1.Analysis of risk factors for cardiovascular events and construction of a nomogram prediction model in patients undergoing long-term peritoneal dialysis
Xinyuan ZHOU ; Yuxin JIANG ; Xiaoxia WANG ; Xiangjie YANG ; Runzhe ZHOU ; Yuqing MENG ; Dingxin ZHANG ; Jin ZHANG ; Ying WANG
Acta Universitatis Medicinalis Anhui 2026;61(4):748-757
ObjectiveTo analyze the risk factors for long-term cardiovascular events in patients undergoing long-term peritoneal dialysis (PD), and to construct and validate a visual nomogram prediction model based on multiple parameters. MethodsA prospective cohort study was conducted, consecutively enrolling 248 maintenance PD patients (dialysis duration ≥ 3 months). Demographic characteristics, clinical indicators, laboratory parameters, and echocardiographic indices (including left ventricular ejection fraction [LVEF], ratio of early diastolic mitral inflow velocity to early diastolic mitral annular velocity (E/e’), etc.) were collected. The composite endpoint was defined as the occurrence of cardiovascular events or cardiovascular death, with non-cardiovascular death as the competing risk and loss to follow-up or the end of follow-up as censoring events. Fine-Gray competing risks model was used to screen independent predictors, based on which a nomogram model was constructed. Internal validation was performed using the Bootstrap method (1 000 resamplings), and the concordance index (C-index) and time-dependent receiver operating characteristic (time-dependent ROC) curve were calculated to evaluate the model performance. ResultsWith a median follow-up of 29 months (interquartile range: 24–35 months), 88 patients (35.48%) reached the composite endpoint, including 80 cases of cardiovascular events and 8 cases of cardiovascular death, and 4 patients died of non-cardiovascular causes. Multivariate Fine-Gray analysis revealed that age, diabetes mellitus, hemoglobin (HGB) level and E/e' ratio were independent influencing factors of the composite endpoint. Specifically, each 1-year increase in age was associated with a 3.0% increase in the risk of the composite endpoint (HR=1.030, P=0.006); patients with diabetes mellitus had a 167.9% higher risk compared with non-diabetic patients (HR=2.679, P=0.007); each 1g/L increase in HGB level contributed to a 1.5% reduction in the risk (HR=0.985, P=0.003); and each 0.1 increase in E/e' ratio led to a 7.2% increase in the risk (HR=1.072, P=0.045). The nomogram model had a C-index of 0.76 (95% CI: 0.698–0.820), and the AUC of the time-dependent ROC curve reached 0.849 at 23 months of follow-up. ConclusionIncreased age, complicated with diabetes mellitus, decreased HGB, and elevated E/e' ratio are independent risk factors of long-term occurrence of cardiovascular events and cardiovascular death in patients undergoing long-term PD. The nomogram model constructed based on the above variables has good predictive value and clinical applicability, which can provide a reference for cardiovascular risk stratification and individualized intervention in long-term PD patients.
2.Hemodynamic Analysis of Autologous Arteriovenous Fistula Based on Fluid-Structure Interaction Simulation
Fan WANG ; Jinfeng GUO ; Cheng ZHANG ; Ruixin GUO ; Weina MU ; Xiangjie KONG
Journal of Medical Biomechanics 2025;40(5):1248-1255
Objective To study the hemodynamic characteristics of autologous arteriovenous fistula(AVF)and provide a theoretical basis for reducing its stenosis rate.Methods Bidirectional fluid-structure interaction(FSI)simulations were conducted on a modified AVF model.Flow field and wall shear stress(WSS)distributions in the internal fistula at different periods and angles in a cardiac cycle were analyzed for retrograde flow(confluence)and anterograde flow(shunt)modes in models with varying anastomosis angles.Results Under confluence modes,the WSS<1 Pa area in the 60° anastomosis angle model was the smallest(7.027 mm2),while the 45°,60°,and 90° models showed no significant differences in eddy current size and intensity.Under shunt modes,the 45° anastomosis angle model had the smallest WSS<1 Pa area(9.079 mm2),but the 60° model exhibited the lowest eddy current intensity and distribution area.In addition,the difference in the WSS<1 Pa area between the 60° and 45° models was only 2.661 mm2.Conclusions Under both confluence and shunt flow modes,establishing an AVF with 60° anastomosis angle is conducive to reducing the risk of vascular stenosis in arteriovenous fistula.
