1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Mechanism of G9a histone methyltransferase inhibitor BIX01294 inhibiting the proliferation of vascular smooth muscle cell
Ze-lan WANG ; Wen-jian LUO ; Jun-yong ZHAO ; Xiao-lin LUO ; Zhe-xue QIN
Journal of Regional Anatomy and Operative Surgery 2025;34(4):279-283
Objective To investigate the effect of G9a histone methyltransferase inhibitor BIX01294 on the proliferation of vascular smooth muscle cell(VSMC)and its underlying mechanism.Methods Twelve SD rats were divided into the control group and the treatment group,with 6 rats in each group.The rats were anesthetized by intraperitoneal injection with sodium pentobarbital,then exposed the common carotid artery and the internal and external carotid artery after disinfection and skin preparation,ligated the distal end of the internal and external jugular veins,clamped the proximal end of the common carotid artery,cut the external carotid artery,inserted the balloon catheter,blocked the blood flow by compression,and ligated the proximal end of the external carotid artery after withdrawing the balloon.The common carotid artery clamping state of rats in the treatment group was maintained after withdrawing the balloon,then restored the blood flow after perfusion with 100 μmol/L BIX01294 solution for 30 seconds;rats in the control group were restored the blood flow after perfusion with PBS for 30 seconds.VSMC were divided into the normal group and the BIX01294 groups.Cells in the normal group were cultured in low glucose medium containing 2%fetal bovine serum,and cells in the BIX01294 groups were co-treated with 2.5,5.0,7.5 and 10.0 μmol/L BIX01294 on the basis of the normal group,respectively.CCK-8 assay and EDU assay were used to detect the cell activity and proliferative ability respectively,to screen appropriate concentration of BIX01294.The cell apoptosis was detected by TUNEL assay between the normal group and the BIX01294 group,and the control group and the treatment group.Western blot was used to detect the expression levels of autophagy-and apoptosis-related proteins in the normal group and BIX01294 group.Results Compared with 0 μmol/L,the activity and proliferative ability of VSMC decreased in a concentration-dependent manner after treatment with BIX01294 at different concentrations(P<0.05).Compared with the normal group,the apoptosis level of VSMC in the BIX01294 group was increased(P<0.05),the expression of VSMC autophagy-and apoptosis-related proteins of LC3Ⅰ/Ⅱ and Bax were up-regulated(P<0.05),and the expression of Bcl-2 and p62 proteins were down-regulated(P<0.05).In vivo test results showed that BIX01294 local perfusion aggravated the apoptosis of carotid VSMC.Conclusion BIX01294 activates VSMC autophagy and apoptosis and inhibits its proliferation.
3.GBP3 negatively regulates HTLV-1 replication in a GTPase-dependent manner
Yanzi LIU ; Xin ZHAO ; Xiao QIN ; Yulu HUANG ; Xi YANG ; Qingqing FAN ; Bo YANG ; Jie WANG
Chinese Journal of Immunology 2025;41(3):535-539
Objective:To investigate the effect of GBP3 on replication of adult T-lymphocytic leukemia virus type 1(HTLV-1).Methods:Expression of GBP3 in HTLV-1-infected HeLa cell and THP1 cell was detected by Western blot.The knock-down efficiency of siRNAs targeting GBP3 in HeLa and THP1 cells was evaluated by Western blot.Effects of GBP3 overexpression or knockdown on expression of HTLV-1 proviral transcripts Tax,px,HBZ,Gag,ENV,5'UTR,and viral proteins Tax,p19 were investigated by RT-qPCR and Western blot.GTPase-defective mutant of GBP3,GBP3K51A was constructed to explore whether the effects of GBP3 on HTLV-1 infection were dependent on its GTPase activity.Results:GBP3 expression was upregulated in HTLV-1 infected HeLa and THP1 cells.GBP3 overexpression decreased expression of HTLV-1 proviral transcripts and viral proteins,whereas the knockdown of GBP3 has the opposite effects.Overexpression of GBP3K51A increased expression of HTLV-1 proviral transcripts and viral proteins.Conclusion:HTLV-1 virus infection can induce expression of GBP3;overexpression of GBP3 inhibits virus replication and may depend on GTPase.
