1.Establishment and application of ultra-fast real-time PCR for Brucella detection
Zhen-na XU ; Zhi-peng WU ; Wei-bin HONG ; Zhi-shen GUAN ; Qi-ming LIN ; Zuan-lan MO ; Yi-fei YE ; Hai-yan XIE ; Min LI ; Yan-qiu ZHU ; Xiao-jun LI ; Xian-peng ZHANG
Chinese Journal of Zoonoses 2025;41(3):278-283
This study was aimed at establishing a method of ultra-fast quantitative PCR for Brucella detection.We used an exogenous recombinant plasmid as the internal reference and targeted the T4SS secretion system,an important Brucella viru-lence factor,to design specific primers and probes.The sensitivity,specificity,and repeatability of this method were evaluated,and a standard curve was constructed.The coincidence rate of detection findings with this method versus quantitative PCR was determined.This method markedly decreased the detection time to only 10 minutes.The standard curve demonstrated a good linear relationship(Y=-3.410 7x+38.357,R2=0.998 5)with a low minimum detection limit of 10 copies/μL.The method exhibited good specificity and did not specifically amplify several common clinical bacteria other than Brucella.The de-tection of three concentrations of positive plasmids yielded coefficients of variation(CVs)of 0.20%to 0.91%,thus demonstra-ting the method's excellent repeatability.Furthermore,140 clinical samples were analyzed concurrently with the fluorescence PCR method,which yielded a 100%compliance rate and consistent results.Our findings indicated that the Brucella ultra-fast quantitative PCR was ultrafast;had high sensitivity,high specificity,and good specificity;and can be used for the clinical de-tection of Brucella and emergency investigation of epidemics.Therefore,this method is valuable for the early diagnosis of Bru-cella.
2.Correlation between abnormal hand features and coronary atherosclerotic heart disease
Hui ZHOU ; Xiao LI ; Zhiyue GUAN ; Shuangqiu WANG ; Jianyu LI ; Qi CHEN ; Hao WANG ; Kongfa HU ; Xue XU
Journal of Beijing University of Traditional Chinese Medicine 2025;48(8):1044-1051
Objective This study aimed to explore the correlation between abnormal hand features and coronary atherosclerotic heart disease(CHD)to provide clinical data support for digitalized traditional Chinese medicine(TCM)hand diagnosis.Methods A palm key point prediction algorithm was used to automatically capture and collect detailed features of the palm and nails through image analysis and data mining using the hand diagnosis information collection technology based on the NVIDIA Jetson platform and Qt framework.A total of 438 cardiac patients who underwent coronary artery computed tomography angiography(CACTA)in the Department of Cardiology,Dongzhimen Hospital,Beijing University of Chinese Medicine,from December 2023 to April 2024 were included and divided into CHD(148 cases)and non-CHD groups(290 cases)based on the CACTA results.The hand features of the two groups were compared,and abnormal hand features associated with CHD were screened using random forest analysis as well as univariate and multivariate logistic regression analyses.Results Based on the results of univariate logistic regression and random forest analyses,a set of hand-related features associated with CHD were identified and subsequently included in the multivariate logistic regression analysis.These features included the morphology of the thenar eminence,the wrinkles of the thenar eminence,nail shape,nail texture,and the length of the blood vessel in the middle finger.Multivariate logistic regression analysis revealed that hypertrophic thenar eminence[odds ratio(OR):3.049,95%confidence interval(CI):1.430-6.503,P=0.004],presence of wrinkles on the thenar eminence(OR:2.206,95%CI:1.119-4.348,P=0.022),presence of gray-black vertical stripes on the nails(OR:1.981,95%CI:1.173-3.347,P=0.011),uneven nail surface(OR:3.130,95%CI:1.822-5.378,P<0.001),and inward-bending nail surface(OR:5.727,95%CI:1.812-18.102,P=0.003)were positively associated with CHD.In contrast,the blood vessel in the middle finger longer than 1/3 of the phalanx was negatively associated with CHD(OR:0.405,95%CI:0.234-0.702,P=0.001).Conclusion Certain hand features are significantly associated with CHD,providing the valuable clinical data to support for the digitalization of TCM hand diagnosis.
