1.Mechanical effect of mechanical wear of abutment screws on the Morse taper connection implant system:a three-dimensional finite element analysis
Chinese Journal of Tissue Engineering Research 2026;30(6):1375-1383
BACKGROUND:Abutment screw loosening is one of the most common mechanical complications in implant restoration.Mechanical wear,as a potential cause of thread loosening,warrants attention due to its impact on mechanical performance and long-term stability.However,studies on the mechanical effects of thread wear in abutment screws remain limited,and no definitive conclusions have been reached.OBJECTIVE:To investigate the effect of different degrees of mechanical wear on the spatial stress distribution of the Morse taper connection implant system,with a view to providing a theoretical basis for the clinical assessment of the long-term stability of dental implants.METHODS:Three-dimensional finite element models of Morse taper implants with central screw thread wear levels of 0,0.1,1,10,and 100 μm were established using SolidWorks software,and simulation analysis with Ansys Workbench software was performed.The implant models were inserted into artificial bone blocks(simulating type Ⅱ bone,with a cortical bone thickness of 2 mm on the outer layer and cancellous bone inside).An alternating load of 300 N in the buccolingual direction was applied at the centroid of the abutment(forming an angle of 30° with the long axis of the implant).The von Mises stress,principal stress,displacement,and fatigue life of the abutment,central screw,implant,and bone tissue in the five groups of models were analyzed.RESULTS AND CONCLUSION:(1)As the degree of mechanical wear on the central screw thread increased,the von Mises stress,principal stress,and strain in the implant and abutment also increased.The stress in the model was concentrated at the top of the implant,at the shoulder level of the implant,at the neck of the abutment,and at the bottom edge of the abutment.(2)Under moderate wear conditions(≥ 10 μm),the fatigue life of the implant system decreased by 30%,and the maximum von Mises stress of the central screw decreased by 37%,with the stress still primarily concentrated at the transition area between the head and the body of the central screw.(3)Under significant wear conditions(≥ 100 μm),the von Mises stress of the central screw decreased by 98%,with the stress concentrated at the screw head,and the fatigue life of the implant system decreased by 63%.Therefore,when the wear level of the central screw thread reaches ≥ 10 μm,the risk of screw loosening is significantly increased,and the fatigue life of the implant system is markedly reduced,warranting clinical attention.
2.Mechanical effect of mechanical wear of abutment screws on the Morse taper connection implant system:a three-dimensional finite element analysis
Chinese Journal of Tissue Engineering Research 2026;30(6):1375-1383
BACKGROUND:Abutment screw loosening is one of the most common mechanical complications in implant restoration.Mechanical wear,as a potential cause of thread loosening,warrants attention due to its impact on mechanical performance and long-term stability.However,studies on the mechanical effects of thread wear in abutment screws remain limited,and no definitive conclusions have been reached.OBJECTIVE:To investigate the effect of different degrees of mechanical wear on the spatial stress distribution of the Morse taper connection implant system,with a view to providing a theoretical basis for the clinical assessment of the long-term stability of dental implants.METHODS:Three-dimensional finite element models of Morse taper implants with central screw thread wear levels of 0,0.1,1,10,and 100 μm were established using SolidWorks software,and simulation analysis with Ansys Workbench software was performed.The implant models were inserted into artificial bone blocks(simulating type Ⅱ bone,with a cortical bone thickness of 2 mm on the outer layer and cancellous bone inside).An alternating load of 300 N in the buccolingual direction was applied at the centroid of the abutment(forming an angle of 30° with the long axis of the implant).The von Mises stress,principal stress,displacement,and fatigue life of the abutment,central screw,implant,and bone tissue in the five groups of models were analyzed.RESULTS AND CONCLUSION:(1)As the degree of mechanical wear on the central screw thread increased,the von Mises stress,principal stress,and strain in the implant and abutment also increased.The stress in the model was concentrated at the top of the implant,at the shoulder level of the implant,at the neck of the abutment,and at the bottom edge of the abutment.(2)Under moderate wear conditions(≥ 10 μm),the fatigue life of the implant system decreased by 30%,and the maximum von Mises stress of the central screw decreased by 37%,with the stress still primarily concentrated at the transition area between the head and the body of the central screw.(3)Under significant wear conditions(≥ 100 μm),the von Mises stress of the central screw decreased by 98%,with the stress concentrated at the screw head,and the fatigue life of the implant system decreased by 63%.Therefore,when the wear level of the central screw thread reaches ≥ 10 μm,the risk of screw loosening is significantly increased,and the fatigue life of the implant system is markedly reduced,warranting clinical attention.
