1.Effect of fibroblast growth factor receptor 1 inhibitor on bone destruction in rats with collagen-induced arthritis
Haihui HAN ; Xiaohui MENG ; Bo XU ; Lei RAN ; Qi SHI ; Lianbo XIAO
Chinese Journal of Tissue Engineering Research 2025;29(5):968-977
BACKGROUND:Preliminary research by our group suggests that targeting fibroblast growth factor receptor 1(FGFR1)may be an effective strategy for treating RA. OBJECTIVE:To investigate the effects of an FGFR1 inhibitor(PD173074)on bone destruction in rats with collagen-induced arthritis. METHODS:Twenty-five female Sprague-Dawley rats were randomly divided into five groups:normal control group,model group,methotrexate group,low-dose PD173074 group,and high-dose PD173074 group.Except for the normal control group,rat models of type Ⅱ collagen-induced arthritis were made in each group.After successful modeling,rats were injected intraperitoneally with sterile PBS in the normal and model groups,1.04 mg/kg methotrexate in the methotrexate group,and 5 and 20 mg/kg in the low-dose group and high-dose PD173074 groups,once a week.After 4 weeks of drug administration,clinical symptoms and joint swelling in rats were observed.Micro-CT was used for three-dimensional reconstruction and analysis of the ankle joints.Pathological changes in the ankle joints were observed.Periarticular angiogenesis and the expression of receptor activator of nuclear factor-Κb ligand were detected.The expression levels of p-FGFR1,vascular endothelial growth factor A,and tartrate-resistant acid phosphatase in the synovial membrane were measured.Pathological changes in the liver,spleen,and kidney were observed and liver,spleen,and kidney indices were calculated. RESULTS AND CONCLUSION:PD173074 could alleviate clinical symptoms and joint swelling,delay bone loss,improve bone structure,reduce synovial invasion and cartilage bone erosion,reduce the number of periarticular osteoclasts,inhibit angiogenesis in synovial tissues,reduce the expression of receptor activator of nuclear factor-Κb ligand,and inhibit the expression of FGFR1 phosphorylated protein,tartrate-resistant acid phosphatase and vascular endothelial growth factor A.Pathologic observation of the liver,spleen and kidney in rats showed no obvious toxic side effects after PD173074 treatment.To conclude,the FGFR1 inhibitor can delay the progression of joint inflammation and bone destruction and inhibit angiogenesis in the rat model of type Ⅱ collagen-induced arthritis.The therapeutic effect of PD173074 has been preliminarily validated in the type Ⅱ collagen-induced arthritis model and may act by inhibiting FGFR1 phosphorylation,which provides a direction for the search of new therapeutic targets for rheumatoid arthritis.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Progress on antisense oligonucleotide in the field of antibacterial therapy
Jia LI ; Xiao-lu HAN ; Shi-yu SONG ; Jin-tao LIN ; Zhi-qiang TANG ; Zeng-ming WANG ; Liang XU ; Ai-ping ZHENG
Acta Pharmaceutica Sinica 2025;60(2):337-347
With the widespread use of antibiotics, drug-resistant bacterial infections have become a significant threat to human health. Finding new antibacterial strategies that can effectively control drug-resistant bacterial infections has become an urgent task. Unlike small molecule drugs that target bacterial proteins, antisense oligonucleotide (ASO) can target genes related to bacterial resistance, pathogenesis, growth, reproduction and biofilm formation. By regulating the expression of these genes, ASO can inhibit or kill bacteria, providing a novel approach for the development of antibacterial drugs. To overcome the challenge of delivering antisense oligonucleotide into bacterial cells, various drug delivery systems have been applied in this field, including cell-penetrating peptides, lipid nanoparticles and inorganic nanoparticles, which have injected new momentum into the development of antisense oligonucleotide in the antibacterial realm. This review summarizes the current development of small nucleic acid drugs, the antibacterial mechanisms, targets, sequences and delivery vectors of antisense oligonucleotide, providing a reference for the research and development of antisense oligonucleotide in the treatment of bacterial infections.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Clinical evaluation of centrally procured generic and original esomeprazole for the treatment of acute non-variceal upper gastrointestinal bleeding
Si SU ; Shaowei HAN ; Haicai ZHUANG ; Na XU ; Ying LI ; Xiao WANG ; Kuan LI
China Pharmacy 2025;36(13):1635-1640
OBJECTIVE To evaluate the efficacy, safety and economics of the centrally procured generic versus original esomeprazole in the treatment of acute non-variceal upper gastrointestinal bleeding (ANVUGIB). METHODS A retrospective collection of real-world clinical data was conducted for ANVUGIB patients who received treatment at Shenzhen People’s Hospital and University of Hong Kong-Shenzhen Hospital from January 2018 to March 2024. Patients were divided into imported original drug group (original drug group, 221 cases) and centrally procured generic drug group (generic drug group, 75 cases) according to the types of drug used. Propensity score matching (PSM) was performed at a ratio of 3∶1 to compare the clinical efficacy, safety and economics between the two groups. RESULTS Totally 241 patients were included after PSM, with 170 in the original drug group and 71 in the generic drug group. There were no significant differences between the two groups in terms of rebleeding rate, rate of second endoscopic intervention, blood transfusion rate, length of hospital stay, mortality due to gastrointestinal bleeding, 30-day readmission due to rebleeding, and overall survival rate (P>0.05). The incidence of adverse events among all patients in both groups also showed no statistically significant difference (P>0.05); furthermore, the adverse events reported by the respective hospitals to the National Center for ADR Monitoring were comparable between the two groups. After PSM, the median total drug cost and high-dose esomeprazole cost in the generic drug group were significantly lower than those in the original drug group, while the median nursing fee and bed fee were significantly higher than those in the original drug group (P<0.05). There was no statistically significant difference between the two groups in terms of median total hospitalization expenses, total treatment costs, laboratory fees, examination fees, material costs, or consultation fees (P>0.05). CONCLUSIONS The clinical efficacy and safety of centrally procured generic esomeprazole in the treatment of ANVUGIB are comparable to those of the original drug, and it is more economical.
9.Progress in non-pharmacological strategies of heart failure with preserved ejection fraction
Xiao-Ming XU ; Yun-Long XIA ; Lin-Ying XIA ; Yong-Zhen GUO ; Quan-Chi LIU ; Xue HAN ; Wen-Jun YAN
Chinese Journal of Interventional Cardiology 2024;32(9):528-534
Heart failure with preserved ejection fraction(HFpEF)is a highly heterogeneous systemic condition and represents the predominant form of heart heart failure(HF)worldwide.Current pharmacotherapies for HFpEF are limited and lack specific targeted drugs.Recent studies suggest that non-pharmacological strategies serve as adjuncts to conventional pharmacological treatment,offering improvements in symptoms,quality of life,and reducing the risk of rehospitalization for HF in patients with HFpEF.These strategies include CD34 stem cell transplantation,the greater splanchnic nerve ablation,atrial septal shunting,atrial pacing,myocardial contractility modulation,left ventricular expander,baroreceptor stimulation,and others.This review comprehensively summarizes the latest clinical evidence on non-pharmacological treatments for HFpEF,with the aim of advancing the understanding of treatment strategies for this condition.
10.Clinical characteristics of patients with MitraClip operation and predictors for the occurrence of afterload mismatch
Xiao-Dong ZHUANG ; Han WEN ; Ri-Hua HUANG ; Xing-Hao XU ; Shao-Zhao ZHANG ; Zhen-Yu XIONG ; Xin-Xue LIAO
Chinese Journal of Interventional Cardiology 2024;32(10):562-568
Objective To explore the risk factors related to afterload mismatch(AM)after transcatheter mitral valve repair(MitraClip).Methods This was a retrospective cohort study.48 patients hospitalized in the Department of Cardiovascular Medicine,the First Affiliated Hospital of Sun Yat-sen University from December 2021 to December 2023,who underwent MitraClip due to severe mitral regurgitation(MR)were included.Preoperative clinical data,laboratory tests,and preoperative and postoperative color Doppler echocardiographic examination results of surgical patients were collected.AM was defined as the left ventricular ejection fraction(LVEF)decreased by 15%or more after surgery compared with the one before(dLVEF≤-15%).Patients were divided into AM group and non-AM group according to whether afterload mismatch occurred.Univariate and multivariate logistic regression were used to analyze the risk factors of postoperative AM.Results Among 48 patients who underwent MitraClip,14 of them(29.2%)developed afterload-mismatched.For those without AM,their overall LVEF was improved after the operation;for patients in both AM group and non-AM group,their overall left ventricular end-diastolic diameter(LVEDd),left ventricular end-diastolic diameter volume index(LVEDVi)was reduced compared with the preoperative ones.Univariate regression analysis showed that C-reactive protein levels(OR 1.98,95%CI 1.02-3.83),platelets(OR 2.22,95%CI 1.08-4.53),systemic immune inflammation index(OR 1.96,95%CI 1.03-3.71)were associated with an increased risk of AM in patients undergoing MitraClip(all P<0.05),while those with larger right atrial diameter(OR 0.35,95%CI 0.13-0.93)or moderate to severe tricuspid regurgitation(OR 0.19,95%CI 0.05-0.81)were less likely to develop into AM(both P<0.05),which is still satisfied after adjustment.Conclusions For patients who underwent MitraClip,C-reactive protein levels,platelets and systemic immune inflammation index(SII)are associated with an increased risk of afterload mismatched,while those with larger right atrial diameter or moderate to severe tricuspid regurgitation were less likely to develop into AM.

Result Analysis
Print
Save
E-mail