1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Effect of total flavonoids of Dracocephalum moldavica on TMAO-mediated JAK/STAT axis against atherosclerosis in rats and inflammation in RAW264.7 cells
Wen-Jiang CAO ; Chun-Yan DU ; Chuan-Sheng HUANG ; Yun-Li ZHAO ; Xiao-Li MA ; Yong YUAN ; Xin-Chun WANG
Chinese Pharmacological Bulletin 2024;40(9):1766-1772
Aim To investigate the protective effect of total flavonoids of Dracocephalum moldavica(TFDM)on atherosclerosis in rats and the inflammation of mouse macrophage RAW264.7 aggravated by trimeth-ylamine N-oxide(TMAO)and its possible mecha-nism.Methods The AS model of SD rats was estab-lished by high-fat diet feeding combined with intraper-itoneal injection of vitamin D3.The rats were divided into control group,model group,simvastatin group(15 mg·kg-1)and TFDM group(60,30,15 mg·kg-1).Biochemical method was used to detect the levels of se-rum total cholesterol(TC),triglyceride(TG)and low density lipoprotein cholesterol(LDL-C).HE staining was used to detect the pathological changes of aortic tissue.ELISA kit was used to detect the expression of TMAO,IL-1β,IL-6 in serum and TNF-α in liver tis-sue.Western blot was used to detect the expression of JAK,STAT and TNF-α protein in aorta.In addition,RAW264.7 macrophages were cultured in vitro,and LPS+TMAO was used to establish a macrophage in-flammation model,which was intervened by TFDM(100,50,25 mg·L-1).CCK-8 was used to determine cell viability and proliferation,and RT-qPCR was used to detect the expression of TNF-α,IL-6,JAK and STAT mRNA in cells.Results TFDM could significantly down-regulate the levels of serum TC,TG,LDL-C,ser-um TMAO,IL-1β,IL-6 and liver TNF-α,reduce aortic plaque deposition,and down-regulate the protein ex-pression of TNF-α,JAK and STAT in aorta.In addi-tion,TFDM intervention can significantly down-regulate the expression of TNF-α,IL-6,JAK,STAT mRNA and the expression of JAK,STAT protein.Conclusion TFDM can reduce the content of TMAO in serum,in-hibit JAK/STAT inflammatory signaling pathway and slow down the occurrence of inflammation,playing an anti-AS role.
7.A nomogram for preoperative prediction of lymph node metastasis in patients with intrahepatic cholangiocarcinoma based on inflammation-related markers.
Xiao Peng YU ; Jia Lu CHEN ; Yue TANG ; Chen CHEN ; Ying Hong QIU ; Hong WU ; Tian Qiang SONG ; Yu HE ; Xian Hai MAO ; Wen Long ZHAI ; Zhang Jun CHENG ; Xiao LIANG ; Jing Dong LI ; Chuan Dong SUN ; Kai MA ; Rui Xin LIN ; Zhi Min GENG ; Zhao Hui TANG ; Zhi Wei QUAN
Chinese Journal of Surgery 2023;61(4):321-329
Objectives: To construct a nomogram for prediction of intrahepatic cholangiocarcinoma (ICC) lymph node metastasis based on inflammation-related markers,and to conduct its clinical verification. Methods: Clinical and pathological data of 858 ICC patients who underwent radical resection were retrospectively collected at 10 domestic tertiary hospitals in China from January 2010 to December 2018. Among the 508 patients who underwent lymph node dissection,207 cases had complete variable clinical data for constructing the nomogram,including 84 males,123 females,109 patients≥60 years old,98 patients<60 years old and 69 patients were pathologically diagnosed with positive lymph nodes after surgery. Receiver operating characteristic curve was drawn to calculate the accuracy of preoperative imaging examinations to determine lymph node status,and the difference in overall survival time was compared by Log-rank test. Partial regression squares and statistically significant preoperative variables were screened by backward stepwise regression analysis. R software was applied to construct a nomogram,clinical decision curve and clinical influence curve,and Bootstrap method was used for internal verification. Moreover,retrospectively collecting clinical information of 107 ICC patients with intraoperative lymph node dissection admitted to 9 tertiary hospitals in China from January 2019 to June 2021 was for external verification to verify the accuracy of the nomogram. 