1.Identification and infection rate of densovirus in Culex pipiens pallens in Beijing in 2023
Xiu-yan XU ; Ting YAN ; Si-jie ZHU ; Jing LI ; Mei-de LIU ; Hong-jiang ZHANG ; Ting LIU ; Qiu-hong LI ; Xiao-jie ZHOU ; Ying TONG ; Yong ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):25-30
Objective This study conducted molecular biological identification of the viruses carried by Culex pipiens pallens specimens collected in Shunyi District, Beijing in 2023, and observed the changes in the infection rate of the viruses carried by Cx. pipiens pallens at different collection times. Methods Cx. pipiens pallens were collected using carbon dioxide mosquito traps. The mosquito samples were ground in batches and analyzed by molecular biology technologies. The virus infection rate at different collection times was analyzed statistically. Results 17 strains of Culex pipiens pallens densovirus(CppDNV)were identified from Cx. pipiens pallens samples collected in Shunyi District, Beijing, in 2023. The nucleotide sequence analysis of the virus genome coding region showed that CppDNV was a single-stranded DNA virus with a total length of 3 335 nt, encoding 2 non-structural proteins(NS1, NS2)and 1 capsid protein(VP). The nucleotide(amino acid)sequence lengths of the three proteins were 2 376 nt(791 aa),1 092 nt(363 aa)and 1 071 nt(356 aa), respectively. Phylogenetic analysis showed that CppDNV was located in genus Brevihamaparvovirus. Statistical analysis showed no significant difference in infection rates across collection times(χ2=4.429, P=0.194). Conclusions CppDNV was identified in Cx. pipiens pallens in Beijing, and it was stably maintained in this natural population.
2.Clinical characteristics combined with inflammatory markers for predicting prognosis of patients with acute ischemic stroke after mechanical thrombectomy
Lingling ZHOU ; Xuchen MENG ; Weijie ZHONG ; Zhaoliang SUN ; Xiaohong SHI ; Tanjun DENG ; Zixian MEI ; Jiexi XIAO ; Dingzhong TANG ; Yi LI
Academic Journal of Naval Medical University 2025;46(10):1290-1296
Objective To explore the potential prognostic factors of patients with acute ischemic stroke(AIS)after undergoing endovascular mechanical thrombectomy and to construct an effective predictive model.Methods A retrospective analysis of clinical data was conducted on 202 patients with anterior circulation large vessel occlusion AIS from 2 stroke centers.All patients received endovascular mechanical thrombectomy treatment,with treatment and follow-up lasting at least 90 d.Basic demographic characteristics,medical records,and baseline blood biomarker data were collected,and the potential prognostic indicators for AIS after 90 d were screened using least absolute shrinkage and selection operator(LASSO)-logistic regression analysis.Results It was found that alcohol drinking(P=0.029),hypertension(P=0.001),diabetes mellitus(P=0.021),stroke or transient ischemic attack(P=0.049),systolic blood pressure on admission(P=0.009),diastolic blood pressure on admission(P=0.038),blood glucose(P=0.003),white blood cell count(P=0.001),neutrophil count(P=0.001),fibrinogen(P=0.010),systemic immune-inflammation index(P=0.008)and neutrophil-to-lymphocyte ratio(NLR)(P<0.001)were associated with adverse clinical outcomes.Nine significant prognostic determinants were screened through LASSO-logistic regression analysis.Multivariate logistic regression analysis revealed that male sex(P=0.008),smoking history(P=0.013),hypertension(P=0.011),lymphocyte(P=0.028),fibrinogen(P=0.016),and NLR(P<0.001)were significant predictive factors for poor prognosis in AIS patients after endovascular thrombectomy treatment.The constructed prognostic model had an accuracy of 76.2%,a sensitivity of 78.2%,a specificity of 71.7%,and a positive predictive value of 86.7%.Conclusion The predictive model established in this study can assist clinicians in identifying high-risk patients with AIS who have undergone endovascular thrombectomy,and it provide guidance for formulating individualized treatment strategies.
