1.Influence of the complexity metrics of the multi-leaf collimator on the γ-pass rate of volumetric modulated arc therapy plans for nasopharyngeal carcinoma
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Weixue LIANG ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):309-316
Objective:To investigate the influence of the complexity metrics of the multi-leaf collimator (MLC) on the γ-pass rate of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC).Methods:A total of 60 VMAT plans for NPC were selected to measure the γ-pass rate. The MLC data across all control points (CPs) in each VMAT plan were analyzed to calculate the mean field area (MFA), average leaf gap (ALG), small aperture score (SAS), and their corresponding weighted metrics including MFAW, ALGW, and SASW, considering dose weight (W). Pearson′s bivariate correlation analysis was conducted to examine the correlations between MLC complexity metrics and the γ-pass rate. Moreover, the receiver operating characteristic (ROC) analysis was employed to assess the predictive efficacy of MLC complexity metrics on dose verification result.Results:Under the 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria, the MFA in the 60 VMAT plans exhibited a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.72, P<0.05), and the MFAW was also positively correlated with the γ-pass rate ( r=0.83, 0.81, 0.75, P<0.05). The ALG manifested a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.74, P<0.05), as did the ALGW ( r=0.83, 0.81, 0.77, P<0.05). The SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) displayed negative correlations with the γ-pass rate ( r= -0.86, -0.82, -0.71, -0.84, -0.82, -0.72, -0.79, -0.79, -0.73, -0.30, -0.35, -0.42, P<0.05), whereas the SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) showed positive correlations with the γ-pass rate ( r=0.49, 0.45, 0.33, 0.73, 0.71, 0.59, 0.79, 0.79, 0.76, P<0.05). The outcomes of SASW reveal slightly stronger correlations than those of SAS. In terms of correlations among complexity metrics, a positive correlation was observed between MFA and ALG ( r=0.98, P<0.05). ALG was negatively correlated with SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) ( r= -0.95, -0.94, -0.89, -0.39, P<0.05), and positively correlated with SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) ( r=0.51, 0.77, 0.92, P<0.05). The weighted result mirrored these correlations. The ROC-derived analytical result indicate that MFA, MFAW, ALG, ALGW, SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), SAS(6-40 cm), SASW(0-1 cm), SASW(1-2 cm), SASW(2-3 cm), and SASW(6-40 cm) demonstrated exceptional predictive efficacy for dose verification result [Area under the curve (AUC) > 0.9, P<0.05]. Conclusions:The γ-pass rate of VMAT plans for NPC is strongly correlated with MLC complexity metrics, which demonstrate excellent predictive efficacy for dose verification result. The increased uncertainty in dose calculations and measurements caused by narrow fields generated by the MLC is a significant factor contributing to the reduced γ-pass rate of VMAT plans. This finding is associated with discrepancies in the precision of treatment planning system (TPS) modeling and the accuracy of dose verification tools, providing a reference for similar challenges.
2.A comparative study of radiotherapy using three distinct radiotherapy techniques following immediate breast reconstruction for breast cancer
Xiantao HE ; Zhuohua XU ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):317-324
Objective:To investigate the differences in dosimetric parameters for target volumes and organs at risk (OARs), radiation doses to reconstructed tissues, and beam-on time in radiotherapy among helical tomotherapy (HT), volumetric modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (F_IMRT) following immediate breast reconstruction for breast cancer, thereby providing a reference for the selection of clinical radiotherapy techniques.Methods:This study retrospectively investigated 15 breast cancer patients who underwent radiotherapy following modified radical mastectomy and immediate breast reconstruction at the Liuzhou Worker′s Hospital from August 2018 to July 2023. During target volume delineation, precautions were taken to avoid the reconstructed tissues, which were delineated separately. Customized HT, VMAT, and F_IMRT treatment plans were designed for each patient. The plans were categorized into the HT, VMAT, and F_IMRT groups based on different radiotherapy techniques employed. They were comparatively analyzed through one-way analysis of variance (ANOVA), with multiple comparisons further conducted in the case of significant differences.Results:Statistical analyses reveal significant differences in various parameters of target volumes among the three groups of plans ( F = 38.73, 14.95, 37.01, 48.05, 35.55, 22.56, 34.30, P < 0.05). Pairwise comparisons indicate that the maximum dose ( D2%), minimum dose ( D98%), mean dose ( Dmean), and the proportion of high-dose volumes within the target volume ( V107%and V110%) in both