1.Clinical study on the immediate and short-term therapeutic effects of Shexiang Tongxin Dripping Pill on improving coronary slow flow
Yong LIU ; Hui HU ; Yuncui WANG ; Di XIAO ; Jingfan KANG ; Lijing ZHANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(5):605-612
Objective To explore the immediate and short-term effects of Shexiang Tongxin Dripping Pill in the intervention of coronary slow flow(CSF).Methods Through Interactive Web Response System,Sixty-four patients with CSF from Dongzhimen Hospital,Beijing University of Chinese Medicine were divided into a Shexiang Tongxin Dripping Pill group(32 patients)and a placebo group(32 patients)in a 1∶1 ratio in a randomized,double-blind,placebo-controlled trial.After sublingual administration of four capsules of Shexiang Tongxin Dripping Pill or the placebo,coronary angiography was repeated,and the corrected TIMI frame count(CTFC)and microcirculatory resistance index(caIMR)were measured to evaluate immediate blood flow velocity.After taking Shexiang Tongxin Dripping Pill or the placebo for 12 weeks,the short-term efficacy was evaluated using traditional Chinese medicine(TCM)syndrome,blood stasis syndrome,and Seattle Angina Questionnaire(SAQ)scores.Results The CTFC and caIMR were lower after administration in the Shexiang Tongxin Dripping Pill group(P<0.05)than in the placebo group,and the differences in pre-and post-administration values between the two groups were significant(P<0.01).Intragroup comparisons showed that the CTFC and caIMR in the Shexiang Tongxin Dripping Pill group were lower after administration than before administration(P<0.01).After 12 weeks of treatment,the blood stasis and TCM syndrome scores in the Shexiang Tongxin Dripping Pill group were lower than those in the placebo group,whereas the SAQ score was higher than that in the placebo group(P<0.01).Intragroup comparisons indicated that the blood stasis syndrome score in the Shexiang Tongxin Dripping Pill group was lower after treatment than before treatment,whereas the TCM syndrome score in both groups was lower and the SAQ score was higher after treatment than before treatment(P<0.01).Conclusion Shexiang Tongxin Dripping Pill improve the immediate blood flow velocity of CSF,enhance the quality of life of patients,reduce the TCM syndrome and blood stasis syndrome scores,and have good safety.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Endoplasmic reticulum membrane remodeling by targeting reticulon-4 induces pyroptosis to facilitate antitumor immune.
Mei-Mei ZHAO ; Ting-Ting REN ; Jing-Kang WANG ; Lu YAO ; Ting-Ting LIU ; Ji-Chao ZHANG ; Yang LIU ; Lan YUAN ; Dan LIU ; Jiu-Hui XU ; Peng-Fei TU ; Xiao-Dong TANG ; Ke-Wu ZENG
Protein & Cell 2025;16(2):121-135
Pyroptosis is an identified programmed cell death that has been highly linked to endoplasmic reticulum (ER) dynamics. However, the crucial proteins for modulating dynamic ER membrane curvature change that trigger pyroptosis are currently not well understood. In this study, a biotin-labeled chemical probe of potent pyroptosis inducer α-mangostin (α-MG) was synthesized. Through protein microarray analysis, reticulon-4 (RTN4/Nogo), a crucial regulator of ER membrane curvature, was identified as a target of α-MG. We observed that chemically induced proteasome degradation of RTN4 by α-MG through recruiting E3 ligase UBR5 significantly enhances the pyroptosis phenotype in cancer cells. Interestingly, the downregulation of RTN4 expression significantly facilitated a dynamic remodeling of ER membrane curvature through a transition from tubules to sheets, consequently leading to rapid fusion of the ER with the cell plasma membrane. In particular, the ER-to-plasma membrane fusion process is supported by the observed translocation of several crucial ER markers to the "bubble" structures of pyroptotic cells. Furthermore, α-MG-induced RTN4 knockdown leads to pyruvate kinase M2 (PKM2)-dependent conventional caspase-3/gasdermin E (GSDME) cleavages for pyroptosis progression. In vivo, we observed that chemical or genetic RTN4 knockdown significantly inhibited cancer cells growth, which further exhibited an antitumor immune response with anti-programmed death-1 (anti-PD-1). In translational research, RTN4 high expression was closely correlated with the tumor metastasis and death of patients. Taken together, RTN4 plays a fundamental role in inducing pyroptosis through the modulation of ER membrane curvature remodeling, thus representing a prospective druggable target for anticancer immunotherapy.
Pyroptosis/immunology*
;
Humans
;
Endoplasmic Reticulum/immunology*
;
Animals
;
Nogo Proteins/antagonists & inhibitors*
;
Mice
;
Cell Line, Tumor
;
Xanthones/pharmacology*
;
Neoplasms/pathology*
;
Mice, Nude
7.Predicting Postoperative Circulatory Complications in Older Patients: A Machine Learning Approach.