3.Pathogen genome databases development and application in public health
Ziquan LYU ; Yanbo YANG ; Yu ZHANG ; Xiangjie YAO ; Xuemei LU ; Yulin FU ; Xiran WANG ; Qinghua HU ; Xuan ZOU
Chinese Journal of Epidemiology 2025;46(9):1697-1703
Infectious diseases continue to pose a threat to global public health. Successive global shocks caused by emerging and re-emerging pathogens have continuously challenged existing surveillance systems, highlighting the urgent need to build efficient and precise pathogen surveillance networks. Pathogen genomic databases have been developed rapidly in recent two decades, significantly improving the molecular identification, evolutionary analysis, and transmission tracking of pathogens, and changing disease surveillance strategies and patterns. This paper summarizes the developmental history and current state of pathogen genomic databases, and discusses their applications in public health, including pathogen variation surveillance, emerging or suspected pathogen identification, and epidemiological tracing. Furthermore, this paper systematically analyzes the limitations and key challenges faced by current global health prevention and control system, and suggests the focus of the development of online pathogen databases to address existing shortcomings, ultimately improve global infectious disease surveillance and early warning
4.Pathogen genome databases development and application in public health
Ziquan LYU ; Yanbo YANG ; Yu ZHANG ; Xiangjie YAO ; Xuemei LU ; Yulin FU ; Xiran WANG ; Qinghua HU ; Xuan ZOU
Chinese Journal of Epidemiology 2025;46(9):1697-1703
Infectious diseases continue to pose a threat to global public health. Successive global shocks caused by emerging and re-emerging pathogens have continuously challenged existing surveillance systems, highlighting the urgent need to build efficient and precise pathogen surveillance networks. Pathogen genomic databases have been developed rapidly in recent two decades, significantly improving the molecular identification, evolutionary analysis, and transmission tracking of pathogens, and changing disease surveillance strategies and patterns. This paper summarizes the developmental history and current state of pathogen genomic databases, and discusses their applications in public health, including pathogen variation surveillance, emerging or suspected pathogen identification, and epidemiological tracing. Furthermore, this paper systematically analyzes the limitations and key challenges faced by current global health prevention and control system, and suggests the focus of the development of online pathogen databases to address existing shortcomings, ultimately improve global infectious disease surveillance and early warning
5.Hemodynamic Analysis of Autologous Arteriovenous Fistula Based on Fluid-Structure Interaction Simulation
Fan WANG ; Jinfeng GUO ; Cheng ZHANG ; Ruixin GUO ; Weina MU ; Xiangjie KONG
Journal of Medical Biomechanics 2025;40(5):1248-1255
Objective To study the hemodynamic characteristics of autologous arteriovenous fistula(AVF)and provide a theoretical basis for reducing its stenosis rate.Methods Bidirectional fluid-structure interaction(FSI)simulations were conducted on a modified AVF model.Flow field and wall shear stress(WSS)distributions in the internal fistula at different periods and angles in a cardiac cycle were analyzed for retrograde flow(confluence)and anterograde flow(shunt)modes in models with varying anastomosis angles.Results Under confluence modes,the WSS<1 Pa area in the 60° anastomosis angle model was the smallest(7.027 mm2),while the 45°,60°,and 90° models showed no significant differences in eddy current size and intensity.Under shunt modes,the 45° anastomosis angle model had the smallest WSS<1 Pa area(9.079 mm2),but the 60° model exhibited the lowest eddy current intensity and distribution area.In addition,the difference in the WSS<1 Pa area between the 60° and 45° models was only 2.661 mm2.Conclusions Under both confluence and shunt flow modes,establishing an AVF with 60° anastomosis angle is conducive to reducing the risk of vascular stenosis in arteriovenous fistula.
