1.Transcatheter closure of atrial septal defect using fully biodegradable occluder under ultrasound guidance: A case report
Ying' ; ao ZHAO ; Yiming YAN ; Ziping LI ; Hang LI ; Fengwen ZHANG ; Fang FANG ; Guangzhi ZHAO ; Jing DONG ; Chuangshi WANG ; Jiande WANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1796-1799
Currently, transcatheter intervention is the preferred treatment for patients with anatomically suitable atrial septal defects. However, the use of nickel-titanium alloy occluders in interventional procedures results in lifelong presence of the implant in the body, leading to complications such as metal allergies and arrhythmias in some patients. To overcome the short-term and long-term complications associated with the presence of metal, and to avoid radiation exposure and metal toxicity, this paper reports a case of successful transcatheter closure of atrial septal defect in a pediatric patient with metal allergies using fully biodegradable occluder under ultrasound guidance, achieving excellent results by interventional therapy.
2.Echocardiography-guided Transcatheter Aortic Valve Replacement After Aortic Bioprosthetic Failure:a Case Report
Guangzhi ZHAO ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):290-292
This article reports a case of transcatheter aortic valve replacement guided by echocardiography only for the treatment of aortic valve bioprosthesis failure.The patient developed bioprosthesis stenosis eight years after surgical bioprosthetic aortic valve replacement and underwent successful transcatheter aortic valve-in-valve replacement under echocardiography guidance.This offers a new treatment option for valve replacement after bioprosthetic valve failure under echocardiography guidance,and demonstrates the feasibility of echocardiography-guided interventional transcatheter valve-in-valve replacement.Also,this report discusses the technique details in valve positioning,reducing the risk of complications and improving prognosis.
3.Two Cases of Transcatheter Aortic Valve Replacement Guided by Echocardiography Alone for Severe Aortic Stenosis
Shouzheng WANG ; Guangzhi ZHAO ; Xiaopeng HU ; Hao SHI ; Bo PENG ; Xu WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):284-289
Transcatheter aortic valve replacement(TAVR)has become an important therapeutic approach for severe aortic stenosis.However,complications associated with TAVR cannot be overlooked,among which contrast agents induced acute kidney injury(AKI)is a common complication.To explore methods to reduce the occurrence of AKI,this article reports two cases of successful treatment of severe aortic stenosis by TAVR under pure echocardiographic guidance,both of whom were elderly women aged 75 and 69,respectively,and both were implanted with a Evolute Pro 26 mm valve.Postoperative echocardiography showed good valve positioning and function.
4.Clinical efficacy of transcatheter edge-to-edge repair in patients with non-central degenerative mitral regurgitation
Peijian WEI ; Junke CHANG ; Jianrui MA ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shiguo LI ; Fujian DUAN ; Wenbin OUYANG ; Shouzheng WANG ; Fang FANG ; Xiangbin PAN
Chinese Journal of Cardiology 2025;53(4):373-381
Objective:To evaluate the clinical efficacy of mitral valve transcatheter edge-to-edge repair (TEER) in patients with non-central degenerative mitral regurgitation (DMR).Methods:This retrospective study included patients with non-central DMR who underwent TEER at Fuwai Hospital between January 2021 and February 2024. Patients were categorized into two groups: the commissure-involved group and the non-commissure group, based on whether the mitral valve commissures were involved. Clinical data, surgical outcomes, and echocardiographic findings at 3 months postoperatively were collected and compared, and patients were followed up. The primary endpoint was the procedural success rate at discharge.Results:A total of 59 patients were included, aged (68.6±9.3) years, including 23 females (39%). In the overall study population, 78% (46/59) of patients had severe mitral regurgitation. Forty-two cases were in the non-commissure group, and 17 cases were in the commissure-involved group. Patients in the non-commissure group mainly had lesions in the A1/P1 region, while patients in the commissure-involved group mainly had lesions in the A3/P3 region. There was no significant difference in the procedural success rate at discharge (93% vs. 88%, P=0.95) and the incidence of postoperative complications (5% vs. 6%, P=1.00) between the two groups. Two patients in the commissure-involved group experienced single leaflet device attachment, with one of them requiring conversion to surgical mitral valve surgery; In the non-commissure group, two patients experienced single-valve clamping, and one of them was converted to surgical mitral valve surgery. The follow-up time of the entire cohort was (15.5±10.3) months. In the non-commissure group, 2 patients died and 2 were readmitted. While in the commissure-involved group, no patients died and only 1 patient was readmitted. Conclusion:TEER is an effective treatment for patients with non-central DMR involving the commissures, without increasing the incidence of postoperative complications.
5.Transcatheter Closure of Patent Ductus Arteriosus With a Fully Biodegradable Occluder Under the Sole Guidance of Transthoracic Echocardiography:a Case Report
Zizheng LIU ; Ying'ao ZHAO ; Jianing CUI ; Ning ZHOU ; Jing DONG ; Fengwen ZHANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(9):919-921
This article presents the first reported successful case of patent ductus arteriosus closure using a fully biodegradable occluder under the sole guidance of transthoracic echocardiography.Compared to traditional methods that require radiation and metal occluders,this technique,which combines echocardiography guidance with biodegradable devices,reduces iatrogenic injury and procedural risks,demonstrating favorable clinical outcomes.
6.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
7.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
8.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
9.Echocardiography-guided Transcatheter Aortic Valve Replacement After Aortic Bioprosthetic Failure:a Case Report
Guangzhi ZHAO ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):290-292
This article reports a case of transcatheter aortic valve replacement guided by echocardiography only for the treatment of aortic valve bioprosthesis failure.The patient developed bioprosthesis stenosis eight years after surgical bioprosthetic aortic valve replacement and underwent successful transcatheter aortic valve-in-valve replacement under echocardiography guidance.This offers a new treatment option for valve replacement after bioprosthetic valve failure under echocardiography guidance,and demonstrates the feasibility of echocardiography-guided interventional transcatheter valve-in-valve replacement.Also,this report discusses the technique details in valve positioning,reducing the risk of complications and improving prognosis.
10.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.

Result Analysis
Print
Save
E-mail