Xiao Yun HU ; Wei Xuan SHENG ; Kang YU ; Jie Tai DUO ; Peng Fei LIU ; Ya Wei LI ; Dong Xin WANG ; Hui Hui MIAO
Biomedical and Environmental Sciences 2025;38(3):328-340
OBJECTIVE:
This study examines utilizes the advantages of machine learning algorithms to discern key determinants in prognosticate postoperative circulatory complications (PCCs) for older patients.
METHODS:
This secondary analysis of data from a randomized controlled trial involved 1,720 elderly participants in five tertiary hospitals in Beijing, China. Participants aged 60-90 years undergoing major non-cardiac surgery under general anesthesia. The primary outcome metric of the study was the occurrence of PCCs, according to the European Society of Cardiology and the European Society of Anaesthesiology diagnostic criteria. The analysis metrics contained 67 candidate variables, including baseline characteristics, laboratory tests, and scale assessments.
RESULTS:
Our feature selection process identified key variables that significantly impact patient outcomes, including the duration of ICU stay, surgery, and anesthesia; APACHE-II score; intraoperative average heart rate and blood loss; cumulative opioid use during surgery; patient age; VAS-Move-Median score on the 1st to 3rd day; Charlson comorbidity score; volumes of intraoperative plasma, crystalloid, and colloid fluids; cumulative red blood cell transfusion during surgery; and endotracheal intubation duration. Notably, our Random Forest model demonstrated exceptional performance with an accuracy of 0.9872.
CONCLUSION
We have developed and validated an algorithm for predicting PCCs in elderly patients by identifying key risk factors.
Aged
;
Aged, 80 and over
;
Female
;
Humans
;
Male
;
Middle Aged
;
Cardiovascular Diseases/etiology*
;
Machine Learning
;
Postoperative Complications/etiology*
;
Risk Factors
;
Randomized Controlled Trials as Topic
;
Secondary Data Analysis
8.National bloodstream infection bacterial resistance surveillance report 2023: Gram-positive bacteria
Chaoqun YING ; Jinru JI ; Zhiying LIU ; Qing YANG ; Haishen KONG ; Jiangqin SONG ; Hui DING ; Yanyan LI ; Yuanyuan DAI ; Haifeng MAO ; Pengpeng TIAN ; Lu WANG ; Yongyun LIU ; Yizheng ZHOU ; Jiliang WANG ; Yan JIN ; Donghong HUANG ; Hongyun XU ; Peng ZHANG ; Xinhua QIANG ; Hong HE ; Lin ZHENG ; Junmin CAO ; Zhou LIU ; Ying HUANG ; Yan GENG ; Haiquan KANG ; Dan LIU ; Guolin LIAO ; Lixia ZHANG ; Fenghong CHEN ; Yanhong LI ; Baohua ZHANG ; Haixin DONG ; Xiaoyan LI ; Donghua LIU ; Qiuying ZHANG ; Xuefei HU ; Liang GUO ; Sijin MAN ; Dijing SONG ; Rong XU ; Youdong YIN ; Kunpeng LIANG ; Aiyun LI ; Zhuo LI ; Hongxia HU ; Guoping LU ; Jinhua LIANG ; Qiang LIU ; Yinqiao DONG ; Jilu SHEN ; Shuyan HU ; Liang LUAN ; Jian LI ; Ling MENG ; Dengyan QIAO ; Xiusan XIA ; Bo QUAN ; Dahong WANG ; Chunhua HAN ; Xiaoping YAN ; Fei LI ; Shifu WANG ; Ping SHEN ; Yunbo CHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2025;18(2):118-132
Objective:To report the nationwide surveillance results of pathogenic profiles and antimicrobial resistance patterns of Gram-positive bloodstream infections in China in 2023.Methods:The clinical isolates of Gram-posttive bacteria from blood cultures were collected in member hospitals of National Bloodstream Infection Bacterial Resistant Investigation Collaborative System(BRICS)during January to December 2023. Antimicrobial susceptibility testing was performed using the dilution method recommended by the Clinical and Laboratory Standards Institute(CLSI). Statistical analyses were conducted using WHONET 5.6 and SPSS 25.0 software.Results:A total of 4 385 Gram-positive bacterial isolates were obtained from 60 participating center. The top five pathogens were Staphylococcus aureus( n=1 544,35.2%),coagulase-negative Staphylococci( n=1 441,32.9%), Enterococcus faecium( n=574,13.1%), Enterococcus faecalis( n=385,8.8%),and α-hemolytic Streptococci( n=187,4.3%). The prevalence of methicillin-resistant Staphylococcus aureus(MRSA)and methicillin-resistant coagulase-negative Staphylococci(MRCNS)was 26.2%(405/1 544)and 69.8%(1 006/1 441),respectively. Notably,all Staphylococci remained susceptible to glycopeptide or daptomycin. Staphylococcus aureus demonstrated excellent susceptibility(>97.0%)to cephalobiol,rifampicin,trimethoprim-sulfamethoxazole,linezolid,minocycline,tigecycline,and eravacycline. No Enterococcus exhibiting resistance to linezolid were