1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Observation on therapeutic effect of self-made auxiliary reduction device combined with sinus tarsi approach in treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures
Yu ZHOU ; Da-gang TANG ; Wei PENG ; Xiao-bo HU ; Zhi CHEN ; Peng LONG ; Zhi-ping KUANG ; Chuan-zhi ZHANG
Journal of Regional Anatomy and Operative Surgery 2025;34(7):604-609
Objective To observe the efficacy of self-made auxiliary reduction device combined with sinus tarsi approach(STA)in the treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures.Methods A total of 40 patients with Sanders type Ⅱ to Ⅳ calcaneal fractures admitted to our hospital from January to June 2023 were selected and divided into the control group and the observation group by the random number table method,with 20 cases in each group.Patients in the control group underwent surgical treatment with the heel extensile lateral approach(ELA),while patients in the observation group underwent surgical treatment with the auxiliary reduction device combined with STA.The surgical-related indicators,postoperative complications and ankle-foot anatomical indicators of patients in the two groups were compared.The recovery of limb function was evaluated by the American Orthopaedic Foot and Ankle Society(AOFAS)ankle-hindfoot scale and Maryland foot function score.Results There was no statistically significant difference in the operation time,postoperative incision drying time,or duration of postoperative pain between the two groups(P>0.05).The postoperative suture removal time of the patients in the observation group was shorter than that of the control group,and the difference was statistically significant(P<0.05).The incidence of skin edge necrosis of incision and the total incidence of complications of patients in the observation group were significantly lower than those in the control group(P<0.05).The B?hler angle and Gissane angle of patients in both groups increased after surgery compared with those before surgery(P<0.05);there was no statistically significant difference in the B?hler angle or Gissane angle after surgery of patients between the two groups(P>0.05).The AOFAS score1 week after surgery of the patients in the observation group was higher than that in the control group(P<0.05),while there were no statistically significant differences in the AOFAS scores or Maryland scores of patients at other time points between the two groups(P>0.05).Conclusion The use of the auxiliary reduction device in surgical treatment with STA for Sanders type Ⅱ to Ⅳ calcaneal fractures can effectively restore the function of the foot and ankle,with short postoperative suture removal time and low incidence of postoperative complications.
4.Analysis of 408 cases of tigecycline-related adverse reactions
Xiao LIU ; Jingyu LIN ; Simiao ZHAO ; Bo ZHENG ; Ying ZHOU
Adverse Drug Reactions Journal 2025;27(11):674-680
Objective:To analyze the clinical characteristics of tigecycline-related adverse reactions and provide the basis for the safe and rational use of the drug.Methods:Adverse reaction reports with suspected drug as tigecycline from Beijing Adverse Drug Reaction Monitoring Center from January 1st, 2019 to June 30th, 2024 were collected. The adverse reaction reports were standardized using the preferred term (PT) and system organ class (SOC) in the Chinese updated edition (2015 version) of the World Health Organization Adverse Reaction Terminology. The patients' general condition, tigecycline use, and adverse reaction occurrence (including latency, severity, treatment, outcome, and correlation evaluation) were descriptively and statistically analyzed. Results:A total of 408 tigecycline-related adverse reaction reports were entered, including 153 females (37.5%) and 255 males (62.5%). The age was (68±21) years, ranging from 2 to 99. The main reasons for tigecycline use were infections of lung, blood flow, skin and skin soft tissue, etc. The pathogens were mainly Klebsiella pneumoniae, Acinetobacter baumanii, Escherichia coli, etc. The usage and dosage of tigecycline in most patients were in line with the instructions. Four hundred and eight adverse event reports involved 11 SOCs and 580 PTs. The top 3 SOCs were gastrointestinal diseases (195 case times, 33.62%), vascular, bleeding and coagulation diseases (183 case times, 31.55%), and hepatobiliary diseases (142 case times, 24.48%). The main clinical manifestations were nausea, vomiting, diarrhea, etc. The main laboratory abnormalities were decreased plasma fibrinogen, decreased platelet count, increased alanine aminotransferase, increased aspartate aminotransferase, and increased bilirubin. There were 27 case times of adverse reactions that were not recorded in the instructions, mainly including leukopenia, abdominal distension, fever, dysbacteriosis, etc. The latency of adverse reactions ranged from 5 min to 65 days, with a median time of 5 days. The grade of adverse reactions was general in 379 patients (92.89%) and severe in 29 patients (7.11%). The top 3 SOCs involved in 53 case times of severe adverse reactions were hepatobiliary diseases (30 case times, 56.60%), vascular, bleeding and coagulation diseases (8 case times, 15.09%), and urinary tract diseases (4 case times, 7.55%), the main clinical manifestations were elevated liver enzymes, coagulation disorders, pancreatitis, etc. After the occurrence of adverse reactions, all patients stopped tigecycline, and received symptomatic treatments such as liver protection, intravenous infusion of human fibrinogen, intravenous infusion of platelets, and antidiarrheal therapy. Among 408 patients, 66 (16.18%) were cured, 297 (72.79%) were improved, 20 (4.90%) were not improved, and 25 cases' outcome (6.13%) were unknown. The shortest time for recovery or improvement was 0.5 hour, the longest was 44 days, with a median time of 5 days. The correlation between tigecycline and adverse reactions was probable in 132 patients (32.35%), and possible in 276 patients (67.65%). Conclusions:Tigecycline-related adverse reactions involve multiple organ systems, mainly including gastrointestinal diseases, vascular, bleeding and coagulation diseases, and hepatobiliary diseases, etc. which can lead to severe adverse reactions such as acute pancreatitis and coagulation disorders. After drug withdrawal and symptomatic treatments, most patients had a good prognosis.
