1.Bioequivalence study of pyrazinamide tablets in Chinese healthy subjects
Li-Bing YE ; Chong YAO ; Ying-Rong CHEN ; Lu-Yuan TONG ; Tao YANG ; Xiao LU ; Min XU ; Qiu-Yue JIN ; Shui-Xin YANG
The Chinese Journal of Clinical Pharmacology 2024;40(15):2236-2240
Objective To evaluate the bioequivalence and safety of two pyrazinamide tablets in healthy Chinese subjects.Methods An open,randomized,single-dose,two-sequence,two-cycle,double-cross trial design was used.All 48 healthy subjects(24 in fasting and 24 in fed trial)were randomized to receive a single oral dose of a 0.5 g pyrazinamide tablet(test or reference)per cycle.The plasma concentration of the drug was determined by liquid chromatography coupled to tandem mass spectrometry method.The pharmacokinetic parameters were calculated by WinNonlin v8.2,and the bioequivalence was evaluated by SAS 9.4.Results In the fasting group,the Cmax of the test and reference preparation of pyrazinamide tablets were(13.28±2.82)and(12.88±4.49)μg·mL-1,the AUC0-t were(139.17±26.58)and(138.63±28.92)h·μg·mL-1,the AUC0-∞ were(148.96±33.65)and(148.71±36.97)h·μg·mL-1 respectively.In the fed group,the Cmax of the test and reference preparation of pyrazinamide tablets were(11.89±1.96)and(11.99±1.92)μg·mL-1,the AUC0-t were(138.22±37.21)and(141.68±25.80)h·μg·mL-1,the AUC0-∞ were(152.20±32.41)and(151.04±28.05)h·μg·mL-,respectively.The 90%confidence intervals of Cmax,AUC0-t and AUC0-∞ geometric mean ratios of the test and reference preparation were all within 80.00%to 125.00%.The incidence of adverse events was 16.70%for both the test and reference preparation in the fasting group and 8.30%for both the test and reference preparation in the fed group,all of which were mild in severity.Conclusion The test and reference preparation of pyrazinamide tablets were bioequivalent,safe and well tolerated in healthy Chinese subjects under fasting and fed conditions.
2.Cellular Temperature Imaging Technology Based on Single-molecule Quantum Coherent Modulation
Hai-Tao ZHOU ; Cheng-Bing QIN ; Lian-Tuan XIAO ; Zhi-Fang WU ; Si-Jin LI
Progress in Biochemistry and Biophysics 2024;51(5):1215-1220
ObjectiveCellular temperature imaging can assist scientists in studying and comprehending the temperature distribution within cells, revealing critical information about cellular metabolism and biochemical processes. Currently, cell temperature imaging techniques based on fluorescent temperature probes suffer from limitations such as low temperature resolution and a limited measurement range. This paper aims to develop a single-cell temperature imaging and real-time monitoring technique by leveraging the temperature-dependent properties of single-molecule quantum coherence processes. MethodsUsing femtosecond pulse lasers, we prepare delayed and phase-adjustable pairs of femtosecond pulses. These modulated pulse pairs excite fluorescent single molecules labeled within cells through a microscopic system, followed by the collection and recording of the arrival time of each fluorescent photon. By defining the quantum coherence visibility (V) of single molecules in relation to the surrounding environmental temperature, a correspondence between V and environmental temperature is established. By modulating and demodulating the arrival times of fluorescent photons, we obtain the local temperature of single molecules. Combined with scanning imaging, we finally achieve temperature imaging and real-time detection of cells. ResultsThis method achieves high precision (temperature resolution<0.1°C) and a wide temperature range (10-50°C) for temperature imaging and measurement, and it enables the observation of temperature changes related to individual cell metabolism. ConclusionThis research contributes to a deeper understanding of cellular metabolism, protein function, and disease mechanisms, providing a valuable tool for biomedical research.
