1.Spatiotemporal Electrical Impedance Tomography for Speech Respiratory Assessment in Cleft Palate: an Interpretable Machine Learning Study
Yang WU ; Xiao-Jing ZHANG ; Hao YU ; Cheng-Hui JIANG ; Bo SUN ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2026;53(2):485-500
ObjectiveCleft palate (CP) is a common congenital deformity often associated with velopharyngeal insufficiency (VPI), which disrupts the physiological coupling between respiration and speech. Conventional clinical assessments, such as nasometry and spirometry, provide limited static data and fail to visualize the dynamic spatiotemporal distribution of lung ventilation during phonation. This study introduces spatiotemporal electrical impedance tomography (ST-EIT) to evaluate speech-respiratory functional features in CP patients compared to normal controls (NC). The aim is to characterize multi-domain respiratory patterns and to validate an interpretable machine learning framework for providing objective, quantitative evidence for clinical assessment. MethodsSeventy-five participants were enrolled in this study, comprising 37 patients with surgically repaired CP and 38 healthy volunteers matched for age, gender, and body mass index (BMI). All subjects performed standardized sustained phonation tasks while undergoing synchronous monitoring with a 16-electrode EIT system and a pneumotachograph. A comprehensive feature engineering pipeline was developed to extract physiological parameters across 3 complementary domains. (1) Temporal domain: including inspiratory/expiratory phase duration (tPhase), time constants (Tau), and inspiratory-to-expiratory time ratios (TI/TE); (2) airflow domain: comprising mean flow, peak flow, and instantaneous flow at 25%, 50%, and 75% of tidal volume; and (3) spatial domain: quantifying global and regional tidal impedance variation (TIV), global inhomogeneity (GI), and center of ventilation (CoV). Extreme Gradient Boosting (XGBoost) classifiers were trained using 5 distinct data sources (Spirometry, Nasometry, Inspiratory-EIT, Expiratory-EIT, and fused ST-EIT). Model performance was rigorously evaluated via stratified 5-fold cross-validation, and Shapley additive explanations (SHAP) were employed to quantify global and local feature contributions. ResultsThe CP group exhibited a distinct respiratory phenotype compared to controls. In the temporal domain, CP patients showed significantly shorter inspiratory (1.60 s vs.1.85 s, P<0.001) and expiratory phase durations (2.45 s vs. 3.95 s, P<0.001), indicating a rapid, shallow breathing rhythm. In the airflow domain, while inspiratory flows were comparable, the CP group demonstrated significantly elevated mean and peak flows during the expiratory phase (P<0.001), reflecting compensatory respiratory effort. Spatially, CP patients presented significant ventilation redistribution, characterized by higher regional TIV in the right-anterior (ROI1) and left-posterior (ROI4) quadrants, but lower TIV in the left-anterior (ROI2) quadrant. In terms of diagnostic accuracy, the multi-modal ST-EIT model achieved the highest performance (AUC: 0.915±0.012, Accuracy: 0.843±0.019, F1-score: 0.872±0.017), substantially outperforming models based on spirometry (AUC: 0.721) or nasometry (AUC: 0.625) alone. Interpretability analysis revealed that spatial domain features were the most critical, contributing 53.4% to the model’s decision-making, followed by temporal (25.0%) and airflow (21.6%) features. ConclusionST-EIT successfully captures the temporal, airflow, and spatial deviations in CP speech respiration that are undetectable by conventional methods—specifically, rapid phase transitions, hyperdynamic expiratory airflow, and regional ventilation heterogeneity. This study validates ST-EIT as a robust, non-invasive, and radiation-free tool for characterizing speech-respiratory dysfunction, offering high clinical value for bedside screening, rehabilitation planning, and longitudinal monitoring of patients with cleft palate.
