1.Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report
Jianbin GAO ; Jian LI ; Yu YANG ; Mier MA ; Kairui YANG ; Wei LUO ; Ning WANG ; Da ZHU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):163-166
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
2.Experimental study on the ultrasound visibility of a novel interventional catheter and delivery system: In vitro and animal experiments
Ziping LI ; Wenbin OUYANG ; Zizheng LIU ; Ning ZHOU ; Jie DONG ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):784-790
Objective To assess the echogenicity of the ultrasound-guided catheter and its associated delivery system. Methods The study consisted of in vitro characterization experiments and animal studies. In the in vitro phase, the acoustic and mechanical properties of the ultrasound-guided catheter were compared with those of the traditional MPA2 catheter, including parameters such as echo intensity, recognizability, and angle dependence. In the animal experiments, a ventricular septal defect (VSD) model was established in miniature pigs to compare the procedural performance of the ultrasound-guided delivery system versus the conventional system. Evaluation indicators included the time required for the system to cross the VSD, the detection rate of the system within the right ventricle, and the occurrence of intraoperative complications. Results The ultrasound-guided catheter demonstrated a significantly higher mean echo intensity than the MPA2 catheter [(237.3±1.8) dB vs. (190.9±13.1) dB, P<0.001] and a markedly improved recognizability rate (82.3%±5.6% vs. 26.7%±3.2%, P<0.001), along with better angle independence and image quality. In animal experiments, the ultrasound-guided delivery system significantly reduced the time required to cross the VSD [(18.5±5.7) min vs. (30.3±4.5) min, P<0.001] and substantially increased the detection rate within the right ventricle (100.0% vs. 30.0%). No severe complications occurred in any experimental animal. Conclusion The ultrasound-guided catheter and its corresponding delivery system exhibite superior ultrasound visibility and operational performance in both in vitro and animal experiments, indicating strong potential for clinical application.
3.Biomechanical characteristics of walking in patients with idiopathic scoliosis:cross-sectional analysis of three-dimensional motion capture
Yanyun GOU ; Meijin HOU ; Zheng JIANG ; Shaoqing CHEN ; Xiang CHEN ; Yuzhan GAO ; Xiangbin WANG
Chinese Journal of Tissue Engineering Research 2025;29(3):471-477
BACKGROUND:The biomechanical analysis of scoliosis cases is limited,with only independent analysis focusing on the spine or lower limbs,thus lacking a comprehensive evaluation of the multidimensional body.As a result,it becomes challenging to reflect the movement relationship between the trunk and lower limbs during daily activities,which hinders comprehensive clinical treatment guidance. OBJECTIVE:To explore the relationship between different segments of the spine and the kinematics/kinetics of the lower limbs during gait activities by measuring spinal kinematics in scoliosis patients,to provide a comprehensive and multi-level assessment of the biomechanical differences between scoliosis patients and the normal population,consequently offering evidence-based guidance for the prevention and treatment of scoliosis. METHODS:A cross-sectional study was conducted from July 2020 to June 2021 at the Rehabilitation Hospital Affiliated to Fujian University of Traditional Chinese Medicine in Fuzhou University City.A total of 28 scoliosis patients and 28 normal individuals in the same age group were included.Three-dimensional motion capture system was used to capture gait kinematic data at a sampling frequency of 100 Hz.Two force plates(AMTI 400600,sampling frequency 1 500 Hz)were embedded in a 10-meter-long 2.4-meter-wide level ground walkway(with an effective data collection length of 4 m)to collect kinetic data.The differences in spatial-temporal parameters,kinematics,and kinetics of gait between the two groups were compared.Immediately after inclusion,all subjects underwent full spinal X-ray measurements to compare the differences between the scoliosis and normal groups. RESULTS AND CONCLUSION:(1)Patients with scoliosis exhibited reduced relative rotational range of motion between the shoulder and trunk,as well as between the thorax and pelvis,compared to the normal group(P<0.05).However,the rotational range of motion in the pelvis was larger in patients with scoliosis compared to the normal group(P<0.05).(2)Patients with scoliosis showed decreased range of motion in the hip and knee joints,as well as reduced peak torque in hip joint flexion and extension,and lower peak values of ground reaction forces in the concave and convex directions,in comparison to the normal group(P<0.05).(3)Patients with scoliosis demonstrated greater asymmetry indices in knee joint range of motion,relative rotational range of motion between the shoulder and trunk,and between the thorax and pelvis,when compared to the normal group(P<0.05).(4)These findings illustrate a rigid movement pattern among the shoulder,thorax,and pelvis in patients with scoliosis during level walking.There is a reduction in range of motion in the hip and knee joints,as well as decreased peak torque values in hip joint flexion and extension,and ground reaction forces in the concave and convex directions.These characteristics can serve as foundational elements for assessing rehabilitation and developing treatment plans.
