1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Regulation of TGF-β1/JNK signaling pathway in patients with different types of mitral valve diseases complicated by atrial fibrillation
Chao CHANG ; Bo FU ; Xiaolong ZHU ; Chongjie ZHANG ; Xia ZHAO ; Hong TANG ; Xijun XIAO ; Yunpeng BAI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(02):291-299
Objective To investigate the regulatory mechanism of transforming growth factor-β1 (TGF-β1) in different types of mitral valvular disease (MVD) with atrial fibrillation (AF). Methods From August 2011 to August 2012, patients with moderate to severe MVD accompanied by AF who required mitral valve replacement at the Department of Cardiovascular Surgery, West China Hospital, Sichuan University, were included. Based on echocardiographic results, patients were divided into two groups: a mitral regurgitation (MR) with AF (MR-AF) group and a mitral stenosis (MS) with AF (MS-AF) group. Left atrial tissue samples were collected during surgery. Techniques such as enzyme-linked immunosorbent assay, real-time fluorescence quantitative polymerase chain reaction, immunohistochemistry, and Western blotting were used to detect key molecules in the TGF-β1/JNK pathway. Results Sixteen patients were enrolled. There were 8 patients in the MR-AF group, including 5 males and 3 females, with an average age of (41.38±11.19) years; and 8 patients in the MS-AF group, including 6 males and 2 females, with an average age of (43.12±5.30) years. The left atrial volume load was higher in MR-AF patients, while the left atrial pressure load was higher in MS-AF patients. In MS-AF patients, the relative expression levels of MAPK9, JUN, CASP3, BAX, and BCL2 mRNA in left atrial tissues were significantly upregulated. The serum TGF-β1 protein level and the relative expression levels of p-JNK, p-c-Jun, and Caspase-3 proteins in the left atrial tissues of the MR-AF group were higher. Myocardial cell damage was more severe in the MS-AF group, and the protein expression level of Bcl-2 was higher. Conclusion Different MVD have distinct hemodynamic characteristics. The myocardium of the left atrium in MR-AF patients is more prone to apoptosis, possibly through the activation of the TGF-β1/JNK signaling pathway.
4.Revision strategies for failed atlantoaxial dislocation surgery
Zexing CHEN ; Xiaobao ZOU ; Xinzhao HUANG ; Junlin CHEN ; Rencai MA ; Zhishun XIAO ; Mandi CAI ; Hong XIA ; Xiangyang MA
Chinese Journal of Orthopaedics 2025;45(17):1128-1136
Objective:To analyze the revision strategies for failed atlantoaxial dislocation (AAD) surgery.Methods:A retrospective analysis was conducted on 145 patients who underwent revision surgery for AAD at the General Hospital of Southern Theatre Command of PLA between September 2009 and December 2023. The cohort included 74 males and 71 females, with a mean age of 43±16 years (range, 6-72 years). The initial surgical approaches were: anterior 31 cases, posterior 114 cases. Based on imaging assessments of immediate postoperative reduction and fusion status prior to revision, the cases of failure were classified into reduction-nonfusion type (22 cases), nonreduction-fusion type (31 cases), and nonreduction-nonfusion type (92 cases). Among the nonreduction-nonfusion cases, 39 had initial surgery with internal fixation for reduction, while 53 had initial surgery with simple decompression (posterior arch resection, foramen magnum decompression) without reduction. In the nonreduction-fusion cases, 8 cases had spot fusion and 23 had extensive fusion. Japanese Orthopaedic Association (JOA) scores were compared before and after revision, and complication rates were observed.Results:All patients successfully underwent surgery. The revision approaches included: anterior (anterior fixation and fusion 52 cases, anterior implant removal combined anterior fixation and fusion 4 cases, transoral odontoidectomies 16 cases, anterior implant removal combined transoral odontoidectomy 2 cases), posterior (posterior fixation and fusion 2 cases, posterior implant removal combined posterior fixation and fusion 22 cases), and combined anterior-posterior (posterior implant removal combined anterior fixation and fusion 18 cases, anterior implant removal combined posterior fixation and fusion 25 cases, posterior implant removal combined transoral odontoidectomy 5 cases). Operative time was 254.20±107.63 min (range, 90-660 min), and blood loss was 218.83±172.17 ml (range, 20-800 ml). Except for 3 patients who died due to postoperative complications, all patients were followed up for a duration of 12±11 months (range, 3-60 months). Six patients who failed to achieve bony fusion after the initial revision surgery underwent a second revision due to poor reduction (1 case), infection (1 case), suboptimal implant position (3 cases), and graft nonunion (1 case). All three patients with bony fusion after the initial revision surgery underwent a second revision due to poor reduction. Following the second revision surgery, none of the 9 patients exhibited graft nonunion or spinal cord compression. The 136 successful initial revision cases had a final follow-up JOA score of 14.75±2.00, significantly higher than the preoperative score of 11.93±2.92 ( t=-18.869, P<0.001). Conclusions:Revision surgery for AAD should take into account the immediate postoperative reduction status and fusion status prior to revision. An appropriate revision strategy should be selected to achieve satisfactory reduction and bony fusion.