2.Spatiotemporal Electrical Impedance Tomography for Speech Respiratory Assessment in Cleft Palate: an Interpretable Machine Learning Study
Yang WU ; Xiao-Jing ZHANG ; Hao YU ; Cheng-Hui JIANG ; Bo SUN ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2026;53(2):485-500
ObjectiveCleft palate (CP) is a common congenital deformity often associated with velopharyngeal insufficiency (VPI), which disrupts the physiological coupling between respiration and speech. Conventional clinical assessments, such as nasometry and spirometry, provide limited static data and fail to visualize the dynamic spatiotemporal distribution of lung ventilation during phonation. This study introduces spatiotemporal electrical impedance tomography (ST-EIT) to evaluate speech-respiratory functional features in CP patients compared to normal controls (NC). The aim is to characterize multi-domain respiratory patterns and to validate an interpretable machine learning framework for providing objective, quantitative evidence for clinical assessment. MethodsSeventy-five participants were enrolled in this study, comprising 37 patients with surgically repaired CP and 38 healthy volunteers matched for age, gender, and body mass index (BMI). All subjects performed standardized sustained phonation tasks while undergoing synchronous monitoring with a 16-electrode EIT system and a pneumotachograph. A comprehensive feature engineering pipeline was developed to extract physiological parameters across 3 complementary domains. (1) Temporal domain: including inspiratory/expiratory phase duration (tPhase), time constants (Tau), and inspiratory-to-expiratory time ratios (TI/TE); (2) airflow domain: comprising mean flow, peak flow, and instantaneous flow at 25%, 50%, and 75% of tidal volume; and (3) spatial domain: quantifying global and regional tidal impedance variation (TIV), global inhomogeneity (GI), and center of ventilation (CoV). Extreme Gradient Boosting (XGBoost) classifiers were trained using 5 distinct data sources (Spirometry, Nasometry, Inspiratory-EIT, Expiratory-EIT, and fused ST-EIT). Model performance was rigorously evaluated via stratified 5-fold cross-validation, and Shapley additive explanations (SHAP) were employed to quantify global and local feature contributions. ResultsThe CP group exhibited a distinct respiratory phenotype compared to controls. In the temporal domain, CP patients showed significantly shorter inspiratory (1.60 s vs.1.85 s, P<0.001) and expiratory phase durations (2.45 s vs. 3.95 s, P<0.001), indicating a rapid, shallow breathing rhythm. In the airflow domain, while inspiratory flows were comparable, the CP group demonstrated significantly elevated mean and peak flows during the expiratory phase (P<0.001), reflecting compensatory respiratory effort. Spatially, CP patients presented significant ventilation redistribution, characterized by higher regional TIV in the right-anterior (ROI1) and left-posterior (ROI4) quadrants, but lower TIV in the left-anterior (ROI2) quadrant. In terms of diagnostic accuracy, the multi-modal ST-EIT model achieved the highest performance (AUC: 0.915±0.012, Accuracy: 0.843±0.019, F1-score: 0.872±0.017), substantially outperforming models based on spirometry (AUC: 0.721) or nasometry (AUC: 0.625) alone. Interpretability analysis revealed that spatial domain features were the most critical, contributing 53.4% to the model’s decision-making, followed by temporal (25.0%) and airflow (21.6%) features. ConclusionST-EIT successfully captures the temporal, airflow, and spatial deviations in CP speech respiration that are undetectable by conventional methods—specifically, rapid phase transitions, hyperdynamic expiratory airflow, and regional ventilation heterogeneity. This study validates ST-EIT as a robust, non-invasive, and radiation-free tool for characterizing speech-respiratory dysfunction, offering high clinical value for bedside screening, rehabilitation planning, and longitudinal monitoring of patients with cleft palate.