3.Bioequivalence of rivaroxabanpian in healthy Chinese subjects
Xu ZHU ; Xiao-ni WANG ; Chang LU ; Ran ZHANG ; Ning CHEN ; Jin-mei ZHOU ; Feng ZHANG ; Wen ZHANG ; Sheng-long ZHAO ; Shun-wang HUANG ; Huan ZHOU
Chinese Pharmacological Bulletin 2025;41(11):2194-2199
Aim To evaluate the bioequivalence of two oral preparations of rivaroxaban tablets(test preparation T and refe-rence preparation R)in fasting/postprandibular state in healthy Chinese subjects.Methods A randomized,open,single-dose,four-cycle,completely repeated crossover experiment was used in this study.A total of 70 healthy male and female subjects were enrolled,including 38 subjects in the fasting group and 32 sub-jects in the postprandial group.Rivaroxaban tablets(2.5 mg/tablet)were taken orally once per cycle and their reference preparations were tested.The plasma rivaroxaban concentration was determined by LC-MS/MS method.The pharmacokinetic parameters of rivaroxaban tablets were calculated by WinNonlin software,and the parameters were analyzed and processed.Re-sults The PK parameters of rivaroxaban tablets and reference preparations in fasting group were as follows:Cmax was(72.48±17.08)and(66.36±15.64)μg·L-1,respectively.AUC0-t were(383.49±101.06)and(370.43±102.16)h·ng·mL-1,and AUC0-inr were(389.58±102.28)and(375.84±103.01)h·μg·L-,respectively.Main PK parameters of subjects taking rivaroxaban tablets orally after meals:Cmax were(66.48±15.64 and 60.87±13.44)μg·L-1,AUC0-t were(404.44±72.58)and(381.80±79.93)h·μg·L-1,re-spectively.AUC0_inf was(410.88±73.55)and(393.64±69.71)h·μg·L-1,respectively.Under fasting and postmeal conditions,subjects took rivaroxaban test and reference prepara-tion orally,one tablet(2.5 mg/tablet)each time.The geometric mean of the main pharmacokinetic parameters of rivaroxaban in plasma(Cmax,AUC0-t,AUC0-inf)and their corresponding values had a 90%confidence interval ranging from 80.00%to 125.00%.No serious adverse events or unexpected adverse e-vents occurred in both groups.Conclusion Rivaroxaban tablets are bioequivalent and safe in vivo under fasting and postprandial conditions.
4.ArcCHECK system-based dose verification methods of ultra-long target for cervical cancer VMAT
Ben-mei ZHOU ; Yong TAN ; Xiao-ying ZHA ; Peng XIAO ; Ming-zong HU
Chinese Medical Equipment Journal 2025;46(11):39-43
Objective To explore the ArcCHECK system-based methods for dose verification of ultra-long target for cervical cancer VMAT so as to assure the precision of cervical cancer radiotherapy.Methods A total of 33 patients with ultra-long target(target length≥26 cm)admitted to some hospital for cervical cancer VMAT from 2021 to 2023 were selected retrospectively,and radiotherapy plans were designed for the patients with VMAT technology and verified dosimetrically with different methods.Firstly,the dose distribution data were collected respectively at 5 and 8 cm away from the center of the ArcCHECK system along the bed exit direction,and enrolled into Group Test 1 and Test 2 respectively.Then the ArcCHECK system was flipped 180°,and the dose distribution data were acquired at 8 cm away from the center along the bed exit direction and included into Group Test 3.Dose merging between Group Test 2 and Test 3 with the Merge function was carried out to obtain the dose distribution data which were divided into Group Test 4.The monitor units of Group Test 1,2 and 4 were summarized,and difference analyses were performed on the length of the target area,detection point and irradiation time.Group Test 1,2 and 4 were compared in terms of γ pass rate,normalized dose deviation,confidence limit(CL)of pass rate and acceptance rate(γ pass rate≥95%and γ pass rate≥90%).Spearman's correlation coefficient was used to correlate the parameters such as maximum transverse diameter,length,volume and monitor unit of the target area and expected execution time of the plan.SPSS 19.0 software was used for statistical analysis.Results Group Test 1,2 and 4 had the monitor unit being(758.76±107.63)MU,and had statistically significant differences in length of the target area,detection point and irradiation time(P<0.01).In Group Test 4 γ pass rate under 2%/2 mm criterion did not reach 90%,and in Group Test 1 and 2 γ pass rates under 3%/3 mm and 3%/2 mm criteria both amounted to 95%.Group Test 1,2 and 4 had statistically significant differences in γ pass rate and normalized dose deviation(all P<0.05).In Group Test 1 there were more than 90%of the verification results where γ pass rate≥95%and more than 95%where γ pass rate≥90%under 3%/3 mm criterion.The monitor unit was positively correlated with the maximum transverse diameter,length and volume of the target area,respectively(0.337≤r≤0.568,P<0.05),and the expected execution time of the plan was positively correlated with the volume and monitor unit of the target area,respectively(0.457≤r≤0.517,P<0.01).Conclusion The dose verification method with the target at 5 cm away from the center along the bed exit direction can be applied clinically with high feasibility to the dose verification during the radiotherapy of the cervical cancer VMAT patients with ultra-long target,with the safety of the verification devices ensured effectively.
