1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Effect of total flavonoids of Dracocephalum moldavica on TMAO-mediated JAK/STAT axis against atherosclerosis in rats and inflammation in RAW264.7 cells
Wen-Jiang CAO ; Chun-Yan DU ; Chuan-Sheng HUANG ; Yun-Li ZHAO ; Xiao-Li MA ; Yong YUAN ; Xin-Chun WANG
Chinese Pharmacological Bulletin 2024;40(9):1766-1772
Aim To investigate the protective effect of total flavonoids of Dracocephalum moldavica(TFDM)on atherosclerosis in rats and the inflammation of mouse macrophage RAW264.7 aggravated by trimeth-ylamine N-oxide(TMAO)and its possible mecha-nism.Methods The AS model of SD rats was estab-lished by high-fat diet feeding combined with intraper-itoneal injection of vitamin D3.The rats were divided into control group,model group,simvastatin group(15 mg·kg-1)and TFDM group(60,30,15 mg·kg-1).Biochemical method was used to detect the levels of se-rum total cholesterol(TC),triglyceride(TG)and low density lipoprotein cholesterol(LDL-C).HE staining was used to detect the pathological changes of aortic tissue.ELISA kit was used to detect the expression of TMAO,IL-1β,IL-6 in serum and TNF-α in liver tis-sue.Western blot was used to detect the expression of JAK,STAT and TNF-α protein in aorta.In addition,RAW264.7 macrophages were cultured in vitro,and LPS+TMAO was used to establish a macrophage in-flammation model,which was intervened by TFDM(100,50,25 mg·L-1).CCK-8 was used to determine cell viability and proliferation,and RT-qPCR was used to detect the expression of TNF-α,IL-6,JAK and STAT mRNA in cells.Results TFDM could significantly down-regulate the levels of serum TC,TG,LDL-C,ser-um TMAO,IL-1β,IL-6 and liver TNF-α,reduce aortic plaque deposition,and down-regulate the protein ex-pression of TNF-α,JAK and STAT in aorta.In addi-tion,TFDM intervention can significantly down-regulate the expression of TNF-α,IL-6,JAK,STAT mRNA and the expression of JAK,STAT protein.Conclusion TFDM can reduce the content of TMAO in serum,in-hibit JAK/STAT inflammatory signaling pathway and slow down the occurrence of inflammation,playing an anti-AS role.
7.Analysis of tuberculosis epidemiological characteristics and drug resistance among the floating population in Beijing in 2019.
Xin Yu YANG ; Shuang Shuang CHEN ; Jun Li YI ; Yan Feng ZHAO ; Hao CHEN ; Xiao Wei DAI ; Bei Chuan DING ; Meng Di PANG ; Qiao LI ; Zhegn Ying ZHAO ; Chuan You LI
Chinese Journal of Epidemiology 2023;44(6):949-953
Objective: To analyze the epidemic characteristics and drug resistance of pulmonary tuberculosis among the floating population in Beijing and to provide a scientific basis for formulating strategies for the prevention and control of tuberculosis among the floating population. Methods: Data of tuberculosis patients who were positive for Mycobacterium tuberculosis culture was collected from 16 districts and one municipal institution of tuberculosis control and prevention in Beijing in 2019. The strain samples were tested for drug sensitivity by the proportional method. According to household registration location, patients were divided into the floating population and Beijing registration. SPSS 19.0 software analyzed tuberculosis patients' epidemic characteristics and drug resistance in the floating population. Results: In 2019, there were 1 171 culture-positive tuberculosis patients in Beijing, among the floating population, 593 (50.64%) patients were identified, with a male-to-female sex ratio of 2.2∶1 (409∶184). Compared to patients under household registration as Beijing residents, a higher proportion of young adults aged 20-39 years (65.09%,386/593) were noticed, with 55.65% (330/593) reported from the urban areas and 96.80% (574/593) were reported the first time. The differences were statistically significant (all P<0.05). After completing the drug sensitivity test, 37 cases were with multiple drug-resistant tuberculosis, accounting for 6.24% (37/593). The rates of isoniazid resistance (42.11%,8/19) and multidrug resistance (21.05%,4/19) in floating population patients after retreatment were significantly higher than those in newly treated patients (11.67%, 67/574 and 5.75%, 33/574), and the differences were statistically significant (all P<0.05). Conclusions: Most patients with tuberculosis in the floating population in Beijing in 2019 were young males aged 20-39 years. The reporting areas were urban areas and the newly treated patients mainly. The patients with tuberculosis in the re-treated floating population were more likely to suffer from multidrug and drug resistance, which should be taken as the key population for prevention and control.