3.The Application of Aptamers in The Diagnosis and Therapy of Bladder Cancer
Shu-Wei FENG ; Min-Xin ZHANG ; Xiao-Qiu WU ; Heng-Yi LIN ; Tao BING
Progress in Biochemistry and Biophysics 2024;51(7):1566-1575
Bladder cancer is one of the most prevalent cancers worldwide, with a high rate of recurrence and mortality, which is the ninth most common malignancy globally. Cystoscopy remains the gold standard for clinical bladder cancer diagnosis, but its invasive nature can lead to bacterial infection and inflammation. Urine cytology is a non-invasive and simple diagnostic method, but it has lower sensitivity in detecting low-grade bladder cancer and may yield false negative results. Therefore, identifying ideal diagnostic and prognostic biomarkers is crucial for accurate diagnosis and effective treatment of bladder cancer. Aptamers, characterized as single-stranded DNA or RNA with unique three-dimensional conformations, exhibit the ability to identify various targets, ranging from small molecules to tumor cells. Aptamers, also known as chemical antibodies, are generated by systematic evolution of ligands by exponential enrichment (SELEX) process and can function similarly to traditional antibodies. They hold numerous advantages over antibodies, such as ease of modification, low immunogenicity, and rapid tissue penetration and cell internalization due to their nucleic acid molecule structure. Since their discovery in the 1990s, aptamers have been widely used in biochemical analysis, disease detection, new drug research and other fields. This article provides an overview of aptamer selection and characterization for bladder cancer, discussing the research advancements involving aptamers in diagnosing and treating this disease. It covers aptamers obtained through different SELEX methods, including protein-SELEX, cell-SELEX, tissue-SELEX, and aptamers from other cancer SELEX; the detection in blood samples and urine samples; and application in targeted therapy and immunotherapy for bladder cancer. Currently, several aptamers capable of identifying bladder cancer have been generated, serving as molecular probes that have played a pivotal role in the early detection and treatment of bladder cancer. Bladder cancer perfusion therapy is well-suited for aptamer drug therapy because it does not require internal circulation, making it a suitable clinical indication for aptamer drug development. In addition, bladder cancer can be detected and monitored by collecting urine samples from patients, making it a preferred disease for clinical conversion of aptamers. While aptamers show promise, there is still much room for development compared with antibodies. There are still many clinically applied cancer biomarkers without corresponding aptamers, and more aptamers targeting different biomarkers should be selected and optimized to improve the sensitivity and accuracy for cancer detection and therapy. The field of aptamers urgently needs successful commercial products to promote its development, and home rapid detection/monitoring, imaging and targeted therapy of bladder cancer by infusion may be the breakthrough point for future application of aptamers.
4.Raman Spectroscopy Analysis of The Temporal Heterogeneity in Lung Cell Carcinogenesis Induced by Benzo(a)pyrene
Hai-Tao ZHOU ; Wei YAO ; Cao-Zhe CUI ; Xiao-Tong ZHOU ; Xi-Long LIANG ; Cheng-Bing QIN ; Lian-Tuan XIAO ; Zhi-Fang WU ; Si-Jin LI
Progress in Biochemistry and Biophysics 2024;51(6):1458-1470
ObjectiveTemporal heterogeneity in lung cancer presents as fluctuations in the biological characteristics, genomic mutations, proliferation rates, and chemotherapeutic responses of tumor cells over time, posing a significant barrier to effective treatment. The complexity of this temporal variance, coupled with the spatial diversity of lung cancer, presents formidable challenges for research. This article will pave the way for new avenues in lung cancer research, aiding in a deeper understanding of the temporal heterogeneity of lung cancer, thereby enhancing the cure rate for lung cancer. MethodsRaman spectroscopy emerges as a powerful tool for real-time surveillance of biomolecular composition changes in lung cancer at the cellular scale, thus shedding light on the disease’s temporal heterogeneity. In our investigation, we harnessed Raman spectroscopic microscopy alongside multivariate statistical analysis to scrutinize the biomolecular alterations in human lung epithelial cells across various timeframes after benzo(a)pyrene exposure. ResultsOur findings indicated a temporal reduction in nucleic acids, lipids, proteins, and carotenoids, coinciding with a rise in glucose concentration. These patterns suggest that benzo(a)pyrene induces structural damage to the genetic material, accelerates lipid peroxidation, disrupts protein metabolism, curtails carotenoid production, and alters glucose metabolic pathways. Employing Raman spectroscopy enabled us to monitor the biomolecular dynamics within lung cancer cells in a real-time, non-invasive, and non-destructive manner, facilitating the elucidation of pivotal molecular features. ConclusionThis research enhances the comprehension of lung cancer progression and supports the development of personalized therapeutic approaches, which may improve the clinical outcomes for patients.
