1.Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report
Jianbin GAO ; Jian LI ; Yu YANG ; Mier MA ; Kairui YANG ; Wei LUO ; Ning WANG ; Da ZHU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):163-166
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
2.Experimental study on the ultrasound visibility of a novel interventional catheter and delivery system: In vitro and animal experiments
Ziping LI ; Wenbin OUYANG ; Zizheng LIU ; Ning ZHOU ; Jie DONG ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):784-790
Objective To assess the echogenicity of the ultrasound-guided catheter and its associated delivery system. Methods The study consisted of in vitro characterization experiments and animal studies. In the in vitro phase, the acoustic and mechanical properties of the ultrasound-guided catheter were compared with those of the traditional MPA2 catheter, including parameters such as echo intensity, recognizability, and angle dependence. In the animal experiments, a ventricular septal defect (VSD) model was established in miniature pigs to compare the procedural performance of the ultrasound-guided delivery system versus the conventional system. Evaluation indicators included the time required for the system to cross the VSD, the detection rate of the system within the right ventricle, and the occurrence of intraoperative complications. Results The ultrasound-guided catheter demonstrated a significantly higher mean echo intensity than the MPA2 catheter [(237.3±1.8) dB vs. (190.9±13.1) dB, P<0.001] and a markedly improved recognizability rate (82.3%±5.6% vs. 26.7%±3.2%, P<0.001), along with better angle independence and image quality. In animal experiments, the ultrasound-guided delivery system significantly reduced the time required to cross the VSD [(18.5±5.7) min vs. (30.3±4.5) min, P<0.001] and substantially increased the detection rate within the right ventricle (100.0% vs. 30.0%). No severe complications occurred in any experimental animal. Conclusion The ultrasound-guided catheter and its corresponding delivery system exhibite superior ultrasound visibility and operational performance in both in vitro and animal experiments, indicating strong potential for clinical application.
3.Shuhe Granules (舒和颗粒) in Treating Rheumatoid Arthritis Comorbid with Insomnia with Kidney-Heart Deficiency and Qi-Blood Disharmony Syndrome:An Exploratory Single-Arm Clinical Trial
Yonghao PAN ; Yuxi LI ; Yu GAO ; Xiangbin CHEN ; Kaixin GAO ; Runyue HUANG ; Fei TAN ; Jiamin YUAN ; Biyun XU ; Zhimin YANG
Journal of Traditional Chinese Medicine 2026;67(16):1743-1751
ObjectiveTo investigate the clinical effects and safety of Shuhe Granules (舒和颗粒) in patients with rheumatoid arthritis (RA) comorbid with insomnia. MethodsA single-arm prospective exploratory design was adopted. Thirty RA patients comorbid with insomnia and diagnosed with the traditional Chinese medicine (TCM) syndrome of kidney-heart deficiency and qi-blood disharmony were enrolled. On the basis of maintaining their original RA treatment regimens, all patients received oral Shuhe Granules, one dose per day, for 12 consecutive weeks. The outcomes were assessed before treatment and at weeks 4, 8, and 12 after treatment. Sleep and related psychosomatic function were evaluated using the insomnia severity index (ISI), Pittsburgh sleep quality index (PSQI), fatigue severity scale (FSS), patient health questionnaire-9 (PHQ-9), generalized anxiety disorder-7 (GAD-7), and Montreal cognitive assessment (MoCA) scores. RA-related assessments included the 28-joint disease activity score based on C-reactive protein (DAS28-CRP), pain visual analog scale (VAS), tender joint count (TJC28), swollen joint count (SJC28), morning stiffness duration, and health assessment questionnaire (HAQ) score. Laboratory parameters included erythrocyte sedimentation rate (ESR), serum C-reactive protein (CRP), anti-cyclic citrullinated peptide antibody (anti-CCP), and rheumatoid factor (RF) levels. A literature-based historical control group was established through literature retrieval and meta-analysis. The ISI, PSQI, DAS28-CRP, and pain VAS scores were compared between the treatment group in the present study and the historical control group. Safety assessments were also performed. ResultsCompared with baseline before treatment, ISI and PSQI scores decreased at weeks 4, 8, and 12, while MoCA scores increased at weeks 4, 8, and 12. FSS scores decreased at weeks 4 and 12. At weeks 8 and 12, GAD-7 scores, DAS28-CRP scores, duration of morning stiffness, TJC28, and SJC28 were reduced. At week 12, PHQ-9, pain VAS, and HAQ scores significantly decreased (P<0.05). FSS and DAS28-CRP scores at week 12 were lower than those at week 4, and CRP levels at week 8 were lower than those at week 4 (P<0.05). Compared with the historical control group, the treatment group showed superior improvement in ISI and PSQI scores (P<0.001); however, no statistically significant differences were observed between the two groups in DAS28-CRP or pain VAS scores (P>0.05). No serious adverse events occurred during the study, and the 4 reported mild adverse events were all considered unrelated to the study medication. ConclusionShuhe Granules significantly improve sleep quality, fatigue, emotional status, cognitive function, RA-related symptoms, and joint function in patients with RA comorbid insomnia, with good safety and tolerability.
4.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
5.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
6.Echocardiography-guided Transcatheter Aortic Valve Replacement After Aortic Bioprosthetic Failure:a Case Report
Guangzhi ZHAO ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):290-292
This article reports a case of transcatheter aortic valve replacement guided by echocardiography only for the treatment of aortic valve bioprosthesis failure.The patient developed bioprosthesis stenosis eight years after surgical bioprosthetic aortic valve replacement and underwent successful transcatheter aortic valve-in-valve replacement under echocardiography guidance.This offers a new treatment option for valve replacement after bioprosthetic valve failure under echocardiography guidance,and demonstrates the feasibility of echocardiography-guided interventional transcatheter valve-in-valve replacement.Also,this report discusses the technique details in valve positioning,reducing the risk of complications and improving prognosis.
