1. Exploration and Practice of a Generative AI-assisted Four-dimensional Integration Platform of “Teaching, Learning, Evaluation, and Research” for The Biochemistry and Molecular Biology Courses
Pan CHEN ; Yang XI ; Xiao-Feng JIN ; De-Sen SUN ; Qiang CHEN ; Jun-Ming GUO
Progress in Biochemistry and Biophysics 2026;53(3):789-800
ObjectiveBiochemistry and Molecular Biology, a discipline that elucidates life phenomena at the molecular level, serves as a core foundational course in medical education. It provides the theoretical basis for studying other basic and clinical medical subjects, as well as for understanding pathogenesis, disease diagnosis, and treatment. However, its complex content and highly abstract concepts have posed a dual challenge to traditional teaching models: “inefficient instruction” and “inadequate learning outcomes”. Within limited classroom hours, how to engage students and stimulate their intrinsic motivation, and how to help them recognize, understand, and develop a passion for biochemistry from the perspective of the discipline’s essence, have long been key focuses of curriculum research. MethodsUsing the lipid metabolism chapter as an example, this study employs “Rain Classroom”, a generative artificial intelligence (AI)-assisted platform, to support education in four dimensions: teaching, learning, evaluation, and research. In teaching, it assists instructors through virtual experiments, lesson preparation support, knowledge mapping, and assignment design. For learning, it serves as an intelligent study assistant for students, providing automated assignment review, enabling educational resource sharing, and facilitating personalized learning pathways. In evaluation, the platform automates assignment grading, analyzes student performance data, and offers diagnostic feedback and teaching recommendations. In research, it aids educators in collecting and analyzing teaching data, as well as searching for and summarizing relevant literature. ResultsThe results indicate that an educational model integrating teacher-led instruction, student-centered learning, and generative AI assistance significantly enhances teaching quality, students’ self-directed learning abilities, and knowledge mastery. Furthermore, with the support of generative AI, curriculum-based ideological education—focusing on cutting-edge disciplinary advances and topical medical issues—helps cultivate students’ medical spirit of “honoring life and healing the wounded”, thereby fostering the establishment of appropriate professional values. Finally, while generative AI presents both opportunities and challenges for higher education, this study also analyzes potential risks in its teaching applications, emphasizing the need for both instructors and students to avoid over-reliance and to ensure that technological tools consistently serve the fundamental goals of education. ConclusionThis study demonstrates that integrating generative AI, specifically via the “Rain Classroom” platform, can effectively enhance biochemistry education. By supporting teaching, learning, evaluation, and research, this approach improves both educational effectiveness and student outcomes. It also facilitates the incorporation of cutting-edge knowledge and professional ethics, nurturing a patient-centered mindset. Additionally, the study addresses potential implementation risks to ensure that such technological tools remain aligned with the core purpose of education.
2.Effect of macrophage polarization on osteogenesis-angiogenesis coupling in type 2 diabetic osteoporosis
Wenqi CAO ; Xiuzhi FENG ; Yi ZHAO ; Zhimin WANG ; Yiran CHEN ; Xiao YANG ; Yanling REN
Chinese Journal of Tissue Engineering Research 2026;30(4):917-925
BACKGROUND:Type 2 diabetes mellitus is a secondary causative factor for osteoporosis.As highly heterogeneous innate immune cells,macrophages may be polarized in a hyperglycemic environment,which affects osteogenesis-angiogenesis coupling.This may be a research target for improving bone quality in patients with type 2 diabetic osteoporosis.OBJECTIVE:To explore the role of modulating macrophage M1/M2 polarization to influence osteogenesis-angiogenesis coupling in type 2 diabetic osteoporosis and to summarize the effects of commonly used anti-glucose and anti-osteoporosis drugs and bone biorepair materials on bone osteogenesis-angiogenesis coupling by regulating macrophage M1/M2 polarization.METHODS:The keywords of"macrophage polarization,type 2 diabetes,osteoporosis,osteogenesis-angiogenesis coupling"in Chinese and"macrophages,macrophage polarization,osteogenesis-angiogenesis coupling"in English were used to search for relevant literature in CNKI and PubMed,respectively.Seventy-nine pieces of literature were screened and analyzed.RESULTS AND CONCLUSION:(1)Type 2 diabetes mellitus causes the body to be in a hyperglycemic environment and increases the secretion of inflammatory-related factors in the body,which promotes macrophage polarization towards M1 and decreases the number of M2 macrophages.(2)In type 2 diabetes,promoting M2 macrophage polarization is beneficial for osteogenesis-angiogenesis coupling.(3)Some anti-glycemic drugs,active ingredients in traditional Chinese medicine and bone biorepair materials can improve type 2 diabetic osteoporosis by regulating macrophage M1/M2 polarization,reducing M1/M2 ratio,and promoting osteogenesis-angiogenesis coupling.
