1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Effect of Bushen Tiaojing Decoction Combined with Human Recombinant Interferon-α-2b on Humoral Immunity,CA125 and EMAb Levels in Patients with Endometriosis
Xiao-Bei KANG ; Hong-Jie YANG ; Xiu-Fang DU ; Chang-Na FU ; Tao YANG ; Wei-Wei SUN
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(6):1472-1478
Objective To investigate the efficacy of Bushen Tiaojing Decoction,a prescription derived from Daying Decoction which recorded in Jing Yue Quan Shu(The Complete Works of ZHANG Jing-Yue)and with herbs added,combined with human recombinant interferon-α-2b for the treatment of endometriosis(EMs)and to observe its effects on humoral immunity,serum carbohydrate antigen 125(CA125)and anti-endometrial antibody(EMAb)levels of EMs patients.Methods A total of 86 cases of EMs patients with kidney deficiency and blood stasis syndrome were randomly divided into observation group and control group,with 43 cases in each group.The control group was treated with human recombinant interferon-α-2b alone,and the observation group was treated with Bushen Tiaojing Decoction combined with human recombinant interferon-α-2b.The course of treatment covered one month.The changes of humoral immune factors of immunoglobulin A(IgA),complement 3(C3)and complement 4(C4),endometrial ectopic mass diameter,and the levels of pathology-relevant factors of CA1 25 and EMAb in the two groups before and after treatment were observed.Moreover,the clinical efficacy and safety of the two groups were evaluated.Results(1)After one month of treatment,the total effective rate of the observation group was 97.67%(42/43),and that of the control group was 81.40%(35/43).The intergroup comparison(tested by chi-square test)showed that the efficacy of the observation group was significantly superior to that of the control group(P<0.05).(2)After treatment,the serum IgA level of the two groups was significantly higher than that before treatment(P<0.05),and the serum C3 and C4 levels were significantly lower than those before treatment(P<0.05).The increase of serum IgA level and the decrease of serum C3 and C4 levels in the observation group were significantly superior to those in the control group(P<0.01).(3)After treatment,the serum CA125 and EMAb levels and the diameter of endometrial ectopic mass in the two groups were significantly lower than those before treatment(P<0.05),and the decrease of serum CA125 and EMAb levels and the diameter of endometriosis mass in the observation group was significantly superior to that in the control group(P<0.01).(4)The total incidence of adverse reactions in the observation group was 6.98%(3/43)and that in the control group was 11.63%(5/43),and the difference between the two groups was not significant(P>0.05).Conclusion Bushen Tiaojing Decoction combined with human recombinant interferon-α-2b has a significant clinical effect for the treatment of EMs patients with kidney deficiency and blood stasis syndrome.The combined therapy is effective on improving the levels of humoral immune factors,serum CA125 and EMAb,and reducing endometrial ectopic mass,with high safety.
7.Development of biological safety protection third-level laboratory based on folding-modular shelters
Si-Qing ZHAO ; Jian-Qiao XIA ; Zhong-Jie SUN ; Kang OUYANG ; Xiao-Jun JIN ; Kang-Li ZHOU ; Wei XIE ; Hai-Yang LI ; Da-Peng JIANG ; Yan-Yan GAO ; Bei SUN
Chinese Medical Equipment Journal 2024;45(3):41-46
Objective To develop a biological safety protection third-level(BSL-3)laboratory based on folding-modular shelters to solve the problems of the existing laboratories in space and function expansion,large-scale deployment and low-cost transportation.Methods The BSL-3 laboratory was composed of a folding combined shelter module,a ventilation and purification module,a power supply and distribution module,a monitoring and communication module,a control system module and an equipment module.The folding combined shelter module used a leveling base frame as the foundation and a lightweight panel as the enclosure mechanism,and was divided into an auxiliary area and a protection protected area;the ventilation and purification module was made up of an air supply unit and an air exhaust unit,the air supply unit was integrated with a fresh-air air conditioner and the exhaust unit was equipped with a main fan,a standby fan and a bag in/bag out filter;the control system module adopted a supervision mode of decentralized control and centralized management,which executed communication with the data server as the center and Profinet protocol and MODBUS-TCP.Results The BSL-3 laboratory proved to meet the requirements of relevant standards in internal microenvironment,airflow direction,airtightness,working condition and disinfection effect.Conclusion The BSL-3 laboratory is compatible with large-scale transport and deployment and facilitates reliable and safe experiments for epidemic prevention and control and cross-regional support.[Chinese Medical Equipment Journal,2024,45(3):41-46]
8.Endophytic fungi from Scutellaria baicalensis and the enzyme inhibitory activities of their secondary metabolites
De-Min LI ; Xiao-Di MA ; Kang-Xu WANG ; Mei-Yuan LI ; Man-Ping LUO ; Ying-Ying MENG ; Ai-Mei YANG ; Bei WANG ; Xin-Guo ZHANG
Chinese Traditional Patent Medicine 2024;46(8):2644-2649
AIM To study endophytic fungi from Scutellaria baicalensis Georgi.and the enzyme inhibitory activities of their secondary metabolites.METHODS Six different media were used to isolate and purify endophytic fungi from S.baicalensis by tissue homogenate method.The activities of secondary metabolites were evaluated by targeting different enzymes.The highly active strains were identified by molecular biology combined with morphology,and the highly active chemical components were tracked and separated by modern chromatographic separation technology.RESULTS Sixty-four endophytic fungal strains were isolated from S.baicalensis,and one hundred and twenty-eight secondary metabolites were obtained by fermentation.The samples with certain inhibitory activities against adenosine deaminase(ADA),β-lactamase and tyrosinase(TYR)accounted for 14.06%,3.91%and 18.75%,respectively.Strain HTS-23-2 showed high TYR inhibitory activity,and 99%homology with Aspergillus flavus by molecular identification.One compound was isolated from the fermentation samples and identified as kojic acid.CONCLUSION S.baicalensis harbors a rich diversity of endophytic fungi,which serve as a valuable resource for active substances.
