1.The construction and evaluation of heart preservation model for empty beating donor heart based on extracorporeal membrane oxygenation technology
Shijie YIN ; Xiao YUE ; Chunhua WANG ; Wei WU ; Guanbin QIN ; Lan LUO ; Qiangxin HUANG ; Guixin HE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):791-798
Objective To explore the construction of heart preservation model of empty beating donor based on extracorporeal membrane oxygenation (ECMO). Methods From January 2022 to August 2023, 20 Guangxi Bama miniature pigs weighing 25-30 kg were selected, half male and half female. Under general anesthesia and heparinization, a midline thoracotomy was performed. The pericardium was cut after freeing the anterior and posterior vena cavae, and a perfusion needle was inserted near the brachiocephalic artery in the ascending aorta, connected to a blood collection bag to collect 500-600 mL of blood. The anterior and posterior vena cavae were ligated, the aorta was blocked and perfused with HTK solution to stop the heart beating. The superior and inferior vena cavae were cut off, the right pulmonary vein was decompressed, the aorta and left and right pulmonary arteries and veins were cut off, and the whole heart was removed. An ECMO device was used to continuously perfuse a cardioprotective solution mainly composed of oxygenated warm blood, maintaining the isolated pig heart beating for 8 hours, monitoring (once/hour) ECMO perfusion parameters, blood gas indicators, perfusate electrolytes, inflammatory factors, myocardial enzymes, myoglobin, and troponin levels. Myocardial tissue was taken for hematoxylin-eosin (HE) staining to observe myocardial cell damage and evaluate the quality of heart preservation. Results Among the 20 isolated beating pig hearts, 17 successfully resumed beating, 3 experienced ventricular fibrillation, resuscitated after intracardiac electrical defibrillation, and all 20 pig hearts successfully beat for 8 hours. There was no statistical difference in ECMO perfusion parameters, blood gas indicators, perfusate electrolytes, and inflammatory factors at each time point (P>0.05). There were statistical increases in myocardial enzymes, myoglobin, and troponin levels (P<0.05). HE staining results suggested that there was no severe myocardial damage. Conclusion ECMO technology can be used for pig heart preservation with good results, and this study provides experimental evidence for improving heart preservation research in clinical heart transplantation.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Development and clinical diagnostic efficacy of a novel LAMP method tar-geting the tcdC gene in Clostridioides difficile
Yuanyuan XIAO ; Juping DUAN ; Jingxiang ZHOU ; Qin HUANG ; Yan QING ; Haibo WANG ; Anhua WU ; Chunhui LI
Chinese Journal of Infection Control 2025;24(4):451-459
Objective To develop a method for rapidly identifying Clostridioides difficile(C.difficile)and de-termining high-producing toxin strains,conduct clinical evaluation.Methods The loop-mediated isothermal amplifi-cation(LAMP)method was used to identify C.difficile based on the tcdC,tcdA,and tcdB genes.The sensitivi-ty,specificity,and overall consistency of the detection method were evaluated.Results Feces specimens from 499 hospitalized patients suspected of C.difficile-associated diarrhea were detected,with C.difficile detection rate of 12.8%(64/499),out of which the detection rate of toxin-producing C.difficile was 10.8%(54/499).The sensi-tivity,specificity,positive predictive value,and negative predictive value of the detection method for tcdA were 87.2%,98.9%,89.1%,and 98.6%,respectively,and 88.2%,99.6%,90.0%,and 98.73%for tcdB,respec-tively.The total toxin levels of different strains were different,but the average toxin production level of A+B+strains(1.79 μg/mL)was higher than those of A-B+strains(0.72 μg/mL)and A-B-strains(<0.10 μg/mL).Conclusion The portable high-throughput LAMP detection method can rapidly and efficiently identify C.difficile and determine high-producing toxin strains.
