1.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
2.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
3.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
4.Clinical Value of Contrast Echocardiography in Distinguishing Right Heart System Space-occupying Lesions
Chongjun XU ; Chengfang YU ; Hongmei SHEN ; Na LU ; Xianwu CHENG
Chinese Circulation Journal 2024;39(5):490-494
Objectives:To investigate the clinical value of contrast echocardiography in the detection of right heart space-occupying lesions. Methods:The imaging and clinical data of 39 patients with right heart space-occupying lesions confirmed by surgery,pathology and clinical treatment in Yanbian University Hospital from January 2019 to January 2023 were retrospectively analyzed.All patients underwent contrast echocardiography and cardiac magnetic resonance(CMR)examinations.The contrast echocardiography features of right heart neoplastic from non-neoplastic occupying lesions were summarized.The diagnostic efficacy of contrast echocardiography and CMR in right heart space-occupying lesions was compared. Results:Among the 39 patients,12 patients(30.8%)were confirmed as thrombus and vegetation,6 patients(15.4%)as benign tumors and 21 patients(53.8%)as malignant tumors.There were 8,4,4 and 17 patients of thrombus,vegetation,benign tumor and malignant tumors located in right atrium,respectively.Contrast echocardiography was used to diagnose thrombus and vegetation in 12 patients(30.8%),benign tumors in 5 patients(12.8%),malignant tumors in 22 patients(56.4%).CMR was used to diagnose thrombus and vegetation in 18 patients(46.2%),benign tumors in 5 patients(12.8%),malignant tumors in 16 patients(41.0%).The Kappa coefficient between contrast echocardiography and clinical diagnosis was 0.956(P<0.001).The Kappa coefficient between CMR and clinical diagnosis was 0.754(P<0.001). Conclusions:Contrast echocardiography can dynamically observe the degree of vascularization in the lesion tissue in real-time,accurately distinguishing the nature of the right heart space-occupying lesions.
5.Total ureteral avulsion caused by uterine evacuation: a case report
Shouyi LONG ; Guangjie LI ; Xianwu SUN ; Yiheng LI ; Guobiao LIANG ; Shulian CHEN
Chinese Journal of Urology 2023;44(2):142-143
Currently, the total ureteral avulsion are mainly secondary to ureteroscopy, and it is rarely caused by uterine evacuation clinically. This paper reported a case of total ureter avulsion after uterine evacuation, treating by ileal replacement for ureter under general anesthesia, and the surgical outcome was good. Uterine evacuation is a routine, less risky procedure, but it also can lead to serious complications such as total ureteral avulsion or bladder rupture. For potential high-risk patients with uterine evacuation, preventive measures such as accurate localization under B-ultrasound guidance or pre-operative ureteral stents indwelling are useful to avoid the occurrence of such serious complications. If total ureteral avulsion occurs, ileal replacement for ureter is a viable and effective treatment.
6.Implementation barriers of enhanced recovery after surgery among medical staff of Abdominal Surgery in Class Ⅲ Grade A hospitals
Chinese Journal of Modern Nursing 2020;26(4):429-434
Objective To explore the implementation barriers of enhanced recovery after surgery (ERAS)among medical staff of Abdominal Surgery in ClassⅢ Grade A hospitals so as to provide a reference for health authorities and hospital managers to develop the promotion strategy of ERAS. Methods From July to October 2017,this study selected totals of 12 doctors and nurses of Abdominal Surgery Department from 4 Class Ⅲ Grade A hospitals as interviewees by purposive sampling. In-depth interview on implementation barriers of ERAS in departments was carried out with the semi-structured interview outline. The Colaizzi method was used to interview data analysis. Results Implementation barriers of ERAS main included 6 aspects involving the difficulties in multidisciplinary collaboration,difficuties in changing traditional concept among medical staff,lack of patients' understanding and collaboration,safety remained to be tested,lack of support and safeguard measure and insufficient medical resource in primary hospitals. Conclusions ClassⅢGrade A hospitals of China are faced with barriers when implementing ERAS,including the difficulties in team collaboration,insufficient cognition of medical staff,lack of patients' understanding and collaboration, safety remained to be tested,lack of policy support and safeguard measure and insufficient medical resources in primary hospitals. Management departments should develop the targeted promotion strategy based on those barriers to promote the popularity and application of ERAS.