5.Clinical Efficacy of Chailian Lvping Granules on Post-Stroke Anxiety and Their Effect on Serum Neurotransmitter and Oxidative Stress
Jiang-Tao HUO ; Jin-Jin CAI ; Hui LIANG ; Gong-Bing GUO ; Xiao-Qiao ZHANG ; Lin LUO
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(9):2239-2245
Objective To investigate the clinical efficacy of Chailian Lvping Granules(mainly composed of Bupleuri Radix,Coptidis Rhizoma,Paeoniae Radix Alba,Angelicae Sinensis Radix,Salviae Miltiorrhizae Radix et Rhizoma,Citri Sarcodactylis Fructus,and Ziziphi Spinosae Semen)in treating post-stroke anxiety and to observe their effect on serum neurotransmitters and oxidative stress.Methods A total of 104 patients with post-stroke anxiety of liver-qi stagnation and heart-fire exuberance type were randomly divided into an observation group and a control group,52 cases in each group.The control group was treated with conventional western medicine of Paroxetine,and the observation group was treated with Chailian Lvping Granules on the basis of treatment for the control group.The course of treatment lasted for eight weeks.The two groups were observed in the changes of Hospital Anxiety and Depression Scale(HADS)score,Hamilton Anxiety Scale(HAMA)score,serum neurotransmitter parameters of brain-derived neurotrophic factor(BDNF),dopamine(DA),5-hydroxytryptamine(5-HT)and norepinephrine(NE),and oxidative stress indicators of malondialdehyde(MDA),superoxide dismutase(SOD),and glutathione peroxidase(GSH-Px)before and after treatment.Moreover,the clinical efficacy and total incidence of adverse reactions were compared between the two groups.Results(1)After eight weeks of treatment,the total effective rate of the observation group was 94.23%(49/52),and that of the control group was 76.92%(40/52).The intergroup comparison(tested by chi-square test)showed that the curative effect of the observation group was significantly superior to that of the control group(P<0.05).(2)After treatment,the HADS score and HAMA score for the axienty degree in the two groups were decreased compared with those before treatment(P<0.05),and the decrease of HADS score and HAMA score in the observation group was significantly superior to that in the control group(P<0.01).(3)After treatment,the serum level of neurotransmitter BDNF in the two groups was increased while the serum levels of DA,5-HT and NE were decreased compared with those before treatment(P<0.05).The increase of serum BDNF level and the decrease of serum DA,5-HT and NE levels in the observation group were significantly superior to those in the control group(P<0.01).(4)After treatment,the serum level of oxidative stress indicator MDA in the two groups was decreased while the serum levels of SOD and GSH-Px were increased compared with those before treatment(P<0.05).The decrease of serum MDA level and the increase of serum SOD and GSH-Px levels in the observation group were significantly superior to those in the control group(P<0.05 or P<0.01).(5)The total incidence of adverse reactions in the observation group was 5.77%(3/52),and that in the control group was 9.62%(5/52).There was no significant difference between the two groups(P>0.05).Conclusion On the basis of conventional western medicine treatment,Chailian Lvping Granules exert certain effect in the treatment of patients with post-stroke anxiety of liver-qi stagnation and heart-fire exuberance type.The combined therapy is effective and safe on alleviating the anxiety symptoms of patients,decreasing the degree of neurological impairment and stress response level,and has few adverse reactions.