3.A method for the simultaneous determination of 12 antipsychotic drugs and their main metabolites in human serum
Xi CHEN ; Yanfang XIAO ; Yang DING ; Weitao HONG ; Lijun MAI ; Xuan ZENG
Sichuan Mental Health 2026;39(2):140-148
BackgroundMonitoring the blood concentrations of antipsychotic drugs and their metabolites can guide the adjustment of clinical treatment plans, improving therapeutic efficacy while reducing adverse effects. However, there is currently a lack of a method that can accurately and efficiently quantitatively detect multiple antipsychotic drugs and their metabolites. ObjectiveTo establish a ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous identification and quantitation of 12 antipsychotic drugs and their main metabolites in human serum. MethodsUsing UPLC-MS/MS technology, protein precipitation method was employed for sample pretreatment. An Agela Technologies Durashell C8 chromatographic column (50 mm×3.0 mm, 5 μm) was selected for chromatographic separation with gradient elution. The flow rate was 0.4 mL/min, and the total analysis time was 5 minutes. The column temperature was 40℃. The mass spectrometry detection was carried out in the multiple reaction monitoring (MRM) mode, and the isotope internal standard method was used for quantification. ResultsThe relative standard deviation (RSD) of the internal standard normalization matrix effect factor for 12 antipsychotic drugs and their main metabolites at low and high quality concentrations was all less than 15%. The extraction recovery rate was 85% to 115%. They showed good linear relationships within their respective standard curve ranges (r>0.995). At low, medium, and high quality concentrations, the accuracy was 85.24% to 114.71%, and the RSD of intra-batch and inter-batch precision was all ≤14.15%, with good stability. ConclusionAll the analytical performance indicators of this method meet the verification requirements, providing an analytical means for the quantitative detection of antipsychotic drugs and their main metabolites in human serum. [Funded by The Third Batch of Science and Technology Projects in Chaozhou City in 2023 (number, 202303GY02)]
4.Fluorescence Method for Determination of Metolazone and Valsartan in Human Serum and Urine:A Comparison from Zero-order to Second-order Calibration Method
Zi-Wei DING ; Hai-Long WU ; Xiao-Zhi WANG ; Tong WANG ; Hao-Ran LIU
Chinese Journal of Analytical Chemistry 2025;53(2):224-234
A second-order calibration method combined with excitation-emission matrix(EEM)fluorescence spectroscopy was presented for simultaneous quantitative analysis of two anti-hypertensive drugs,metolazone(MET)and valsartan(VAL),in human serum and urine,and the quantitative results were compared with the results obtained by zero-and first-order calibration methods.The results indicated that the methods based on zero-and first-order calibration were inadequate for accurately quantifying the components of interest in cases where severe spectral overlap and unknown interferences coexisted.However,it was possible to obtain satisfactory results with the second-order calibration method based on alternating normalization-weighted error(ANWE)algorithm because of its strong"mathematical separation",even when the fluorescence spectra of the target analytes and unknown interferents considerably overlapped.Correlation coefficients for both analytes were greater than 0.99,with mean recoveries of 104.9%±5.7%and 107.8%±9.2%for MET and VAL in human serum,and 103.7%±8.9%and 94.7%±3.8%in human urine,respectively.In addition,the sensitivity,selectivity,limit of detection,limit of quantification,repeatability,and reproducibility of the proposed second-order calibration method were thoroughly examined.All results indicated that the established method was capable of achieving simultaneous and accurate quantification of MET and VAL in human body fluids,which was expected to be applied to analysis of both drugs in clinical settings.
5.Study of Reference Materials for Quantitative Analysis of Gene Copy Numbers of Lentiviral Vectors
Yin-Bo HUO ; Jia-Qi YANG ; Qing TAO ; Wen LIANG ; Li XU ; Lan-Ying LI ; Xiao-Lei ZUO ; Juan YAN ; Min DING ; Ai-Wen MA ; Gang LIU
Chinese Journal of Analytical Chemistry 2025;53(9):1555-1565
Lentiviral vectors(LVs)are key gene delivery tools for integrating target genes into the host genome,but they may also pose risks of insertional mutagenesis.The vector copy number(VCN)in cells is critical for determining the safety of gene modification.However,the reliability and accuracy of its quantification process are influenced by multiple factors.Developing cell reference materials with specific vector copy numbers represents a viable approach to enhance the reliability and consistency of measurement results,enabling quality control of the quantification process and traceability of outcomes.However,the preparation of such reference materials faces challenges in cell sample design,preparation protocols,and advanced quantification techniques.In this study,T lymphocyte cell line Jurkat-based reference materials with LV gene copy numbers of 1 and 2 copy/cell were developed.A high-precision duplex digital polymerase chain reaction(dPCR)method was established to quantify the LV gene and endogenous genes simultaneously.Additionally,the results of dPCR were cross-validated through next-generation sequencing and flow cytometric analysis.Ultimately,confocal microscopy characterization results showed that the developed cell reference materials had intact morphology.The quantification result of VCN-1 was(1.07±0.11)copy/cell,and that of VCN-2 was(2.09±0.21)copy/cell.These cell reference materials demonstrated compliance with stability and homogeneity requirements,and could be applied for quality control throughout the VCN measurement workflow and metrological traceability,improving the accuracy,comparability,and validity of copy number measurements.
6.Estimate the Age of Han Adult Based on the Pulp Chamber Volume and Pulp Dentinal Index of Right First Molars Using Oral and Maxillofacial CBCT
Yan-Jie DING ; Xiao ZHANG ; Wen-Li SHI ; Zi-Yi LI ; Wei WANG ; Shi-Lin ZHANG ; Gen-Jie YANG ; A-Ji GUO ; Bo JIN
Journal of Forensic Medicine 2025;41(1):59-65
Objective To explore the correlation between the actual age and the pulp chamber volume(PCV)and pulp dentinal index(PDI)of the right first molars based on cone beam computed tomog-raphy(CBCT)technology,and to construct an accurate and convenient model for age estimation.Methods CBCT image data of 1 857 Han adults(883 males and 974 females)from the Department of Stomatology,Affiliated Hospital of North Sichuan Medical College were collected.The data were di-vided into training and validation sets at a ratio of 8∶2.A total of 1 485 training samples were used to construct the age estimation model,and 372 samples were used to validate the accuracy of the model.The Mimics 21.0 software was used to measure the PCV and calculate the PDI of the right first molars.Their correlations with age and the differences between different sexes and tooth positions were analyzed.Results Both the PCV and the PDI of the first molars showed strong negative correla-tions with the actual age(r values ranged from 0.82 to 0.89).The differences in PCV and PDI be-tween different sexes and tooth positions were statistically significant(P<0.05).The age estimation model based on PDI was superior to that based on PCV.The model based on the PDI values of the two right first molars(y=73.72-44.15 x3-28.27 x4,where x3 and x4 are the PDI values of the right maxil-lary and mandibular first molars,respectively)was the best,with the R2 of 0.79 and the mean abso-lute error of 4.90 years.Conclusion Both PCV and PDI of the first molars are effective indicators for age estimation.The age estimation model based on the PDI is more convenient and accurate than that based on the PCV,providing a more effective method for age estimation in forensic practice.
7.Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in anterior mediastinal masses
Junmin ZHU ; Junjie WANG ; Jianming YUE ; Yixin SUN ; Yichen LIU ; Lei WANG ; Lin LIN ; Jie LI ; Jinlan ZHAO ; Xuehua TU ; Ningying DING ; Jianrong HU ; Chunmei HE ; Leilei TIAN ; Hongtao TANG ; Jiasheng ZHAO ; Cheng CHEN ; Yongxiang SONG ; Yunwei TIAN ; Yong XIAO ; Kaidi LI ; Lin MA ; Yun WANG ; Longqi CHEN ; Dong TIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(11):1603-1609
Objective To assess the clinical value of a novel surgical technique—Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in the resection of anterior mediastinal masses. Methods Patients who underwent tubeless subxiphoid uniportal video-assisted thoracoscopic surgery via balance-shaped sternal elevation device in anterior mediastinal masses process at the Department of Thoracic Surgery, West China Hospital, Sichuan University from March to April 2025 were included, and their clinical data were analyzed. Results A total of 4 patients were included, with 2 males and 2 females, aged 58-75 years. The diameter of the tumor was 2.5-3.0 cm. The operation time was 60.0-150.0 min, intraoperative blood loss was 5-10 mL, pain score on the 3rd day after surgery was 0 points, and postoperative hospital stay was 2-3 days. All patients achieved complete resection of the masses and thymus without perioperative complications. Conclusion The tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device technique optimizes surgical visualization and instrument maneuverability while avoiding complications related to conventional anesthesia and tubing, thereby markedly enhancing the minimally invasive profile of anterior mediastinal masses resections. In addition to maintaining procedural safety, this approach effectively reduces postoperative pain and accelerates patient recovery, highlighting its potential for widespread clinical adoption.