5.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
6.Correlation between hemoglobin,anemia and sarcopenia in the elderly population
Hong-Zhen CHEN ; Kun ZHENG ; Xiao-Xue WU ; Li XIA
Medical Journal of Chinese People's Liberation Army 2025;50(4):444-451
Objective To analyze the correlation between hemoglobin(Hb),anemia,and sarcopenia in the elderly population in Chongqing communities.Methods A cross-sectional study was conducted on elderly individuals who underwent healthy examinations at 5 community health service centers in Chongqing from March to August 2023.Demographic characteristics,social factors,body composition measurement,grip strength,6-meter gait speed and blood tests were assessed.Receiver operating characteristic(ROC)curve was utilized to evaluate the accuracy of Hb in predicting sarcopenia,and the Youden index was employed to determine the optimal Hb cut-off value for diagnosing sarcopenia and its components.Both unadjusted and adjusted logistic regression analyses were performed to examine the relationship between Hb and anemia with sarcopenia and its components.Results A total of 531 elderly populations were included,with an average age of(71.1±6.5)years.The overall prevalence of sarcopenia was 13.6%(72/531),including 29 males(40.3%)and 43 females(59.7%).Unadjusted analyses showed that Hb was correlated with sarcopenia,decreased muscle mass,slower gait speed,and reduced grip strength(P<0.05).After adjusting for all potential risk factors,Hb was still significantly associated with sarcopenia and reduced grip strength(P<0.05).For every 10 g/L increase in Hb,the risk of sarcopenia decreased by 2.3%,and the risk of reduced grip strength decreased by 1.7%(P<0.05).Anemia was correlated with sarcopenia,reduced muscle mass,and decreased grip strength in unadjusted analyses(P<0.05),while the correlation between anemia and reduced grip strength remained significant after adjustment for all potential risk factors(P<0.05).The optimal Hb cut-off value for diagnosing sarcopenia in males and females were 148 g/L and 128 g/L,respectively.Conclusions Hb is an independent risk factor for sarcopenia and reduced grip strength.Anemia is associated with sarcopenia,but is not an independent risk factor for sarcopenia.
7.Effect of donepezil combined with hypoxia on CYP3A4 and its safety-evaluation
Xiao-xia HAN ; Yue-xin LI ; Wei TENG ; Fang WANG ; Hai-ying HONG ; Ze-shuai YI ; Ying SONG ; Yu-yan ZHOU ; Bao-xin LI ; Pan FAN
Chinese Pharmacological Bulletin 2025;41(12):2354-2361
Aim To investigate the regulatory mecha-nisms of donepezil on the expression and enzymatic ac-tivity of cytochrome P450 3A4(CYP3A4),elucidate the synergistic impact of hypoxia on CYP3A4 function,and reveal its potential association with drug-induced cardiotoxicity,particularly QT interval prolongation.Methods Western blot,co-immunoprecipitation,and gene knockdown techniques were employed to evaluate the effects of donepezil and hypoxia on CYP3A4 pro-tein expression.CYP3A4 enzymatic activity was as-sessed using an in vitro incubation system with rat liver microsomes combined with high-performance liquid chromatography(HPLC),and the half-maximal inhib-itory concentration(IC50)was determined.Results Donepezil(10 μmol·L-1)and hypoxia reduced CYP3A4 protein expression to 31.75%and 45.90%of the control levels,respectively.Both interventions activated the gp78-mediated ubiquitin-proteasome path-way,significantly increasing CYP3A4 ubiquitination levels by 2.1-fold compared to the control group,thereby promoting proteasomal degradation.Donepezil inhibited CYP3A4 enzyme activity with an IC50 of 83.4μmol·L-1,and hypoxia synergistically enhanced this inhibitory effect,reducing the IC50 to 20.79 μmol·L-1.Conclusion Donepezil downregulates CYP3A4 function through dual mechanisms involving ubiquitin-mediated proteasomal degradation and direct enzymatic inhibition.Hypoxia potentiates this effect,leading to impaired metabolism of CYP3A4 substrate drugs,ele-vated plasma drug concentrations(1.6-2.3-fold in-crease compared to normal metabolic conditions),and an increased risk of QT interval prolongation and other forms of cardiotoxicity.