3.Establishment and application of ultra-fast real-time PCR for Brucella detection
Zhen-na XU ; Zhi-peng WU ; Wei-bin HONG ; Zhi-shen GUAN ; Qi-ming LIN ; Zuan-lan MO ; Yi-fei YE ; Hai-yan XIE ; Min LI ; Yan-qiu ZHU ; Xiao-jun LI ; Xian-peng ZHANG
Chinese Journal of Zoonoses 2025;41(3):278-283
This study was aimed at establishing a method of ultra-fast quantitative PCR for Brucella detection.We used an exogenous recombinant plasmid as the internal reference and targeted the T4SS secretion system,an important Brucella viru-lence factor,to design specific primers and probes.The sensitivity,specificity,and repeatability of this method were evaluated,and a standard curve was constructed.The coincidence rate of detection findings with this method versus quantitative PCR was determined.This method markedly decreased the detection time to only 10 minutes.The standard curve demonstrated a good linear relationship(Y=-3.410 7x+38.357,R2=0.998 5)with a low minimum detection limit of 10 copies/μL.The method exhibited good specificity and did not specifically amplify several common clinical bacteria other than Brucella.The de-tection of three concentrations of positive plasmids yielded coefficients of variation(CVs)of 0.20%to 0.91%,thus demonstra-ting the method's excellent repeatability.Furthermore,140 clinical samples were analyzed concurrently with the fluorescence PCR method,which yielded a 100%compliance rate and consistent results.Our findings indicated that the Brucella ultra-fast quantitative PCR was ultrafast;had high sensitivity,high specificity,and good specificity;and can be used for the clinical de-tection of Brucella and emergency investigation of epidemics.Therefore,this method is valuable for the early diagnosis of Bru-cella.
4.Correlation between abnormal hand features and coronary atherosclerotic heart disease
Hui ZHOU ; Xiao LI ; Zhiyue GUAN ; Shuangqiu WANG ; Jianyu LI ; Qi CHEN ; Hao WANG ; Kongfa HU ; Xue XU
Journal of Beijing University of Traditional Chinese Medicine 2025;48(8):1044-1051
Objective This study aimed to explore the correlation between abnormal hand features and coronary atherosclerotic heart disease(CHD)to provide clinical data support for digitalized traditional Chinese medicine(TCM)hand diagnosis.Methods A palm key point prediction algorithm was used to automatically capture and collect detailed features of the palm and nails through image analysis and data mining using the hand diagnosis information collection technology based on the NVIDIA Jetson platform and Qt framework.A total of 438 cardiac patients who underwent coronary artery computed tomography angiography(CACTA)in the Department of Cardiology,Dongzhimen Hospital,Beijing University of Chinese Medicine,from December 2023 to April 2024 were included and divided into CHD(148 cases)and non-CHD groups(290 cases)based on the CACTA results.The hand features of the two groups were compared,and abnormal hand features associated with CHD were screened using random forest analysis as well as univariate and multivariate logistic regression analyses.Results Based on the results of univariate logistic regression and random forest analyses,a set of hand-related features associated with CHD were identified and subsequently included in the multivariate logistic regression analysis.These features included the morphology of the thenar eminence,the wrinkles of the thenar eminence,nail shape,nail texture,and the length of the blood vessel in the middle finger.Multivariate logistic regression analysis revealed that hypertrophic thenar eminence[odds ratio(OR):3.049,95%confidence interval(CI):1.430-6.503,P=0.004],presence of wrinkles on the thenar eminence(OR:2.206,95%CI:1.119-4.348,P=0.022),presence of gray-black vertical stripes on the nails(OR:1.981,95%CI:1.173-3.347,P=0.011),uneven nail surface(OR:3.130,95%CI:1.822-5.378,P<0.001),and inward-bending nail surface(OR:5.727,95%CI:1.812-18.102,P=0.003)were positively associated with CHD.In contrast,the blood vessel in the middle finger longer than 1/3 of the phalanx was negatively associated with CHD(OR:0.405,95%CI:0.234-0.702,P=0.001).Conclusion Certain hand features are significantly associated with CHD,providing the valuable clinical data to support for the digitalization of TCM hand diagnosis.
5.Specific DNA barcodes screening, germplasm resource identification, and genetic diversity analysis of Platycodon grandiflorum
Xin WANG ; Yue SHI ; Jin-hui MAN ; Yu-ying HUANG ; Xiao-qin ZHANG ; Ke-lu AN ; Gao-jie HE ; Zi-qi LIU ; Fan-yuan GUAN ; Yu-yan ZHENG ; Xiao-hui WANG ; Sheng-li WEI
Acta Pharmaceutica Sinica 2024;59(1):243-252
Platycodonis Radix is the dry root of
6.Expert consensus on ethical requirements for artificial intelligence (AI) processing medical data.