7.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
8.Two Cases of Transcatheter Aortic Valve Replacement Guided by Echocardiography Alone for Severe Aortic Stenosis
Shouzheng WANG ; Guangzhi ZHAO ; Xiaopeng HU ; Hao SHI ; Bo PENG ; Xu WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):284-289
Transcatheter aortic valve replacement(TAVR)has become an important therapeutic approach for severe aortic stenosis.However,complications associated with TAVR cannot be overlooked,among which contrast agents induced acute kidney injury(AKI)is a common complication.To explore methods to reduce the occurrence of AKI,this article reports two cases of successful treatment of severe aortic stenosis by TAVR under pure echocardiographic guidance,both of whom were elderly women aged 75 and 69,respectively,and both were implanted with a Evolute Pro 26 mm valve.Postoperative echocardiography showed good valve positioning and function.
9.One-year outcomes of a novel domestic transcatheter aortic valve system in severe aortic stenosis: a multicenter cohort study
Yuehuan LI ; Jiawei ZHOU ; Lai WEI ; Yingqiang GUO ; Liang MA ; Huiming GUO ; Xiangbin PAN ; Dongjin WANG ; Fanyan LUO ; Jue WANG ; Minxin WEI ; Deguang FENG ; Yingbin XIAO ; Liming LIU ; Jian′an WANG ; Jiangang WANG ; Haibo ZHANG
Chinese Journal of Surgery 2025;63(11):1052-1058
Objective:To examine the safety and effectiveness of a novel domestic transcatheter aortic valve system in addressing severe aortic valve stenosis.Methods:This prospective, multicenter, single-arm target-value clinical trial enrolled patients with severe aortic stenosis meeting inclusion criteria from 13 Chinese centers between July 2021 and April 2022. The primary endpoint was all-cause mortality at 1-year post-procedure. Secondary endpoints included safety outcomes (30-day all-cause mortality, 1-year major adverse cardiovascular events, device success) and efficacy parameters (transvalvular pressure gradient, paravalvular leak severity, New York Heart Association(NYHA)class improvement, and quality of life). Survival analysis was performed using the Kaplan-Meier analysis.Results:The study included 134 patients, 85 males and 49 females, with an age of (73.6±5.6)years (range: 65.1 to 91.8 years). Bicuspid aortic valve morphology was present in 59.7% (80/134). Device success rate was 99.3%, with one case converted to open surgery due to coronary obstruction. All-cause mortality was 0.8% (95% CI: 0.1% to 5.3%) at both 30-day and 1-year follow-up, significantly lower than the 25% target value ( P<0.01). Permanent pacemaker implantation rates remained 2.2% (3/134) at both timepoints. Stroke incidence was 0.7% (1/134) at 30 days and 1.5% (2/134) at 1 year. Myocardial infarction rates were 0.7% (1/134) at both intervals. The postoperative transvalvular pressure gradient of the aortic valve was (6.6±3.1) mmHg(1 mmHg=0.133 kPa) (range: 4 to 8 mmHg). Among the patients, 32 cases (23.9%) had mild paravalvular leakage, 4 cases (3.0%) had moderate paravalvular leakage, and no severe paravalvular leakage was observed. NYHA class Ⅰ and Ⅱ patients increased from 18.7% preoperatively to 99.3% postoperatively. Conclusion:The novel domestic transcatheter aortic valve system demonstrates satisfactory 1-year safety and efficacy outcomes in treating severe aortic stenosis.
10.Animal study results of a novel designed transcatheter mitral valve replacement system
Da ZHU ; Shouzheng WANG ; Jianbin GAO ; Zhiling LUO ; Ke YANG ; Chunmei XIE ; Pengxu KONG ; Shuyi FENG ; Hong JIANG ; Xiangbin PAN
Chinese Journal of Cardiology 2025;53(3):287-292
Objective:To preliminarily assess the biocompatibility and durability of the TruDelta TM transcatheter mitral valve replacement (TMVR) system. Method:Six adult sheep were divided into 3 groups based on the duration of follow-up: 30 days ( n=1), 90 days ( n=3) and 180 days ( n=2). The TruDelta TM TMVR system was implanted through a transapical approach under transesophageal echocardiographic guidance. The operability of the TMVR system was evaluated using an instrument performance evaluation scale (consisting of 39 items), with scores ranging from 1 (worst) to 10 (best) assigned by the operator. Echocardiography was conducted preoperatively, immediately after surgery, and at 30, 90, and 180 days post-implantation. At the last follow-up time point, the intervention mitral valve membrane and major organs were dissected for observation. The artificial valves were taken for hematoxylin eosin (HE) staining and observed under a scanning electron microscope. Result:All six procedures were successfully completed using 29S size TruDelta TM TMVR device. At the final follow-up, echocardiogram demonstrated good valve function without obvious paravalvular leakage, with a transvalvular gradient of (7.8±3.2) mmHg (1 mmHg=0.133 kPa) and a mitral valve orifice area of (1.8±0.2) cm 2. Autopsy findings revealed no structural valve failure and almost complete endothelialization (>75%) with 90 to 180 days. Both HE staining and scanning electron microscopy confirmed optimal endothelialization of the valve stent. Conclusion:The preclinical animal study indicates that the TruDelta TM device exhibits favorable biocompatibility and durability.

Result Analysis
Print
Save
E-mail