4.Influence of probiotic-assisted conventional treatment on blood glucose homeostasis and neurological function in patients with type 2 diabetes mellitus complicated with stroke
Xiaowei MA ; Lizhe WANG ; Xiangbin WANG ; Wenxia FENG
Journal of Clinical Medicine in Practice 2025;29(12):71-76
Objective To explore the effects of probiotic-assisted conventional treatment on in-testinal flora,blood glucose homeostasis and neurological function in patients with type 2 diabetes mellitus complicated with stroke.Methods A total of 93 patients with type 2 diabetes mellitus com-plicated by stroke were selected as the study subjects and randomly divided into control group(n=46)and experimental group(n=47)using random number table method.The control group received conventional therapy,while the experimental group received probiotics(oral Bifidobacterium,Lacto-bacillus,and Enterococcus triple viable tablets,4 tablets/time,twice daily)in addition to convention-al therapy.Both groups were treated continuously for 7 days.The intestinal flora(counts of Bifidobacterium,Lactobacillus and Bacteroides),inflammatory markers[tumor necrosis factor-α(TNF-α),interleukin-6(IL-6),and high-sensitivity C-reactive protein(hs-CRP)],glycemic pa-rameters[fasting blood glucose(FBG),glycosylated hemoglobin(HbA1c),largest amplitude of glycemic excursions(LAGE),average blood glucose(BGL-ave),standard deviation of mean blood glucose(BGL-sd),and coefficient of variation of blood glucose(BG-cv)],and neurological function[National Institutes of Health Stroke Scale(NIHSS)score,improvement rate of neurological func-tion,proportion of patients with modified Rankin Scale(mRS)score ≤ 3,and Loewenstein Occupa-tional Therapy Cognitive Assessment(LOTCA)score]were compared between the two groups after treatment.Results After treatment,the counts of intestinal flora(Bifidobacterium,Lactobacillus,and Bacteroides)in both groups were higher than those before treatment,and the counts in the ex-perimental group were higher than those in the control group,with statistically significant differences(P<0.05).The levels of TNF-α,IL-6 and hs-CRP in both groups were lower than those before treatment,and the levels in the experimental group were lower than those in the control group,with statistically significant differences(P<0.05).The levels of FBG and HbA1c in both groups were lower than those before treatment.The FBG level,LAGE,BGL-sd,and BG-cv in the experimental group were lower than those in the control group,with statistically significant differences(P<0.05),but there were no statistically significant differences in HbA1c and BGL-ave between the two groups(P>0.05).After treatment,the NIHSS score in the experimental group was lower than that in the control group,while the LOTCA score and improvement rate of neurological function were higher than those in the control group,with statistically significant differences(P<0.05).There was no statistically significant difference in the proportion of patients with an mRS score ≤3 between the two groups(P>0.05).Conclusion Probiotic-assisted conventional treatment can regulate the number of intestinal flora in patients with type 2 diabetes mellitus complicated with stroke,relieve inflammatory responses,stabilize blood sugar levels,and improve neurological function.
