrocyte membrane skeleton proteins 4.1R and spectrin, while its contribution to erythrocyte remodeling and parasite virulence in Plasmodium berghei (Pb) remains unclear. This study aims to determine whether PbSBP1 associates with the host cytoskeletal protein 4.1R and to investigate its role in the remodeling of host RBCs and the pathogenicity of Plasmodium berghei. MethodsIn Plasmodium berghei, the relationship between PbSBP1 and the erythrocyte cytoskeletal protein 4.1R was examined using co-immunoprecipitation. A Pbsbp1 gene knockout mutant of Plasmodium berghei (Pbsbp1∆) was generated based on the principle of double crossover homologous recombination. The deformability of erythrocytes infected with Pbsbp1∆ parasites was assessed using microfluidic methods. Microchannels with an array of cylindrical pillars were used to detect modifications in infected RBC deformability. The infected RBCs were squashed between the rows and recovered between the columns and the transit velocity (μm/s) of infected RBCs travelling through the microchannel was recorded. The component of the erythrocyte membrane skeleton junctional complex, tropomodulin (TMOD), was fluorescently labeled, and the cytoskeletal network of infected erythrocytes was imaged using super-resolution stochastic optical reconstruction microscopy (STORM) to analyze ultrastructural changes in the cytoskeleton of wild-type (WT) and Pbsbp1∆-infected erythrocytes. Actin-based junctional complexes were displayed as individual clusters by the labeled TMOD in the STORM images, and the cluster densities and distances between adjacent clusters of infected RBCs were calculated. Additionally, rodent malaria models (BALB/c mice) and experimental cerebral malaria models (C57BL/6 mice) were employed to monitor the growth of Pbsbp1∆ and WT parasites during the intraerythrocytic stage and their capacity to induce cerebral malaria in mice. ResultsPbSBP1 may participate in the remodeling of infected erythrocytes through direct or indirect interaction with the erythrocyte cytoskeletal protein 4.1R. Microfluidic assays revealed that the deformability of erythrocytes infected with Pbsbp1∆ parasites was significantly enhanced compared to those infected with WT parasites. STORM imaging further demonstrated that the ultrastructure of the erythrocyte cytoskeleton in Pbsbp1∆-infected cells was altered relative to that in WT-infected erythrocytes. The distances between nearest neighbors of clusters had a tendency to increase while the cluster densities were decreased in Pbsbp1∆-infected RBCs compared to WT-infected RBCs. Subsequent phenotypic analysis indicated that the growth rate of Pbsbp1∆ parasites during the intraerythrocytic stage was significantly slower than that of WT parasites, and their ability to induce cerebral malaria in mice was also attenuated. These findings suggest that PbSBP1 is involved in the remodeling of the erythrocyte membrane skeleton, likely through its direct or indirect interaction with protein 4.1R, thereby regulating the deformability of infected erythrocytes and influencing the pathogenicity of the blood-stage parasites. ConclusionThis study establishes a role for PbSBP1 in host erythrocyte remodeling and parasite virulence, providing new research strategies for the prevention and treatment of malaria.
2.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
3.ESTABLISHMENT AND APPLICATION OF A MULTIPLEX PCR DETECTION METHOD FOR THREE COMMON PATHOGENS CAUSING DIARRHEA IN YAKS
Yao PAN ; Jing ZHANG ; Mei-Jun JIN ; Ling-Xiang XIN ; Hai-Yue XIAO ; Yan LIU ; Wen-Sheng YAO ; Chuan CHENG ; Li-Li HAO ; Lan LAN ; Liang-Quan ZHU
Acta Parasitologica et Medica Entomologica Sinica 2025;32(3):146-152
Objective To establish a rapid,sensitive,and specific multiplex PCR detection method for the simultaneous detection of Cryptosporidium,Eimeria,and bovine parvovirus.Methods Specific primers targeting the SSU rRNA genes of Cryptosporidium and Eimeria,as well as the VP2 gene of bovine parvovirus were designed and the corresponding recombinant plasmid standards were constructed.To establish the multiplex PCR method,the reaction conditions were optimized using temperature gradient PCR and single-variable control methods.The sensitivity,specificity,reproducibility,and clinical application of the protocol were evaluated.Results The optimal annealing temperature was found to be 60.5℃,and the forward and reverse primer concentrations were determined to be 0.2 μmol/L for Eimeria,and 0.4 μmol/L for Cryptosporidium and bovine parvovirus.The assay demonstrated high sensitivity,with detection limits of 243,260,and 3 110 copies for the recombinant plasmid standards of Cryptosporidium,Eimeria,and bovine parvovirus,respectively.Specificity testing showed no cross-reactivity with ten common bovine pathogens,including Salmonella,bovine viral diarrhea virus,and bovine rotavirus.Consistent intra-and inter-batch results confirmed the strong reproducibility of the method.Clinical application to 81 diarrhea samples from various regions in the Ganzi Prefecture,Sichuan,revealed positivity rates of 18.52%(15/81)for Cryptosporidium,34.57%(28/81)for Eimeria,and 18.52%(15/81)forbovineparvovirus,withamixedinfectionrateof3.7%(3/81).Conclusions Themultiplex PCR method established in this study offers a reliable tool for differential diagnosis and epidemiological investigation of the three common diarrheal pathogens in yaks.
4.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
5.High-sensitivity Ratio-type Surface-enhanced Raman Substrate for Rapid Quantitative Determination of 6-Thioguanine in Serum
Yan-Bin LIU ; Yi-Chao HAN ; Rong WANG ; Xiao-Mei WU ; Qin WANG ; Yuan-Yuan YAO ; Yue-Liang WANG ; Long-Hua GUO
Chinese Journal of Analytical Chemistry 2025;53(8):1300-1310
6-Thioguanine(6-TG)is an antineoplastic agent used in treatment of acute leukemia.However,significant interindividual variability in dosing regimens and frequent clinical manifestations of hepatotoxicity and myelosuppression as adverse effects have affected its therapeutic efficacy.Consequently,the development of rapid analytical methods for 6-TG in clinical samples,enabling continuous therapeutic drug monitoring of plasma concentrations,holds substantial significance in optimizing dosage regimens,mitigating adverse reactions,and investigating drug metabolism mechanisms.In this study,multi-tipped gold nanostars(AuNSs)were prepared.With bis-(p-sulfonylphenyl)phenylphosphine molecule as the protecting agent and internal standard molecule,the AuNSs were assembled onto a highly sensitive surface-enhanced Raman(SERS)substrate for developing a ratio-based SERS quantitative analysis method for 6-TG in serum.The AuNSs containing multiple tips and gaps exhibited strong local surface plasmon resonance effect and SERS activity,ensuring the sensitivity of the analytical method.Furthermore,the introduction of internal standard molecules could improve the reproducibility,which guaranteed this method suitable for rapid analysis of drug molecules in complex samples.Quantitative analysis of 6-TG was achieved with linear detetion range of 1.0×10?4-1.0 mmol/L.In the spiked recovery experiments of serum,the RSD was less than 5.32%,and the recoveries were 94%-104%,which proved that this method could be used for rapid quantitative determination of 6-TG in serum.This method provided a powerful tool for studying drug pharmacokinetics,which could promote the optimization of the usage methods of anti-cancer drugs,and it was expected to further enhance the clinical efficacy and safety of 6-TG,enabling it to achieve the best therapeutic effect.
6.Analysis on noise hazard characteristics of key industries workplaces in Huizhou City
Zhuocheng YAO ; Guoyong XU ; Jianyu GUO ; Weilan YAN ; Haijie LIN ; Xi ZHOU ; Bin XIAO
China Occupational Medicine 2025;52(5):579-584
Objective To understand the characteristics of occupational noise hazards in key industries in Huizhou City. Methods A total of 247 enterprises from 13 key industries in Huizhou City were selected as the research subjects using the stratified judgment sampling method. The worksite survey of occupational health and workplace noise intensity and spectrum monitoring were conducted at key work sites using "questionnaires and on-site inspections" method. Results The rate of noise intensity exceeding national standards was 53.4% (132/247). The median, 25th and 75th percentile of noise pressure levels in workplaces and worksites were 85.1 (81.2, 91.2)and 82.5 (78.8, 86.3) dB(A), respectively. The high-noise workplaces accounted for 50.0% (479/958). The rate of noise intensity exceeding national standard at work sites was 32.9% (303/921). The sound pressure level of noise at work sites was positively correlated with sound pressure level of noise sources (Spearman correlation coefficient=0.73, P<0.01). The top three high-risk work sites for exceeding national noise standards were grinding, frame nailing, and material cutting, with exceedance rates of 84.6%, 81.3%, and 62.8%, respectively. The frequency characteristics of the top ten high-risk work sites were mainly high-frequency noise. There were significant differences in noise spectrum characteristics among different workpiece materials used in similar types of work sites (all P<0.05), though high-frequency noise remained dominant. Conclusion Noise hazards in workplaces of key industries in Huizhou City are relatively severe. Continuous attention should be given to key work sites with high over-standard rate, such as grinding, frame nailing, and material cutting, and noise control strategies should be developed based on frequency spectrum characteristics.