the HT and VMAT groups were significantly better than those in the F_IMRT group. The HT group demonstrated the optimal conformity index (CI), while the VMAT group displayed the superior homogeneity index (HI) compared to the other two groups. In terms of OAR, the V20 of the ipsilateral lung was the lowest in the HT group ( F = 14.31, P < 0.05) and the highest in the F_IMRT group ( F = 14.31, P < 0.05). However, the V5 and Dmean for both the ipsilateral and contralateral lungs in the HT group significantly surpassed those of the other groups ( F = 39.16, 31.91, P < 0.05). The mean dose Dmean ( F = 5.57, P < 0.05) of the contralateral breast was significantly reduced in the VMAT group compared to the other two groups. No statistically significant differences were observed for other OARs, including the heart, spinal cord PRV, thyroid, and humeral head ( P > 0.05). The radiation doses to reconstructed tissues ( Dmax, V53.5, Dmean) ascended in the order of HT, VMAT, and F_IMRT groups ( F = 17.69, 17.53, 15.11, P < 0.05). The HT and F_IMRT groups showed similar beam-on times ( P > 0.05), both exceeding that of the VMAT group by several folds ( F = 28.72, P < 0.05). Conclusions:The comparative analysis indicates that the three radiotherapy techniques exhibit distinct advantages and limitations, with F_IMRT demonstrating the least comprehensive advantage. HT can enhance the conformity of target volumes while reducing the overall radiation doses to reconstructed tissues and the crucial indicator V20 in the ipsilateral lung. VMAT demonstrates the highest treatment efficiency, yielding improved dose uniformity in the target volume and reduced radiation doses to the contralateral breast. It is advisable to prioritize HT or VMAT based on actual clinical conditions.
3.Influence of the complexity metrics of the multi-leaf collimator on the γ-pass rate of volumetric modulated arc therapy plans for nasopharyngeal carcinoma
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Weixue LIANG ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):309-316
Objective:To investigate the influence of the complexity metrics of the multi-leaf collimator (MLC) on the γ-pass rate of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC).Methods:A total of 60 VMAT plans for NPC were selected to measure the γ-pass rate. The MLC data across all control points (CPs) in each VMAT plan were analyzed to calculate the mean field area (MFA), average leaf gap (ALG), small aperture score (SAS), and their corresponding weighted metrics including MFAW, ALGW, and SASW, considering dose weight (W). Pearson′s bivariate correlation analysis was conducted to examine the correlations between MLC complexity metrics and the γ-pass rate. Moreover, the receiver operating characteristic (ROC) analysis was employed to assess the predictive efficacy of MLC complexity metrics on dose verification result.Results:Under the 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria, the MFA in the 60 VMAT plans exhibited a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.72, P<0.05), and the MFAW was also positively correlated with the γ-pass rate ( r=0.83, 0.81, 0.75, P<0.05). The ALG manifested a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.74, P<0.05), as did the ALGW ( r=0.83, 0.81, 0.77, P<0.05). The SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) displayed negative correlations with the γ-pass rate ( r= -0.86, -0.82, -0.71, -0.84, -0.82, -0.72, -0.79, -0.79, -0.73, -0.30, -0.35, -0.42, P<0.05), whereas the SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) showed positive correlations with the γ-pass rate ( r=0.49, 0.45, 0.33, 0.73, 0.71, 0.59, 0.79, 0.79, 0.76, P<0.05). The outcomes of SASW reveal slightly stronger correlations than those of SAS. In terms of correlations among complexity metrics, a positive correlation was observed between MFA and ALG ( r=0.98, P<0.05). ALG was negatively correlated with SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) ( r= -0.95, -0.94, -0.89, -0.39, P<0.05), and positively correlated with SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) ( r=0.51, 0.77, 0.92, P<0.05). The weighted result mirrored these correlations. The ROC-derived analytical result indicate that MFA, MFAW, ALG, ALGW, SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), SAS(6-40 cm), SASW(0-1 cm), SASW(1-2 cm), SASW(2-3 cm), and SASW(6-40 cm) demonstrated exceptional predictive efficacy for dose verification result [Area under the curve (AUC) > 0.9, P<0.05]. Conclusions:The γ-pass rate of VMAT plans for NPC is strongly correlated with MLC complexity metrics, which demonstrate excellent predictive efficacy for dose verification result. The increased uncertainty in dose calculations and measurements caused by narrow fields generated by the MLC is a significant factor contributing to the reduced γ-pass rate of VMAT plans. This finding is associated with discrepancies in the precision of treatment planning system (TPS) modeling and the accuracy of dose verification tools, providing a reference for similar challenges.