Cong LI ; Xiao-Yan ZHANG ; Yun-Hong WU ; Xiao-Lei YANG ; Hua-Rong YU ; Hong-Bo JIN ; Ying-Bo LI ; Zhao-Hui ZHU ; Rui LIU ; Na LIU ; Yi XIE ; Lin-Li LYU ; Xin-Hong ZHU ; Hong TANG ; Hong-Fang LI ; Hong-Li LI ; Xiang-Jun ZENG ; Zai-Xing CHEN ; Xiao-Fang FAN ; Yan WANG ; Zhi-Juan WU ; Zun-Qiu WU ; Ya-Qun GUAN ; Ming-Ming XUE ; Bin LUO ; Ai-Mei WANG ; Xin-Wang YANG ; Ying YING ; Xiu-Hong YANG ; Xin-Zhong HUANG ; Ming-Fei LANG ; Shi-Min CHEN ; Huan-Huan ZHANG ; Zhong ZHANG ; Wu HUANG ; Guo-Biao XU ; Jia-Qi LIU ; Tao SONG ; Jing XIAO ; Yun-Long XIA ; You-Fei GUAN ; Liang ZHU
Acta Physiologica Sinica 2024;76(6):937-942
As artificial intelligence technology rapidly advances, its deployment within the medical sector presents substantial ethical challenges. Consequently, it becomes crucial to create a standardized, transparent, and secure framework for processing medical data. This includes setting the ethical boundaries for medical artificial intelligence and safeguarding both patient rights and data integrity. This consensus governs every facet of medical data handling through artificial intelligence, encompassing data gathering, processing, storage, transmission, utilization, and sharing. Its purpose is to ensure the management of medical data adheres to ethical standards and legal requirements, while safeguarding patient privacy and data security. Concurrently, the principles of compliance with the law, patient privacy respect, patient interest protection, and safety and reliability are underscored. Key issues such as informed consent, data usage, intellectual property protection, conflict of interest, and benefit sharing are examined in depth. The enactment of this expert consensus is intended to foster the profound integration and sustainable advancement of artificial intelligence within the medical domain, while simultaneously ensuring that artificial intelligence adheres strictly to the relevant ethical norms and legal frameworks during the processing of medical data.
Artificial Intelligence/legislation & jurisprudence*
;
Humans
;
Consensus
;
Computer Security/standards*
;
Confidentiality/ethics*
;
Informed Consent/ethics*
7.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
8.Rigid-body inverse dynamics modelling and analysis of 6RSS parallel bio-inspired masticatory robot
Chen CHENG ; Xiao-Jing YUAN ; Neng-Jun YANG ; Gen-Liang HOU ; Fan-Qi ZENG ; You-Cai WANG ; Wei-Peng LUO ; Guan ZHAO
Chinese Medical Equipment Journal 2024;45(3):16-22
Objective To carry out rigid-body inverse dynamics modelling and analysis of a self-designed 6RSS parallel bio-inspired masticatory robot.Methods Firstly,the functions of kinematic variables including translational/rotational velocities and accelerations were derived for rigid-body inverse dynamics modelling.Secondly,the rigid-body inverse dynamics model was established with the Newton-Euler's law.Finally,the chewing motion trajectories of the oral health volunteers were tracked and numerical calculations were carried out in the case where the robot was subjected to a chewing reaction force.Results Numerical calculations showed that the driving torque and the constraint force of the robot peaked when the chewing reaction force was at its maximum.Conclusion The external force has a large impact on the inverse dynamics of the robot,and theoretical references are provided for the motion control and optimal design of the robot.[Chinese Medical Equipment Journal,2024,45(3):16-22]
9.Background, design, and preliminary implementation of China prospective multicenter birth cohort
Si ZHOU ; Liping GUAN ; Hanbo ZHANG ; Wenzhi YANG ; Qiaoling GENG ; Niya ZHOU ; Wenrui ZHAO ; Jia LI ; Zhiguang ZHAO ; Xi PU ; Dan ZHENG ; Hua JIN ; Fei HOU ; Jie GAO ; Wendi WANG ; Xiaohua WANG ; Aiju LIU ; Luming SUN ; Jing YI ; Zhang MAO ; Zhixu QIU ; Shuzhen WU ; Dongqun HUANG ; Xiaohang CHEN ; Fengxiang WEI ; Lianshuai ZHENG ; Xiao YANG ; Jianguo ZHANG ; Zhongjun LI ; Qingsong LIU ; Leilei WANG ; Lijian ZHAO ; Hongbo QI
Chinese Journal of Perinatal Medicine 2024;27(9):750-755
China prospective multicenter birth cohort (Prospective Omics Health Atlas birth cohort, POHA birth cohort) study was officially launched in 2022. This study, in collaboration with 12 participating units, aims to establish a high-quality, multidimensional cohort comprising 20 000 naturally conceived families and assisted reproductive families. The study involves long-term follow-up of parents and offspring, with corresponding biological samples collected at key time points. Through multi-omics testing and analysis, the study aims to conduct multi-omics big data research across the entire maternal and infant life cycle. The goal is to identify new biomarkers for maternal and infant diseases and provide scientific evidence for risk prediction related to maternal diseases and neonatal health.
10.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.

Result Analysis
Print
Save
E-mail