7.Antimicrobial resistance surveillance in the bacterial strains isolated from pediatric intensive care units in China:results from 2020 to 2022
Jing LIU ; Huiyuan YAN ; Gangfeng YAN ; Guoping LU ; Pan FU ; Chuanqing WANG ; Danqun JIN ; Wenjia TONG ; Chenyu ZHANG ; Jianli CHEN ; Yi LIN ; Jia LEI ; Yibing CHENG ; Qunqun ZHANG ; Kaijie GAO ; Yuanyuan CHEN ; Shufang XIAO ; Juan HE ; Li JIANG ; Huimin XU ; Yuxia LI ; Hanghai DING ; Hehe CHEN ; Yao ZHENG ; Qunying CHEN ; Ying WANG ; Hong REN ; Chenmei ZHANG ; Zhenjie CHEN ; Mingming ZHOU ; Yucai ZHANG ; Yiping ZHOU ; Zhenjiang BAI ; Saihu HUANG ; Lili HUANG ; Weiguo YANG ; Weike MA ; Qing MENG ; Pengwei ZHU ; Yong LI ; Yan XU ; Yi WANG ; Yanqiang DU ; Huijun CAI ; Bizhen ZHU ; Huixuan SHI ; Shaoxian HONG ; Yukun HUANG ; Meilian HUANG
Chinese Journal of Infection and Chemotherapy 2025;25(3):303-311
Objective This study aimed to investigate the antimicrobial resistance profiles of bacterial strains isolated from pediatric intensive care units(PICU)in China for better antimicrobial therapy.Methods Clinical isolates were collected from 17 institutions,including tertiary care children's hospitals and pediatric department of tertiary general hospitals in China from January 1,2020 to December 31,2022.Antimicrobial susceptibility testing was carried out according to a unified protocol using Kirby-Bauer method or automated systems.Results were interpreted according to the breakpoints released by the Clinical and Laboratory Standards Institute(CLSI)in 2020.Results A total of 10 688 isolates were collected,including gram-positive organisms(39.2%)and gram-negative organisms(60.8%).The top three organisms were S.aureus(13.6%,1 453/10 688),A.baumannii(10.0%,1 067/10 688),and coagulase-negative Staphylococcus(9.9%,1 058/10 688).Multi-drug resistant organisms(MDROs)were very common in children.The prevalence of methicillin-resistant Staphylococcus aureus(MRSA),carbapenem-resistant Enterobacterales(CRE),carbapenem-resistant E.coli,carbapenem-resistant K.pneumoniae(CRKP),carbapenem-resistant A.baumannii(CRAB),and carbapenem-resistant P.aeruginosa(CRPA)was 41.1%,19.4%,8.8%,30.9%,67.4%,and 28.8%,respectively.Overall,more than 50%of Enterobacteriales isolates were resistant to cephalosporins,while nearly 25%of Enterobacteriales isolates were resistant to carbapenems.MDROs were highly resistant to commonly used antibiotics.More than 80%of CRE and CRAB strains were resistant to all beta-lactam antibiotics.CRE and CRAB showed low resistance rates to tigecycline and polymyxin.CRPA showed lower resistance rates to piperacillin,beta-lactamase inhibitor combinations than the resistance rates to third and fourth generation cephalosporins.All of the Staphylococcus and Enterococcus isolates were susceptible to vancomycin and tigecycline.None of PRSP strains isolated from meningitis and nonmeningitis samples were resistant to rifampicin,vancomycin,or linezolid.The prevalence of β-lactamase-negative ampicillin-resistant(BLNAR)strains was 43.3%in Haemophilus influenzae.Conclusions MDROs were prevalent in PICU.It is necessary to establish an effective multidisciplinary team(MDT)to control the antimicrobial resistance.