4.A comparative study of radiotherapy using three distinct radiotherapy techniques following immediate breast reconstruction for breast cancer
Xiantao HE ; Zhuohua XU ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):317-324
Objective:To investigate the differences in dosimetric parameters for target volumes and organs at risk (OARs), radiation doses to reconstructed tissues, and beam-on time in radiotherapy among helical tomotherapy (HT), volumetric modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (F_IMRT) following immediate breast reconstruction for breast cancer, thereby providing a reference for the selection of clinical radiotherapy techniques.Methods:This study retrospectively investigated 15 breast cancer patients who underwent radiotherapy following modified radical mastectomy and immediate breast reconstruction at the Liuzhou Worker′s Hospital from August 2018 to July 2023. During target volume delineation, precautions were taken to avoid the reconstructed tissues, which were delineated separately. Customized HT, VMAT, and F_IMRT treatment plans were designed for each patient. The plans were categorized into the HT, VMAT, and F_IMRT groups based on different radiotherapy techniques employed. They were comparatively analyzed through one-way analysis of variance (ANOVA), with multiple comparisons further conducted in the case of significant differences.Results:Statistical analyses reveal significant differences in various parameters of target volumes among the three groups of plans ( F = 38.73, 14.95, 37.01, 48.05, 35.55, 22.56, 34.30, P < 0.05). Pairwise comparisons indicate that the maximum dose ( D2%), minimum dose ( D98%), mean dose ( Dmean), and the proportion of high-dose volumes within the target volume ( V107%and V110%) in both the HT and VMAT groups were significantly better than those in the F_IMRT group. The HT group demonstrated the optimal conformity index (CI), while the VMAT group displayed the superior homogeneity index (HI) compared to the other two groups. In terms of OAR, the V20 of the ipsilateral lung was the lowest in the HT group ( F = 14.31, P < 0.05) and the highest in the F_IMRT group ( F = 14.31, P < 0.05). However, the V5 and Dmean for both the ipsilateral and contralateral lungs in the HT group significantly surpassed those of the other groups ( F = 39.16, 31.91, P < 0.05). The mean dose Dmean ( F = 5.57, P < 0.05) of the contralateral breast was significantly reduced in the VMAT group compared to the other two groups. No statistically significant differences were observed for other OARs, including the heart, spinal cord PRV, thyroid, and humeral head ( P > 0.05). The radiation doses to reconstructed tissues ( Dmax, V53.5, Dmean) ascended in the order of HT, VMAT, and F_IMRT groups ( F = 17.69, 17.53, 15.11, P < 0.05). The HT and F_IMRT groups showed similar beam-on times ( P > 0.05), both exceeding that of the VMAT group by several folds ( F = 28.72, P < 0.05). Conclusions:The comparative analysis indicates that the three radiotherapy techniques exhibit distinct advantages and limitations, with F_IMRT demonstrating the least comprehensive advantage. HT can enhance the conformity of target volumes while reducing the overall radiation doses to reconstructed tissues and the crucial indicator V20 in the ipsilateral lung. VMAT demonstrates the highest treatment efficiency, yielding improved dose uniformity in the target volume and reduced radiation doses to the contralateral breast. It is advisable to prioritize HT or VMAT based on actual clinical conditions.