3.Effect of macrophage polarization on osteogenesis-angiogenesis coupling in type 2 diabetic osteoporosis
Wenqi CAO ; Xiuzhi FENG ; Yi ZHAO ; Zhimin WANG ; Yiran CHEN ; Xiao YANG ; Yanling REN
Chinese Journal of Tissue Engineering Research 2026;30(4):917-925
BACKGROUND:Type 2 diabetes mellitus is a secondary causative factor for osteoporosis.As highly heterogeneous innate immune cells,macrophages may be polarized in a hyperglycemic environment,which affects osteogenesis-angiogenesis coupling.This may be a research target for improving bone quality in patients with type 2 diabetic osteoporosis.OBJECTIVE:To explore the role of modulating macrophage M1/M2 polarization to influence osteogenesis-angiogenesis coupling in type 2 diabetic osteoporosis and to summarize the effects of commonly used anti-glucose and anti-osteoporosis drugs and bone biorepair materials on bone osteogenesis-angiogenesis coupling by regulating macrophage M1/M2 polarization.METHODS:The keywords of"macrophage polarization,type 2 diabetes,osteoporosis,osteogenesis-angiogenesis coupling"in Chinese and"macrophages,macrophage polarization,osteogenesis-angiogenesis coupling"in English were used to search for relevant literature in CNKI and PubMed,respectively.Seventy-nine pieces of literature were screened and analyzed.RESULTS AND CONCLUSION:(1)Type 2 diabetes mellitus causes the body to be in a hyperglycemic environment and increases the secretion of inflammatory-related factors in the body,which promotes macrophage polarization towards M1 and decreases the number of M2 macrophages.(2)In type 2 diabetes,promoting M2 macrophage polarization is beneficial for osteogenesis-angiogenesis coupling.(3)Some anti-glycemic drugs,active ingredients in traditional Chinese medicine and bone biorepair materials can improve type 2 diabetic osteoporosis by regulating macrophage M1/M2 polarization,reducing M1/M2 ratio,and promoting osteogenesis-angiogenesis coupling.
4.Elevated risk of recurrent stroke in females after patent foramen ovale closure for cryptogenic stroke:A 4-year retrospective cohort study
Weiwei XIAO ; Feng LIU ; Chen WAN ; Xiang XU ; Hao GAO ; Xiaolong LI ; Xin WEI ; Zhiyuan SONG ; Huakang LI
Journal of Army Medical University 2025;47(22):2805-2813
Objective To investigate the effect of gender on prognosis after transcatheter patent foramen ovale(PFO)closure in patients with cerebral infarction or transient ischemic attack.Methods A retrospective cohort study was conducted involving patients with cerebral infarction or transient ischemic attack(TIA)who underwent PFO closure at our hospital between January 2013 and December 2023.The patients were grouped by gender,and related data were collected,including age,comorbidities,Risk of Paradoxical Embolism(RoPE)score,laboratory results,findings of transthoracic/transesophageal echocardiography(TTE/TEE),and post-procedural complications,such as device-related thrombosis(DRT),recurrent stroke,bleeding,and atrial fibrillation(AF).Results A total of 112 patients were enrolled,including 59 males and 53 females,at a mean age of 42.47±12.35 years.The females had significantly higher preoperative RoPE score than the males(6.6±1.4 vs 6.0±1.5,P=0.046),and a statistical difference was observed in the distribution of infarction sites between them(Chi-square=10.25,P=0.006),indicating that the males were prone to posterior circulation infarction.Intraoperative transthoracic echocardiography revealed a greater distance from the PFO to the aortic root in the females(9.3±2.4 mm vs 7.6±2.0 mm,P<0.001).During a median follow-up of 4 years,the male group had 1 case of myocardial infarction,1 cerebral hemorrhage,1 paroxysmal AF,2 gingival bleeding episodes,and 1 skin ecchymosis.In the female group,1 case experienced pulmonary embolism,1 paroxysmal atrial fibrillation,3 gingival bleeding episodes,2 skin ecchymoses,2 recurrent cerebral infarctions,and 2 recurrent TIAs.There was no statistical difference in overall adverse events between gender(P=0.291).Although the females had higher rates of recurrent cerebral infarction and TIA,this difference lacked statistical significance(P=0.222).Multivariate Cox regression analysis indicated that after adjusting for various potential confounding factors,such as RoPE score,age,hypertension,coronary heart disease,and other factors,gender was not an independent predictor of composite endpoint events after surgery.Conclusion Gender does not significantly affect overall prognosis after PFO closure in patients with cerebral infarction or TIA.However,females showed a trend toward higher rates of recurrent cerebral infarction and TIA.