5.Two Cases of Transcatheter Aortic Valve Replacement Guided by Echocardiography Alone for Severe Aortic Stenosis
Shouzheng WANG ; Guangzhi ZHAO ; Xiaopeng HU ; Hao SHI ; Bo PENG ; Xu WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):284-289
Transcatheter aortic valve replacement(TAVR)has become an important therapeutic approach for severe aortic stenosis.However,complications associated with TAVR cannot be overlooked,among which contrast agents induced acute kidney injury(AKI)is a common complication.To explore methods to reduce the occurrence of AKI,this article reports two cases of successful treatment of severe aortic stenosis by TAVR under pure echocardiographic guidance,both of whom were elderly women aged 75 and 69,respectively,and both were implanted with a Evolute Pro 26 mm valve.Postoperative echocardiography showed good valve positioning and function.
6.piR-7472 affects the mechanism by which voltage-regulated potassium channels promote osteogenic differentiation in mice
Yubin LONG ; Xiangbin WANG ; Jigeng FAN ; Houzhi YANG ; Yang YANG ; Yong LI
Chinese Journal of Tissue Engineering Research 2025;29(14):2868-2874
BACKGROUND:Existing studies have made significant progress in PIWI-interacting RNAs(piRNAs)against osteoporosis,but the specific targets and related mechanisms by which piRNAs exert their functions remain to be explored.OBJECTIVE:To investigate the effects and downstream mechanisms of piR-7472 on the differentiation of mouse osteoblasts(MC3T3-E1 cells).METHODS:(1)Twelve C57/BL6J mice were randomly divided into a sham-operated and an ovariectomized group,with six mice in each group.Changes in bone mass and the expression of piR-7472 were detected using Micro-CT and RT-qPCR,respectively,at 8 weeks after surgery.(2)MC3T3-E1 cells were divided into NC mimics group,piR-7472 mimics group,NC inhibitor group,and piR-7472 inhibitor group.The mRNA expression of piR-7472,osteopontin,type I collagen,Runt-related transcription factor 2,and potassium voltage-gated channel modifier subfamily F member 1 were detected by RT-qPCR after 7 days of osteogenic induction.The protein expression of osteopontin,Runt-related transcription factor 2,bone morphogenetic protein 2,and potassium voltage-gated channel modifier subfamily F member 1(KCNF1)was detected using western blot assay.The expression of alkaline phosphatase was detected by alkaline phosphatase staining after 14 days of osteogenic induction,and the number of mineralized nodules was detected by alizarin red staining after 21 days of induction.Whether piR-7472 could bind to KCNF1 was observed by the dual luciferase reporter gene assay.RESULTS AND CONCLUSION:(1)Bone mineral density,bone volume fraction,bone trabecular thickness,bone trabecular number were significantly decreased and bone trabecular separation was significantly increased in ovariectomized mice,and piR-7472 in bone tissue was significantly down-regulated in osteoporotic mice.(2)Compared with the NC group,the mRNA expression of osteopontin,type I collagen,and Runt-related transcription factor 2 were significantly increased,the protein expression of osteopontin,Runt-related transcription factor 2,and bone morphogenetic protein 2 were significantly elevated,and the levels of mineralized deposition and alkaline phosphatase were increased in the piR-7472 mimics group.Compared with the NC inhibitor group,the mRNA expression of osteopontin,type I collagen,and Runt-related transcription factor 2 was significantly downregulated,the protein expression of osteopontin,Runt-related transcription factor 2,and bone morphogenetic protein 2 were significantly decreased,and the levels of mineralized deposition and alkaline phosphatase were reduced in the piR-7472 inhibitor group.(3)piR-7472 was found to interact with the potassium voltage-gated channel modifier subfamily F member 1 as predicted by the miRanda database.The dual luciferase reporter gene assay revealed that piR-7472 mimics could bind to and promote the expression of KCNF1.To conclude,piR-7472 can promote osteogenic differentiation of osteogenic precursor cells MC3T3-E1,and its mechanism of action may be achieved by promoting the expression of KCNF1.