5.CNV Encompassing SNP Detection by Cross-reactivity Probe
Xiao-Mei HU ; Chen ZHOU ; Pin-Zheng ZHANG ; Yang CHEN ; Jia-Wen LI ; Yu-Kai MA ; Jia-Qi WANG ; Zhi-Yi GUO
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):895-902
Copy number variation encompassing SNP plays an important role in IVD and precision medi-cine.As the most commonly used method,FISH could not overcome the probe cross-reactivity which is common when to detect SNP.Here we developed a quantitative and qualitative method on copy number variation encompassing SNP.In this study,the rs76711854 was used as an example to establish a quanti-tative method by advantage of probe cross-reactivity.The fragment encompassing rs76711854 and its downstream to 9 514 bp were amplified by PCR.The allelic genotypes were verified by Sanger sequen-cing.Different probes with or without cross-reactivity to be used via quantitative real-time PCR and digit-al PCR.The different clusters(2D)and fluorescence intensity layers(1D)exist by adding probe with cross-reactivity.The A/G ratio measured by digital PCR is 2︰1,which is verified by probe targeting to the SNP.The copy-number variant exists in the 9kb-long fragment upstream to the SNP of prostate cancer cell line but not in human endometrial adenocarcinoma cell line Ishikawa.The data suggest that there is a multi-copy variation at this locus in DU145 cells.The method applied here is based on one single cross-reactivity probe via digital PCR.
6.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
7.Analysis of Lung Cancer Screening Compliance Among High-Risk Population in Chongqing from 2013 to 2021
Lu XIAO ; Shenglin ZHAO ; Zhikai YU ; Jia DU ; Yan ZHANG ; Xiu LIU ; Qing GUO ; Hong ZHOU ; Mei HE
China Cancer 2025;34(3):203-208
[Purpose]To analyze the compliance and its influencing factors of lung cancer screening using low-dose computed tomography(LDCT)among high-risk population in urban districts of Chongqing from 2013 to 2021.[Methods]The lung cancer screeing of Cancer Early Diagnosis and Treatment Project was conducted among permanent residents aged 40~69 years old from 14 urban districts of Chongqing selected by cluster sampling method from 2013 to 2021.The questionnaire survey was performed to assess the risk level of lung cancer,and individuals with high risk were advised to have LDCT examination.The compliance rate of LDCT examination among high-risk populations was calculated and compared using Chi-square test among residents with different de-mographic features;the influencing factors of compliance was analyzed with generalized linear mixed models.[Results]A total of 316 066 residents completed the risk assessment questionnaire survey,52 858 people were assessed as high-risk(17.17%).Among the high-risk population,20 398 completed LDCT screening,with an overall compliance rate of 38.59%.The generalized linear mixed model showed that male participants(OR=0.871,95%CI:0.823~0.922)and smokers(light smokers:OR=0.829,95%CI:0.775~0.886;heavy smokers:OR=0.842,95%CI:0.792~0.896)had lower compliance rates;while people with higher education level(OR=1.347,95%CI:1.265~1.435),occupational exposure to harmful substances(OR=1.400,95%CI:1.340~1.463),passive smoking for 20 years or more(OR=1.472,95%CI:1.376~1.576),infrequent physical exercise(OR=1.203,95%CI:1.152~1.256),family history of lung cancer(OR=2.312,95%CI:2.201~2.429),and those having media promotion by community staff(OR=1.365,95%CI:1.223~1.524),and trained community staff(OR=1.343,95%CI:1.227~1.470)had higher compliance rates.Comorbidities were also factors influencing compliance,and there was an increasing trend of compliance rate with the increase of comorbidity numbers(P<0.001).[Conclusion]The compli-ance rate of LDCT examination for lung cancer screening in Chongqing needs to be improved,and more precise health education should be implemented for groups with different characteristics to improve the compliance among high-risk population.
8.Bioequivalence of rivaroxabanpian in healthy Chinese subjects
Xu ZHU ; Xiao-ni WANG ; Chang LU ; Ran ZHANG ; Ning CHEN ; Jin-mei ZHOU ; Feng ZHANG ; Wen ZHANG ; Sheng-long ZHAO ; Shun-wang HUANG ; Huan ZHOU
Chinese Pharmacological Bulletin 2025;41(11):2194-2199
Aim To evaluate the bioequivalence of two oral preparations of rivaroxaban tablets(test preparation T and refe-rence preparation R)in fasting/postprandibular state in healthy Chinese subjects.Methods A randomized,open,single-dose,four-cycle,completely repeated crossover experiment was used in this study.A total of 70 healthy male and female subjects were enrolled,including 38 subjects in the fasting group and 32 sub-jects in the postprandial group.Rivaroxaban tablets(2.5 mg/tablet)were taken orally once per cycle and their reference preparations were tested.The plasma rivaroxaban concentration was determined by LC-MS/MS method.The pharmacokinetic parameters of rivaroxaban tablets were calculated by WinNonlin software,and the parameters were analyzed and processed.Re-sults The PK parameters of rivaroxaban tablets and reference preparations in fasting group were as follows:Cmax was(72.48±17.08)and(66.36±15.64)μg·L-1,respectively.AUC0-t were(383.49±101.06)and(370.43±102.16)h·ng·mL-1,and AUC0-inr were(389.58±102.28)and(375.84±103.01)h·μg·L-,respectively.Main PK parameters of subjects taking rivaroxaban tablets orally after meals:Cmax were(66.48±15.64 and 60.87±13.44)μg·L-1,AUC0-t were(404.44±72.58)and(381.80±79.93)h·μg·L-1,re-spectively.AUC0_inf was(410.88±73.55)and(393.64±69.71)h·μg·L-1,respectively.Under fasting and postmeal conditions,subjects took rivaroxaban test and reference prepara-tion orally,one tablet(2.5 mg/tablet)each time.The geometric mean of the main pharmacokinetic parameters of rivaroxaban in plasma(Cmax,AUC0-t,AUC0-inf)and their corresponding values had a 90%confidence interval ranging from 80.00%to 125.00%.No serious adverse events or unexpected adverse e-vents occurred in both groups.Conclusion Rivaroxaban tablets are bioequivalent and safe in vivo under fasting and postprandial conditions.