6.Epidemic characteristics and disease burden of drug-resistant tuberculosis cases in the elderly in Wuhan
Liping ZHANG ; Xiangjie LIU ; Xiaoxia LIU ; Ting WEI ; Yan WANG ; Qian LI
Journal of Clinical Medicine in Practice 2025;29(6):30-33
Objective To analyze the epidemiological characteristics and disease burden of drug-resistant tuberculosis cases among elderly patients in Wuhan.Methods Clinical data of elderly pa-tients with pulmonary tuberculosis in Wuhan from January 2019 to December 2022 were retrospectively analyzed.Sputum samples were collected for Mycobacterium tuberculosis isolation,and drug suscepti-bility testing was performed using the proportion method.The epidemiological characteristics of drug-resistant tuberculosis and the direct economic burden of the patients were analyzed.Results A total of 972 elderly patients with positive Mycobacterium tuberculosis tests were included.The overall tuberculosis drug resistance rate was 21.19%(206/972).Male,rural residence,lower education level(primary school or below)and retreatment history significantly increased the risk of developing drug-resistant tu-berculosis(P<0.05).The direct economic burden for elderly patients with drug-resistant tuberculosis was 24,101.52(8,283.98,39,598.89)RMB,and the indirect economic burden was 1,858.64(528.66,3,085.26)RMB.Conclusion The incidence of drug resistance in elderly tuberculosis is high,and male,rural residence,low education level and tuberculosis retreatment are the risk factors for drug resistance in elderly tuberculosis,and their economic burden is heavy after drug resistance.
7.Analysis on consistency between actual measured dose and displayed dose in CT examination on head of children
Yu ZHANG ; Xiangjie MA ; Zhuo HUANG
China Medical Equipment 2025;22(6):19-23
Objective:To assess the consistency between displayed doses and actual doses of the computed tomography(CT)equipment of different manufactories and types through compares the actual measured dose and the displayed dose in CT examination on head of children,so as to provide references for rapid estimation and scientific assessment for the dose in CT examination on head of children.Methods:The CT equipment of two kinds of commonly used brands were selected,which included Brand A(imported equipment,16-slice and 64-slice)and Brand B(domestic equipment,16-slice and 32-slice).A pediatric head phantom was used to conduct scan according to pre-set scan protocol for children at different ages.A ionization chamber that like a pen was adopted to measure CT dose index(CTDI)values of scanning the head of children under various scan parameters,which were compared with the displayed values in equipment.Results:For 16-slices CT of Brand A,the ratio range of actually measured dose to displayed dose was between 1.08 and 1.10.For the 64-slices CT of Brand A,that was between 1.11 and 1.17.For the 16-slices CT of Brand B,that was between 1.00 to 1.04.For the 32-slices CT of Brand B,that was between 1.12 to 1.21.All ratios were slightly higher than 1,but were within a relatively concentrated range.Under the products of different tube voltages(kV)and tube current-time(mAs),the volatility of ratio range of actually measured dose to displayed dose of different ages was less than 5%,which indicated the deviations were stable,and the influence of parameters was less.Conclusion:In CT examinations on head of children,the consistency of the ratio value between actually measured value and displayed value is higher under the acquiescent scan conditions of the scan protocol for head of children at different ages,which can conduct rapidly dose estimation as a certain conversion coefficient.
8.Analysis on consistency between actual measured dose and displayed dose in CT examination on head of children
Yu ZHANG ; Xiangjie MA ; Zhuo HUANG
China Medical Equipment 2025;22(6):19-23
Objective:To assess the consistency between displayed doses and actual doses of the computed tomography(CT)equipment of different manufactories and types through compares the actual measured dose and the displayed dose in CT examination on head of children,so as to provide references for rapid estimation and scientific assessment for the dose in CT examination on head of children.Methods:The CT equipment of two kinds of commonly used brands were selected,which included Brand A(imported equipment,16-slice and 64-slice)and Brand B(domestic equipment,16-slice and 32-slice).A pediatric head phantom was used to conduct scan according to pre-set scan protocol for children at different ages.A ionization chamber that like a pen was adopted to measure CT dose index(CTDI)values of scanning the head of children under various scan parameters,which were compared with the displayed values in equipment.Results:For 16-slices CT of Brand A,the ratio range of actually measured dose to displayed dose was between 1.08 and 1.10.For the 64-slices CT of Brand A,that was between 1.11 and 1.17.For the 16-slices CT of Brand B,that was between 1.00 to 1.04.For the 32-slices CT of Brand B,that was between 1.12 to 1.21.All ratios were slightly higher than 1,but were within a relatively concentrated range.Under the products of different tube voltages(kV)and tube current-time(mAs),the volatility of ratio range of actually measured dose to displayed dose of different ages was less than 5%,which indicated the deviations were stable,and the influence of parameters was less.Conclusion:In CT examinations on head of children,the consistency of the ratio value between actually measured value and displayed value is higher under the acquiescent scan conditions of the scan protocol for head of children at different ages,which can conduct rapidly dose estimation as a certain conversion coefficient.