5.Reconstruction points of intrauterine applicator in intracavitary brachytherapy for cervical cancer
Yongfu FENG ; Shaojun CHEN ; Yusong LONG ; Junwen TAN ; Xiantao HE ; Gang LI ; Chengjun FENG ; Zhanyu WANG
Chinese Journal of Radiation Oncology 2024;33(9):825-832
Objective:To evaluate the effect of different reconstruction points of intrauterine applicator on the source dwell positions and plan dosimetry in intracavitary brachytherapy for cervical cancer.Methods:Clinical data of 43 patients with cervical cancer who had completed radical radiotherapy in Liuzhou Workers' Hospital from May 2020 to October 2022 were retrospectively analyzed. Among 43 patients, aged 32-79 years, 40 cases were diagnosed with squamous carcinoma and 3 cases of adenocarcinoma. All patients received external irradiation for 50.4 Gy / 28 fractions and CT-guided intracavitary brachytherapy (45° intrauterine applicator) was 36 Gy / 6 fractions. Brachytherapy was performed by using Fletcher applicator, the curvature of intrauterine applicator were 15°, 30°and45°. Two sets of brachytherapy plans were simulated for each patient. One set of plans extracted the simulated CT positioning images and the original plan of the patient's brachytherapy. The reconstruction point of the curved part of the 45° intrauterine applicator was adjusted to slice-by-slice reconstruction. The plan was optimized to meet clinical requirements according to the prescription, which was called the slice-by-slice group. In the other set of plans, slice-by-slice group was used as a template. The reconstruction points of the curved section of the 45° intrauterine applicator were adjusted to 1, 3, 5, and 7, without modifying the applicator weights and other parameters, which was called the average group 1, 3, 5 and 7. The deviation analysis of 15°, 30° and 45° intrauterine applicator with different number of reconstruction points was carried out, the reconstruction deviation of 45°, 30° and 15° intrauterine applicator at different reconstruction points was compared. Paired-sample t-test or Wilcoxon signed rank test were used to compare the differences in high-risk clinical target volume (HR-CTV) D 50%, D 90%, D 100%, V 100%, V 150%, V 200% and conformity index (CI) as well as D 2 cm3, D 1 cm3 and D 0.1 cm3 in bladder, rectum, and small intestine between two groups of 45° intrauterine applicator. Results:The reconstruction deviation in the average group was mainly from the vertical direction of the 45° intrauterine applicator. The mean reconstruction deviations of 45° (1, 3, 5, 7 reconstruction points), 30° (1, 3, 5 reconstruction points) and 15° (1, 2 reconstruction points) were 1.30 mm, 0.32 mm, 0.14 mm and 0.08 mm; 0.57 mm, 0.14 mm and 0.06 mm; 0.14 mm and 0.06 mm, respectively. There was no significant difference in the parameters of high-risk clinical target volume (HR-CTV) in the slice-by-slice group compared with the average group 5 and 7 (all P>0.005), and no significant difference was found between the average group 5 and 7 (all P>0.005). There were no statistically significant differences in bladder and rectum doses between the slice-by-slice group and the average groups or within the average groups (all P>0.005). The parameters of small intestine in the slice-by-slice group were higher than those of the average group 1, the difference was statistically significant ( P=0.002,<0.001,<0.001). The dose of small intestine in the slice-by-slice group was not statistically significant compared with those in the average group 5 and 7 (both P>0.005). The dose of small intestine in the average group 5 was not statistically significant compared with that in the average group 7 ( P>0.005). The small intestine dose deviations of D 0.1 cm3, D 1 cm3 and D 2 cm3 in the average groups at 1 reconstruction point were 2.41%±1.70%, 1.95%±1.27% and 1.71%±1.10%, respectively. Conclusion:The number of reconstruction points is recommended to be no less than 1, 3 and 5 of the curved part of the 15°, 30°and 45° Fletcher intrauterine applicator, respectively, during intracavitary brachytherapy for cervical cancer.