5.Determination of 238Pu,239Pu,240Pu and 241Pu in Soil by Tandem Quadrupole Inductively Coupled Plasmon-Mass Spectrometry
Yi-Chao GUO ; Chen-Yang PENG ; Xin-Yu DU ; Feng ZHANG ; Hao-Lin ZHOU ; Ke-Liang SHI ; Shan XING ; Xiao-Lin HOU
Chinese Journal of Analytical Chemistry 2025;53(3):397-406
Plutonium isotopes(238Pu,239Pu,240Pu and 241Pu)in the environment are important"fingerprint"nuclides in the study of nuclear activity traceability.The content of plutonium isotopes in the environmental metrics is usually very low,and the measurement of these isotopes,especially 238Pu,using mass spectrometry is seriously interfered with by the coexisting 238U.The analysis of several plutonium isotopes in soil usually requires combination of multiple measurement techniques,which leads to a long analysis time and large uncertainty in the isotope ratio.In this work,the hydrous titanium oxide(HTiO)precipitated by the hydrolysis of titanium oxydichloride(TiOCl2)under near-neutral condition was used to preconcentrate plutonium from the soil digestion solution,and the highly efficient decontamination of 238U in the sample was achieved by TK200 resin column chromatography with a decontamination factor of 108.Simulation resuts of density functional theory(DFT)showed that NH3 was considered as a promising reaction gas to eliminate the interference of 238U from 238Pu measurement using mass spectrometry due to the significant discrepancy of the chemical reactivity of U+and Pu+with the reactive gas NH3.Experiments confirmed that by optimizing the flow rates of collision gas(He)and reaction gas(NH3),the interference of 238U could be effectively suppressed,and the decontamination factor of 238U was 104.Combined with chemical separation,the overall decontamination factor of 238U could reach 1012 by using the developed method.By combining chemical separation and tandem quadrupole inductively coupled plasmon-mass spectrometry(ICP-MS/MS)measurement,the simultaneous determination of four ultra-trace plutonium isotopes in soil was realized,and the detection limit of plutonium isotopes was at the femtogram level.Analysis of the international standard reference materials(NIST-SRM-4357 and IAEA-384)showed that the established method could be successfully used for the accurate analysis of ultra-trace four plutonium isotopes(238Pu,239Pu,240Pu and 241Pu)in soil samples.
6.An Electronic Microbial Growth Analyzer-based Method for Rapidly Screening Viable Salmonella in Food
Ruo-Han LIANG ; Xiao-Dan PU ; Feng LU ; Xue-Ting ZHU ; Yuan-Yuan ZHANG ; Xiao-Yang WANG ; Qian-Qian YANG ; Hao LI ; Xu-Zhi ZHANG ; Chen-Zhong LI ; Shan LIU
Chinese Journal of Analytical Chemistry 2025;53(10):1694-1704
Foodborne illnesses caused by Salmonella pose significant threats to worldwide public health safety.In this study,a rapid method for screening viable Salmonella in oyster sauce and milk was developed by utilizing an electronic microbial growth analyzer(EMGA).Target food samples were diluted 10-fold with RVS broth and loaded into test tubes.Test tubes were positioned in the EMGA to determine the bacterial growth curves and the time required to reach the maximum growth rate(Tmgr).Using Salmonella typhimurium(S.typhimurium)asan model species,there was linear relationship between the logarithmic value of viable bacterial concentration(lgC)and Tmgr over the range of 5×101-5×106 CFU/mL,with a detection limit of 10 CFU/mL.For oyster sauce,the regression equation was Tmgr(min)=-80.775lg[C/(CFU/mL)]+754.96(R2=0.9907),and the recovery rates of S.typhimurium ranged from 95.2%to 119.8%,with relative standard deviations(RSD)ranging from 3.5%to 16.3%.For milk,the regression equation was Tmgr(min)=-71.922 lg[C/(CFU/mL)]+618.65(R2=0.9985),with recovery rates ranging from 98.4%to 110.6%and RSD ranging from 6.4%to 12.8%.The EMGA method required only one portable instrument,and involving only three manual steps,i.e.,dilution,transfer,and insertion.When S.typhimurium contamination reached 106 CFU/mL,the total time consumption,from the unwrapping of samples to the readout of bacterial concentration,was no more than 7 h.When applied to detection of actual oyster sauce and milk samples,the new method demonstrated strong consistency with plate counting results in positive detection rates.This method was superior to the plate counting method,which was generally considered as a gold standard,in terms of accuracy,precision,simplicity and efficiency,representing a promising alternative for the on-site screening and quantification of viable Salmonella in oyster sauce and milk products.