7.Efficacy and safety of flow diverter implantation versus stent-assisted coil embolization in unruptured saccular aneurysms located at distal segments of the Willis circle
Peifeng GUAN ; Lunzhe YANG ; Xiangbin WANG ; Yilin LIU ; Xingqiao YANG ; Runze GE ; Hui JIANG ; Chuanzhi DUAN ; Guangzhong CHEN
Chinese Journal of Neuromedicine 2025;24(11):1107-1114
Objective:To compare the efficacy and safety of flow diverter (FD) implantation versus stent-assisted coil embolization (SACE) in unruptured saccular aneurysms located at distal segments of the Willis circle.Methods:A retrospective study was performed; 119 patients with unruptured saccular aneurysms located at distal segments of the Willis circle who received FD implantation or SACE in Department of Neurosurgery, Guangdong Provincial People's Hospital, Southern Medical University and Department of Cerebrovascular Surgery, Neurosurgery Center, Southern Medical University from January 2018 to May 2025 were selected. According to different surgical methods, they were divided into a FD group ( n=60) and a SACE group ( n=59). These patients were subjected to propensity score matching (PSM) using 1:1 nearest neighbor matching method to eliminate confounding factors such as gender, age, aneurysm location, and aneurysm diameter (maximum diameter); and then, differences in neurological functional prognosis (good prognosis: modified Rankin scale scores of 0-2), complete aneurysm occlusion rate (O'Kelly-Marotta grade D or Raymond occlusion classification class I), and overall (perioperative and follow-up) complications were compared between the two groups. Results:After PSM, there were 43 patients in both FD group and SACE group. No significant difference was found in clinical and imaging follow-ups (12[6, 19] months vs. 10[6, 15] months, 10[5, 19] months vs. 9[2, 15] months) between the FD group and SACE group ( P>0.05). At the last imaging follow-up, the complete aneurysm occlusion rate in the FD group (65.1%[28/43]) was significantly lower than that in the SACE group (76.7%[33/43], P<0.05). At the last clinical follow-up, no significant difference was noted in good prognosis rate (95.3%[41/43] vs. 97.7%[42/43]) and overall complication rate (30.2%[13/43] vs. 18.6%[8/43]) between the FD group and SACE group ( P>0.05). Conclusion:Both FD implantation and SACE are safe and effective for unruptured saccular aneurysms located at distal segments of the Willis circle; the complete aneurysm occlusion rate within 1 year of FD implantation is relatively low.
8.Preliminary application of augmented reality(AR)system in cerebrovascular disease surgery
Xingqiao YANG ; Kun QIN ; Jianqing MO ; Hui JIANG ; Xiangbin WANG ; Yong YANG ; Chao PENG ; Lunzhe YANG ; Hongqin WANG ; Hanwu HE ; Guangzhong CHEN
Chinese Journal of Nervous and Mental Diseases 2025;51(8):482-486
Objective To assess the clinical feasibility of a self-developed augmented reality(AR)system in surgeries for cerebral arteriovenous malformation(AVM),dural arteriovenous fistula(DAVF),moyamoya,and internal carotid artery stenosis.This system integrates preoperative vascular imaging(CTA,MRA,DSA)with intraoperative real-time visualization through high-precision patient-image registration and virtual-real integration technology.Methods A retrospective analysis was conducted on 6 patients(1 cerebral AVM,1 DAVF,3 moyamoya and 1 internal carotid artery stenosis)collected between March 2023 and April 2024.AR with three-dimensional reconstruction was used for preoperative precise localization and intraoperative navigation guidance.Clinical feasibility was evaluated and analyzed using an intraoperative self-controlled method.Results All 6 patients with diverse etiologies successfully underwent preoperative precise localization and intraoperative navigation guidance under AR three-dimensional reconstruction modeling.This technology achieved visualization of intracranial arteriovenous structures and precise lesion locations,providing surgeons with a visual reference for accurate planning of the surgical approach and operative field.Conclusion The application of AR with three-dimensional reconstruction is safe and feasible in neurosurgical procedures for cerebrovascular diseases.It demonstrates satisfactory effectiveness in preoperative localization and intraoperative navigation guidance.
9.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
10.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.

Result Analysis
Print
Save
E-mail