1.Labial protuberances of anterior alveolar bone in orthodontic treatment: a case report and literature review
ZHOU Wei ; TANG Ya ; XIAO Jianping ; HAO Jing ; TAN Baochun
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(5):393-400
Objective:
This study aims to explore the influencing factors, formation mechanisms, and treatment methods of labial protuberance in the anterior maxilla during orthodontic treatment, providing a reference for clinical practice.
Method:
This study reports a case where the absence of upper anterior teeth 11 and 21, and the retraction tilting movement of teeth 12 and 22, resulted in labial protuberance and gingival hyperplasia. Alveolar osteoplasty and gingivoplasty were performed. The specific changes in the alveolar bone during the retraction of the anterior teeth and the characteristics of its remodeling were analyzed. Combined with relevant literature, the factors influencing the formation of labial protuberance in orthodontic patients, mechanisms, and methods for prevention and treatment were summarized.
Results:
After periodental surgery follow-up for 6 months, the gingival color and shape of teeth 12 and 22 were good, the labial alveolar bone was normal, and the overall condition was stable. A review of the literature showed that labial protuberance is more common in adult orthodontic patients, and the distance (>4 mm) and speed of retraction of anterior teeth are related to its formation, with the main mechanism likely being differential remodeling of the alveolar bone. In adult patients, the number of active osteoblasts and osteoclasts in the alveolar bone decreases, along with a reduction in metabolic activity and overall cellular activity, which diminishes the reactivity of the alveolar bone. After treatment of anterior teeth retraction, there is insufficient labial bone resorption. Moreover, the lack of mechanical stress-mediated periodontal ligament in the interdental space leads to reduced bone remodeling stimulation in this area, resulting in thickening of the labial alveolar bone of the upper anterior teeth. The remodeling rates of cortical and trabecular bone differ, with active trabecular bone proliferation near the tooth root surface and slow cortical bone resorption near the outer surface, which ultimately results in increased bone thickness at the labial cervical region. Specific case analysis indicates that the retraction distance of the upper anterior teeth in this case was about 6 mm. The alveolar bone at the missing sites of teeth 11 and 21, lacking periodontal ligament stimulation, showed less remodeling and absorption, likely appearing as hyperplasia. The prevention of labial bone protrusion mainly involves controlling the speed and distance of retraction of anterior teeth. Smaller labial protuberances generally do not require treatment, but those affecting function and aesthetics can be addressed with periodontal alveolar osteoplasty.
Conclusion
After the retraction of anterior teeth in orthodontics, a prominent, hard bone protuberance on the labial side can sometimes occur, which may be due to differential remodeling efficiency in different regions of the alveolar bone. For bone protuberance that influences aesthetics or function, periodontal alveolar osteoplasty can be a reliable option.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Histaminergic Innervation of the Ventral Anterior Thalamic Nucleus Alleviates Motor Deficits in a 6-OHDA-Induced Rat Model of Parkinson's Disease.
Han-Ting XU ; Xiao-Ya XI ; Shuang ZHOU ; Yun-Yong XIE ; Zhi-San CUI ; Bei-Bei ZHANG ; Shu-Tao XIE ; Hong-Zhao LI ; Qi-Peng ZHANG ; Yang PAN ; Xiao-Yang ZHANG ; Jing-Ning ZHU
Neuroscience Bulletin 2025;41(4):551-568
The ventral anterior (VA) nucleus of the thalamus is a major target of the basal ganglia and is closely associated with the pathogenesis of Parkinson's disease (PD). Notably, the VA receives direct innervation from the hypothalamic histaminergic system. However, its role in PD remains unknown. Here, we assessed the contribution of histamine to VA neuronal activity and PD motor deficits. Functional magnetic resonance imaging showed reduced VA activity in PD patients. Optogenetic activation of VA neurons or histaminergic afferents significantly alleviated motor deficits in 6-OHDA-induced PD rats. Furthermore, histamine excited VA neurons via H1 and H2 receptors and their coupled hyperpolarization-activated cyclic nucleotide-gated channels, inward-rectifier K+ channels, or Ca2+-activated K+ channels. These results demonstrate that histaminergic afferents actively compensate for Parkinsonian motor deficits by biasing VA activity. These findings suggest that targeting VA histamine receptors and downstream ion channels may be a potential therapeutic strategy for PD motor dysfunction.
Animals
;
Histamine/metabolism*
;
Male
;
Oxidopamine/toxicity*
;
Rats
;
Ventral Thalamic Nuclei/physiopathology*
;
Rats, Sprague-Dawley
;
Disease Models, Animal
;
Parkinson Disease/metabolism*
;
Neurons/physiology*
;
Humans
;
Optogenetics
7.Development of a machine learning-based risk prediction model for mild cognitive impairment with spleen-kidney deficiency syndrome in the elderly.
Ya-Ting AI ; Shi ZHOU ; Ming WANG ; Tao-Yun ZHENG ; Hui HU ; Yun-Cui WANG ; Yu-Can LI ; Xiao-Tong WANG ; Peng-Jun ZHOU
Journal of Integrative Medicine 2025;23(4):390-397
OBJECTIVE:
As an age-related neurodegenerative disease, the prevalence of mild cognitive impairment (MCI) increases with age. Within the framework of traditional Chinese medicine, spleen-kidney deficiency syndrome (SKDS) is recognized as the most frequent MCI subtype. Due to the covert and gradual onset of MCI, in community settings it poses a significant challenge for patients and their families to discern between typical aging and pathological changes. There exists an urgent need to devise a preliminary diagnostic tool designed for community-residing older adults with MCI attributed to SKDS (MCI-SKDS).
METHODS:
This investigation enrolled 312 elderly individuals diagnosed with MCI, who were randomly distributed into training and test datasets at a 3:1 ratio. Five machine learning methods, including logistic regression (LR), decision tree (DT), naive Bayes (NB), support vector machine (SVM), and gradient boosting (GB), were used to build a diagnostic prediction model for MCI-SKDS. Accuracy, sensitivity, specificity, precision, F1 score, and area under the curve were used to evaluate model performance. Furthermore, the clinical applicability of the model was evaluated through decision curve analysis (DCA).
RESULTS:
The accuracy, precision, specificity and F1 score of the DT model performed best in the training set (test set), with scores of 0.904 (0.845), 0.875 (0.795), 0.973 (0.875) and 0.973 (0.875). The sensitivity of the training set (test set) of the SVM model performed best among the five models with a score of 0.865 (0.821). The area under the curve of all five models was greater than 0.9 for the training dataset and greater than 0.8 for the test dataset. The DCA of all models showed good clinical application value. The study identified ten indicators that were significant predictors of MCI-SKDS.
CONCLUSION
The risk prediction index derived from machine learning for the MCI-SKDS prediction model is simple and practical; the model demonstrates good predictive value and clinical applicability, and the DT model had the best performance. Please cite this article as: Ai YT, Zhou S, Wang M, Zheng TY, Hu H, Wang YC, Li YC, Wang XT, Zhou PJ. Development of a machine learning-based risk prediction model for mild cognitive impairment with spleen-kidney deficiency syndrome in the elderly. J Integr Med. 2025; 23(4): 390-397.
Humans
;
Cognitive Dysfunction/diagnosis*
;
Aged
;
Male
;
Female
;
Machine Learning
;
Spleen
;
Aged, 80 and over
;
Kidney
;
Medicine, Chinese Traditional
9.Correlation of corneal α angle and κ angle with lens tilt angle using swept-source optical biometry
Zi-Suo LI ; Zi-Han HE ; Jie ZHOU ; Jian-Feng ZHAO ; Xiao-Ling LUO ; Ya-Li FENG ; Chen YANG ; Yu GENG
Medical Journal of Chinese People's Liberation Army 2025;50(9):1083-1088
Objective To investigate the correlation of corneal α angle and κ angle with lens tilt in normal human eyes using a new swept-source optical biometer.Methods A cross-sectional study was conducted,involving 303 healthy eyes(148 right eyes and 155 left eyes)of patients who visited the First Affiliated Hospital of Kunming Medical University from June to August 2024.ZW-30 swept-source optical biometer was used to collect the lens tilt angle,κ angle(distance from the corneal light reflex to the pupil center),and α angle(distance from corneal light reflex to the corneal geometric center,which is the midpoint of the horizontal white to white(WTW)diameter).The degrees(°)and directions of κ angle and α angle were calculated by the ratio of the above measurements to the anterior chamber depth(ACD)respectively.Spearman correlation analysis and linear regression analysis were employed to evaluate the correlations between the magnitude and direction of corneal α angle,κ angle and lens tilt angle.Results The magnitude and direction of corneal α angle,κ angle,and lens tilt angle in the right eye were as follows respectively:(0.54±0.19)mm(7.81°±3.88°),194.43°±39.75°;(0.27±0.23)mm(4.72°±3.90°),181.07°±79.59°;5.52°±1.67°,188.21°±25.73°.For the left eye,the corresponding values were:(0.47±0.27)mm(8.12°±5.26°),336.04°±46.64°;(0.26±0.27)mm(4.45°±4.80°),322.86°±107.79°;5.50°±1.61°,340.65°±32.84°.Spearman's correlation analysis showed that the correlation coefficients between corneal α angle and lens tilt angle in the right eye were 0.609(distance correlation)and 0.625(angle correlation),while those for κ angle were 0.559(distance correlation)and 0.578(angle correlation).In the left eye,the correlation coefficients between corneal α angle and lens tilt angle were 0.545(distance correlation)and 0.552(angle correlation),and those for κ angle were 0.377(distance correlation)and 0.395(angle correlation).In addition,the correlation coefficient between the direction of corneal α angle and the direction of lens tilt angle in the right eye was 0.343,and that for κ angle direction was 0.284;in the left eye,the correlation coefficients were 0.216(α angle direction)and 0.198(κ angle direction),all with statistical significance(P<0.05).Univariate linear regression analysis showed that lens tilt was positively correlated with both corneal α angle and Kappa angle(P<0.05).Conclusions Corneal α angle and κ angle are highly correlated with lens tilt angle in both eyes,and the correlation of corneal α angle is stronger than that of κ angle in both left and right eyes.The correlation expressed by degree(°)is better than that by distance(mm).It is recommended to refer to the corneal α angle and κ angle expressed in degrees during preoperative evaluation.
10.Quality changes of volatile oil and chlorogenic acid compounds during extraction process of Artemisiae Argyi Folium: process analysis based on chemical composition, physicochemical properties, and biological activity.
Dan-Dan YANG ; Hao-Zhou HUANG ; Xin-Ming CHEN ; Lin HUANG ; Ya-Nan HE ; Zhen-Feng WU ; Xiao-Ming BAO ; Ding-Kun ZHANG ; Ming YANG
China Journal of Chinese Materia Medica 2025;50(11):3001-3012
To explore the variation laws of volatile oil during the extraction process of Artemisiae Argyi Folium and its impact on the quality of the medicinal solution, as well as to achieve precise control of the extraction process, this study employed headspace solid phase microextraction gas chromatography-mass spectrometry(HS-SPME-GC-MS) in combination with multiple light scattering techniques to conduct a comprehensive analysis, identification, and characterization of the changes in volatile components and the physical properties of the medicinal solution during the extraction process. A total of 82 volatile compounds were identified using the HS-SPME-GC-MS technique, including 21 alcohols, 15 alkenes, 14 ketones, 9 acids, 6 aldehydes, 5 phenols, 3 esters, and 9 other types of compounds. At different extraction time points(15, 30, 45, and 60 min), 71, 72, 64, and 44 compounds were identified in the medicinal solution, respectively. It was observed that the content of volatile components gradually decreased with the extension of extraction time. Through multivariate statistical analysis, four compounds with significant differences during different extraction time intervals were identified, namely 1,8-cineole, terpinen-4-ol, 3-octanone, and camphor. RESULTS:: from multiple light scattering techniques indicated that at 15 minutes of extraction, the transmittance of the medicinal solution was the lowest(25%), the particle size was the largest(0.325-0.350 nm), and the stability index(turbiscan stability index, TSI) was the highest(0-2.5). With the extension of extraction time, the light transmittance of the medicinal solution improved, stability was enhanced, and the particle size decreased. These laws of physicochemical property changes provide important basis for the control of Artemisiae Argyi Folium extraction process. In addition, the changes in the bioactivity of Artemisiae Argyi Folium extracts during the extraction process were investigated through mouse writhing tests and antimicrobial assays. The results indicated that the analgesic and antimicrobial effects of the medicinal solution were strongest at the 15-minute extracting point. In summary, the findings of this study demonstrate that the content of volatile oil in Artemisiae Argyi Folium extracts gradually decreases with the extension of extraction time, and the variation in volatile oil content directly influences the physicochemical properties and pharmacological efficacy of the medicinal solution. This discovery provides important scientific reference for the optimization of Artemisiae Argyi Folium extraction processes and the development and application of process analytical technologies.
Oils, Volatile/pharmacology*
;
Artemisia/chemistry*
;
Gas Chromatography-Mass Spectrometry
;
Drugs, Chinese Herbal/pharmacology*
;
Chlorogenic Acid/pharmacology*
;
Solid Phase Microextraction
;
Quality Control


Result Analysis
Print
Save
E-mail