9.Predictive value of serum thrombospondin-1,D-dimer and tissue inhibitor of metalloproteinase-1 levels in late pregnancy for postpartum hemorrhage in re-pregnant women with scarred uterus
Xiangjie LI ; Yanfang REN ; Yuhong WANG ; Quanhua ZHANG ; Wenli GUAN
Journal of Xinxiang Medical College 2024;41(2):138-142
Objective To investigate the predictive value of serum thrombospondin-1(THBS-1),D-dimer(D-D)and tissue inhibitor of metalloproteinase-1(TIMP-1)levels in late pregnancy for postpartum hemorrhage(PPH)in re-pregnant women with scarred uterus.Methods Totally 108 re-pregnant women with scarred uterus admitted to the First Affiliated Hospital of Xinxiang Medical University from June 2020 to August 2022 were selected and divided into the PPH group(n=21)and the non-PPH group(n=87)according to whether PPH occurred after delivery.On the day of admission,5 mL elbow venous blood was collected from re-pregnant women in the two groups,and the levels of serum THBS-1,D-D and TIMP-1 of pregnant women in the two groups were detected by enzyme-linked immunosorbent assay.The serum THBS-1,D-D TIMP-1 levels and clinical data of pregnant women between the two groups were compared.The influencing factors on the occurrence of PPH in re-pregnant women with scarred uterus were analyzed by multivariate logistic regression,and the predictive value of serum THBS-1,D-D and TIMP-1 levels on the occurrence of PPH in re-pregnant women with scarred uterus was evaluated by receiver operating characteristic curve.Results The percentage of patients with ≥ 2 induced abortions,placental abruption,uterine incision laceration,uterine inertia or scar thickness<0.3 cm,as well as serum THBS-1 and D-D levels in late pregnancy in the PPH group were significantly higher than those in the non-PPH group,and serum TIMP-1 level in late pregnancy were significantly lower than that in the non-PPH group(P<0.05).The uterine inertia,as well as high D-D and THBS-1 levels,were independent risk factors for PPH in re-pregnant women with scarred uterus(P<0.05),and low TIMP-1 level was a protective factor(P<0.05).The area under the curve of combined serum THBS-1,D-D and TIMP-1 levels to predict PPH in re-pregnant women with scarred uterus was greater than that predicted by the three factors alone(P<0.05).Conclusion Serum THBS-1,D-D and TIMP-1 levels in late pregnancy can be used as reference indicators for predicting the occurrence of PPH in re-pregnant women with scarred uterus,and the combination of the three indexes is more effective in predicting the occurrence of PPH.
10.E2E testing of Cyberknife lung tracking using a homemade lung phantom
Xiao WEI ; Xiangjie MA ; Mingsheng LI ; Zhengzhao ZHANG ; Ya LIU ; Yuze YANG ; Jinsheng CHENG
Chinese Journal of Radiological Health 2024;33(1):1-6
Objective :
To verify the feasibility of using a homemade lung phantom for quality control of Cyberknife by
comparing the measurement results of the homemade lung phantom and CIRS dynamic phantom in E2E testing of Cyberknife lung tracking.
Methods :
The patient treatment process was simulated, including CT positioning, plan design, irra-
diation implementation, film scanning, and analysis using the homemade phantom and CIRS phantom. The two phantoms
were measured five times using MLC under the S7 generation Cyberknife and five times using Iris under the M6 generation
Cyberknife. The differences in measurement results between the two phantoms were analyzed using independent sample t-test.
Results :
For the S7 generation Cyberknife, the statistical analysis of differences between the two phantoms in the detection values on the X-axis, Y-axis, Z-axis, and total deviation showed P values of 0.236, 0.175, 0.289, and 0.668, respect-
ively. For the M6 generation Cyberknife, the statistical analysis showed P values of 0.880, 0.891, 0.573, and 0.433, respect-
ively. The P values were all > 0.05. Therefore, there were no statistically significant differences in the detection results
between the homemade lung phantom and the CIRS phantom under the S7 and M6 generation Cyberknife. The total deviation values were <1.5 mm.
Conclusion
The homemade lung phantom and CIRS phantom have consistent measurement
results in the E2E testing of Cyberknife lung tracking and meet the requirements of Report of AAPM TG-135 and WS 667-
2019 standard. Therefore, the homemade lung phantom is feasible for clinical quality control of Cyberknife.