7.Radiological features of follicular dendritic cell tumor of spleen
Xiaodong YUAN ; Jianhua WANG ; Yutao WANG ; Dongdong REN ; Xianwu XIA ; Qianjiang DING ; Siqi WANG ; Zhihao REN ; Qiang LI
Chinese Journal of Radiology 2019;53(5):375-380
Objective To summarize the radiological features of follicular dendritic cell tumor of spleen (FDCS).Methods The clinical, radiological and pathological data of 8 patients from November 2011 to November 2017 in 5 hospitals with FDCS confirmed by pathology were retrospectively analyzed. All patients underwent CT examinations including plan and enhanced CT. Three patients underwent additional MRI and two patients underwent PET‐CT examinations simultaneously. The imaging features such as location, number, shape, boundary, size, internal structure, density (or signal, 18F‐fluorodeoxyglucose uptake), enhancement model and the relationship with surrounding structures were observed and compared with pathological results. Results Of the 8 patients with FDCS, 7 were located in the spleen and 1 was located in the spleen of the ectopic spleen of the pancreas. Seven patients with splenic FDCS underwent splenectomy and 1 patient with pancreatic ectopic spleen FDCS underwent resection of the pancreas. Multiple lesions were detected in 1 case, while single in the others. Tumor was round or oval. The tumors were well‐circumscribed and presented as expansive growth. On unenhanced CT, the tumors showed a slightly lower density, and hemorrhage and necrosis could be detected in 6 lesions. Calcification was seen in 1 case, significant necrosis, and cystic change was presented in the pancreatic ectopic spleen FDCS. The solid part presented isointensity or slightly hypointensity on T1WI, and hyperointensity on T2WI. Cystic necrosis areas were hypointensitive on T1WI, and hyperointensitive on T2WI. Spoke‐like areas with hypointensity on T1WI and hyperointensity on T2WI were detected in the center of the solid part with the distribution among the substantial degenerative and necrotic regions. PET‐CT showed that the 18F‐fluorodeoxyglucose was uptaked obviously. The enhancement CT showed that at the arterial phase, the tumors were markedly enhanced and continuously enhanced at portal vein phase and balance phase. Multiple liver metastases were detected in 1 case with huge FDCS. One patient was followed up for 6 years, and gastric lymphoma was detected. The others were followed up for 6 to 53 months, there remained no transfer or recurrence.Conclusions The features of FDCS of spleen mainly manifest as solid or cystic mass with clear solitary sphenoma accompanied by scarring, calcification and hemorrhage. The enhancement mode is persistent enhancement. MRI and PET‐CT help to further reflect the tumor pathological basis and biological characteristics.
8. Options for irreparable rotator cuff tears
Xianwu CHEN ; Ruqing YE ; Liang WANG ; Meng WANG
Journal of Chinese Physician 2019;21(10):1584-1588
Irreparable rotator cuff tear can result in pain and should disfunction, and the management of patient with it remains a challenge. A variety of treatment options have been proposed, such as debridement, tuberplasty, partial rotator cuff repair, patch augmented rotator cuff repair, tendon transfers, superior capsule reconstruction, suprascapular nerve ablation or kill, inpace and reverse shoulder arthroplasty. These procedures are still widely debated, The aim of this review is to summarise procedures and the results, the operative essence is to restore the stable rotation center of glenohumeral joint, the choice is dictated by our special need.
9. Blocking effects of serum antibodies against HBGA binding to norovirus GII.4 of population in oyster culture area of Guangdong Province
Yali ZHUANG ; Lin QIN ; Yingchun DAI ; Anna WANG ; Xianwu ZHONG ; Rongfeng CHEN ; Qiong HUANG ; Yonghui ZHANG
Chinese Journal of Preventive Medicine 2018;52(3):287-291
Objective:
Evaluate GII.4 norovirus infection and blocking effects of serum antibodies against HBGAs binding to GII.4 norovirus of population in oyster culture area, provide references for screening of fully human monoclonal antibody.
Methods:
Using a random survey method to collect blood and saliva samples in oyster culture area, select serum samples from the inland region of Guangdong as control group. Identification of salivary HBGA receptor phenotype and detection of serum antibody levels between two areas by ELISA. A vitro neutralization model was to determine the efficiency of serum antibodies blocking GII.4 norovirus and HBGA receptors binding.
Results:
The age were (50.68 ± 15.17), (52.52 ± 15.90) and (51.37 ± 13.32) years old of 2015, 2016 in experimental group, and in control group, respectively. Males accounted for 5.9% (70/195), 36.6%(60/164), 40.8% (69/169) (χ2=0.93,

Result Analysis
Print
Save
E-mail