3.Mosquito monitoring and influence of meteorological factors on mosquito density around Beijing Capital International Airport, 2016-2022
Ran FENG ; Tie-zheng MA ; Si-jie ZHU ; Bo TIAN ; Fei QUAN ; Zhi-lin WU ; Xiao-tao LIU ; Fu-yuan ZHANG ; Song-jian ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):40-48
Objective To understand mosquito density, species composition, and seasonal variations around the Beijing Capital International Airport(BCIA)and provide scientific evidence for mosquito-borne disease prevention and control. Methods Meteorological data were collected from 2016 to 2022, and mosquito density was monitored at seven surveillance sites around the BCIA from May to October each year using CO2-baited mosquito traps to analyze the relationship between mosquito density and meteorological factors. Results In total,68 518 female mosquitoes were captured, with a mosquito density of 10.20 per light · hour. The dominant species was Culex pipiens pallens(73.90%), followed by Aedes albopictus(9.71%)and Ae. vexans(9.29%);the mosquito density was highest in 2016(14.8 per light·hour)and lowest in 2022(4.46 per light·hour). Significant statistical differences were observed in mosquito density among different species(F=18.118, P<0.05). The density of Cx. pipiens pallens and other mosquito species showed a mutually exclusive trend; the peak of mosquito density varied based on years and habitats, with significant statistical differences in mosquito density among different habitats(F=8.504, P<0.05). The highest mosquito density was observed near the Wenyu River(21.50 per light·hour), whereas the lowest was recorded at the BCIA construction site(2.44 per light· hour). The monthly average temperature(r=0.595), monthly average highest temperature(r=0.575), and monthly average lowest temperature(r=0.624)showed moderate positive correlations, whereas the monthly average air pressure(r=-0.484)showed a moderate negative correlation. The monthly average minimum temperature was included in the regression model(F=25.575, P<0.000), and the equation Y=1.029X4-8.181 was used. The monthly average air pressure 2 months prior(b=-2.418, β=-1.619, P<0.05)and the monthly average relative humidity(b=-0.739, β=-1.201, P<0.05)significantly negatively predicted the mosquito density. Notably, the regression equation used was y=2526.170+(-2.418)X9+(-0.739)X13. The exposure-response analysis revealed that the density of mosquitoes was not linearly related to the average monthly air pressure, rainfall, and duration of sunshine. Conclusions The dominant mosquito species around the BCIA was Cx. pipiens pallens, Ae. albopictus, and Ae. vexans. During the control of Cx. pipiens pallens, the impact on other mosquito species must also be considered. Environmental management, breeding sites, and scientific use of pesticides should be prioritized based on the activity periods of mosquitoes. Further studies on mosquitoes and meteorological factors should be conducted to provide references and novel avenues for mosquito control.
4.Multidisciplinary expert consensus on weight management for overweight and obese children and adolescents based on healthy lifestyle
HONG Ping, MA Yuguo, TAO Fangbiao, XU Yajun, ZHANG Qian, HU Liang, WEI Gaoxia, YANG Yuexin, QIAN Junwei, HOU Xiao, ZHANG Yimin, SUN Tingting, XI Bo, DONG Xiaosheng, MA Jun, SONG Yi, WANG Haijun, HE Gang, CHEN Runsen, LIU Jingmin, HUANG Zhijian, HU Guopeng, QIAN Jinghua, BAO Ke, LI Xuemei, ZHU Dan, FENG Junpeng, SHA Mo, Chinese Association for Student Nutrition & ; Health Promotion, Key Laboratory of Sports and Physical Fitness of the Ministry of Education,〖JZ〗 Engineering Research Center of Ministry of Education for Key Core Technical Integration System and Equipment,〖JZ〗 Key Laboratory of Exercise Rehabilitation Science of the Ministry of Education
Chinese Journal of School Health 2025;46(12):1673-1680
Abstract
In recent years, the prevalence of overweight and obesity among children and adolescents has risen rapidly, posing a serious threat to their physical and mental health. To provide scientific, systematic, and standardized weight management guidance for overweight and obese children and adolescents, the study focuses on the core concept of healthy lifestyle intervention, integrates multidisciplinary expert opinions and research findings,and proposes a comprehensive multidisciplinary intervention framework covering scientific exercise intervention, precise nutrition and diet, optimized sleep management, and standardized psychological support. It calls for the establishment of a multi agent collaborative management mechanism led by the government, implemented by families, fostered by schools, initiated by individuals, optimized by communities, reinforced by healthcare, and coordinated by multiple stakeholders. Emphasizing a child and adolescent centered approach, the consensus advocates for comprehensive, multi level, and personalized guidance strategies to promote the internalization and maintenance of a healthy lifestyle. It serves as a reference and provides recommendations for the effective prevention and control of overweight and obesity, and enhancing the health level of children and adolescents.