9.Staged surgery of Sanders type Ⅳ calcaneal fractures with soft tissue three-degree swelling.
Zhi-Qiang YAN ; Xu-Hong XIE ; Kang-Sheng YANG ; Qiang LIU ; Bei LI ; Jun XIAO ; Guang-Peng OU
China Journal of Orthopaedics and Traumatology 2021;34(8):773-779
OBJECTIVE:
To compare the clinical efficacy of staged surgery on Sanders Ⅳ calcaneal fractures with soft tissue Ⅲ swelling.
METHODS:
The clinical data of 76 patients with Sanders type Ⅳ closed calcaneal fracture with soft tissue three-degree swelling treated from June 2017 to May 2020 was retrospectively analyzed, including 54 males and 22 females, aged from 25 to 50 (38.16±10.24) years. The patients were divided into observation group and control group according to different treatment methods. Twenty-four patients in the observation group were treated by staged surgery stageⅠclosed prying traction reduction and Kirschner wire fixation, stageⅡopen reduction and internal fixation with titanium plate, including 17 males and 7 females, aged from 25 to 50 (36.12±9.56) years. There were 52 patients in the control group, including 37 males and 15 females, aged from 25 to 50 (38.32±10.67) years, these patients were treated with open reduction and internal fixation with titanium plate after the dermatoglyphic signs appeared. The swelling subsidence time, the length of hospitalization days, and the incidence of postoperative incision complications were compared between two groups. The Bhler angle, Gissane angle, and calcaneal varus angle were measured by X-ray before and 6 months after operation. American Orthopedic Foot and Ankle Society (AOFAS) about the ankle hindfoot score was used to evaluate the clinical efficacy.
RESULTS:
All 76 patients were followed up for 8 to 12 (9.52±2.01) months. The swelling subsidence time and hospitalization days in observation group were (12.12± 3.24) d and (24.53±6.44) d, respectively, which in control group were (15.16±4.16) d and (29.46±9.61) d, with statistical difference between two groups (
CONCLUSION
Compared with open reduction and internal fixation with titanium plate after the appearance of dermatoglyphic signs, staged surgery for Sanders type Ⅳ calcaneal fractures with soft tissue three-swelling does not increase the risk of soft tissue complications, and can significantly shorten the patient's swelling subsidence time and hospitalization days, improve the quality of fracture reduction and short term function, and relieve pain.
Ankle Injuries
;
Calcaneus/surgery*
;
Female
;
Foot Injuries
;
Fractures, Bone/surgery*
;
Humans
;
Male
;
Retrospective Studies
10.Epidemiological characteristics of respiratory syncytial virus in hospitalized children with acute lower respiratory tract infection in Chongqing, China, from 2013 to 2018: an analysis of 2 066 cases.
Kang-Yi REN ; Luo REN ; Yu DENG ; Xiao-Hong XIE ; Na ZANG ; Jun XIE ; Zheng-Xiu LUO ; Jian LUO ; Zhou FU ; EnMei LIU ; Qu-Bei LI
Chinese Journal of Contemporary Pediatrics 2021;23(1):67-73
OBJECTIVE:
To study the detection rate, epidemic pattern, and clinical features of respiratory syncytial virus (RSV) in hospitalized children with acute lower respiratory infection (ALRI).
METHODS:
Nasopharyngeal aspirates were collected from children with ALRI, aged < 2 years, who were hospitalized in Children's Hospital of Chongqing Medical University from June 2013 to May 2018. Multiplex PCR was used to detect 16 common respiratory viruses. The epidemiological characteristics of RSV were analyzed.
RESULTS:
A total of 2 066 hospitalized children with ALRI were enrolled. Among the children, 1 595 (77.20%) tested positive for virus and 826 (39.98%) tested positive for RSV [410(49.6%) positive for RSV-A, 414 (50.1%) positive for RSV-B, and 2 (0.2%) positive for both RSV-A and RSV-B]. RSV-B was the main subtype detected in 2013-2014 and 2016-2017, while RSV-A was the main subtype in 2014-2015 and 2017-2018, and these two subtypes were prevalent in 2015-2016. The highest detection rate of RSV was noted in winter. RSV + human rhinovirus was the most common combination of viruses and was detected in 123 children. These children were more likely to develop wheezing than those with single RSV detected (
CONCLUSIONS
In Chongqing in 2013-2018, RSV-A and RSV-B not only can predominate alternately, but also can co-circulate during a season. RSV is the major viral pathogen of hospitalized children with ALRI and can cause severe lower respiratory tract infection. There are no differences in clinical manifestations between children with RSV-A infection and those with RSV-B infection, but boys are more susceptible to RSV-A infection.
Child
;
Child, Hospitalized
;
Child, Preschool
;
China/epidemiology*
;
Female
;
Humans
;
Infant
;
Male
;
Respiratory Syncytial Virus Infections/epidemiology*
;
Respiratory Syncytial Virus, Human
;
Respiratory Tract Infections/epidemiology*

Result Analysis
Print
Save
E-mail