1.Construction of Saikosaponin D Multifunctional Liposomes and Evaluation of Its Anti-liver Cancer Efficacy and Targeting
Kun YU ; Guochun YANG ; Yaliang JIANG ; Yunting XIAO ; Congxian WANG ; Qionge SUN ; Ziyue LI ; Yikun SHANG ; Yu MAO ; Xin CHENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(9):205-216
ObjectiveTo construct a multifunctional liposomal delivery system by replacing cholesterol(Chol) in conventional liposomes with saikosaponin D(SSD) and modifying with poloxamer 407(P407) for co-delivery of curcumin(Cur). The system was evaluated for in vivo tumor targeting and inhibitory effects on mouse subcutaneous solid tumors. MethodsSingle-factor and orthogonal tests combined with information entropy weighting were used to optimize the formulation process of the liposome with encapsulation efficiency and absolute Zeta potential as indexes, and validation studies and liposomal characterization were performed. A subcutaneous solid tumor model was established by injecting H22 hepatocellular carcinoma cells subcutaneously into the dorsal surface of the right forelimb of mice. DiR-loaded traditional Chol liposomes(P407-DiR-Chol-LPs, PDCL) and novel SSD-based liposomes(P407-DiR-SSD-LPs, PDSL) were prepared by the optimized formulation process, and tail vein injection was performed to investigate the impact of SSD on liposome tumor targeting with small animal in vivo imaging. Mice were randomly divided into eight groups, including blank group, model group, free doxorubicin(DOX) group(2 mg·kg-1), free Cur group(8 mg·kg-1), free SSD group(10 mg·kg-1), P407-Cur-Chol-LPs(PCCL) group, P407-SSD-LPs(PSL) group, and P407-Cur-SSD-Lps(PCSL) group. Treatments were administered intraperitoneally every other day for seven doses. Antitumor efficacy and biocompatibility were evaluated by monitoring body weight change, organ indices, tumor volume and mass, relative tumor proliferation rate(T/C), and tumor growth inhibition rate(TGI). Histopathological analysis of liver, kidney, and tumor tissues was performed using hematoxylin-eosin(HE) staining. Serum levels of aspartate aminotransferase(AST), alanine aminotransferase (ALT), blood urea nitrogen(BUN), and creatinine(Crea)in mice were quantified by fully automated biochemical analyzer. ResultsOrthogonal test yielded optimal ratios of Cur, SSD, and P407 to soybean phosphatidylcholine(SPC) as 1∶25, 1∶20, and 1∶4. The optimized PCSL exhibited spherical morphology with a particle size of 179.15 nm, a Zeta potential of -47.25 mV, and an encapsulation efficiency of 96.40%. Its in vitro release profile conformed to first-order kinetics, demonstrating excellent storage stability and hemocompatibility. In vivo imaging revealed that the fluorescence signal in tumor tissues and the fluorescence intensity ratio between tumors and organs were significantly higher in the PDSL group than in the PDCL group(P<0.05, P<0.01). Among the treatment groups, PCSL group showed superior efficacy over free Cur group, free SSD group, PCCL group, and PSL group, with TGI>40% and T/C<60%, indicating pronounced anti-hepatocellular carcinoma effects(P<0.05, P<0.01). Histopathology and serum biochemistry indicated minimal hepatorenal toxicity and improved hepatic and renal function in PCSL-treated mice. ConclusionReplacing Chol with SSD in preparing multifunctional drug delivery systems not only stabilizes liposomes but also yields superior anti-hepatocellular carcinoma efficacy, achieving the effect of drug-excipient integration. Co-delivery of Cur via this system can be used for treating subcutaneous solid tumors in hepatocellular carcinoma, providing new insights and technical approaches for anti-hepatocellular carcinoma research and the meridian-guiding and messenger-directing theory in traditional Chinese medicine.
2.Temporal trends of physical fitness indicators and the relationship to body mass index among college students
TANG Hanchenye,XIAO Kunpeng,WANG Qingran,SHANG Yao,KANG Yiting,WANG Huiling,LIU Changjiang
Chinese Journal of School Health 2026;47(8):1166-1169
Objective:
To explore the temporal variation in physical health status among college students, analyze the correlation and dose response relationship between body mass index (BMI) and physical fitness indicators, so as to provide a scientific basis for physical health intervention among college students in universities.
Methods:
A total of 4 910 freshmen in the 2021 grade at Xi an Jiaotong University were selected. The BMI and changes in five physical fitness indicators (50 meter run, endurance run, standing long jump, sit and reach, and pull up or 1 minute sit up) were continuously assessed during follow up evaluations from 2021 to 2024. One way analysis of variance, generalized estimating equation (GEE), and other statistical methods were used to analyze the trends in temporal variation among the physical fitness indicators as well as the correlation characteristics and dose response relationship between BMI and physical fitness.
Results:
In 2021 the overweight and obesity rates among male freshmen were 20.36 % and 8.62%, respectively, and 12.91% and 2.91% among female freshman, respectively. From 2021 to 2024 the BMI of male and female students showed an upward trend with a significant increase( F =87.29,3.69,both P <0.05). The physical fitness indicators for both male and female students, including the 50 meter run, standing long jump, pull up and 1 minute sit up, first increased and then decreased, the endurance run performance decreased, and the sit and reach performance first decreased and then increased. The GEE model showed that BMI was negatively correlated with the performance of standing long jump, pullup/1 minute sit up, and sit and reach in both male and female students( β =-1.72,-0.34,-0.15;-0.94,-0.26,-0.12), and positively correlated with the time of 50 meter run and endurance run( β =0.05,3.16;0.03,1.86)(all P <0.05). The increase in BMI was associated with physical fitness decline in a non linear dose response relationship, while the sit and reach performance reached a peak at a BMI of approximately 22 kg/m 2, then decreased with the further increase in BMI.
Conclusions
A significant negative correlation is demonstrated between BMI and physical fitness indicators and male students are more sensitive to changes in BMI. College students should be guided to actively manage their weight and attach importance to physical exercise to improve their physical health.
3.Development and application of an auxiliary device based on embedded microcontroller system for venipuncture
Jing YANG ; Jun JI ; Xiujun CHEN ; Zhihan SHANG ; Wenhui ZHAI ; Ning WANG ; Xiao ZHANG ; Rong ZHANG
China Medical Equipment 2025;22(10):159-162
Objective:To design an auxiliary device based on embedded microcontroller system for venipuncture,which can adjust posture,so as to resolve the problem that occurs failure in puncture due to insufficient exposure of the puncture site in various scenarios.Methods:The device consisted of a support component,an air ring,a component with lifting and angle adjustment,and a pedestal.By advanced embedded microcontroller technique,it can precisely regulate the posture of the support structure of patient's limbs,and fully expose the targeted puncture site,and create more favorable conditions for nurses in performing punctures.A total of 2,482 patients who underwent blood collection at emergency department of the 305th Hospital of the People's Liberation Army from September to October 2024 were selected.The 1,204 patients were enrolled in September were divided into control group(without using the auxiliary device for venipuncture),and the 1,278 patients were enrolled in October were divided into observation group(using the auxiliary device for venipuncture).The puncture's one-time success rates of junior nurses(experience≤3 years)for both groups were compared.Each group respectively selected 150 patients by using the random number table method to conduct investigate,and satisfaction scores for success rate of puncture,and comfort degree of puncture for position,as well as the pain,process and efficiency,were investigated Results:The puncture's one-time success rates of junior nurses for the patients of control and observation groups were respectively 85.05%and 89.36%,with a statistically significant difference(x2=10.35,P<0.05).The satisfaction scores of patients in the observation group were significantly higher than those in the control group,with a statistically significant difference(t=-5.529,P<0.05).Conclusion:This device is simple and convenient in operation,and has favorable stability.It is beneficial to adjust position and exposure puncture site for patients who undergo peripheral venipuncture.It can improve puncture's success rate and patients'satisfaction.