4.Establishment and application of a method for detecting Toxoplasma gondii based on recombinant polymerase amplification technology
Shao-zheng SONG ; Le-ying GU ; Ying-chao WU ; Ya-qin MENG ; Kang-ying YU ; Xiao-hua HUANG
Chinese Journal of Zoonoses 2025;41(2):107-112
To establish a method for detecting Toxoplasma gondii based on recombinant polymerase amplification(RPA)technology and apply it to clinical sample validation of pet cats.Using the 529 repeat sequence of the Toxoplasma gondii gene as the target gene sequence,primers and probes were designed,and the Rep-529 recombinant plasmid was constructed as the standard.A fluorescent RPA reaction system was established.Dilute the plasmid standard 10 times to different concentrations as the detection template for sensitivity testing;Specific testing was conducted using genomic DNA from several parasitic spe-cies,including Toxoplasma gondii,Cryptosporidium,Neosporidium,Trichinella spiralis,Giardia flagellata,Babesia bo-vis and Theileria annulata as templates;Simultaneously,fluorescence RPA and RT-PCR were used to detect 52 positive and 40 negative cats clinical samples,and the coincidence rate of the detection results of the two methods were compared and ana-lyzed.The RPA reaction system was successfully established using PTRep recombinant plasmid as the standard,ToxD-F/ToxD-R as the primer,and RepD-P as the fluorescent probe.The reaction temperature was constant at 39 ℃,the reaction time was 30 minutes,and the detection sensitivity was 1 copy/μL.There is no significant cross reaction with parasites such as Cryptosporidium,Neosporidium,Trichinella spiralis,Giardia,Babesia bovis and Theileria annulata,and the specificity is good.A total of 92 clinical fecal samples from cats were tested,and the positive coincidence rate of fluorescence RPA detection method was higher than that of conventional RT-PCR method(98.08%vs.82.69%),and the difference of the positive rate was not statistically significant(X2=1.392,P>0.05).The fluorescence RPA detection method for Toxoplasma gondii suc-cessfully established in this study has the characteristics of being fast,sensitive,specific,accurate,and reliable.It can be used as a rapid clinical detection kit for Toxoplasma gondii in cats and other animals,providing new technical support for the subsequent epidemiological monitoring and precise clinical diagnosis of toxoplasmosis in cats,other animals,and humans in the future.
5.GBP3 negatively regulates HTLV-1 replication in a GTPase-dependent manner
Yanzi LIU ; Xin ZHAO ; Xiao QIN ; Yulu HUANG ; Xi YANG ; Qingqing FAN ; Bo YANG ; Jie WANG
Chinese Journal of Immunology 2025;41(3):535-539
Objective:To investigate the effect of GBP3 on replication of adult T-lymphocytic leukemia virus type 1(HTLV-1).Methods:Expression of GBP3 in HTLV-1-infected HeLa cell and THP1 cell was detected by Western blot.The knock-down efficiency of siRNAs targeting GBP3 in HeLa and THP1 cells was evaluated by Western blot.Effects of GBP3 overexpression or knockdown on expression of HTLV-1 proviral transcripts Tax,px,HBZ,Gag,ENV,5'UTR,and viral proteins Tax,p19 were investigated by RT-qPCR and Western blot.GTPase-defective mutant of GBP3,GBP3K51A was constructed to explore whether the effects of GBP3 on HTLV-1 infection were dependent on its GTPase activity.Results:GBP3 expression was upregulated in HTLV-1 infected HeLa and THP1 cells.GBP3 overexpression decreased expression of HTLV-1 proviral transcripts and viral proteins,whereas the knockdown of GBP3 has the opposite effects.Overexpression of GBP3K51A increased expression of HTLV-1 proviral transcripts and viral proteins.Conclusion:HTLV-1 virus infection can induce expression of GBP3;overexpression of GBP3 inhibits virus replication and may depend on GTPase.
6.Present situation of sensors applied to monitoring of spinal morphology and motion
Shi-yu ZHOU ; Ya-qin LI ; Yang-xi HUANG ; Xiao CHEN ; Jing WANG ; Zhi-min LIANG ; Yu-chen GUO ; Xue YANG ; Ling-li LI
Chinese Medical Equipment Journal 2025;46(6):105-110
The application of sensors to the monitoring of spinal morphology and motion was reviewed in terms of the research object and monitoring index.The present situation of the application of sensors was introduced,such as inertial sensor,stretchable strain sensor and electromagnetic sensor.The deficiencies of sensors applied to the monitoring of spinal morphology and motion were analyzed,and the future directions of the application were pointed out.[Chinese Medical Equipment Journal,2025,46(6):105-110]
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Polystyrene microplastics induce oxidative stress and ferroptosis and cause myocardial damage in mice
Qi HUANG ; Deyu ZHU ; Xiao LIANG ; Jinling WU ; Wengui QIN ; Ping MA ; Yang WU ; Cuiyu BAO
Acta Universitatis Medicinalis Anhui 2025;60(6):1009-1014
Objective To investigate the effect of polystyrene microplastics(PS-MPs)on myocardial injury in mice and its molecular mechanism.Methods A total of 60 male C57BL/6 mice were randomly divided into normal sa-line group,0.1,1,10 mg/kg PS-MPs exposed group,and doxorubicin[5 mg/(kg·w)]group treated for 8 weeks.After treatment,we measured blood pressure,cardiac organ coefficient,cardiac histopathological changes,oxidative stress markers reactive oxygen species(ROS),malondialdehyde(MDA),glutathione(GSH),4-hydroxynonenal(4-HNE)and nuclear factor E2-related factor 2(Nrf2),serum centroid injury markers creatine kinase MB(CK-MB)and troponin(cTnT),ferroptosis marker recombinant glutathione peroxidase 4(GPX4),Recombinant solute carrier family 7(SLC7 A11)as well as ferrous ions(Fe2+).Results Compared with the neg-ative control group,vacuolation,inflammatory infiltration and collagen fiber deposition were evident in the hearts of mice after PS exposure.The levels of myocardial injury markers CK-MB and cTnT significantly increased.Cardiac organ coefficient decreased,blood pressure increased,oxidative stress markers and ferroptosis markers increased.Conclusion PS-MPs exposure can induce oxidative stress and activate ferroptosis pathway,resulting in myocardial injury in mice.
