1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Clinical Advantages of Traditional Chinese Medicine in Treatment of Childhood Simple Obesity: Insights from Expert Consensus
Qi ZHANG ; Yingke LIU ; Xiaoxiao ZHANG ; Guichen NI ; Heyin XIAO ; Junhong WANG ; Liqun WU ; Zhanfeng YAN ; Kundi WANG ; Jiajia CHEN ; Hong ZHENG ; Xinying GAO ; Liya WEI ; Qiang HE ; Qian ZHAO ; Huimin SU ; Zhaolan LIU ; Dafeng LONG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):238-245
Childhood simple obesity has become a significant public health issue in China. Modern medicine primarily relies on lifestyle interventions and often suffers from poor long-term compliance, while pharmacological options are limited and associated with potential adverse effects. Traditional Chinese Medicine (TCM) has a long history in the prevention and management of this condition, demonstrating eight distinct advantages, including systematic theoretical foundation, diversified therapeutic approaches, definite therapeutic efficacy, high safety profile, good patient compliance, comprehensive intervention strategies, emphasis on prevention, and stepwise treatment protocols. Additionally, TCM is characterized by six distinctive features: the use of natural medicinal substances, non-invasive external therapies, integration of medicinal dietetics, simple exercise regimens, precise syndrome differentiation, and diverse dosage forms. By combining internal and external treatments, TCM facilitates individualized regimen adjustment and holistic regulation, demonstrating remarkable effects in improving obesity-related metabolic indicators, regulating constitutional imbalance, and promoting healthy behaviors. However, challenges remain, such as inconsistent operational standards, insufficient high-quality clinical evidence, and a gap between basic research and clinical application. Future efforts should focus on accelerating the standardization of TCM diagnosis and treatment, conducting multicenter randomized controlled trials, and fostering interdisciplinary integration, so as to enhance the scientific validity and international recognition of TCM in the prevention and treatment of childhood obesity.
4.The level of HBV cccDNA in liver tissue and its clinical significance in patients in the convalescence stage of hepatitis B virus-related acute-on-chronic liver failure
Zhekai CAI ; Long XU ; Wenli LIU ; Yingqun XIAO ; Qingmei ZHONG ; Wei ZHANG ; Min WU
Journal of Clinical Hepatology 2025;41(1):57-62
ObjectiveTo investigate the expression level of HBV cccDNA in patients in the convalescence stage of hepatitis B virus-related acute-on-chronic liver failure (HBV-ACLF) and its correlation with HBV markers and liver histopathological changes. MethodsA total of 30 patients in the convalescence stage of HBV-ACL who were hospitalized in The Ninth Hospital of Nanchang from January 2015 to October 2023 were enrolled as liver failure group, and 9 patients with chronic hepatitis B (CHB), matched for sex and age, were enrolled as control group. The content of HBV cccDNA in liver tissue was measured, and its correlation with clinical data and laboratory markers was analyzed. The independent-samples t test or the Mann-Whitney U test was used for comparison of continuous data between two groups, and a one-way analysis of variance or the Kruskal-Wallis H test was used for comparison between multiple groups; the Fisher’s exact test was used for comparison of categorical data between groups. A Spearman correlation analysis was performed. ResultsThe liver failure group had a significantly lower content of HBV cccDNA in liver tissue than the control group (-0.92±0.70 log10 copies/cell vs -0.13±0.91 log10 copies/cell, t=2.761, P=0.009). In the liver failure group, there was no significant difference in the content of HBV cccDNA in liver tissue between the HBeAg-positive patients and the HBeAg-negative patients (P>0.05); there was no significant difference in the content of HBV cccDNA in liver tissue between the patients with different grades (G0-G2, G3, and G4) of liver inflammatory activity (P>0.05); there was no significant difference in the content of HBV cccDNA in liver tissue between the patients with different stages (S0-S2, S3, and S4) of liver fibrosis (P>0.05); there was no significant difference in the content of HBV cccDNA in liver tissue between the patients with negative HBV DNA and those with positive HBV DNA (P>0.05). For the liver failure group, the content of HBV cccDNA in liver tissue was positively correlated with the content of HBV DNA in liver tissue (r=0.426, P=0.043) and was not significantly correlated with the content of HBV DNA in serum (P>0.05). ConclusionThere is a significant reduction in the content of HBV cccDNA in liver tissue in the convalescence stage of HBV-ACLF. HBV cccDNA exists continuously and stably in liver tissue and can better reflect the persistent infection and replication of HBV than HBV DNA in serum and liver tissue.
5.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
6.Mechanism of emodin improving cardiac hypertrophy in mice based on p38/ERK pathway
Jia SHI ; Sai-Ge SUN ; Yi-Lin HE ; Li XU ; Long-Xing LIU ; Zi-Jie GE ; Xiao-Yi ZOU ; Yu MA ; Yao-Cheng DING ; Kai QIAN
Chinese Pharmacological Bulletin 2025;41(7):1245-1252
Aim Mouse model of myocardial hypertro-phy was established via intraperitoneal injection of iso-proterenol(ISO)in mice.This approach allows for an in-depth investigation into the pharmacological effects and mechanisms of action of emodin,offering novel in-sights and directions for the improvement of myocardial hypertrophy.Methods The mice were randomly di-vided into the following groups:control group(CON),emodin group(EMO),MAPK activator control group(EMO+Ani),model group(ISO),treatment group(ISO+EMO),and activator intervention group(ISO+EMO+Ani).After treatment with emodin and inter-vention with MAPK activator,the heart weight ratio and cardiac size of each group were observed.Hematoxy-lin-eosin(HE)staining was used to observe the patho-logical changes in cardiac tissue,and kits were utilized to measure the levels of GSH,LDH,and MDA in the serum.Western blot was employed to detect the protein expression levels of inflammatory and oxidative factors,as well as p-p38,p-ERK,p38,and ERK in cardiac tis-sue.Results Emodin can significantly inhibit the production of myocardial inflammatory and oxidative factors induced by ISO,thereby effectively alleviating the degree of myocardial hypertrophy and fibrosis.Af-ter the p38/ERK signaling pathway was specifically ac-tivated by farnesol,the improvement effect of emodin on myocardial hypertrophy was weakened.Further comparison revealed that,compared with the myocardi-al hypertrophy pathological model group,the pathologi-cal protein expression levels in the farnesol-treated group showed no significant difference,and were even higher in some indicators.Conclusion Emodin can effectively inhibit the release of inflammatory factors and improve the state of oxidative stress by modulating the p38/ERK signaling pathway,thereby exerting an ameliorative effect on myocardial hypertrophy.
7.Efficacy and safety of high-power,short-duration radiofrequency catheter ablation for persistent atrial fibrillation
Guang-an LIU ; Wang-long WU ; Lin-xiao ZHOU ; Jing CUI ; Bo SHAO ; Ruo-xi ZHANG ; Feng LIU
Chinese Journal of Interventional Cardiology 2025;33(5):266-271
Objective To evaluate the efficacy and safety of high-power,short-duration radiofrequency catheter ablation for the treatment of persistent atrial fibrillation.Methods This retrospective study included 392 patients diagnosed with persistent atrial fibrillation who underwent catheter radiofrequency ablation at Suzhou Kowloon Hospital,Shanghai Jiao Tong University School of Medicine,from January 2019 to December 2023.Of these,256 patients were treated with high-power,short-duration ablation,and 136 patients with low-power,long-duration ablation.The following parameters were compared:radiofrequency ablation time,total procedure time,single-circle pulmonary vein isolation rate,immediate procedural success rate,number of ablation points,and perioperative complications(including pericardial tamponade,pseudoaneurysm,arteriovenous fistula,stroke,etc.).Follow-up assessments were conducted at 3,6,and 12 months post-surgery to evaluate the 12-month sinus rhythm maintenance rate.Results The ablation time in the high-power group was significantly shorter than that in the low-power group[(14.6±2.3)min vs.(30.3±4.2)min,P<0.001],as was the total procedure time[(113.8±24.8)min vs.(128.5±26.7)min,P=0.001].There were no significant differences between the two groups in terms of pulmonary vein isolation rate(97.7%vs.94.9%,P=0.823),number of ablation points[(71.2±8.0)vs.(74.3±14.3),P=0.168],or perioperative complications(3.1%vs.4.4%,P=0.571).Regarding the maintenance rate of sinus rhythm at 12 months post-operation,the high-power group showed a higher rate than the low-power group,but no statistically significant difference was observed(82.8%vs.79.4%,P=0.399).Conclusions High-power,short-duration radiofrequency catheter ablation can improve procedural efficiency in the treatment of persistent atrial fibrillation.Its efficacy and safety are similar to those of the low-power,long-duration technique.