detected. Glycopeptide resistance was uncommon but more frequent in Enterococcus faecium(resistance to vancomycin and teicoplanin:both 1.7%)compared to Enterococcus faecalis(both 0.3%). The detection rates of MRSA and MRCNS exhibited significant regional variations across the country( χ2=17.674 and 148.650,respectively,both P<0.001). No vancomycin-resistant Enterococci were detected in central China. Institutional comparison demonstrated higher prevalence of MRSA( χ2=14.111, P<0.001)and MRCNS( χ2=4.828, P=0.028)in provincial hospitals than that in municipal hospitals. Socioeconomic analysis identified elevated detection rates of both MRSA( χ2=18.986, P<0.001)and MRCNS( χ2=4.477, P=0.034)in less developed regions(per capita GDP
9.National bloodstream infection bacterial resistance surveillance report (2023) : Gram-negative bacteria
Jinru JI ; Zhiying LIU ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Jiangqin SONG ; Hui DING ; Yanyan LI ; Yuanyuan DAI ; Haifeng MAO ; Pengpeng TIAN ; Lu WANG ; Yongyun LIU ; Yizheng ZHOU ; Jiliang WANG ; Yan JIN ; Donghong HUANG ; Hongyun XU ; Peng ZHANG ; Xinhua QIANG ; Hong HE ; Lin ZHENG ; Junmin CAO ; Zhou LIU ; Ying HUANG ; Yan GENG ; Haiquan KANG ; Dan LIU ; Guolin LIAO ; Lixia ZHANG ; Fenghong CHEN ; Yanhong LI ; Baohua ZHANG ; Haixin DONG ; Xiaoyan LI ; Donghua LIU ; Qiuying ZHANG ; Xuefei HU ; Liang GUO ; Sijin MAN ; Dijing SONG ; Rong XU ; Youdong YIN ; Kunpeng LIANG ; Aiyun LI ; Zhuo LI ; Hongxia HU ; Guoping LU ; Jinhua LIANG ; Qiang LIU ; Yinqiao DONG ; Jilu SHEN ; Shuyan HU ; Liang LUAN ; Jian LI ; Ling MENG ; Dengyan QIAO ; Xiusan XIA ; Bo QUAN ; Dahong WANG ; Chunhua HAN ; Xiaoping YAN ; Fei LI ; Shifu WANG ; Ping SHEN ; Yunbo CHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2025;18(1):47-62
Objective:To report the results of bacterial resistant investigation collaborative system(BRICS)on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2023,and provide reference for clinical tretment of bloodstream infections and prevention and control of bacterial resistance.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of BRICS were collected during January 2023 to December 2023. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 were used to analyze the data.Results:During the study period,11 492 strains of Gram-negative bacteria were collected from 60 hospitals,of which 10 098(87.9%)were Enterobacterales and 1 394(12.1%)were non-fermentative bacteria. The top 5 bacterial species were Escherichia coli(50.0%), Klebsiella pneumoniae(26.1%), Pseudomonas aeruginosa(5.1%), Acinetobacter baumannii complex(5.0%)and Enterobacter cloacae complex(4.1%). The ESBL-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus mirablilis were 46.8%(2 685/5 741),18.3%(549/2 999)and 44.0%(77/175),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(76/5 741)and 15.0%(450/2 999);32.9%(25/76)and 78.0%(351/450)of CREC and CRKP were sensitive to ceftazidime/avibactam combination,respectively. 94.7%(72/76)and 90.2%(406/450)of CREC and CRKP were sensitive to aztreonam/avibactam combination. Furthermore,57.9%(44/76)and 79.1%(356/450)were sensitive to imipenem/relebactam combination. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 64.6%(370/573),while more than 80.0% of CRAB complex was sensitive to tigecycline,eravacycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 17.0%(99/581). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of important Gram-negative bacteria resistance among different regions in China,with statistically significant differences in the prevalence of CREC,CRKP,CRPA and CRAB complex( χ2=10.6,28.6,10.8 and 19.3, P<0.05). The prevalence of ESBL-producing Escherichia coli, CREC,CRAB complex and CRKP were higher in provincial hospitals than those in municipal hospitals( χ2=12.5,9.8,12.7 and 57.8,all P<0.01). Conclusions:Gram-negative bacteria are the main pathogens causing bloodstream infections in China,and Escherichia coli is ranked in the top,while the trend of Klebsiella pneumoniae increases continuously with time. CRKP infection shows a slow upward trend,CREC infecton maintains a low prevalence level,and CRAB complex infection continues to exhibit a high prevalence rate. The composition and resistance patterns of pathogens causing bloodstream infections vary to some extent across different regions and levels of hospitals in China.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail