1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.A case of transcatheter edge-to-edge repair performed on a patient with severe atrial functional mitral and tricuspid regurgitation
Yi-jiang ZHOU ; Wei-cong XIA ; Kai WANG ; Jun LI ; Ya-wei CUI ; Kai-li WANG ; Yun MOU ; KUSHANI·REYIHAN ; Xiao-gang GUO
Chinese Journal of Interventional Cardiology 2025;33(4):236-240
Persistent atrial fibrillation and other factors can cause mitral and tricuspid annular dilation and leaflet regurgitation,leading to severe functional mitral and tricuspid regurgitation.Patients often experience significant heart failure symptoms and poor prognosis.For patients with severe mitral or tricuspid regurgitation who are at high risk or contraindicated for surgical procedures,transbronchial repair(TEER)is an important alternative therapy that can effectively reduce valve regurgitation and improve cardiac function;Although there is a lack of large-scale data on atrial functional reflux,existing experience still shows that TEER can significantly reduce reflux and improve patients'quality of life.However,double valve intervention therapy poses challenges,especially when combined with TEER repair,which is technically more complex,time-consuming,and carries higher risks.Foreign data shows that simultaneous or staged double valve intervention can safely improve cardiac function and increase survival rates,but the optimal intervention strategy still needs further research.Due to the fact that tricuspid TEER devices have not yet been launched in China,only staged treatment can be adopted at present.This case report shows a patient with severe atrial functional mitral and tricuspid regurgitation who underwent staged transcatheter edge to edge repair surgery successfully.During a 1-year follow-up,bilateral valve regurgitation continued to improve,indicating that staged repair of bilateral atrioventricular valve regurgitation through the catheter margin is a feasible and effective treatment option.
3.A case of transcatheter edge-to-edge repair performed on a patient with severe atrial functional mitral and tricuspid regurgitation
Yi-jiang ZHOU ; Wei-cong XIA ; Kai WANG ; Jun LI ; Ya-wei CUI ; Kai-li WANG ; Yun MOU ; KUSHANI·REYIHAN ; Xiao-gang GUO
Chinese Journal of Interventional Cardiology 2025;33(4):236-240
Persistent atrial fibrillation and other factors can cause mitral and tricuspid annular dilation and leaflet regurgitation,leading to severe functional mitral and tricuspid regurgitation.Patients often experience significant heart failure symptoms and poor prognosis.For patients with severe mitral or tricuspid regurgitation who are at high risk or contraindicated for surgical procedures,transbronchial repair(TEER)is an important alternative therapy that can effectively reduce valve regurgitation and improve cardiac function;Although there is a lack of large-scale data on atrial functional reflux,existing experience still shows that TEER can significantly reduce reflux and improve patients'quality of life.However,double valve intervention therapy poses challenges,especially when combined with TEER repair,which is technically more complex,time-consuming,and carries higher risks.Foreign data shows that simultaneous or staged double valve intervention can safely improve cardiac function and increase survival rates,but the optimal intervention strategy still needs further research.Due to the fact that tricuspid TEER devices have not yet been launched in China,only staged treatment can be adopted at present.This case report shows a patient with severe atrial functional mitral and tricuspid regurgitation who underwent staged transcatheter edge to edge repair surgery successfully.During a 1-year follow-up,bilateral valve regurgitation continued to improve,indicating that staged repair of bilateral atrioventricular valve regurgitation through the catheter margin is a feasible and effective treatment option.
4.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]
5.Design and performance verification of high altitude adaptive oxygen generator
Bo WANG ; Xiao-feng LIU ; Wen-jia LIU ; Yi LI ; Ya-nan WU ; Shu-jie CUI ; Wei ZHANG
Chinese Medical Equipment Journal 2025;46(4):29-34
Objective To design a high altitude adaptive oxygen generator for the crews to alleviate their high altitude reaction in high altitude environment and meet their requirements for oxygen supply.Methods A high altitude adaptive oxygen generator based on the mature pressure swing adsorption oxygen production method was designed with the key technologies of discharge capacity compensation of air compression pump and airway fusion of molecular sieve tower,which had the components of molecular sieve tower,air compression pump,controller,cooling fan,cooler,solenoid valve,regulator,flow meter and etc.Trials were carried out at the simulated altitude and field plateau environment so as to verify the high altitude adaptive performance of the oxygen generator developed.Results The trial results showed the oxygen generator met the desired objectives and the requirements for oxygen volume fraction in GJB 2799-1996 General specification for medical oxygen generator using molecular sieve method.Conclusion The oxygen generartor provides oxygen supply effectively for vehicle operators in plateau environments or the ones rushing into the plateau.[Chinese Medical Equipment Journal,2025,46(4):29-34]
6.Effect of fasting blood glucose on coronary fractional flow reserve in patients with borderline coronary artery disease
Yi-wen ZHANG ; Ya-dong LIU ; Meng-xiao WANG ; Yi-ru WANG ; Yun-peng YANG ; Yun-fang SU ; Ji-xin ZHI
Chinese Journal of Interventional Cardiology 2025;33(5):272-277
Objective To explore the correlation between fasting blood glucose(FBG)level and fractional flow reserve(FFR)in patients with borderline coronary artery disease,and to clarify its potential influence on FFR measurement.Methods From August 2020 to August 2023,the data of 135 patients with coronary atherosclerotic heart disease who received coronary angiography and FFR evaluation in the Fourth Affiliated Hospital of Harbin Medical University were retrospectively collected.According to the exclusion and inclusion criteria,85 cases of borderline diseased vessels of single coronary artery with stenosis degree of 50%-80%were screened out,and they were divided into FBG≥6.1 mmol/L group(47 cases)and FBG<6.1 mmol/L group(38 cases).The baseline data,angiographic and functional indexes of the two groups were compared,and the correlation between FBG and FFR was analyzed.Results Compared with the FBG<6.1 mmol/L group,the FBG≥6.1 mmol/L group had a higher proportion of FFR negative results(72.3%vs.23.7%,P<0.001),and the FFR measurement values were generally increased[0.84(0.80,0.90)vs.0.75(0.68,0.80),P<0.001],with statistically significant differences.Pearson correlation analysis was performed on all lesions,and FFR>0.80(negative result)was positively correlated with FBG≥6.1 mmol/L(r=0.484,P<0.001).Conclusions Among the patients with borderline coronary artery disease(50%-80%stenosis)included in this study,FBG≥6.1 mmol/L is significantly correlated with FFR>0.80.For patients with borderline coronary lesions with elevated FBG,the influence of blood glucose factors should be carefully considered in clinical interpretation of FFR results.
7.Mechanism of adipose mesenchymal stem cell exosomes inhibiting atopic dermatitis
Jia-qi BI ; Zhao WANG ; Bing-kun WANG ; Chun-yan SUN ; Ya SUN ; Xiao-tong CUI ; Xin PANG ; Xiao-yu WANG ; Jie-qiong WANG
Chinese Pharmacological Bulletin 2025;41(6):1148-1157
Aim To study the mechanism of adipose mesenchymal stem cell exosomes(ASC-exo)inhibition of fluorescein isothiocyanate(FITC)-induced atopic dermatitis(AD).Methods The mouse age,extrac-tion method,and the concentration of a solution of typeⅠ collagen enzyme and other conditions were compared to study the effects on the morphology and quantity of adipose mesenchymal stem cells(ASCs)after extrac-ted.FITC-induced mouse model in vivo was estab-lished and different doses of ASC-exo were given to measure ear thickness,ear weight and ear scratching times of mice.HE staining was used to observe the pathological changes of ear tissue of mice.The non-toxicity of ASC-exo was detected.IgE,IL-5,IL-13 and other cytokines were detected by ELISA.The gene ex-pressions of TSLP,IL-33,occludin,Claudin-1(CLDN-1)and E-cadherin were detected by RT-qPCR.The protein expression was detected by immunohistochemis-try.Results An efficient method for extracting ASCs was established.Compared with the blank group,mice in the model group showed obvious AD symptoms.Compared with the model group,ASC-exo administra-tion group significantly reduced the number of ear scratches,epidermal thickening,inflammatory cell infil-tration and the secretion of Th2 cytokines IL-5 and IL-13.Meanwhile,ASC-exo administration group signifi-cantly increased the expression of structural proteins CLDN-1 and occludin in epithelial cells and decreased the expression of TSLP and IL-33.Conclusions ASC-exo can significantly improve Th2 skin inflamma-tion in AD mice,and its mechanism may be through in-creasing the expression of tight junction proteins and adhesion link protein in epithelial cells,repairing the skin barrier,and inhibiting the key promoters of allergy TSLP and IL-33.
8.Analysis of dosimetric verification results of intensity-modulated radiotherapy for breast cancer based on EPID fraction images
Xiao-hui WU ; Ya-zheng CHEN ; Zu-wen YAO ; Rui LIU ; Yang LIU ; Xiao-hua WANG
Chinese Medical Equipment Journal 2025;46(6):54-58
Objective To investigate the stability and reproducibility of the treatment fractions during the intensity-modulated radiotherapy(IMRT)for breast cancer and the effect of respiratory motion on the dose irradiation of breast cancer radiotherapy by comparing the results of breast cancer dosimetric verification based on fractionated images by an electronic portal imaging device(EPID).Methods A total of 28 IMRT patients admitted to some hospital from January to June 2023 were grouped according to the pathological results and effects of respiratory motion on the accuracy of radiotherapy during clinical treatment,including 14 cases in a breast group and 14 cases in a non-breast group with 8 ones of head and neck tumors,5 ones of esophageal cancer and 1 case of cervical cancer.All the patients underwent a scan with cone beam computed tomography(CBCT)before the first radiotherapy,and image registration was carried out with a positioning CT.An EPID was used to acquire transmission dose images of 10 fractions of radiotherapy,and γ analysis was performed using the RIT 113 QA software to compare the images of the subsequent 9 fractions with those of the first fraction,with the images of the first fraction of radiotherapy as the baseline values.Absolute maximum dose normalization was implemented under the condition of 10%dose assessment threshold,and the γ-pass rates under the 3 criteria of 2%/2 mm,3%/2 mm and 3%/3 mm were counted separately.The fraction dose verification results of the 28 patients were divided into 3 treatment phases of 2-4 times(T1),5-7 times(T2)and 8-10 times(T3)to analyze the stability of dose irradiation during the radiotherapy.SPSS 22.0 software was used for statistical analysis.Results Under the condition of 10%dose assessment threshold,the breast and non-breast groups had the γ-pass rates being(95.80±2.65)%and(94.60±6.59)%under the 2%/2 mm criterion and(98.46±1.31)%and(97.50±3.30)%under the 3%/2 mm criterion respectively,and the differences were statistically significant(all P<0.05).Under the assessment criteria of 2%/2 mm,3%/2 mm and 3%/3 mm,the breast group had the γ-pass rates of fractions of treatment significantly lower than those of the non-breast group(all P<0.05),while the γ-pass rates showed no significant differences at T1,T2 and T3 treatment phases(all P>0.05).Conclusion EPID fraction images contribute to evaluating IMRT accuracy effectively.IMRT has high stability and reproducibility during the treatment cycle,while respiration may result in dose deviation during the fraction radiotherapy for breast cancer,and optical surface tracking technology or active breathing control technology is suggested to be involved in to relieve dose deviation.[Chinese Medical Equipment Journal,2025,46(6):54-58]
9.Present situation of sensors applied to monitoring of spinal morphology and motion
Shi-yu ZHOU ; Ya-qin LI ; Yang-xi HUANG ; Xiao CHEN ; Jing WANG ; Zhi-min LIANG ; Yu-chen GUO ; Xue YANG ; Ling-li LI
Chinese Medical Equipment Journal 2025;46(6):105-110
The application of sensors to the monitoring of spinal morphology and motion was reviewed in terms of the research object and monitoring index.The present situation of the application of sensors was introduced,such as inertial sensor,stretchable strain sensor and electromagnetic sensor.The deficiencies of sensors applied to the monitoring of spinal morphology and motion were analyzed,and the future directions of the application were pointed out.[Chinese Medical Equipment Journal,2025,46(6):105-110]
10.Research progress on mechanism of cGAS-STING pathway mediated cerebral ischemia/reperfusion injury
Meng-ya LI ; Rui LAN ; Xiao-ming SHEN ; Shui-zhi JIAO ; Ya-han LIU ; Bao-qi WANG
Chinese Pharmacological Bulletin 2025;41(3):417-420
Cyclic GMP-AMP synthase(cGAS)is a congenital immune sensor that can recognize cytoplasm abnormal dsDNA.By catalyzing the second messenger cyclic GMP-AMP(cGAMP)formation,it activates stimulator of interferon genes(STING),releases type Ⅰ interferon and inflammatory cytokines,activates the host immune response,and participates in cerebral ischemia reperfusion injury(CIRI)cascade reaction.This article reviews the research progress of the mechanism of cGAS-STING signaling pathway participation in CIRI,hoping to provide ideas for its treatment.

Result Analysis
Print
Save
E-mail