9.Development and clinical diagnostic efficacy of a novel LAMP method tar-geting the tcdC gene in Clostridioides difficile
Yuanyuan XIAO ; Juping DUAN ; Jingxiang ZHOU ; Qin HUANG ; Yan QING ; Haibo WANG ; Anhua WU ; Chunhui LI
Chinese Journal of Infection Control 2025;24(4):451-459
Objective To develop a method for rapidly identifying Clostridioides difficile(C.difficile)and de-termining high-producing toxin strains,conduct clinical evaluation.Methods The loop-mediated isothermal amplifi-cation(LAMP)method was used to identify C.difficile based on the tcdC,tcdA,and tcdB genes.The sensitivi-ty,specificity,and overall consistency of the detection method were evaluated.Results Feces specimens from 499 hospitalized patients suspected of C.difficile-associated diarrhea were detected,with C.difficile detection rate of 12.8%(64/499),out of which the detection rate of toxin-producing C.difficile was 10.8%(54/499).The sensi-tivity,specificity,positive predictive value,and negative predictive value of the detection method for tcdA were 87.2%,98.9%,89.1%,and 98.6%,respectively,and 88.2%,99.6%,90.0%,and 98.73%for tcdB,respec-tively.The total toxin levels of different strains were different,but the average toxin production level of A+B+strains(1.79 μg/mL)was higher than those of A-B+strains(0.72 μg/mL)and A-B-strains(<0.10 μg/mL).Conclusion The portable high-throughput LAMP detection method can rapidly and efficiently identify C.difficile and determine high-producing toxin strains.
10.Evaluation of the efficacy of corticosteroids in male children with Duchenne muscular dystrophy
Jialu XU ; Qinrong HUANG ; Hongliang HUO ; Yuting ZHANG ; Xiaoyan SHEN ; Liang TAO ; Xujun CAO ; Qin GU ; Nong XIAO ; Haifeng LI
Chinese Journal of Pediatrics 2025;63(8):885-890
Objective:To evaluate the efficacy of corticosteroids in male children with Duchenne muscular dystrophy (DMD), and provide evidence for the rational clinical use of medication.Methods:This was a multicenter medical record series study which conducted from January 15 th to March 14 th, 2025. A total of 53 male children with DMD admitted to the Department of Rehabilitation of Children′s Hospital, Zhejiang University School of Medicine, Children′s Hospital of Chongqing Medical University and Affiliated Children′s Hospital of Soochow University from 2020 to 2024 were enrolled. Clinical data, corticosteroid usage, and the follow-up data were collected. The North star ambulatory assessment (NSAA) was used as the primary efficacy indicator. Generalized estimating equations (GEE) exchangeable working matrices were used for longitudinal analysis, and the least squares mean were used to compare the change trend of the efficacy evaluation index across different medication durations. Results:The age at the initiation of corticosteroid treatment was (6.3±1.9) years. The follow-up duration was 1.2 (0.9, 2.2) years. After treatment, the raw scores and linear scores of NSAA were both significantly higher than those before treatment ((22±7) vs. (19±5) points, (60±16) vs. (53±8) points; t=3.98, 3.69; both P<0.001). The 10 meter running time and time rising from floor were both shorter than those before treatment (6 (4, 8) vs. 7 (6, 9) s, 5 (3, 6) vs. 6 (5, 9) s; Z=2.62, 3.47; both P<0.01). GEE model analysis revealed all nonlinear correlation between motor function (NSAA linear score, 10-meter running velocity, and rising from floor velocity) and the duration of corticosteroid treatment (all P<0.05). Least squares mean comparison all showed that the medication effect first increased and then decreased with duration, reaching the peak at 1.1-2.0 years after treatment (all P<0.05). Conclusions:Corticosteroids can improve the motor function in male children with DMD, with the maximum treatment effect occurring 1 to 2 years after the initiation of treatment. It is necessary to comprehensively leverage time-varying efficacy of corticosteroids to optimize individualized treatment regimens for maximal motor function benefits in children with DMD.

Result Analysis
Print
Save
E-mail