1.Applications of Vaterite in Drug Loading and Controlled Release
Xiao-Hui SONG ; Ming-Yu PAN ; Jian-Feng XU ; Zheng-Yu HUANG ; Qing PAN ; Qing-Ning LI
Progress in Biochemistry and Biophysics 2025;52(1):162-181
Currently, the drug delivery system (DDS) based on nanomaterials has become a hot interdisciplinary research topic. One of the core issues is drug loading and controlled release, in which the key lever is carriers. Vaterite, as an inorganic porous nano-material, is one metastable structure of calcium carbonate, full of micro or nano porous. Recently, vaterite has attracted more and more attention, due to its significant advantages, such as rich resources, easy preparations, low cost, simple loading procedures, good biocompatibility and many other good points. Vaterite, gained from suitable preparation strategies, can not only possess the good drug carrying performance, like high loading capacity and stable loading efficiency, but also improve the drug release ability, showing the better drug delivery effects, such as targeting release, pH sensitive release, photothermal controlled release, magnetic assistant release, optothermal controlled release. At the same time, the vaterite carriers, with good safety itself, can protect proteins, enzymes, or other drugs from degradation or inactivation, help imaging or visualization with loading fluorescent drugs in vitro and in vivo, and play synergistic effects with other therapy approaches, like photodynamic therapy, sonodynamic therapy, and thermochemotherapy. Latterly, some renewed reports in drug loading and controlled release have led to their widespread applications in diverse fields, from cell level to clinical studies. This review introduces the basic characteristics of vaterite and briefly summarizes its research history, followed by synthesis strategies. We subsequently highlight recent developments in drug loading and controlled release, with an emphasis on the advantages, quantity capacity, and comparations. Furthermore, new opportunities for using vaterite in cell level and animal level are detailed. Finally, the possible problems and development trends are discussed.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.MAUP Effect on Spatial Pattern of Pseudostellaria heterophylla Production Regions in China
Leting ZHANG ; Tao ZHOU ; Chengdong XU ; Zhixian JING ; Chenghong XIAO ; Hui WANG ; Tingting SHI ; Jiawei HUANG ; Xiaobo ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(22):183-191
ObjectiveTo investigate the modifiable areal unit problem (MAUP) in the spatial pattern of Pseudostellaria heterophylla production regions and reveal the impact of statistical scales on the spatial distribution characteristics of this medicinal plant species. MethodsUsing multi-source data (literature records, field surveys, and statistical data), we systematically analyzed the spatial patterns across three administrative levels (provincial, prefectural, and county scales). Spatial autocorrelation (Moran's I) analysis, high-low clustering (Getis-Ord General G), and hot/cold spot analysis (Getis-Ord Gi*) were employed. ResultsThe literature-based analysis showed that the production regions of P. heterophylla presented random distribution on the provincial scale and significant aggregation on the prefectural scale. The field survey data showed that the production regions displayed random distribution on the provincial scale but significant aggregation on both prefectural and county scales. The statistical data revealed that the production regions lacked spatial autocorrelation on the provincial scale but demonstrated significant aggregation on prefectural and county scales. ConclusionMAUP effects have substantive implications for understanding and decision-making in the arrangement of medicinal plant production regions. The county scale proves to be the most sensitive and explanatory level for analyzing the spatial pattern of P. heterophylla production regions, providing a critical foundation for habitat modeling, suitability evaluation, and ecological cultivation planning of medicinal plants.
8.Effects of Anchusa italica Retz.on cough variant asthma and the level of TLR4/NF-κB signaling pathway
Liang CHEN ; Xiao-Qin XU ; Wen-Hui GUO ; HAJIAKBER·Aisa ; Di-Na MAI
The Chinese Journal of Clinical Pharmacology 2024;40(5):698-702
Objective To investigate the effect of Anchusa italica Retz.extract on cough variant asthma(CVA)and its mechanism of action.Methods Forty-eight SD rats of each eight were randomly divided into blank group(equal amount of saline),model group(equal amount of saline),control group(250 mg·kg-1 prednisone acetate)and experimental-A1,-A5,-A7 groups(61.1 mg·kg-1 Anchusa italica Retz.extract A1,48.8 mg·kg-1 Anchusa italica Retz.extract A5,201.8 mg·kg-1 Anchusa italica Retz.extract A7),continuous gavage for 28 d;except for the blank group,the other groups were made with ovalbumin-complete Freund's adjuvant.The number of cough times of each rat was observed.The changes in the expression of Toll-like receptor 4(TLR4),myeloid differentiation factor(MyD88)and nuclear factor κB(NF-κB)proteins were observed in the lung tissue.Results The cough times in the blank group,model group,control group and experimental-A1,-A5,-A7 groups were 1.10±0.22,8.33±1.24,3.08±0.65,3.31±0.99,3.08±1.02 and 3.06±0.68;the relative expression levels of TLR4 protein were 0.61±0.01,0.84±0.04,0.66±0.02,0.64±0.04,0.64±0.03 and 0.69±0.02;the relative expression levels of MyD88 protein were 0.54±0.08,0.86±0.06,0.71±0.06,0.65±0.05,0.64±0.08 and 0.70±0.06;the relative expression levels of p-NF-κB protein were 0.48±0.11,0.94±0.06,0.80±0.08,0.68±0.04,0.68±0.06 and 0.78±0.09.Compared with the experimental-A1,-A5,-A7 groups,control group,normal group,the differences were statistically significant in the model group(all P<0.05).Conclusion The extract of Anchusa Italica Retz.can inhibit the symptoms of CVA rats,and the mechanism may be related to the inhibition of TLR4/MyD88/NF-κB signaling pathway.