8.Development of A High-performance Rectangular Ion Trap for Multi-reflection Time-of-Flight Mass Spectrometer
Xiao-Xia CHEN ; Yi REN ; Qi HUANG ; Da-Jun XIANG ; Chang-Wei LI ; Yi HONG ; Lei LI ; Zheng-Xu HUANG ; Mei LI ; Jing-Wei XU ; Zhen ZHOU
Chinese Journal of Analytical Chemistry 2025;53(1):38-46
As a new generation of time-of-flight mass spectrometry,multiple-reflection time-of-flight mass spectrometry(MR-TOF-MS)has been increasingly applied in the fields such as nuclear physics,chemistry,and biology due to its ultra-high resolution and rapid analysis capabilities.However,the analytical performance of MR-TOF-MS largely depends on the ion bunch state entering the mass analyzer.In this study,a rectangular ion trap(RIT)was developed,designed and processed using printed circuit board technology,as an ion accumulating and focusing device for MR-TOF mass analyzer.Compared to traditional ion traps composed of two sets of planar electrodes,this RIT had higher voltage utilization efficiency,resulting in more efficient ion collection and focusing.The ions were cooled to a sufficiently small bunch for precise mass measurement with MR-TOF-MS mass spectrometry in only 1 ms of cooling time in the RIT,then orthogonally ejected to the MR-TOF mass spectrometer for mass analysis.Experimental results indicated that the working cycle,ion flux,and ion focusing state of the RIT fully met the requirements of the MR-TOF mass analyzer.When coupled with the MR-TOF mass analyzer,the RIT enabled MR-TOF-MS to achieve a mass resolution of 1.5×105.
9.Dual-modal Magnetic Resonance Imaging Contrast Agents Based on Polymetallic Nanoclusters for Targeted Diagnosis of Prostate Cancer
Qing-Dong LI ; Peng WANG ; Jian-Min XIAO ; Wen-Juan GAO ; Zhen-Hong XIA ; Gui-Long ZHANG ; Zheng-Yan WU
Chinese Journal of Analytical Chemistry 2025;53(4):602-611
Fe/Mn/Gd polymetallic nanooxide(FMGN)were prepared by one-step solvent thermal reaction by using Fe(acac)3,Mn(acac)2 and Gd(acac)3 as reaction precursors.Next,hyaluronic acid(HA)was used to modify FMGN to fabricate tumor-targeting T 1-T 2 dual-mode magnetic resonance imaging(MRI)contrast agent(HA-FMGN)for accurate diagnosis of prostate cancer.The structure and morphology of FMGN were observed by transmission electron microscope(TEM).It was found that FMGN exhibited a uniform nanocluster spherical structure when the feeding ratio of iron acetylacetonate,manganese acetylacetonate,and gadolinium acetylacetonate was 3:2:1.X-ray diffraction(XRD)analysis showed that FMGN had a typical inverse spinel structure of Mn doped Fe 3O 4,with Gd existing in the form of amorphous gadolinium oxide.The longitudinal relaxivity(r 1)and transverse relaxivity(r 2)of FMGN were 13.395 and 428.535 L/(mmol·s),respectively,measured by 0.5 T MRI analyzer,which proved that FMGN had excellent T 1-T 2 dual-mode MRI contrast capability.The cytotoxicity and hemolysis test found that HA-FMGN didn't damage red cells and induce toxicity for normal cells,indicating that HA-FMGN had excellent cell biocompatibility.The internalization efficacy of HA-FMGN was observed by CLSM,and the results showed that HA-FMGN possessed excellent prostate tumor-targeting ability.In vivo MRI experiment showed that HA-FMGN significantly enhanced T 1 and T 2 weighted MRI signal to noise ratio(SNR)of prostate tumor,which promoted the accurate diagnosis of orthotopic prostate cancer.
10.Study on Colorimetric Sensor Array Based on Enzymatic Method for Highly Selective Detection of Sarin
Lian-Bo JIANG ; Guo-Hong LIU ; Zhuang-Hu XU ; Jian LI ; Yong-Ling SHEN ; Cai-Xia XU ; Chuan-Qin ZANG ; Yan-Hua XIAO ; Dan-Ping LI ; Ting LIANG
Chinese Journal of Analytical Chemistry 2025;53(5):832-841,中插21-中插23
Sarin(GB)is a typical representative of nerve agents with high toxicity,and very low amount can cause death.GB can cause water and atmospheric environment poisoning,so the detection of GB in water and air is of great significance.In this work,a colorimetric sensor array(CSA)based on GB inhibition of cholinesterase activity was constructed to detect GB with high selectivity.A 4×4 colorimetric array was constructed using acetylcholinesterase(AChE),butyryl cholinesterase(BuChE)and the corresponding substrate acetylthiocholine iodide(S-ACh),butyryl thiocholine iodide(S-BCh),acetylcholine chloride(ACh),butyryl choline chloride(BCh)and 2,6-dichloroindophenol ethyl ester(DCIE).The linear curve of the sensor was Y=131.3×lgC+271.6(R2=0.997),where Y was the array response Euclidean distance,C was the concentration of GB(mg/L),the linear range was 0.03?0.32 mg/L,and the detection limit was 27.6 μg/L.The method could effectively distinguish chemical warfare agents(CWA)such as VX,Soman(GD),mustard gas(HD),Louie reagent(L),and had high anti-interference ability,sensitivity and good repeatability.It was successfully applied to the detection of GB in simulated water and simulated air samples,and the sample recovery rate was 97.2% ?100.9%.This method would be potentially applied to the field rapid detection of nerve agents.

Result Analysis
Print
Save
E-mail