4.Study on the Genotoxicity of Graphene Artificial Nerve Sheath Conduit
Ling-xiao SUN ; Bing-bing SUN ; Yue QIN ; Guo-wei WANG ; Luan-luan WANG ; Zi-yi YANG ; Zi-ye WANG ; Xiao-tian ZHAO ; Xiao-jing LI ; Cheng-hu LIU
Progress in Modern Biomedicine 2025;25(14):2250-2258
Objective:The genotoxicity risk of graphene artificial nerve sheath conduit was systematically evaluated to provide scientific evidence for their clinical safety and to establish methodological references for the genotoxicity assessment of nanomaterial medical devices.Methods:The potential effects of graphene artificial nerve sheath conduit on genetic and chromosomal endpoints were analyzed by integrating bacterial reverse mutation assays,in vitro chromosome aberration assays,mouse lymphoma cell TK gene mutation tests,and mammalian erythrocyte Pig-a gene mutation assays.Results:In the bacterial reverse mutation assay,all plates showed good background growth.There was no significant difference in the average number of revertant colonies between the test group and the negative control group,with a ratio around 1.0.In the in vitro chromosome aberration assay,the chromosomal aberration rate in the test group was less than 5%,showing no significant increase compared to the negative control group.In the mouse lymphoma cell TK gene mutation assay,the mutation frequency in the test group was less than twice that of the negative control group,with no significant difference.In the mammalian erythrocyte Pig-a gene mutation assay,the mutation frequencies of erythrocytes and reticulocytes in the test group were both less than 3× 10-6,showing no significant difference compared to the negative control group.Conclusions:Graphene artificial nerve sheath conduit exhibited no detectable genotoxicity under the tested conditions,the research results can provide reference and guidance for the genotoxicity evaluation of nanomaterial medical devices.
5.Design of new type of elastic gloves for burn scar rehabilitation
Ting SHEN ; Hai-yang ZHAO ; Xiao-chun JIAO ; Bao-li CHEN ; Zhi-juan WANG ; Li-na WANG ; Xiang-yang ZHAO ; Qin ZHOU
Chinese Medical Equipment Journal 2025;46(8):118-120
Objective To design a new type of elastic gloves for burn scar rehabilitation to solve the problems of conventional elastic gloves in pressure distribution,elasticity maintenance and absorption of sweat stains.Methods The new elastic gloves was made of non-woven fabric by spandex material,which was composed of external and internal parts.The main body of the external part was used as the primary structure of the gloves,which was provided with a sealing strip,a storage bag,a drawstring,etc.The internal part consisted of a bonding sheet,an elastic band,a fiber sheet,an absorbent sponge,some breathable holes,etc.Results The new elastic gloves designed could be used for the pressure therapy for the scars on the opisthenar,palm side,finger web and purlicue with scar proliferation inhibitted effectively,and the breathable hole and absorbent sponge contributed to the absorption of the sweat of the patient.Conclusion The new type of elastic gloves gains advantages in elasticity,wearing comfort and effectiveness of the pressure therapy for purlicue and finger web,and can be used for the pressure therapy to inhibit proliferative scarring after burns.[Chinese Medical Equipment Journal,2025,46(8):118-120]
6.Differences of local brain activity in first-episode drug-na?ve depressive patients with and without suicidal ideation during resting-state
Hua XIAO ; Limin YAO ; Qian ZHAO ; Yangyang XU ; Shan XIE ; Hongquan LU ; Qin JIANG ; Kaitang ZHU
Journal of Practical Radiology 2025;41(7):1089-1093
Objective To analyze the differences of brain activity between first-episode untreated depressive patients with and without suicidal ideation(SI),and its correlations with clinical characteristics.Methods A total of 40 major depressive disorder(MDD)patients with SI(MDD+SI group),40 patients without SI MDD(MDD+NSI group),and 40 healthy controls(HC)(HC group)were enrolled.The 17-item Hamilton depression scale(HAMD-17)and Beck scale for suicide ideation(BSI)were used to assess the severity of depression and SI,respectively.MRI data were collected.The values of fractional amplitude of low-frequency fluctuation(fALFF)were calculated.Results(1)Compared with the HC group,the MDD+NSI group showed decreases in the fALFF val-ues of the default network and attention network.The fALFF values of the attention network in the MDD+SI group showed decreases.Compared with the MDD+NSI group,the MDD+SI group showed decreases in the fALFF values of the attention network.(2)The fALFF values in the left middle frontal gyrus were negatively correlated with the total score of HAMD-17(r=-0.55;P<0.001)in the MDD+NSI group,while the fALFF values in the left middle frontal gyrus were negatively correlated with the total score of HAMD-17(r=-0.53;P<0.001)and the total score of BSI(r=-0.51;P<0.001)in the MDD+SI group.(3)The optimal critical value of fALFF value in left middle frontal gyrus for predicting SI occurrence in MDD patients was-0.039,area under the curve(AUC)was 0.76,sensitivity was 0.63,and specificity was 0.80.Conclusion The decreased local activity intensity in the left middle frontal gyrus of the brain might be the central mechanism for the occurrence of SI in MDD patients.In addition,the left middle frontal gyrus might have certain value in identifying SI and predicting the severity of SI.
7.Differences of local brain activity in first-episode drug-na?ve depressive patients with and without suicidal ideation during resting-state
Hua XIAO ; Limin YAO ; Qian ZHAO ; Yangyang XU ; Shan XIE ; Hongquan LU ; Qin JIANG ; Kaitang ZHU
Journal of Practical Radiology 2025;41(7):1089-1093
Objective To analyze the differences of brain activity between first-episode untreated depressive patients with and without suicidal ideation(SI),and its correlations with clinical characteristics.Methods A total of 40 major depressive disorder(MDD)patients with SI(MDD+SI group),40 patients without SI MDD(MDD+NSI group),and 40 healthy controls(HC)(HC group)were enrolled.The 17-item Hamilton depression scale(HAMD-17)and Beck scale for suicide ideation(BSI)were used to assess the severity of depression and SI,respectively.MRI data were collected.The values of fractional amplitude of low-frequency fluctuation(fALFF)were calculated.Results(1)Compared with the HC group,the MDD+NSI group showed decreases in the fALFF val-ues of the default network and attention network.The fALFF values of the attention network in the MDD+SI group showed decreases.Compared with the MDD+NSI group,the MDD+SI group showed decreases in the fALFF values of the attention network.(2)The fALFF values in the left middle frontal gyrus were negatively correlated with the total score of HAMD-17(r=-0.55;P<0.001)in the MDD+NSI group,while the fALFF values in the left middle frontal gyrus were negatively correlated with the total score of HAMD-17(r=-0.53;P<0.001)and the total score of BSI(r=-0.51;P<0.001)in the MDD+SI group.(3)The optimal critical value of fALFF value in left middle frontal gyrus for predicting SI occurrence in MDD patients was-0.039,area under the curve(AUC)was 0.76,sensitivity was 0.63,and specificity was 0.80.Conclusion The decreased local activity intensity in the left middle frontal gyrus of the brain might be the central mechanism for the occurrence of SI in MDD patients.In addition,the left middle frontal gyrus might have certain value in identifying SI and predicting the severity of SI.
8.Atomic force microscopic observation of surface structure of purified protein molecules in vitro
Zhao-ying CHEN ; Xiao-feng FANG ; Dan-yan LIU ; Meng-qin CHEN ; Xi LING ; Jie-min ZHAO ; Wei WEI ; Yu-jing WU
Chinese Pharmacological Bulletin 2025;41(1):193-199
Aim To compare the observation results of atomic force microscopy(AFM)and scanning electron microscopy(SEM),and to summarize the main problems and solutions of AFM in observing biological macromolecules,using the observa-tion subjects of protein samples purified by our research group.Methods The protein samples were diluted to 15 nmol·L-1 with PBS,fixed on glass slides,silicon wafers,and mica sheets,dried,and made into solid-phase observation samples.SEM sam-ples were plated with platinum before observation.The surface structures of proteins were observed using AFM and SEM,sample heights were calculated,and differences in results were com-pared.Results Protein samples with positive charges tended to shift to the right during observation due to the repulsion of the AFM probe;mica sheets could effectively eliminate the positive charge of proteins to avoid sample movement;PBS provided a stable environment for protein samples,but the crystallization of PBS salts interfered with probe operation and imaging clarity;SEM samples needed to be plated with platinum before observa-tion and could not achieve the precision of AFM.Conclusions Both AFM and SEM can directly observe protein structures in vitro,with AFM providing higher precision results;when protein sample stability permits,ultrapure water is preferred as the sol-vent carrier,and volatile liquids such as ethanol can also serve as solvent carriers.The application of AFM offers a new approach for pharmacological studies on interactions between biological macromolecules.
9.Study on the Genotoxicity of Graphene Artificial Nerve Sheath Conduit
Ling-xiao SUN ; Bing-bing SUN ; Yue QIN ; Guo-wei WANG ; Luan-luan WANG ; Zi-yi YANG ; Zi-ye WANG ; Xiao-tian ZHAO ; Xiao-jing LI ; Cheng-hu LIU
Progress in Modern Biomedicine 2025;25(14):2250-2258
Objective:The genotoxicity risk of graphene artificial nerve sheath conduit was systematically evaluated to provide scientific evidence for their clinical safety and to establish methodological references for the genotoxicity assessment of nanomaterial medical devices.Methods:The potential effects of graphene artificial nerve sheath conduit on genetic and chromosomal endpoints were analyzed by integrating bacterial reverse mutation assays,in vitro chromosome aberration assays,mouse lymphoma cell TK gene mutation tests,and mammalian erythrocyte Pig-a gene mutation assays.Results:In the bacterial reverse mutation assay,all plates showed good background growth.There was no significant difference in the average number of revertant colonies between the test group and the negative control group,with a ratio around 1.0.In the in vitro chromosome aberration assay,the chromosomal aberration rate in the test group was less than 5%,showing no significant increase compared to the negative control group.In the mouse lymphoma cell TK gene mutation assay,the mutation frequency in the test group was less than twice that of the negative control group,with no significant difference.In the mammalian erythrocyte Pig-a gene mutation assay,the mutation frequencies of erythrocytes and reticulocytes in the test group were both less than 3× 10-6,showing no significant difference compared to the negative control group.Conclusions:Graphene artificial nerve sheath conduit exhibited no detectable genotoxicity under the tested conditions,the research results can provide reference and guidance for the genotoxicity evaluation of nanomaterial medical devices.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail