1.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
2.Transcatheter Closure of Patent Ductus Arteriosus With a Fully Biodegradable Occluder Under the Sole Guidance of Transthoracic Echocardiography:a Case Report
Zizheng LIU ; Ying'ao ZHAO ; Jianing CUI ; Ning ZHOU ; Jing DONG ; Fengwen ZHANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(9):919-921
This article presents the first reported successful case of patent ductus arteriosus closure using a fully biodegradable occluder under the sole guidance of transthoracic echocardiography.Compared to traditional methods that require radiation and metal occluders,this technique,which combines echocardiography guidance with biodegradable devices,reduces iatrogenic injury and procedural risks,demonstrating favorable clinical outcomes.
3.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
4.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
5.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
6.Radiotherapy treatment comparison of liver SBRT between 4D-CT and deep inspiration breath hold troughmagnetic resonance imaging
Huiling YE ; Zhengchaoyi CHEN ; Yihan HUANG ; Yingjie ZHANG ; Xiangbin ZHANG ; Yuehu PU ; Renming ZHONG
The Journal of Practical Medicine 2025;41(7):1044-1049
Objective To compare the radiotherapy treatment accuracy between 4D-CT and DIBH follow-ing liver SBRT,and to illustrate the relevant factors.Methods A retrospective analysis was conducted on the clinical data of 28 liver cancer patients who underwent SBRT from November 2020 to July 2024,all of whom exhib-ited and localizedmorphological changes on magnetic resonance imaging(MRI).Among them,8 patients used DIBH,and 17 patients used 4D-CT.The areas of localized MRI-morphologic alterations(MMA)were delineated on post-therapeutic MRI.Different isodose structures were generated on the planning CT,and after performing de-formation registration based on the liver's region of interest(ROI),the most suitable isodose structure and MMA contours were compared to obtain quantitative accuracy indices.Correlations between factors such as GTV,PTV,liver volume,and volume changes,and the accuracy indices were analyzed.Results The DSC accuracy for the DIBH group was(0.66±0.17),range 0.32~0.90,while the DSC accuracy for the 4D CT group was(0.69±0.10),range 0.49~0.80.T-test analysis showed no significant statistical differences in accuracy indices between the DIBH and 4D CT groups(P<0.05).Correlation analysis revealed that,in both groups,distance-based indices(HD,MDA,3D-CoMD)were more strongly correlated with accuracy indices than conformality indices(DSC,CIMI).Conclusion There was no significant difference in treatment accuracy between the DIBH and 4D-CT groups,although the maximum accuracy in the DIBH group was higher than that in the 4D-CT group.This method can serve as an bench-markingtool for evaluating the accuracy of liver SBRT.It is recommended to prioritize the use of conformality indices,DSC and CIMI,when assessing the treatment accuracy of liver cancer SBRT using this approach.
7.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
8.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
9.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
10.Relationship between reflux laryngitis and the success rate of type Ⅰ tympanoplasty for otitis media
Jie WU ; Lingyi PENG ; Mingxing TANG ; Nan ZENG ; Lue ZHANG ; Quanming ZHANG ; Jing HU ; Shuyue GUO ; Xiangbin ZUO ; Qiong YANG
Chinese Archives of Otolaryngology-Head and Neck Surgery 2025;32(3):158-163
OBJECTIVE Aimed at investigating whether reflux pharyngitis is an independent risk factor for the failure of type Ⅰ tympanoplasty for chronic otitis media.This is achieved by analyzing the relationship between the postoperative tympanic membrane healing in patients who underwent type Ⅰ tympanoplasty and pharyngolaryngeal reflux finding score(RFS).METHODS Patients who underwent type Ⅰ tympanoplasty in the Department of Otolaryngology Head and Neck Surgery,Nanshan People's Hospital,Shenzhen,China,from January 2023 to July 2024 were retrospectively included.All the patients received preoperative perfect nasal endoscopy,laryngoscopy,evaluation by the RFS questionnaire,preoperative otoscopy for tympanoplasty,pure tone hearing threshold,and temporal bone thin-layer CT examination.Postoperative otoscopic examination was performed to observe tympanic membrane healing and followed up for 3 months.The patients were divided into surgery success group and failure group based on the criterion of whether a complete tympanic membrane was formed by endoscopic examination within 3 months.The RFS scores of the two groups were statistically analyzed.RESULTS A total of 135 patients with an average age of 44.78 years(±12.22 years)took part in this study,with 60 males and 75 females included,and 68 left ears and 67 right ears involved.There were 120 patients in the surgery success group,and 15 patients in the failure group.Statistical analysis revealed that the RFS score of the patients in the tympanoplasty failure group was remarkably higher than that of the patients in the tympanoplasty success group.Moreover,there were significantly more cases with suspected reflux pharyngitis in the surgery failure group(P=0.007).Reflux-induced tympanic membrane lesion and reperforation mostly occurred in the central part of the tympanic membrane graft.CONCLUSION Reflux pharyngitis has been implicated with tympanoplasty failure,and thus may be a causative factor.Additionally,the RFS can be used to screen patients with chronic suppurative otitis media for suspected reflux pharyngitis.Findings from this work indicate that perioperative anti-reflux therapy,combined with dietary and lifestyle counselling for the patients who suffer from reflux pharyngitis and are about to undergo the tympanoplasty surgery may improve surgical success rate.

Result Analysis
Print
Save
E-mail