8.Correlation between Serum Ferritin Levels and the Efficacy of Platelet Transfusion in Patients with Malignant Hematological Diseases
Yi-Yao LI ; Xiao-Yun GAO ; Hang GUAN ; Yu BAI ; Jun-Hui JIA ; Wei BAI ; Yan-Hui DI ; Hua TIAN ; Li-Duo KOU ; Xin-Hua WANG
Journal of Experimental Hematology 2025;33(6):1779-1783
Objective:To explore the correlation between serum ferritin(SF)levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Methods:Patients with malignant hematological diseases who received repeated transfusions of apheresis platelets in Department of Hematology of Aerospace Center Hospital in 2023 were selected.The platelet corrected count increment(CCI)was used to evaluate the efficacy of platelet transfusion.The correlations between sex,age,disease type,transplantation history,red blood cell transfusion history,and SF level and the efficacy of platelet transfusion were analyzed.Results:A total of 87 patients were included,with a cumulative 326 person-times platelet transfusions.As suggested by one-way analysis of variance,compared with the patients in the age groups of 24-45 years old and 46-66 years old,the patients in the age group of 2-23 years old had a better efficacy of platelet transfusion(P=0.004,P=0.004).There was no significant difference in the efficacy of platelet transfusion between the patients in the age group of 24-45 years old and those in the age group of 46-66 years old(P=0.876).Compared with the patients who had a history of red blood cell transfusion within 3 days,the patients without a history of red blood cell transfusion within 3 days had a better efficacy of platelet transfusion(P<0.001).Compared with the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L,the group with SF levels<1.44 ng/L had a better efficacy of platelet transfusion(P=0.028,P<0.001).Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).After adjusting for age and the history of red blood cell transfusion,the transfusion efficacy of the group with SF levels<1.44 ng/L was better than that of the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L(P=0.021,P<0.001);Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).Both univariate and multivariate linear regression models showed that SF levels were negatively correlated with the efficacy of platelet transfusion(P<0.001).Conclusion:There is a negative correlation between SF levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Detection of SF levels may provide guidance for predicting the efficacy of platelet transfusion.
9.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
10.Clinical efficacy of minimally invasive tendon blade technique in the treatment of moderate and severe gluteal muscle contracture.
Jia-Kai GAO ; Tao-Ran WANG ; Long BI ; Xiao-Chao CHEN ; Yan-Wu LIU ; Yao-Ping WU ; Xiang HE ; Zhi-Xia NIU
China Journal of Orthopaedics and Traumatology 2025;38(4):420-423
OBJECTIVE:
To investigate the clinical effect of minimally invasive technique in the treatment of moderate and severe gluteal muscle contracture.
METHODS:
A retrospective study was conducted on 85 patients (170 sides) with bilateral gluteal muscle contracture admitted from January 2016 to December 2019. All patients were treated with minimally invasive release of tendon knife. There were 32 males and 53 females, ranging in age from 15 to 37 years old, with an average age of (22.3±6.3) years old. Operation time, intraoperative blood loss, incision length, first postoperative ambulation time, complication rate, recurrence rate, and Harris hip score (HHS) were analyzed and evaluated.
RESULTS:
The average follow-up time was (16.2±4.6) months, ranging from 12 to 30 months. The operation time ranged from 7 to 15 min, with an average of (10.2±3.1) min. Intraoperative blood loss ranged from 2 to 20 ml, with an average of (8.4±2.2) ml. The incision length ranged from 0.6 to 2.0 cm, with an average of (0.8±0.3) cm. The time to postoperative ambulation ranged from 12 to 28 h, with an average of (20.0±3.2) h. All patients achieved primary wound healing without sciatic nerve injury or recurrence. HHS hip function scores ranged from 90 to 98, with an average score of (96.2±1.4). Complications included intraoperative tendon blade tip fracture in two cases (removed under fluoroscopic guidance) and subcutaneous hematoma in three cases-two resolved with compression and one with open evacuation.. Twenty-nine patients exhibited transient swaying gait postoperatively, of which 24 patients returned to normal after 4 weeks and 5 patients returned to normal after 6 weeks.
CONCLUSION
Minimally invasive tendon blade release is a safe and effective technique for treating gluteal muscle contracture, offering minimal trauma, rapid recovery, and excellent cosmetic and functional outcomes. However, it exhibits a low risk of blade tip fracture and sciatic nerve injury, warranting experienced surgical handling.
Humans
;
Male
;
Female
;
Adult
;
Minimally Invasive Surgical Procedures/methods*
;
Adolescent
;
Retrospective Studies
;
Buttocks/surgery*
;
Young Adult
;
Contracture/surgery*
;
Tendons/surgery*
;
Muscle, Skeletal/surgery*


Result Analysis
Print
Save
E-mail