8.Fluorescence Method for Determination of Metolazone and Valsartan in Human Serum and Urine:A Comparison from Zero-order to Second-order Calibration Method
Zi-Wei DING ; Hai-Long WU ; Xiao-Zhi WANG ; Tong WANG ; Hao-Ran LIU
Chinese Journal of Analytical Chemistry 2025;53(2):224-234
A second-order calibration method combined with excitation-emission matrix(EEM)fluorescence spectroscopy was presented for simultaneous quantitative analysis of two anti-hypertensive drugs,metolazone(MET)and valsartan(VAL),in human serum and urine,and the quantitative results were compared with the results obtained by zero-and first-order calibration methods.The results indicated that the methods based on zero-and first-order calibration were inadequate for accurately quantifying the components of interest in cases where severe spectral overlap and unknown interferences coexisted.However,it was possible to obtain satisfactory results with the second-order calibration method based on alternating normalization-weighted error(ANWE)algorithm because of its strong"mathematical separation",even when the fluorescence spectra of the target analytes and unknown interferents considerably overlapped.Correlation coefficients for both analytes were greater than 0.99,with mean recoveries of 104.9%±5.7%and 107.8%±9.2%for MET and VAL in human serum,and 103.7%±8.9%and 94.7%±3.8%in human urine,respectively.In addition,the sensitivity,selectivity,limit of detection,limit of quantification,repeatability,and reproducibility of the proposed second-order calibration method were thoroughly examined.All results indicated that the established method was capable of achieving simultaneous and accurate quantification of MET and VAL in human body fluids,which was expected to be applied to analysis of both drugs in clinical settings.
9.Research on In-Situ Extractive Ionization for Original Ecological Samples and Its Miniature Device
Xiao-Feng DONG ; Feng LIU ; You-Han XUE ; Xi-De YE ; Shuang-Long WANG
Chinese Journal of Analytical Chemistry 2025;53(5):749-757
Current ambient mass spectrometry ionization often requires external auxiliary equipment such as high-voltage power supply,gas cylinder,and syringe pump.Moreover,the process of sample preparation is cumbersome,and the experimental operations are complex,which makes it difficult to adapt to real-time on-site detection.In this work,a novel method was proposed,in which direct sampling of raw samples,online extraction of interest analytes,and ionization of target molecules were integrated into a single unit.With the developed method,the in-situ extraction and nano-electrospray ionization for both liquid and solid raw samples were achieved.Also,a handheld ion source and its pose adjustment device were developed,and the position and angle parameters were subsequently optimized.The performance of the ionization device was tested using standard solutions of caffeine and reserpine.The limits of detection(LODs)were 0.08 μg/L and 0.14 μg/L,with relative standard deviations(RSDs)≤3.7% and≤5.6%,respectively,indicating that the device possessed high sensitivity and stability.Using this device,three different concentrations of reserpine standard solutions were continuously tested for five days.The intra-day RSDs were consistently≤4.7% and the inter-day RSDs were all≤10.3%,showing the good working stability of the device.Without any pretreatment,a rapid qualitative detection of medicinal components including astragaloside II and cycloastragenol in five traditional Chinese medicines was carried out,with RSDs≤8.0% and≤7.1%,respectively.Additionally,rapid qualitative detection of gallic acid,a medicinal component,in white peony roots,and hypaphorine as well as quercetin in cowherb seeds were carried out,with RSDs≤7.0%,≤6.4% and≤6.1%,respectively.These results demonstrated that the ionization technology and device exhibited good stability during qualitative detection of raw samples.
10.Competitive Immunoassay for Detection of Enrofloxacin Based on Metasurface Plasma Resonance Chip Coupled with Gold Nanoparticles
Wei-Hao JI ; Hong-Li FAN ; Lei GONG ; Li-Ping HUANG ; Xiao-Long FAN ; Jia-Yong HU ; Tao-Hong ZHOU ; Gang LIU
Chinese Journal of Analytical Chemistry 2025;53(5):814-822
Risks of food safety induced by small molecule drug residues in animal food and environment have become an increasing public concern,so it is necessary to develop highly sensitive and easy-to-operate techniques to detect small molecules.Herein,a metasurface plasma resonance(MetaSPR)sensor chip coupled with gold nanoparticles(AuNPs)was developed for detection of enrofloxacin(ENR)based on competitive immunoassay.The detection range of the sensor for ENR was 0.025-3.2 ng/mL,and the detection limit(3σ)was 20 pg/mL.The biosensor showed excellent performance including high selectivity,good stability,ease to operate and high throughput,etc.The developed method was applied to detection of ENR residues in real samples,with recoveies of 96.0% -105.0%.The proposed sensing strategy provided new technique reference for detection of other small molecules in the field of residue analysis in food safety and environment monitoring.

Result Analysis
Print
Save
E-mail