80 patients with complete clinical data but without lymph node dissection were divided into lymph node metastasis high-risk group and low-risk group according to the score of the nomogram among the 858 patients. Log-rank test was used to compare the overall survival of patients with or without lymph node metastasis diagnosed by pathology. Results: The area under the curve of preoperative imaging examinations for lymph node status assessment of 440 patients was 0.615,with a false negative rate of 62.8% (113/180) and a false positive rate of 14.2% (37/260). The median survival time of 207 patients used to construct a nomogram with positive or negative postoperative pathological lymph node metastases was 18.5 months and 27.1 months,respectively (P<0.05). Five variables related to lymph node metastasis were screened out by backward stepwise regression analysis,which were combined calculi,neutrophil/lymphocyte ratio,albumin,liver capsule invasion and systemic immune inflammation index,according to which a nomogram was constructed with concordance index(C-index) of 0.737 (95%CI: 0.667 to 0.806). The C-index of external verification was 0.674 (95%CI:0.569 to 0.779). The calibration prediction curve was in good agreement with the reference curve. The results of the clinical decision curve showed that when the risk threshold of high lymph node metastasis in the nomogram was set to about 0.32,the maximum net benefit could be obtained by 0.11,and the cost/benefit ratio was 1∶2. The results of clinical influence curve showed that when the risk threshold of high lymph node metastasis in the nomogram was set to about 0.6,the probability of correctly predicting lymph node metastasis could reach more than 90%. There was no significant difference in overall survival time between patients with high/low risk of lymph node metastasis assessed by the nomogram and those with pathologically confirmed lymph node metastasis or without lymph node metastasis (Log-rank test:P=0.082 and 0.510,respectively). Conclusion: The prediction accuracy of preoperative nomogram for ICC lymph node metastasis based on inflammation-related markers is satisfactory,which can be used as a supplementary method for preoperative diagnosis of lymph node metastasis and is helpful for clinicians to make personalized decision of lymph node dissection for patients with ICC.
8.New model of PIRADS and adjusted prostatespecific antigen density of peripheral zone improves the detection rate of initial prostate biopsy: a diagnostic study.
Chen HUANG ; Zong-Qiang CAI ; Feng QIU ; Jin-Xian PU ; Qi-Lin XI ; Xue-Dong WEI ; Xi-Ming WANG ; Xiao-Jun ZHAO ; Lin-Chuan GUO ; Jian-Quan HOU ; Yu-Hua HUANG
Asian Journal of Andrology 2023;25(1):126-131
This study explored a new model of Prostate Imaging Reporting and Data System (PIRADS) and adjusted prostate-specific antigen density of peripheral zone (aPSADPZ) for predicting the occurrence of prostate cancer (PCa) and clinically significant prostate cancer (csPCa). The demographic and clinical characteristics of 853 patients were recorded. Prostate-specific antigen (PSA), PSA density (PSAD), PSAD of peripheral zone (PSADPZ), aPSADPZ, and peripheral zone volume ratio (PZ-ratio) were calculated and subjected to receiver operating characteristic (ROC) curve analysis. The calibration and discrimination abilities of new nomograms were verified with the calibration curve and area under the ROC curve (AUC). The clinical benefits of these models were evaluated by decision curve analysis and clinical impact curves. The AUCs of PSA, PSAD, PSADPZ, aPSADPZ, and PZ-ratio were 0.669, 0.762, 0.659, 0.812, and 0.748 for PCa diagnosis, while 0.713, 0.788, 0.694, 0.828, and 0.735 for csPCa diagnosis, respectively. All nomograms displayed higher net benefit and better overall calibration than the scenarios for predicting the occurrence of PCa or csPCa. The new model significantly improved the diagnostic accuracy of PCa (0.945 vs 0.830, P < 0.01) and csPCa (0.937 vs 0.845, P < 0.01) compared with the base model. In addition, the number of patients with PCa and csPCa predicted by the new model was in good agreement with the actual number of patients with PCa and csPCa in high-risk threshold. This study demonstrates that aPSADPZ has a higher predictive accuracy for PCa diagnosis than the conventional indicators. Combining aPSADPZ with PIRADS can improve PCa diagnosis and avoid unnecessary biopsies.
Male
;
Humans
;
Prostate/pathology*
;
Prostate-Specific Antigen/analysis*
;
Prostatic Neoplasms/diagnostic imaging*
;
Biopsy
;
Nomograms
;
Retrospective Studies
9.Analysis of tuberculosis epidemiological characteristics and drug resistance among the floating population in Beijing in 2019.
Xin Yu YANG ; Shuang Shuang CHEN ; Jun Li YI ; Yan Feng ZHAO ; Hao CHEN ; Xiao Wei DAI ; Bei Chuan DING ; Meng Di PANG ; Qiao LI ; Zhegn Ying ZHAO ; Chuan You LI
Chinese Journal of Epidemiology 2023;44(6):949-953
Objective: To analyze the epidemic characteristics and drug resistance of pulmonary tuberculosis among the floating population in Beijing and to provide a scientific basis for formulating strategies for the prevention and control of tuberculosis among the floating population. Methods: Data of tuberculosis patients who were positive for Mycobacterium tuberculosis culture was collected from 16 districts and one municipal institution of tuberculosis control and prevention in Beijing in 2019. The strain samples were tested for drug sensitivity by the proportional method. According to household registration location, patients were divided into the floating population and Beijing registration. SPSS 19.0 software analyzed tuberculosis patients' epidemic characteristics and drug resistance in the floating population. Results: In 2019, there were 1 171 culture-positive tuberculosis patients in Beijing, among the floating population, 593 (50.64%) patients were identified, with a male-to-female sex ratio of 2.2∶1 (409∶184). Compared to patients under household registration as Beijing residents, a higher proportion of young adults aged 20-39 years (65.09%,386/593) were noticed, with 55.65% (330/593) reported from the urban areas and 96.80% (574/593) were reported the first time. The differences were statistically significant (all P<0.05). After completing the drug sensitivity test, 37 cases were with multiple drug-resistant tuberculosis, accounting for 6.24% (37/593). The rates of isoniazid resistance (42.11%,8/19) and multidrug resistance (21.05%,4/19) in floating population patients after retreatment were significantly higher than those in newly treated patients (11.67%, 67/574 and 5.75%, 33/574), and the differences were statistically significant (all P<0.05). Conclusions: Most patients with tuberculosis in the floating population in Beijing in 2019 were young males aged 20-39 years. The reporting areas were urban areas and the newly treated patients mainly. The patients with tuberculosis in the re-treated floating population were more likely to suffer from multidrug and drug resistance, which should be taken as the key population for prevention and control.
Young Adult
;
Humans
;
Female
;
Male
;
Beijing/epidemiology*
;
Tuberculosis
;
Tuberculosis, Pulmonary/epidemiology*
;
Tuberculosis, Multidrug-Resistant/epidemiology*
;
Drug Resistance
10.Determination of Serum Unbound Bilirubin and Its Clinical Application Value in Neonates
Yi-chu HUANG ; Xue-yu CHEN ; Yong YANG ; Xia-juan YU ; Xiao-mei QIU ; Jie ZHAO ; Xiao-yun XIONG ; Chuan-zhong YANG
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(2):318-325
ObjectiveTo investigate the clinical appropriateness and application value of the peroxidase (POD) method for the detection of unbound bilirubin (UB) in neonatal serum. MethodsHydrogen peroxide (0.33 mol/L) and three different final concentrations (0.019, 0.038, 0.075 μg/mL) of horseradish peroxidase (HRP) were added to standard bilirubin solution (1, 2, 3 μmol/L) to obtain a standardized HRP primary rate constant Kp. Then 25 μL of neonatal serum was diluted by 41.6 fold, and measured with 2.4 and 4.8 μg/mL HRP at 37 ℃ under the dark, to determine the UB concentration. The accuracy, precision, and stability of the methodology were validated. The clinical characteristics of 33 jaundiced neonates were collected, including total serum bilirubin (TSB), indirect bilirubin (IDB), albumin (ALB), bilirubin to albumin molar ratio (BAMR), etc. The experimental data were analyzed by Graphpad Prism 8.0. ResultsA standardized Kp of (7.20±1.08) mL·μg-1·min-1 was determined at pH 7.4±0.2, 37 ℃ in the dark. The HRP activity and UB concentrations remained stable at -20 ℃ for 3 weeks and a week, respectively. The mean intra-day and inter-day coefficients of variation of the serum samples with different UB concentrations were less than 10%. In this study, the UB concentrations in 33 jaundiced neonates (gestational age ≥35 weeks) were measured by the POD method in the range of (0.32~1.20) μg/dL, which was positively correlated with TSB, IDB and BAMR. Of the five infants whose UB concentrations measured more than 1 μg/dL, three received intensive phototherapy (60%). ConclusionsThe POD method combined with a standard equipment spectrophotometer to detect serum UB concentrations in neonates is easy to operate, rapid to detect, and low cost. This method has good accuracy and precision, which is convenient for clinical implementation. Moreover, the measurement of serum UB may assist us in better management of neonatal jaundice in clinical practice.

Result Analysis
Print
Save
E-mail