6.Correlation between monitor units and pass rate of plan dose verification in VMAT plan for different cancers
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Zhanyu WANG
Chinese Journal of Radiation Oncology 2023;32(6):546-550
Objective:To analyze the correlation between the monitor units and pass rate of plan dose verification in the volumetric intensity modulated arc therapy (VMAT) plan.Methods:VMAT plans for 20 patients with nasopharyngeal carcinoma (NPC) and 30 patients with cervical cancer who underwent radiotherapy at Liuzhou Workers' Hospital from January to October 2020 were retrospectively chosen. The Detector 1500 array and Octavius 4D phantom from German PTW company were used for dose measurement. The pass rates of dose verification of relevant plans were analyzed under the conditions of 3%/2 mm and 2%/2 mm. The correlation between the monitor units and pass rate of plan dose verification in VMAT plans was assessed by Pearson's bivariate correlation analysis.Results:Under the condition of 3%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.873 ( P<0.001), -0.800 ( P<0.001), -0.781 ( P<0.001), -0.493 ( P=0.006) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Under the condition of 2%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.842 ( P<0.001), -0.770 ( P<0.001), -0.748 ( P<0.001) and -0.531 ( P=0.003) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Conclusion:Significant negative correlation can be observed between the monitor units and plan dose verification pass rate in VMAT plan.
7.Clinical value of helium-free magnetocardiography in diagnosis of coronary heart disease
Feng XU ; Chenchen TU ; Shuwen YANG ; Ming DING ; Bin CAI ; Huan ZHANG ; Linqi LIU ; Xueyao YANG ; Shu ZHOU ; Zhao MA ; Xiantao SONG ; Hongjia ZHANG
Chinese Journal of General Practitioners 2023;22(11):1159-1166
Objective:To assess the clinical value of helium-free magnetocardiography(MCG) in the diagnosis of coronary artery disease(CAD).Methods:A total of 213 patients with suspected CAD undergoing MCG in Beijing Anzhen Hospital were enrolled in the study. All patients underwent coronary CT angiography/invasive coronary angiography(CCTA/ICA) within 48 hours after MCG scanning. The parameters of MCG, including magnetic field multipolarization, magnetic field unipolarization, T-wave flattened, change in magnetic field distribution at TT segment, abnormal T-peak amplitude ration of maximum to minimum, significant movement of poles, magnetic field angle deviation and abnormal distribution of positive pole were used for the evaluation of the stenosis of coronary arteries.Results:Among 213 patients, MCG scanning was completed in 193 cases(90.6%), while 20 cases were excluded for various reasons. The CCTA/ICA results were taken as gold standard, the total coincidence rate of MCG with the degree of stenosis was 88.60%(95% CI: 83.25%-92.72%), the sensitivity and specificity of MCG in the diagnosis of CAD was 89.63%(95% CI: 83.21%-94.21%) and 88.23%(95% CI:78.12%-94.78%), respectively; the positive and negative predictive value were 93.80%(95% CI:88.72%-96.68%) and 81.08%(95% CI:72.15%-87.64%), respectively. Conclusion:MCG is highly accurate in the diagnosis of CAD, it may be widely used clinically as an non-invasive method free of radiation or contrast agent.
8.Short-term outcome of ascending aorta replacement combined with total aortic arch fenestration technique for acute type A aortic dissection
Xiantao MA ; Zhangqiang ZHU ; Yi FENG ; Shiliang LI ; Akilu Wajeehullahi ; Xiang WEI ; Cai CHENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(05):577-584
Objective To report our clinical experience and outcomes of thoracic endovascular aortic repair (TEVAR) for acute Stanford type A dissection using ascending aorta replacement combined with implantation of a fenestrated stent-graft of the entire aortic arch through a minimally invasive technique. Methods From 2016 to 2020 in our hospital, 24 patients (17 males and 7 females, aged 45-72 years) with complicated Stanford type A aortic dissection, underwent replacement of the proximal ascending aorta with TEVAR. None of the patients with dissection involved the three branches of the superior arch, and all patients were replaced with artificial blood vessels of the ascending aorta under non-hypothermic cardiopulmonary bypass, preserving the arch and the three branches above the arch, and individualized stent graft fenestration. Results Surgical technical success rate was 100.0%. There was no intraoperative complication or evidence of endo-leak in 1 month postoperatively. Hospital stay was 10±5 d. During postoperative follow-up, the stent was unobstructed without displacement, the preserved branch of the aortic arch was unobstructed, and the true lumen of the descending aorta was enlarged. Conclusion This hybrid technique by using TEVAR with fenestrated treatment is a minimally invasive and effective method to treat high-risk patients with acute Stanford type A aortic dissection.