Young Adult
;
Humans
;
Female
;
Male
;
Beijing/epidemiology*
;
Tuberculosis
;
Tuberculosis, Pulmonary/epidemiology*
;
Tuberculosis, Multidrug-Resistant/epidemiology*
;
Drug Resistance
8.Clinical characteristics and serious complications of esophageal button battery ingestion in the pediatric on 83 cases.
Feng Zhen ZHANG ; Qing Chuan DUAN ; Gui Xiang WANG ; Xiao Jian YANG ; Wei ZHANG ; Jing ZHAO ; Hua WANG ; Hong Bin LI ; Xin NI ; Jie ZHANG
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(5):481-485
Objective: To analyze the clinical characteristics and complications of esophageal foreign bodies of button battery ingestion in children. Methods: A retrospective descriptive study included 83 children who were hospitalized in our hospital on account of button battery ingestion from January 2011 to December 2021. There were 50 males (60.2%) and 33 females (39.8%). The age ranged from 7.6 months to one month off 10 years, with a median age of 18 months. The data of patient demographics and time from ingestion to admission, location, symptoms, management, complications, and follow-up outcome were recorded. SPSS17.0 software was used for statistical analysis. Results: Seventy-two children (86.7%) were younger than 3 years old. The time from ingestion to admission ranged from 1 h to 2 months, with a median time of 8 h. Among the 63 children who were first diagnosed in our hospital, the most common clinical symptoms were nausea and vomiting (32 cases, 50.8%), dysphagia (31 cases, 49.2%), salivation (11 cases, 17.5%) and fever (10 cases, 15.9%). Seventy-three of 83 cases had complete preoperative diagnostic tests, and 55 cases (75.3%) were diagnosed by X-ray. In 56 cases (76.7%), the foreign badies were impacted in the upper third of esophagus. In 72 cases (86.7%), the foreign badies were removed by rigid esophagoscopy. 23 (27.7%) had serious complications, including tracheoesophageal fistula in 15 cases(TEF;65.2%), vocal cord paralysis (VCP;34.8%) in 8 cases, esophageal perforation in 3 cases (EP;13.0%), hemorrhage in 3 cases(13.0%), mediastinitis in 3 cases (13%), and periesophageal abscess in 1 case (4.3%). There were significant differences in the exposure time of foreign bodies and unwitnessed ingestion by guardians in the complications group (P<0.05). 2 cases died (2.4%)respectively due to arterial esophageal fistula bleeding and respiratory failure caused by stent displacement during the treatment of tracheoesophageal fistula. Conclusion: Accidental button battery ingestion can be life-threatening. and it mostly happens in children under 3 years old. Serious complications may happen cause of non-specific clinical manifestations and unwitnessed ingestions. Anterior and lateral chest X-ray is the first examination choice. Tracheoesophageal fistula is the most common serious complication.
Male
;
Female
;
Child
;
Humans
;
Infant
;
Child, Preschool
;
Tracheoesophageal Fistula/etiology*
;
Retrospective Studies
;
Foreign Bodies/diagnosis*
;
Eating
9.New model of PIRADS and adjusted prostatespecific antigen density of peripheral zone improves the detection rate of initial prostate biopsy: a diagnostic study.