5.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
6.Clinical study on neglected perforation of glove during spinal surgery
Xiao-fang SHAO ; Bo WANG ; Shan-shan TAN ; Wen-wen HE ; Yu-feng TIAN
Journal of Regional Anatomy and Operative Surgery 2025;34(5):417-420
Objective To specify the occurrence status,distribution characteristics and risk factors of neglected perforations in surgical gloves used during spinal surgery.Methods A total of 932 surgical gloves used during spinal surgery in our hospital from October 2022 to September 2024 were selected.The occurrence and distribution location of neglected perforations were counted.Univariate and binary Logistic regression analyses were respectively conducted on the factors that might lead to neglected perforations of gloves.Results Among the 932 surgical gloves used in spinal surgery selected in this study,a total of 122 gloves(13.09%)with neglected perforations were detected,of which the proportions of neglected perforations at the index finger of the left and right hands in the gloves were the highest,accounting for 37.50%and 37.93%respectively.The results of univariate and binary Logistic regression analyses showed that grade Ⅲ or Ⅳ surgery,open surgery,combined bone grafting operation,operation time≥120 minutes,use of rotating equipment,and gloves worn by instrument nurses were risk factors for neglected perforations(P<0.05,OR>1.0),while wearing double-layer gloves was a protective factor to avoid the occurrence of neglected perforations(P<0.05,OR<1.0).Conclusion The incidence of neglected perforations in surgical gloves used during spinal surgery is relatively high,especially in the area of the glove index finger.For high-risk spinal surgeries(grade Ⅲ or Ⅳ surgery,open surgeries,combined bone grafting procedures)and requiring rotating equipment,health care workers,especially instrumental nurses,are advised to wear double-layer gloves;furthermore,a 120-minute glove change regime is recommended,in order to reduce the incidence of neglected perforation.
7.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.
8.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.
9.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
10.Design and performance verification of high altitude adaptive oxygen generator
Bo WANG ; Xiao-feng LIU ; Wen-jia LIU ; Yi LI ; Ya-nan WU ; Shu-jie CUI ; Wei ZHANG
Chinese Medical Equipment Journal 2025;46(4):29-34
Objective To design a high altitude adaptive oxygen generator for the crews to alleviate their high altitude reaction in high altitude environment and meet their requirements for oxygen supply.Methods A high altitude adaptive oxygen generator based on the mature pressure swing adsorption oxygen production method was designed with the key technologies of discharge capacity compensation of air compression pump and airway fusion of molecular sieve tower,which had the components of molecular sieve tower,air compression pump,controller,cooling fan,cooler,solenoid valve,regulator,flow meter and etc.Trials were carried out at the simulated altitude and field plateau environment so as to verify the high altitude adaptive performance of the oxygen generator developed.Results The trial results showed the oxygen generator met the desired objectives and the requirements for oxygen volume fraction in GJB 2799-1996 General specification for medical oxygen generator using molecular sieve method.Conclusion The oxygen generartor provides oxygen supply effectively for vehicle operators in plateau environments or the ones rushing into the plateau.[Chinese Medical Equipment Journal,2025,46(4):29-34]


Result Analysis
Print
Save
E-mail