1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Guide on Methodological Standards in Pharmacoepidemiology(2nd edition)and their series interpretation(10):an overview and case study of quality assessment tools
Qingyong ZHENG ; Caihua XU ; Yongjia ZHOU ; Xiao TANG ; Mengjun ZHANG ; Jinzhi QI ; Ming LIU ; Ya GAO ; Feng SUN ; Jinhui TIAN
Chinese Journal of Pharmacoepidemiology 2025;34(10):1113-1126
Methodological quality assessment is a pivotal link between primary studies and reliable evidence-based practice,and an essential pathway for operationalizing the core principles of the Guide on Methodological Standards in Pharmacoepidemiology(2nd edition).A prevalent challenge in practice,however,is the conflation of appraising methodological robustness(risk of bias assessment)with verifying reporting transparency(adherence to reporting guidelines).This paper systematically addresses this fundamental challenge,beginning with a clear distinction between the essence and boundaries of these two concepts.On this basis,the article provides a comprehensive review of mainstream quality assessment tools,covering the methodological features and evolutionary trajectory of numerous instruments for interventional(e.g.,RoB 2,ROBINS-I),observational(e.g.,NOS,the JBI/SIGN/NIH series),secondary(e.g.,AMSTAR 2),and other specific types of studies such as health economic evaluations.Furthermore,a complete case study is used to illustrate the practical application of the ROBINS-I tool.The paper's central thesis advocates for an"appraisal-informed design"philosophy,urging a conceptual shift from the retrospective critique of existing literature to the prospective quality control of new research by internalizing appraisal standards as design principles,while also exploring the emerging paradigm of artificial intelligence in assisting assessment.This paper provides a comprehensive methodological reference for researchers and practitioners to prudently select appropriate assessment tools and to conduct rigorous critical appraisals of pharmacoepidemiological evidence.
3.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]
4.Epidemiological analysis of imported malaria in Yunnan Province,2020-2023
Chun-li DING ; Yao-wu ZHOU ; Zu-rui LIN ; Xiao-dong SUN ; Chun WEI ; Jian-wei XU ; Ya-ming YANG
Chinese Journal of Zoonoses 2025;41(2):193-199
This study analyzed the epidemiological characteristics of imported malaria in Yunnan Province from 2020 to 2023,to provide scientific evidence for formulating measures to decrease imported malaria and prevent re-establishment of malaria transmission.Malaria data reported by the China Disease Prevention and Control Information System were analyzed to determine parasite species;sources of infection;temporal,spatial,and population distributions;and importation routes.A total of 828 malaria cases were reported in the province.Plasmodium vivax and Plasmodium falciparum accounted for 89.98%and 8.33%of cases,respectively.A total of 47.58%of cases were imported from Myanmar,and all P.falciparum malaria ca-ses were from Africa.Thirteen(81.25%)prefectures or municipalities reported malaria,among which Dehong,Baoshan,Kunming,and Lincang reported 94.32%of cases.A total of 52.54%of cases were in young men.The proportion of cross-bor-der personnel flow,land input,and aircraft input were 88.89%and 11.11%respectively.A total of 98.19%of patients sought medical care within 7 days after fever onset,and 82.85%initiated diagnosis for malaria,and 84.90%of diagnoses were con-firmed by health facilities at or below the county level.Imported malaria is a major challenge in preventing re-establishment of transmission in Yunnan.Most imported cases involved cross-border malaria transmission of mainly Plasmodium vivax between China and Myanmar.To achieve malaria elimination,vigilance of health staff in malaria diagnosis and treatment should be pro-moted,and intensive malaria health education should be provided to people traveling to malaria endemic territories,to enable individual protection,and timely diagnosis and treatment after return from endemic countries.