4.Optimization of the Extraction Process of Changyan Heji Ⅱ Based on UPLC-Q-TOF-MS/MS Combined with Response Surface Method and Principal Component Analysis
Shulin WANG ; Jing SHANG ; Wenjun LIU ; Zerong CAI ; Mengyu QIAN ; Xiaoxin HU ; Liang CAO ; Zhenz-hong WANG ; Wei XIAO
Journal of Nanjing University of Traditional Chinese Medicine 2025;41(4):501-512
OBJECTIVE To establish a extraction process of Changyan Heji Ⅱ(CYHJ-Ⅱ)based on UPLC-Q-TOF-MS/MS technology combined with response surface analysis,and to optimize the extraction process.METHODS The chemical components in CYHJ-Ⅱ were qualitatively analyzed by UPLC-Q-TOF-MS/MS technology,and the chemical components with good linear relation-ship in mass spectrometry response were selected as process investigation indicators;the extraction process parameters(water addition amount,extraction time and soaking time)were investigated by Box-Behnken design;the comprehensive score was obtained by princi-pal component analysis(PCA),and the optimal process was determined by the comprehensive score combined with response surface a-nalysis.RESULTS Through qualitative analysis,110 components were inferred and identified from CYHJ-Ⅱ,including 2 organic acids,82 flavonoids,13 terpenoids,and 13 alkaloids.Based on the results of qualitative analysis,48 index components with good lin-ear relationships were derived by UPLC-Q-TOF-MS/MS combined with Masshunter mass spectrometry data analysis software.PCA was performed and the comprehensive score was calculated.Response surface analysis was performed with the comprehensive score as an indicator.The optimal extraction process obtained by combining the response surface prediction results and actual production was:soaking for 45 min,8 times the amount of solvent,2 extractions,each time for 120 min.CONCLUSION This study provides a new idea for the investigation of the extraction process of traditional Chinese medicine compound prescriptions and expands a new method for the development of traditional Chinese medicine compound prescriptions.
5.The evolution of ventricular assist devices and future perspectives
Sheng-hua LI ; Mei LIU ; Han-luo LI ; Ya-lan LEI ; Xiao-ke SHANG
Chinese Journal of Interventional Cardiology 2025;33(3):170-175
Ventricular assist devices(VADs)have emerged as a pivotal therapeutic option for end-stage heart failure,undergoing significant technological advancements from pneumatic membrane pumps to continuous-flow centrifugal pumps.This review provides a detailed overview of several VAD models,including HeartMate Ⅲ,EVAHEART 2,and Heart Con.The initial generation of VADs established a foundation for subsequent developments,despite the occurrence of frequent complications.The second generation of VADs demonstrated a notable improvement in patient prognosis but carried the risk of ventricular collapse.The third generation of VADs represents a further reduction in size,incorporating magnetic levitation technology to enhance durability and blood compatibility.In the future,the development of VADs will focus on better emulating the physiological function of the native heart,improving pulsatility,and extending device longevity.As technology advances,VADs are expected to offer heart failure patients with a greater range of treatment options and a higher quality of life.
6.Development and application of a risk management system for complications of peripheral intravenous indwelling needle
Shan JIANG ; Caixia GUO ; Lihua GUO ; Yuanyuan ZHAO ; Meng XIAO ; Yiling YANG ; Chunyan WEI ; Shuo LI ; Dianyuan LIU ; Zhili SHANG
Chinese Journal of Nursing 2025;60(8):908-913
Objective To develop a risk management system for complications associated with peripheral venous indwelling needles and to evaluate its application effect in order to reduce the risk of related complications.Methods We designed a comprehensive risk management system for peripheral intravenous indwelling needle complications,integrating specialized evidence-based guidelines with clinical practice insights,including 5 modules:intelligent assessment and decision support,intelligent inspection reminders,educational modules,collaborative case management procedures,and a knowledge base.Patients admitted to the neurology and internal classification metabolism departments of a tertiary hospital in Jilin Province were conveniently selected as the research subjects.Patients were assigned to a control group(from May to July 2022,before the implementation of the system)and an experimental group(from September to December 2022,after the implementation of the system).The incidence of complications,duration of indwelling needle,compliance rate of core indicators for nursing quality and number of nursing consultations were compared between the groups.Additionally,a self-administered questionnaire was used to assess clinical nurses'evaluations of the system.Results A total of 189 patients were included in the experimental group and 177 patients in the control group.The incidence of complications associated with peripheral intravenous indwelling needles was lower than that in the control group.The duration of indwelling peripheral intravenous needles was longer than that in the control group.The quality compliance rate of peripheral venous indwelling needle care in the experimental group was higher than that in the control group,and the number of consultation cases in the experimental group was higher than that in the control group.Comparisons between the 2 groups showed statistically significant differences for all indicators(P<0.05).The nurses'recognition rates for the system's user-friendliness,professional guidance,and patient benefit were 77.78%,81.74%,and 82.13%,respectively.Conclusion The application of a peripheral vein indwelling needle complication risk management system can reduce the incidence of complications,prolong the duration of indwelling,and improve nursing quality.Nurses have a high recognition of this system.
7.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]
8.Optimization of the Extraction Process of Changyan Heji Ⅱ Based on UPLC-Q-TOF-MS/MS Combined with Response Surface Method and Principal Component Analysis
Shulin WANG ; Jing SHANG ; Wenjun LIU ; Zerong CAI ; Mengyu QIAN ; Xiaoxin HU ; Liang CAO ; Zhenz-hong WANG ; Wei XIAO
Journal of Nanjing University of Traditional Chinese Medicine 2025;41(4):501-512
OBJECTIVE To establish a extraction process of Changyan Heji Ⅱ(CYHJ-Ⅱ)based on UPLC-Q-TOF-MS/MS technology combined with response surface analysis,and to optimize the extraction process.METHODS The chemical components in CYHJ-Ⅱ were qualitatively analyzed by UPLC-Q-TOF-MS/MS technology,and the chemical components with good linear relation-ship in mass spectrometry response were selected as process investigation indicators;the extraction process parameters(water addition amount,extraction time and soaking time)were investigated by Box-Behnken design;the comprehensive score was obtained by princi-pal component analysis(PCA),and the optimal process was determined by the comprehensive score combined with response surface a-nalysis.RESULTS Through qualitative analysis,110 components were inferred and identified from CYHJ-Ⅱ,including 2 organic acids,82 flavonoids,13 terpenoids,and 13 alkaloids.Based on the results of qualitative analysis,48 index components with good lin-ear relationships were derived by UPLC-Q-TOF-MS/MS combined with Masshunter mass spectrometry data analysis software.PCA was performed and the comprehensive score was calculated.Response surface analysis was performed with the comprehensive score as an indicator.The optimal extraction process obtained by combining the response surface prediction results and actual production was:soaking for 45 min,8 times the amount of solvent,2 extractions,each time for 120 min.CONCLUSION This study provides a new idea for the investigation of the extraction process of traditional Chinese medicine compound prescriptions and expands a new method for the development of traditional Chinese medicine compound prescriptions.
9.The evolution of ventricular assist devices and future perspectives
Sheng-hua LI ; Mei LIU ; Han-luo LI ; Ya-lan LEI ; Xiao-ke SHANG
Chinese Journal of Interventional Cardiology 2025;33(3):170-175
Ventricular assist devices(VADs)have emerged as a pivotal therapeutic option for end-stage heart failure,undergoing significant technological advancements from pneumatic membrane pumps to continuous-flow centrifugal pumps.This review provides a detailed overview of several VAD models,including HeartMate Ⅲ,EVAHEART 2,and Heart Con.The initial generation of VADs established a foundation for subsequent developments,despite the occurrence of frequent complications.The second generation of VADs demonstrated a notable improvement in patient prognosis but carried the risk of ventricular collapse.The third generation of VADs represents a further reduction in size,incorporating magnetic levitation technology to enhance durability and blood compatibility.In the future,the development of VADs will focus on better emulating the physiological function of the native heart,improving pulsatility,and extending device longevity.As technology advances,VADs are expected to offer heart failure patients with a greater range of treatment options and a higher quality of life.
10.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]


Result Analysis
Print
Save
E-mail