7.Comparison of Three Drowning-related Plankton Testing Methods in Drowning Diagnosis
Xiao-Feng ZHANG ; Qin SU ; Xiao-Hui CHEN ; Wei-Bin WU ; Dong-Yun ZHENG ; Jian ZHAO ; Ling CHEN ; Qu-Yi XU ; Chao LIU
Journal of Forensic Medicine 2025;41(3):244-251
Objective To compare the application effects of plankton multiplex polymerase chain reac-tion-capillary electrophoresis(PCR-CE),SYBR Green Ⅰ real-time quantitative PCR(qPCR)and microwave digestion-vacuum filtration-automated scanning electron microscopy(MD-VF-Auto SEM)in the diagnosis of drowning.Methods Lung,liver and kidney tissues from 212 drowned corpses and 30 non-drowned corpses were examined respectively by the three drowning-related plankton testing methods,and the detection rates of plankton in each tissue by three methods were compared.Results In drowned corpses,the total detection rates of PCR-CE,qPCR,and MD-VF-Auto SEM were 93.9%,96.2%,and 95.3%,respectively,with no statistically significant difference(P>0.05).The detection rate of lung tissue by MD-VF-Auto SEM(100%)was higher than those of PCR-CE and qPCR(P<0.05),and there was no significant difference in the detection rates of the three methods in liver or kidney tissues(P>0.05).In non-drowning corpses,a small number of diatoms(less than 10 cells/10 g)were detected by MD-VF-Auto SEM method,only in liver and kidney tissues,while the other two methods yielded negative results for all tissues.Conclusion All three methods have good efficacy in the examination of drowned corpses.The MD-VF-Auto SEM method directly observes diatom morpho-logical characteristics through scanning electron microscopy,and the qualitative and quantitative analy-ses are intuitive and accurate.It has great advantages in the examination of difficult degradation samples.The PCR-CE method and qPCR method have a low sample demand(0.5 g),are easy to operate and have short detection time(4-7 h).They are easy to be applied in the grassroots depart-ments and are suitable for the rapid determination of drowned corpses in routin cases.The combina-tion of the two DNA methods with the MD-VF-Auto SEM method can increase the detection rate of plankton,ensuring the reliability of examination results.This combined use is of significant importance in the application of drowning diagnosis.
8.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
9.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
10.Predictive study on the reliability of PLT-I results when platelet histograms are abnormal
Ting XIAO ; Li ZHOU ; Jiayi MA ; Yuze FENG ; Ming CHEN ; Hanqing XU
International Journal of Laboratory Medicine 2025;46(9):1097-1103
Objective To explore the factors predicting the reliability of platelet-impedance(PLT-I)re-sults through a retrospective analysis of non-aggregated samples with abnormal platelet histograms.Methods A total of 322 samples with abnormal platelet histograms were collected from the Sysmex XN9000 automatic hematology analyzer,all of which showed no platelet aggregation as determined by the DI-60 auto-matic digital image analysis system.Using the platelet count fluorescent(PLT-F)results as a standard,the absolute and relative deviations of PLT-I results were calculated,and the parameters of samples with devia-tions within and outside the allowable range were analyzed.Logistic regression analysis was used to identify potential factors associated with deviations of PLT-I from PLT-F beyond the allowable range.The receiver op-erating characteristic(ROC)curve was used to evaluate the predictive value of these potential factors for devi-ations beyond the allowable range.Results The deviations of PLT-I from PLT-F were within the allowable range in 279 cases(86.65%)and outside the allowable range in 43 cases(13.35%).Comparisons between the two groups revealed statistically significant differences in mean red blood cell valume(MCV),red blood cell distribution width-cuefficient of variation(RDW-SD),DI-60 red cell fragments,platelet distribution width(PDW),and DI-60 large platelet ratio(P<0.05).Logistic regression indicated that DI-60 red cell fragments and DI-60 large platelet ratio were independent potential factors for deviations of PLT-I from PLT-F beyond the allowable range(P<0.05).The cut off values for predicting deviations beyond the allowable range were 1.75 for DI-60 red cell fragments and 66%for DI-60 large platelet ratio.The area under the curve(AUC)for the combined diagnosis of the two factors was 0.813,with a sensitivity of 88.4%and a specificity of 66.3%,indicating a higher predictive value than individual factors(P<0.05).Conclusion When platelet histograms are abnormal,DI-60 large platelet ratio and DI-60 red cell fragments are independent potential factors predic-ting the reliability of PLT-I results,and their combination has a high predictive value.

Result Analysis
Print
Save
E-mail