5.Development of Bismuth Iodide Oxide/Nitrogen-doped Graphene Quantum Dots-based Photoelectrochemical Sensor for Determination of Chlorpyrifos
Ya-Fei CHEN ; Xu-Hui ZHANG ; Guang-Wei YANG ; Xiao-Ping WEI ; Jian-Ping LI
Chinese Journal of Analytical Chemistry 2025;53(3):364-374
Bismuth iodide(BiOI)with different crystal plane ratios of(110)to(001)was synthesized,and typeⅡheterojunction formed between(001)and(110)crystal planes of BiOI was used to improve the separation efficiency of photogenerated electrons and holes.Then the BiOI(001)/(110)was composited with nitrogen-doped graphene quantum dots(N-GQDs)to prepare a ternary composites,which could enhance the range and intensity of light absorption,and prolonged the lifetime of photogenerated electrons due to the formation of Z-scheme heterojunctions between BiOI and N-GQDs,thereby leading to the excellent photoelectric performance of the BiOI/N-GQDs for generating sensitive photoelectric response signals.A photoelectrochemical sensor for sensitive detection of chlorpyrifos(CPF)was designed with BiOI/N-GQDs-modified FTO electrode as a photocathode.The S and N atoms contained in CPF were coordinated with Bi(Ⅲ)on the surface of BiOI,which reduced the photocurrent of BiOI/N-GQDs.The photocurrent change was linear with logarithm of concentration of CPF in the range of 1.5×10-12-5.0×10-9 mol/L,and the detection limit was 1.5×10-12 mol/L.The sensor was highly sensitive,selective and stable,and could be used for determination of trace CPF in environmental and food samples.
6.Cross-sectional survey of healthcare-associated infection in 5 736 medical institutions across China in 2024
Cui ZENG ; Wuqiang GAO ; Fu QIAO ; Hui ZHAO ; Xu FANG ; Linping LI ; Xiuwen CHEN ; Jiansen CHEN ; Dan LI ; Yuan ZHOU ; Lingli YU ; Qinglan MENG ; Xia MOU ; Lijuan XIONG ; Weiguang LI ; Ding LIU ; Jiaqing XIAO ; Limei OU ; Baozhen LI ; Jun YIN ; Haojun ZHANG ; Qiang FU ; Qun LU ; Biao WU ; Ya-wei XING ; Shumei SUN ; Shuncai WANG ; Longmin DU ; Jingping ZHANG ; Wen-ying HE ; Gui CHENG ; Nan REN ; Xun HUANG ; Anhua WU
Chinese Journal of Infection Control 2025;24(11):1572-1583
Objective To understand the current situation of healthcare-associated infection(HAI)in China,pro-vide data support and decision-making basis for formulating scientific and effective strategies for HAI prevention and control.Methods A nationwide cross-sectional survey on HAI was conducted among various types and levels of medical institutions in China according to a unified protocol of bedside surveys and case investigations.Results In 2024,a total of 5 736 medical institutions and 2 751 765 patients were surveyed.Among them,34 889 HAI cases were identified,with a prevalence rate of 1.27%.The number of HAI episodes was 38 032,and case prevalence rate was 1.38%.The prevalence rate of HAI in medical institutions in different regions of China ranged from 0.66%to 2.35%.Among medical institutions of different scales,those with a bed capacity of ≥900 had the high-est incidence of HAI,reaching 1.65%.The most common infection site was the lower respiratory tract(44.66%),followed by the urinary tract(12.94%),surgical site(9.32%),upper respiratory tract(7.02%),and bloodstream infection(5.78%).The top 3 departments with the highest HAI rates were the general intensive care unit(10.02%),department of neurosurgery(5.51%),and department(group)of hematology(5.34%).A total of 23 238 strains of HAI pathogens were detected,with 10 714 strains(46.10%)from lower respiratory tract speci-mens.The top 5 detected strains were Klebsiella pneumoniae(14.76%),Pseudomonas aeruginosa(13.33%),Escherichia coli(12.79%),Acinetobacter baumannii(9.23%),and Staphylococcus aureus(7.88%).231 944 pa-tients underwent class Ⅰ incision surgery were monitored,with 1 647 cases experienced surgical site infection,and the prevalence rate of surgical site infection was 0.71%.The number of patients who should undergo pathogen de-tection(patients receiving therapeutic and therapeutic combined prophylactic antimicrobial agents)was 715 179,while the actual number was 480 492,with a pathogen detection rate of 67.18%.425 225 patients received patho-genic detection before treatment,with a detection rate of 59.46%.Conclusion The overall HAI prevalence in Chi-na is lower,showing disparities among medical institutions of different regions and scales.Therefore,precise imple-mentation of measures is necessary for HAI prevention and control,with a focus on high-risk institutions and high-risk departments,key areas,and critical procedures.All levels of medical institutions should continuously reduce the incidence of HAI by strengthening monitoring,standardizing the use of antimicrobial agents,and reinforcing basic HAI prevention and control measures.