Chen HUANG ; Zong-Qiang CAI ; Feng QIU ; Jin-Xian PU ; Qi-Lin XI ; Xue-Dong WEI ; Xi-Ming WANG ; Xiao-Jun ZHAO ; Lin-Chuan GUO ; Jian-Quan HOU ; Yu-Hua HUANG
Asian Journal of Andrology 2023;25(1):126-131
This study explored a new model of Prostate Imaging Reporting and Data System (PIRADS) and adjusted prostate-specific antigen density of peripheral zone (aPSADPZ) for predicting the occurrence of prostate cancer (PCa) and clinically significant prostate cancer (csPCa). The demographic and clinical characteristics of 853 patients were recorded. Prostate-specific antigen (PSA), PSA density (PSAD), PSAD of peripheral zone (PSADPZ), aPSADPZ, and peripheral zone volume ratio (PZ-ratio) were calculated and subjected to receiver operating characteristic (ROC) curve analysis. The calibration and discrimination abilities of new nomograms were verified with the calibration curve and area under the ROC curve (AUC). The clinical benefits of these models were evaluated by decision curve analysis and clinical impact curves. The AUCs of PSA, PSAD, PSADPZ, aPSADPZ, and PZ-ratio were 0.669, 0.762, 0.659, 0.812, and 0.748 for PCa diagnosis, while 0.713, 0.788, 0.694, 0.828, and 0.735 for csPCa diagnosis, respectively. All nomograms displayed higher net benefit and better overall calibration than the scenarios for predicting the occurrence of PCa or csPCa. The new model significantly improved the diagnostic accuracy of PCa (0.945 vs 0.830, P < 0.01) and csPCa (0.937 vs 0.845, P < 0.01) compared with the base model. In addition, the number of patients with PCa and csPCa predicted by the new model was in good agreement with the actual number of patients with PCa and csPCa in high-risk threshold. This study demonstrates that aPSADPZ has a higher predictive accuracy for PCa diagnosis than the conventional indicators. Combining aPSADPZ with PIRADS can improve PCa diagnosis and avoid unnecessary biopsies.
Male
;
Humans
;
Prostate/pathology*
;
Prostate-Specific Antigen/analysis*
;
Prostatic Neoplasms/diagnostic imaging*
;
Biopsy
;
Nomograms
;
Retrospective Studies
10.Determination of Serum Unbound Bilirubin and Its Clinical Application Value in Neonates
Yi-chu HUANG ; Xue-yu CHEN ; Yong YANG ; Xia-juan YU ; Xiao-mei QIU ; Jie ZHAO ; Xiao-yun XIONG ; Chuan-zhong YANG
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(2):318-325
ObjectiveTo investigate the clinical appropriateness and application value of the peroxidase (POD) method for the detection of unbound bilirubin (UB) in neonatal serum. MethodsHydrogen peroxide (0.33 mol/L) and three different final concentrations (0.019, 0.038, 0.075 μg/mL) of horseradish peroxidase (HRP) were added to standard bilirubin solution (1, 2, 3 μmol/L) to obtain a standardized HRP primary rate constant Kp. Then 25 μL of neonatal serum was diluted by 41.6 fold, and measured with 2.4 and 4.8 μg/mL HRP at 37 ℃ under the dark, to determine the UB concentration. The accuracy, precision, and stability of the methodology were validated. The clinical characteristics of 33 jaundiced neonates were collected, including total serum bilirubin (TSB), indirect bilirubin (IDB), albumin (ALB), bilirubin to albumin molar ratio (BAMR), etc. The experimental data were analyzed by Graphpad Prism 8.0. ResultsA standardized Kp of (7.20±1.08) mL·μg-1·min-1 was determined at pH 7.4±0.2, 37 ℃ in the dark. The HRP activity and UB concentrations remained stable at -20 ℃ for 3 weeks and a week, respectively. The mean intra-day and inter-day coefficients of variation of the serum samples with different UB concentrations were less than 10%. In this study, the UB concentrations in 33 jaundiced neonates (gestational age ≥35 weeks) were measured by the POD method in the range of (0.32~1.20) μg/dL, which was positively correlated with TSB, IDB and BAMR. Of the five infants whose UB concentrations measured more than 1 μg/dL, three received intensive phototherapy (60%). ConclusionsThe POD method combined with a standard equipment spectrophotometer to detect serum UB concentrations in neonates is easy to operate, rapid to detect, and low cost. This method has good accuracy and precision, which is convenient for clinical implementation. Moreover, the measurement of serum UB may assist us in better management of neonatal jaundice in clinical practice.

Result Analysis
Print
Save
E-mail