5.Specific effect of inserted sham acupuncture and its impact on the estimation of acupuncture treatment effect in randomized controlled trials: A systematic survey.
Xiao-Chao LUO ; Jia-Li LIU ; Ming-Hong YAO ; Ye-Meng CHEN ; Arthur Yin FAN ; Fan-Rong LIANG ; Ji-Ping ZHAO ; Ling ZHAO ; Xu ZHOU ; Xiao-Ying ZHONG ; Jia-Hui YANG ; Bo LI ; Ying ZHANG ; Xin SUN ; Ling LI
Journal of Integrative Medicine 2025;23(6):630-640
BACKGROUND:
The use of inserted sham acupuncture as a placebo in randomized controlled trials (RCTs) is controversial, because it may produce specific effects that cause an underestimation of the effect of acupuncture treatment.
OBJECTIVE:
This systematic survey investigates the magnitude of insert-specific effects of sham acupuncture and whether they affect the estimation of acupuncture treatment effects.
SEARCH STRATEGY:
PubMed, Embase and Cochrane Central Register of Controlled Trials were searched to identify acupuncture RCTs from their inception until December 2022.
INCLUSION CRITERIA:
RCTs that evaluated the effects of acupuncture compared to sham acupuncture and no treatment.
DATA EXTRACTION AND ANALYSIS:
The total effect measured for an acupuncture treatment group in RCTs were divided into three components, including the natural history and/or regression to the mean effect (controlled for no-treatment group), the placebo effect, and the specific effect of acupuncture. The first two constituted the contextual effect of acupuncture, which is mimicked by a sham acupuncture treatment group. The proportion of acupuncture total effect size was considered to be 1. The proportion of natural history and/or regression to the mean effect (PNE) and proportional contextual effect (PCE) of included RCTs were pooled using meta-analyses with a random-effect model. The proportion of acupuncture placebo effect was the difference between PCE and PNE in RCTs with non-inserted sham acupuncture. The proportion of insert-specific effect of sham acupuncture (PIES) was obtained by subtracting the proportion of acupuncture placebo effect and PNE from PCE in RCTs with inserted sham acupuncture. The impact of PIES on the estimation of acupuncture's treatment effect was evaluated by quantifying the percentage of RCTs that the effect of outcome changed from no statistical difference to statistical difference after removing PIES in the included studies, and the impact of PIES was externally validated in other acupuncture RCTs with an inserted sham acupuncture group that were not used to calculate PIES.
RESULTS:
This analysis included 32 studies with 5492 patients. The overall PNE was 0.335 (95% confidence interval [CI], 0.255-0.415) and the PCE of acupuncture was 0.639 (95% CI, 0.567-0.710) of acupuncture's total effect. The proportional contribution of the placebo effect to acupuncture's total effect was 0.191, and the PIES was 0.189. When we modeled the exclusion of the insert-specific effect of sham acupuncture, the acupuncture treatment effect changed from no difference to a significant difference in 45.45% of the included RCTs, and in 40.91% of the external validated RCTs.
CONCLUSION
The insert-specific effect of sham acupuncture in RCTs represents 18.90% of acupuncture's total effect and significantly affects the evaluation of the acupuncture treatment effect. More than 40% of RCTs that used inserted sham acupuncture would draw different conclusions if the PIES had been controlled for. Considering the impact of the insert-specific effect of sham acupuncture, caution should be taken when using inserted sham acupuncture placebos in RCTs. Please cite this article as: Luo XC, Liu JL, Yao MH, Chen YM, Fan AY, Liang FR, Zhao JP, Zhao L, Zhou X, Zhong XY, Yang JH, Li B, Zhang Y, Sun X, Li L. Specific effect of inserted sham acupuncture and its impact on the estimation of acupuncture treatment effect in randomized controlled trials: A systematic survey. J Integr Med. 2025; 23(6):630-640.