7.Efficacy and Safety of Blinatumomab in Adult Patients with B-Cell Acute Lymphoblastic Leukemia
Ya-Lei HU ; Yong-Feng SU ; Yang LI ; Xuan ZHENG ; An WANG ; Yi-Zhi WANG ; Lei XU ; Chun-Ji GAO ; Liang-Ding HU ; Dai-Hong LIU ; Xiao-Ning GAO
Journal of Experimental Hematology 2025;33(6):1571-1576
Objective:To evaluate the efficacy and safety of blinatumomab in adult patients with relapsed/refractory(R/R)or measurable residual disease(MRD)positive B-cell acute lymphoblastic leukemia(B-ALL)in the real world.Methods:The clinical data of 30 B-ALL patients received at least 1 course of blinatumomab therapy in the Chinese PLA General Hospital from January 1st,2021 to December 31st,2023 were retrospectively analyzed,including pre-treatment baseline clinical feature,post-treatment complete response(CR),CR with partial hematologic recovery(CRh),CR with incomplete hematologic recovery(CRi),complete MRD response rate,MRD response rate(MRD<10-4),overall survival(OS),and disease-free survival(DFS),as well as drug-related adverse reactions.Results:Among 5 patients who were not assessed 4 were MRD negative and 1 did not receive bone marrow biopsy.In the R/R B-ALL group(13 cases),11 patients achieved CR/CRh/CRi and 10 patients achieved complete MRD response.In MRD+group(12 cases),9 patients achieved overall MRD response and 7 patients achieved complete MRD response.The median follow-up time was 8.4(95%CI:6.3-10.4)months.The median OS was 15.5(95%CI:0.7-30.3)months in the R/R group,while not reached in the MRD+group.The median DFS of the two groups were not reached.Drug-related adverse reactions occurred in 22 patients,and pyrexia was the most common(13 cases).Grade ≥3 adverse reactions occurred in 15 patients,and neutropenia was the most common(9 cases).Cytokine release syndrome occurred in 6 patients,including 5 cases with grade 1 and 1 case with grade 3.No patients interrupted therapy or died due to drug-related adverse reactions.Conclusion:Blinatumomab is effective in the treatment of R/R or continuous MRD+B-ALL with acceptable adverse reactions.
8.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
9.Isolation,identification,and biological characterization of enterotoxigenic Escherichia coli from a South China tiger
Jing-ru XU ; Zhi-hao ZHU ; Yu-qi LI ; Si-si FAN ; Ya-li KANG ; Yu-bin ZHUO ; Ling-shan HUANG ; Shu-qi QIU ; XUE-YUXI ; Xiao-ping WU ; Yu-ting LIAO ; Wei-ye LIN ; Xiao-ziyi XIAO ; Xue-jin LI ; Teng-teng CHEN ; Xi-pan LIN ; Kai-xiong LIN ; Ke-wei FAN
Chinese Journal of Zoonoses 2025;41(6):567-573
This study was aimed at identifying the pathogenic bacteria responsible for the death of a young tiger at the Fujian Meihua Mountain South China Tiger Breeding Research Institute.Tissue samples from the lungs,liver,and intestines of the deceased tiger were collected,and the bacteria were cultured inasterile environment.The bacterial strains were characterized according to their morphological and molecular biological properties,including assessment of virulence genes and antibiotic resistance genes,mouse lethality tests,and antibiotic susceptibility evaluations.A predominant bacterial strain isolated from the liver of the deceased tiger was identified as enterotoxigenic Escherichia coli(ETEC)strain Tiger22513F.Phylogenetic analysis of the 16S rRNA gene revealed that the Tiger22513F strain exhibited close genetic similarity to the reference strain ETEC(MF919609.1),with 99.9%nucleotide similarity,and resided on the same evolutionary branch.The Tiger22513F strain contained 11 antibiotic resistance genes(tetA,sul1,sul3,cmlA,floR,blaTEM,blaSHV,blaCMY-2,qnrA,qnrS,and qnrD)along with five virulence genes(VT1,fyuA,tsh,iucD,and ST).Mouse lethality tests indicated significant pathogenicity toward mice,affecting primarily the lungs,liver,and intestines.Antibiotic susceptibility testing demonstrated that this strain exhibited resistance to various classes of beta-lactam antibiotics,as well as quinolones and aminoglycosides.This investigation successfully isolated a multi-drug resistant enterotoxigenic Escherichia coli strain with pronounced pathogenicity from the liver of a deceased tiger;thus providing valuable scientific insights for clinical diagnosis,as well as prevention and control measures,against ETEC infections in South China tigers.
10.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.

Result Analysis
Print
Save
E-mail