8.Efficacy and safety of microwave ablation via different approaches for pulmonary nodules: A retrospective cohort study
Hao ZHANG ; Shenyun SHI ; Xinying LI ; Rujia WANG ; Lijun REN ; Jingjing DING ; Yonglong XIAO ; Min YU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(11):1554-1560
Objective To compare the efficacy and safety of computed tomography (CT)-guided percutaneous versus electromagnetic navigation bronchoscopy (ENB)-guided microwave ablation (MWA) for the treatment of pulmonary nodules. Methods A retrospective analysis was conducted on the data of high-risk pulmonary nodule patients who underwent MWA at the Nanjing Drum Tower Hospital between 2022 and 2023. The pathological diagnosis rate, complications, and progression-free survival (PFS) rate were compared between the CT group and the ENB group. Results There were 61 patients in the CT group, including 30 males and 31 females, with an average age of (67.22±9.13) years. There were 53 patients in the ENB group, including 29 males and 24 females, with an average age of (65.29±13.76) years. The pathological diagnosis rate in the CT group was slightly higher than that in the ENB group (88.52% vs. 71.69%, P=0.03). However, the ENB group exhibited a lower incidence of perioperative complications, including pneumothorax (16.39% vs. 3.77%, P=0.03), hemoptysis (19.67% vs. 5.66%, P=0.05), and pain (22.95% vs. 7.55%, P=0.03). There was no statistically significant difference in PFS rate between the two groups [HR=1.17, 95%CI (0.23, 5.81), P=0.85]. Conclusion Both CT-guided and ENB-guided MWA are effective treatment modalities for high-risk pulmonary nodules.
9.Effects of different exercise interventions on carboxylesterase 1 and inflammatory factors in skeletal muscle of type 2 diabetic rats
Shujuan HU ; Ping CHENG ; Xiao ZHANG ; Yiting DING ; Xuan LIU ; Rui PU ; Xianwang WANG
Chinese Journal of Tissue Engineering Research 2025;29(2):269-278
BACKGROUND:Carboxylesterase 1 and inflammatory factors play a crucial role in regulating lipid metabolism and glucose homeostasis.However,the effects of different exercise intensity interventions on carboxylesterase 1 and inflammatory factors in skeletal muscle of type 2 diabetic rats remain to be revealed. OBJECTIVE:To investigate the effects of different exercise intensity interventions on carboxylesterase 1 and inflammatory factors in skeletal muscle of type 2 diabetic rats. METHODS:Thirty-two 8-week-old male Sprague-Dawley rats were randomly divided into normal control group(n=12)and modeling group(n=20)after 1 week of adaptive feeding.Rat models of type 2 diabetes mellitus were prepared by high-fat diet and single injection of streptozotocin.After successful modeling,the rats were randomly divided into diabetic control group(n=6),moderate-intensity exercise group(n=6)and high-intensity intermittent exercise group(n=6).The latter two groups were subjected to treadmill training at corresponding intensities,once a day,50 minutes each,and 5 days per week.Exercise intervention in each group was carried out for 6 weeks.After the intervention,ELISA was used to detect blood glucose and blood lipids of rats.The morphological changes of skeletal muscle were observed by hematoxylin-eosin staining.The mRNA expression levels of carboxylesterase 1 and inflammatory cytokines were detected by real-time quantitative PCR.The protein expression levels of carboxylesterase 1 and inflammatory cytokines were detected by western blot and immunofluorescence. RESULTS AND CONCLUSION:Compared with the normal control group,fasting blood glucose,triglyceride,low-density lipoprotein cholesterol,insulin resistance index in the diabetic control group were significantly increased(P<0.01),insulin activity was decreased(P<0.05),and the mRNA and protein levels of carboxylesterase 1,never in mitosis gene A related kinase 7(NEK7)and interleukin 18 in skeletal muscle tissue were upregulated(P<0.05).Compared with the diabetic control group,fasting blood glucose,triglyceride,low-density lipoprotein cholesterol,and insulin resistance index in the moderate-intensity exercise group and high-intensity intermittent exercise group were down-regulated(P<0.05),and insulin activity was increased(P<0.05).Moreover,compared with the diabetic control group,the mRNA level of NEK7 and the protein levels of