Acupuncture Therapy/methods*
;
Humans
;
Randomized Controlled Trials as Topic
;
Placebo Effect
;
Placebos
;
Treatment Outcome
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Adolescent anxiety and non-suicidal self-injury behavior: the mediating role of depression and the moderating role of social support
Juexi LI ; Liyuan LI ; Yuxuan GUO ; Xiaoqiang XIAO ; Peiqi TANG ; Ting PU ; Haixi ZUO ; Ting YANG ; Xiaoxia FAN ; Bo ZHOU
Sichuan Mental Health 2025;38(4):357-363
BackgroundNon-suicidal self-injury (NSSI) behavior among adolescents has become a global public health concern. Anxiety and depression are considered key factors influencing NSSI behavior, while social support may play a protective role in alleviating emotional and behavioral issues. However, existing research has primarily focused on the direct impact of individual factors on NSSI behavior, with insufficient exploration of the combined effects of anxiety, depression and social support. ObjectiveTo investigate the direct effect of anxiety on NSSI, the mediating role of depression and the moderating role of social support in relationship between anxiety and NSSI behavior, thus to provide references for the prevention and intervention of NSSI behavior among adolescents. MethodsIn February 2022, a total of 40 820 students in grades 7 to 12 across 10 middle schools in a district of Chengdu were selected as participants, and they were assessed using Generalized Anxiety Disorder Scale-7 item (GAD-7), Patient's Health Questionnaire Depression Scale-9 item (PHQ-9), Social Support Scale for Urban Students (SSSUS) and Adolescent Self-Harm Scale (ASHS). Pearson correlation analysis was conducted to examine the correlations between scale scores among adolescents with NSSI behaviors. Mediation and moderation analyses were performed using Process 3.5 in SPSS, and the significance was tested with bootstrapping. The interaction was visualized by using simple slope analysis. ResultsAmong 34 534 (84.60%) valid respondents, 542 adolescents (1.57%) reported engaging in NSSI behavior. Significant differences in gender, GAD-7 scores, PHQ-9 scores, and SSSUS scores were observed between NSSI behavior group and non-NSSI group (χ²/t=62.889, 71.120, 94.365, -41.464, P<0.01).Adolesents with NSSI showed positive correlations between GAD-7 scores and both ASHS and PHQ-9 scores (r=0.158, 0.166, P<0.01). PHQ-9 scores were positively correlated with ASHS scores (r=0.364, P<0.01), but negatively correlated with SSSUS scores (r=-0.290, P<0.01). SSSUS scores were negatively correlated with ASHS scores (r=-0.247, P<0.01). Depression partially mediated the relationship between anxiety and NSSI behavior, with an effect size of 0.544 (95% CI: 0.162~0.944), accounting for 35.79% of the total effect. Social support moderated the relationship between depression and NSSI bahavior, with an effect value of -0.082 (95% CI: -0.135~-0.029). ConclusionAnxiety not only directly influences NSSI bahavior among adolescents, also indirectly exacerbates it through depression, while social support mitigates the impact of depression on NSSI behavior. [Funded by Youth Project of National Natural Science Foundation of China (number, 82401812); Project of Health Commission of Sichuan Province (number, 24LCYJPT18)]
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Laboratory Diagnosis and Molecular Epidemiological Characterization of the First Imported Case of Lassa Fever in China.
Yu Liang FENG ; Wei LI ; Ming Feng JIANG ; Hong Rong ZHONG ; Wei WU ; Lyu Bo TIAN ; Guo CHEN ; Zhen Hua CHEN ; Can LUO ; Rong Mei YUAN ; Xing Yu ZHOU ; Jian Dong LI ; Xiao Rong YANG ; Ming PAN
Biomedical and Environmental Sciences 2025;38(3):279-289
OBJECTIVE:
This study reports the first imported case of Lassa fever (LF) in China. Laboratory detection and molecular epidemiological analysis of the Lassa virus (LASV) from this case offer valuable insights for the prevention and control of LF.
METHODS:
Samples of cerebrospinal fluid (CSF), blood, urine, saliva, and environmental materials were collected from the patient and their close contacts for LASV nucleotide detection. Whole-genome sequencing was performed on positive samples to analyze the genetic characteristics of the virus.
RESULTS:
LASV was detected in the patient's CSF, blood, and urine, while all samples from close contacts and the environment tested negative. The virus belongs to the lineage IV strain and shares the highest homology with strains from Sierra Leone. The variability in the glycoprotein complex (GPC) among different strains ranged from 3.9% to 15.1%, higher than previously reported for the seven known lineages. Amino acid mutation analysis revealed multiple mutations within the GPC immunogenic epitopes, increasing strain diversity and potentially impacting immune response.
CONCLUSION
The case was confirmed through nucleotide detection, with no evidence of secondary transmission or viral spread. The LASV strain identified belongs to lineage IV, with broader GPC variability than previously reported. Mutations in the immune-related sites of GPC may affect immune responses, necessitating heightened vigilance regarding the virus.
Humans
;
China/epidemiology*
;
Genome, Viral
;
Lassa Fever/virology*
;
Lassa virus/classification*
;
Molecular Epidemiology
;
Phylogeny

Result Analysis
Print
Save
E-mail