9.ArcCHECK system-based dose verification methods of ultra-long target for cervical cancer VMAT
Ben-mei ZHOU ; Yong TAN ; Xiao-ying ZHA ; Peng XIAO ; Ming-zong HU
Chinese Medical Equipment Journal 2025;46(11):39-43
Objective To explore the ArcCHECK system-based methods for dose verification of ultra-long target for cervical cancer VMAT so as to assure the precision of cervical cancer radiotherapy.Methods A total of 33 patients with ultra-long target(target length≥26 cm)admitted to some hospital for cervical cancer VMAT from 2021 to 2023 were selected retrospectively,and radiotherapy plans were designed for the patients with VMAT technology and verified dosimetrically with different methods.Firstly,the dose distribution data were collected respectively at 5 and 8 cm away from the center of the ArcCHECK system along the bed exit direction,and enrolled into Group Test 1 and Test 2 respectively.Then the ArcCHECK system was flipped 180°,and the dose distribution data were acquired at 8 cm away from the center along the bed exit direction and included into Group Test 3.Dose merging between Group Test 2 and Test 3 with the Merge function was carried out to obtain the dose distribution data which were divided into Group Test 4.The monitor units of Group Test 1,2 and 4 were summarized,and difference analyses were performed on the length of the target area,detection point and irradiation time.Group Test 1,2 and 4 were compared in terms of γ pass rate,normalized dose deviation,confidence limit(CL)of pass rate and acceptance rate(γ pass rate≥95%and γ pass rate≥90%).Spearman's correlation coefficient was used to correlate the parameters such as maximum transverse diameter,length,volume and monitor unit of the target area and expected execution time of the plan.SPSS 19.0 software was used for statistical analysis.Results Group Test 1,2 and 4 had the monitor unit being(758.76±107.63)MU,and had statistically significant differences in length of the target area,detection point and irradiation time(P<0.01).In Group Test 4 γ pass rate under 2%/2 mm criterion did not reach 90%,and in Group Test 1 and 2 γ pass rates under 3%/3 mm and 3%/2 mm criteria both amounted to 95%.Group Test 1,2 and 4 had statistically significant differences in γ pass rate and normalized dose deviation(all P<0.05).In Group Test 1 there were more than 90%of the verification results where γ pass rate≥95%and more than 95%where γ pass rate≥90%under 3%/3 mm criterion.The monitor unit was positively correlated with the maximum transverse diameter,length and volume of the target area,respectively(0.337≤r≤0.568,P<0.05),and the expected execution time of the plan was positively correlated with the volume and monitor unit of the target area,respectively(0.457≤r≤0.517,P<0.01).Conclusion The dose verification method with the target at 5 cm away from the center along the bed exit direction can be applied clinically with high feasibility to the dose verification during the radiotherapy of the cervical cancer VMAT patients with ultra-long target,with the safety of the verification devices ensured effectively.
10.Evaluation of effectiveness of reagent burstbead applied to field blood transfusion compatibility testing
Yi ZHANG ; Xiao-di LIU ; Yi-man ZHAO ; Jing-yan ZHOU ; Shu-mei YANG ; Hao YAN ; Yin-tu MA
Chinese Medical Equipment Journal 2025;46(2):39-42
Objective To explore the reliability of the reagent burstbead for field blood transfusion compatibility testing by applying it to bloodtype detection,antibody screening and cross matching tests and conduting parallel contrast with the existing arrays.Methods A field treatment shelter was used as the testing site to simulate the scene of emergency blood transfusion for the wounded under the conditions of field blood station,and 1 358 pieces of blood samples sent to some hospital for examination before transfusion were considered as the objects.Parallel contrast tests were carried out between the reagent burstbead method and the tube method for bloodtype detection and between the reagent burstbead method and the manual polybrene method for antibody screening and cross matching.The reagent burstbead method was compared with other methods in terms of the coin-cidence rate of the bloodtype detection results,the detection rate of positive samples for antibody screening and crossmatch incompatibility.Results The reagent burstbead method and the tube method had high consistency when used for bloodtype detection,with the coincidence rate being 100%.During antibody screening and cross matching tests,the reagent burstbead method found 5 cases of antibody-positive samples leading to major crossmatch incompatibility(positive rate being 0.37%),the manual polybrene method detected 2 cases of irregular antibody-positive samples(positive rate being 0.15%),and the two methods both identified 3 cases of minor crossmatch incompatibility.Conclusion The reagent burstbead has high accuracy and reliability when applied to bloodtype detection,antibody screening and cross matching tests,and thus can be used for blood transfusion compatibility testing in field conditions.[Chinese Medical Equipment Journal,2025,46(2):39-42]


Result Analysis
Print
Save
E-mail