6.Optical coherence tomography imaging in keratoconus
Bing-Qing SUN ; Xiao-Yu ZHANG ; Xing-Tao ZHOU
International Eye Science 2023;23(3):416-420
Keratoconus is a chronic, non-inflammatory corneal disease, characterized by thinning of the corneal stroma and local corneal dilation with cone-shaped protrusion, and it usually leads to irregular astigmatism and myopia, posing great threat to eyesight. Corneal topography is the primary diagnostic tool for confirming keratoconus, while optical coherence tomography is now playing an increasingly important role in the diagnosis and treatment of keratoconus due to its ability of corneal sublayer imaging and superiority in repeatability, resolution, and data acquisition speed. This article discusses and reviews the clinical characteristics of keratoconus, the classification and characteristics of optical coherence tomography and its novel applications in the early diagnosis of keratoconus, contact lens fitting, corneal cross-linking therapy, and corneal transplantation; furthermore, progress in derivative technologies including optical coherence elastography, optical coherence tomography angiography, and polarization-sensitive optical coherence tomography associated with keratoconus is included in this article. We hope our study will help to further exploit the role of optical coherence technology in clinical keratoconus management.
7.Development and characteristics of automatic ash-removal heat-sensitive moxibustion device.
Xue-Tao ZHANG ; Han-Xiao WANG ; Zhen WANG ; Ya-Lu WANG ; Shuai CUI ; Mei-Qi ZHOU ; Hui LUO ; Can-Guang SUN ; Ming HAO ; Wen HONG ; Sheng-Bing WU
Chinese Acupuncture & Moxibustion 2023;43(5):597-599
An automatic ash-removal heat-sensitive moxibustion device was developed, which could keep relatively constant temperature of heat-sensitive moxibustion, and realize the automatic ignition and automatic ash removal of moxa sticks during heat-sensitive moxibustion. The automatic ash-removal heat-sensitive moxibustion device comprises a bracket and a moxibustion box fixed on the top of the bracket; the bracket is composed of a base and a movable telescopic arm. This device can solve the problems of temperature instability, moxa ash blocking heat transfer and moxa ash falling during heat-sensitive moxibustion, avoiding the scalding caused by moxa ash falling, and reduce the workload of medical staff.
Humans
;
Hot Temperature
;
Moxibustion
;
Temperature
8.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
9.Research progress on biofilm microecology in chronic suppurative otitis media.
Xin Cheng ZHONG ; Xiao OUYANG ; Yu Bing LIAO ; Ming Zhu TAO ; Jiao PENG ; Zhi Qing LONG ; Xiang Jie GAO ; Ying CAO ; Ming Hua LUO ; Guo Jiang PENG ; Zhi Xiong ZHOU ; Guan Xiong LEI
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(6):621-625
10.Development and characteristics of auricular fumigation moxibustion combined with heat-sensitive moxibustion device.
Xue-Tao ZHANG ; Zhen WANG ; Han-Xiao WANG ; Ya-Lu WANG ; Xin WU ; Kun WANG ; Shuai CUI ; Mei-Qi ZHOU ; Hui LUO ; Can-Guang SUN ; Sheng-Bing WU
Chinese Acupuncture & Moxibustion 2023;43(11):1333-1337
A moxibustion device with the functions of auricular fumigation moxibustion and heat-sensitive moxibustion is designed. The smoke of the ignited moxa stick is used for the fumigation moxibustion at the external auditory canal, while the heat generated works on Dazhui (GV 14) for heat-sensitive moxibustion. The device consists of five parts, i.e. combustion chamber, smoke pipe, smoke processing chamber, power module and connector. It solves the limitations such as unpleasant experience in treatment, unfavorable temperature control, easy scalding and excessive manual dependence induced by usual fumigation moxibustion and during heat-sensitive moxibustion. This moxibustion device may improve the safety and convenience when delivering the treatment with fumigation moxibustion and heat-sensitive moxibustion, as well as the work efficiency of medical staff.
Humans
;
Moxibustion
;
Hot Temperature
;
Fumigation
;
Smoke
;
Temperature

Result Analysis
Print
Save
E-mail