9.Bioequivalence study of etoricoxib tablets in healthy Chinese subjects
Zhen-Zhen JIAO ; Li XU ; Man LIU ; Tian-Ze HU ; Dan SONG ; Xiao-Juan WANG ; Zhi-Jing ZHAO ; Hui-Chen LIU
The Chinese Journal of Clinical Pharmacology 2024;40(5):718-722
Objective To study the pharmacokinetic characteristics of etoricoxib tablets in healthy Chinese subjects and to evaluate the bioequivalence and safety of the test and reference formulations.Methods In a randomised,single-dose,two-period,two-sequence crossover trial,28 healthy subjects were enrolled under the fasting and fed conditions,respectively,who received a single oral dose of 60 mg of etoricoxib tablets in the test or reference formulation.The concentration of etoricoxib in plasma was detected by LC-MS/MS,and the main pharmacokinetic parameters were calculated to evaluate bioequivalence and using WinNonlin 8.2 software.Results The main pharmacokinetic parameters of the test and reference preparations were as follows:The fasting condition Cmax of etoricoxib were(1 176.96±287.95)and(1 164.93±189.65)ng·mL-1;AUC0-t were(18 651.95±6 100.27)and(19 241.39±6 107.48)ng·h·mL-1;and AUC0-∞ were(19 939.15±7 553.27)and(20 536.31±7 223.40)ng·h·mL-1.The fed condition Cmax of etoricoxib were(913.50±184.72)and(878.59±164.35)ng·mL-1;and AUC0-t were(19 085.22±5 155.01)and(18 669.54±4 508.21)ng·h·mL-1;AUC0-∞ were(20 103.77±5 567.02)and(19 528.05±4 989.74)ng·h·mL-1.The 90%confidence intervals for the geometric mean ratios of the main pharmacokinetic parameters in the fasting and fed conditions fell between 80.00%and 125.00%.The incidence of adverse events in the fasting and fed conditions were 28.57%and 21.43%,respectively.Conclusion Two kinds of etoricoxib tablets are bioequivalent,and have similar safety in healthy Chinese subjects.
10.Clinical trial of rituximab and leflunomide in the treatment of patients with systemic lupus erythematosus
Jia-Hui GUO ; Jun-Jie ZOU ; Yang-Yang WANG ; Jin-Long ZHANG ; Dan-Dan PANG ; Xiao-Yan XU
The Chinese Journal of Clinical Pharmacology 2024;40(11):1547-1550
Objective To observe the clinical efficacy and safety of rituximab injection combined with leflunomide tablets in the treatment of patients with systemic lupus erythematosus(SLE).Methods The SLE patients were divided into control and treatment groups according to cohort method.The control group received leflunomide with 50 mg·d-1 after meal in the first 3 days of treatment and was adjusted to 20 mg·d-1 thereafter.On the basis of control group,the treatment group was combined with rituximab,375 mg·m-2 was given intravenously every 2 weeks in the first 3 times of treatment,and adjusted to once every 4 weeks from the 4th dose.Two groups were treated for 24 weeks.The clinical efficacy,systemic lupus erythematosus disease activity index(SLEDAI)scores,serological indicators,24-hour urinary protein and adverse drug reactions were compared between two groups.Results The treatment and control groups were enrolled 74 cases and 72 cases,respectively.After treatment,the total effective rates of treatment and control groups were 91.89%(68 cases/74 cases)and 79.17%(57 cases/72 cases)with significant difference(P<0.05).After treatment,the SLEDAI scores of treatment and control groups were(7.21±1.67)and(9.03±1.35)points;the levels of anti-Smith/ribonucleoprotein antibodies were(81.43±18.25)and(59.38±14.61)U·mL-1;the levels of immunoglobulin G were(12.04±2.15)and(17.28±2.64)g·L-1;the levels of interleukin-10 were(33.39±7.13)and(39.87±9.02)pg·mL-1;24-hour urinary protein quantification were(1.46±0.32)and(2.67±0.54)g·24 h-1;all the differences were statistically significant(all P<0.05).The drug adverse reactions of two groups were liver and kidney function injury and digestive tract reactions.The total incidences of drug adverse reactions in the treatment and control groups were 13.51%and 5.56%without significant difference(P>0.05).Conclusion Rituximab injection combined with leflunomide tablets has a definitive clinical efficacy in the treatment of SLE patients,which can significantly reduce disease activity and inflammatory reactions,improve immune function,without increasing the incidence of drug adverse reactions.

Result Analysis
Print
Save
E-mail