9.Application of helical tomotherapy in the treatment of synchronous bilateral breast cancer
Xiantao HE ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2022;42(12):943-949
Objective:To study the differences in the dosimetry and delivery time between helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) in postoperative radiotherapy of synchronous bilateral breast cancer (SBBC) and to explore the feasibility of clinical application of the HT technology.Methods:A retrospective analysis was conducted for nine SBBC patients who underwent modified radical postoperative radiotherapy in the Fourth Affiliated Hospital of Guangxi Medical University from February 2017 to May 2022. For each patient, the Precision planning system was used to formulate the HT plan, and the RayStation planning system was employed to develop the VMAT plan. All plans obtained were divided into HT group and VMAT group according to plan type. The paired sample t-test was used to compare the dosimetric parameters of the target volume and organ at risk (OAR) and delivery time between the two radiotherapy technologies. Results:The plans of both groups could meet the clinical treatment requirements. The coverage ( D95% and V100%), conformity index (CI), average dose ( Dmean), and median dose ( D50%) of the target volumes in the HT group were better than those in the VMAT group, and the differences were statistically significant ( t=-3.21, -3.39, -5.03, 3.76, 4.97, P < 0.05). The differences in the maximum dose ( D2%), minimum dose ( D98%), high dose volumes ( V107% and V110%), and homogeneity index (HI) of the target volumes between the two groups were not statistically significant ( P > 0.05). Regarding the OAR, the V20 and Dmean of both lungs in the HT group were significantly lower than those in the VMAT group, but the irradiation volume V5 of both lungs in the HT group was significantly higher than that in the VMAT group ( t=-3.01, 3.83, -2.81, P < 0.05). Moreover, V20, V30, V40, and Dmean of heart and the V20 and Dmean of liver in the HT group were significantly lower than those in the VMAT group, with statistically significant differences ( t=3.76, -2.83, -2.74, 5.93, 4.57, 4.48, P < 0.05). There was no significant difference in the radiation doses to other OARs (spinal cord, thyroid gland, and humerus head, P > 0.05). The delivery time of the HT group was significantly higher than that of the VMAT group ( t = 11.32, P < 0.05). Conclusions:Compared with VMAT, HT has greater dosimetric advantages, and can provide higher target coverage, conformability and average dose, and significantly reduce the overall radiation doses to both lungs, heart, and liver in OARs. However, the irradiation volume V5 at low-dose areas of both lungs and the delivery time in the HT group are higher than those in the VMAT group, but still meet the clinical treatment requirements. Therefore, it is feasible to apply the HT technology to the modified radical postoperative radiotherapy of SBBC.
10.Construction of controllable polyethylene glycol bioactive coating with hemocompatibility from the surface of modified glass substrate.
Yu WEI ; Jingxun ZHANG ; Yuzhong ZHANG ; Xiantao FENG ; Xuanhuang YANG
Journal of Biomedical Engineering 2019;36(2):260-266
A diblock copolymer, poly(ethylene glycol) methacrylate-block-glycidyl methacrylate (PEGMA-GMA), was prepared on glass substrate by surface-initiated atom transfer radical polymerization (SI-ATRP), and endothelial specific peptide Arg-Glu-Asp-Val (REDV) was immobilized at the end of the PEGMA-GMA polymer brush by ring opening reaction through the rich epoxy groups in the GMA. The structure and hydrophilicity of the polymer brushes were characterized by static water contact angle, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The results showed that the REDV modified copolymer brushes were successfully constructed on the glass substrates. The REDV peptide immobilized onto surface was quantitatively characterized by ultraviolet-visible spectroscopy (UV-VIS). The blood compatibility of the coating was characterized by recalcification time and platelet adhesion assay. The results showed that the polymer coating had good blood compatibility. The multifunctional active polymer coating with PEGMA and peptide produced an excellent prospect in surface construction with endothelial cells selectivity.
Biocompatible Materials
;
Cells, Cultured
;
Endothelial Cells
;
Glass
;
Humans
;
Immobilized Proteins
;
Methacrylates
;
Oligopeptides
;
Platelet Adhesiveness
;
Polyethylene Glycols
;
Polymers
;
Surface Properties

Result Analysis
Print
Save
E-mail