carboxylesterase 1,NEK7 and interleukin 18 in skeletal muscle were decreased in the moderate-intensity exercise group(P<0.05),while the mRNA levels of carboxylesterase 1,NEK7,NOD-like receptor heat protein domain associated protein 3 and interleukin 18 and the protein levels of carboxylesterase 1 and interleukin 18 in skeletal muscle were downregulated in the high-intensity intermittent exercise group(P<0.05).Hematoxylin-eosin staining showed that compared with the diabetic control group,the cavities of myofibers in the moderate-intensity exercise group became smaller,the number of internal cavities was reduced,and the cellular structure tended to be more intact;the myocytes of rats in the high-intensity intermittent exercise group were loosely arranged,with irregular tissue shape and increased cavities in myofibers.To conclude,both moderate-intensity exercise and high-intensity intermittent exercise can reduce blood glucose,lipid,insulin resistance and carboxylesterase 1 levels in type 2 diabetic rats.Moderate-intensity exercise can significantly reduce the expression level of NEK7 protein in skeletal muscle,while high-intensity intermittent exercise can significantly reduce the expression level of interleukin 18 protein in skeletal muscle.In addition,the level of carboxylesterase 1 is closely related to the levels of NEK7 and interleukin 18.
10.Dispersion effect of bone cement after vertebroplasty using individualized unilateral external pedicle approach and bilateral pedicle approach
Lichuang ZHANG ; Wen YANG ; Guangjiang DING ; Peikun LI ; Zhongyu XIAO ; Ying CHEN ; Xue FANG ; Teng ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(4):800-808
BACKGROUND:According to existing clinical studies,vertebroplasty treatment with both the external pedicle approach and the pedicle approach can improve the pain and quality of life of patients with spinal compression fractures.Compared with the pedicle approach,the external pedicle approach has a freer puncture angle,and good bone cement dispersion effect can be obtained by adjusting the puncture angle. OBJECTIVE:To compare the impact of vertebroplasty through individualized unilateral external pedicle approach and bilateral pedicle approach on the treatment of spinal compression fractures by quantifying the dispersion effect of bone cement. METHODS:A total of 80 patients with thoracolumbar compression fracture were divided into two groups by random number table method.The bilateral pedicle group(n=40)underwent vertebroplasty through a bilateral pedicle approach,while the unilateral external pedicle group(n=40)underwent individualized vertebroplasty through a unilateral external pedicle approach.Anteroposterior and lateral X-rays of the affected vertebrae from two groups of patients were photographed to assess effect and type of bone cement dispersion within 3 days after surgery.Visual analog scale score,tenderness threshold around fracture,and Oswestry dysfunction index were assessed before,1,7 days,and 1 month after surgery. RESULTS AND CONCLUSION:(1)Dispersion effect of bone cement in unilateral external pedicle group was better than that in bilateral pedicle group(P<0.001),and the amount of bone cement perfusion was higher than that in bilateral pedicle group(P<0.001).In the bilateral pedicle group,the bone cement dispersion types were mainly concentrated in type Ⅰ and type Ⅲ,while in the unilateral external pedicle group,the bone cement dispersion types were mainly concentrated in type I and type Ⅱ,and there was a significant difference in bone cement dispersion types between the two groups(P<0.001).(2)Postoperative visual analog scale scores and Oswestry disability index of both groups were lower than those before surgery(P<0.001),and postoperative tenderness threshold around fracture showed a trend of decreasing first and then increasing.At the same time point after treatment,there were no significant differences in visual analog scale score,Oswestry disability index,and tenderness threshold around fracture between the two groups(P>0.05).(3)The results indicate that individualized vertebroplasty via unilateral external pedicle approach can achieve better bone cement dispersion,and the treatment effect is consistent with the vertebroplasty via classical bilateral pedicle approach.

Result Analysis
Print
Save
E-mail