1.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
2.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
3.Establishment and evaluation of a lipopolysaccharide-induced acute respiratory distress syndrome model in minipigs
Chuang-Ye WANG ; Ran WANG ; Jian ZHANG ; Ling-Xiao QIU ; Bin QING ; Heng YOU ; Jin-Cheng LIU ; Bin WANG ; Nan-Bo WANG ; Jia-Yu LI ; Xing LIU ; Shuang WANG ; Jin HU ; Jian WEN ; Quan LI ; Xiao-Ou HUANG ; Kun ZHAO ; Shuang-Lin LIU ; Gang LIU ; Mei-Ju WANG ; Qing XIANG ; Hong-Mei WU ; Xiao-Rong SUN ; Tao GU ; Dong ZHANG ; Qi LI ; Zhi XU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1154-1161
Objective To establish a stable,reliable,and clinically relevant porcine model of endotoxin-induced acute respiratory distress syndrome(ARDS).Methods Ten 8-month-old male Bama minipigs were deeply sedated,followed by invasive mechanical ventilation and electrocardiographic monitoring.Lipopolysaccharide(LPS)was intravenously pumped at 600 μg/(kg·h)for 3 hours,then maintained at 15 μg/(kg·h)thereafter.Dynamic monitoring was performed at five time points after LPS injection(LPS 0,1,3,5,and 8 h),including arterial blood gas analysis and chest computed tomography(CT)scans.Pathological examination of lung tissues obtained via bronchoscopic biopsy(HE staining and transmission electron microscopy)was conducted.These indicators were comprehensively used to evaluate the success of the animal model.Results At 5 hours after LPS administration,8 minipigs developed symptoms such as skin cyanosis,elevated body temperature,and respiratory distress.The oxygenation index decreased to<300 mmHg.Chest CT scans showed diffuse pulmonary infiltrates.Histopathology revealed alveolar edema and hyaline membrane formation.Transmission electron microscopy demonstrated disruption of pulmonary blood-air barrier,depletion of lamellar bodies in type Ⅱ pneumocytes,inflammatory cell infiltration,and exudation of plasma proteins and fibrin.Compared with LPS 0 h,at LPS 8 h,the oxygenation index and arterial blood pH were significantly decreased(P<0.001),while blood lactic acid and serum potassium were significantly increased(P<0.05);serum calcium and base excess were significantly decreased(P<0.05),and the lung injury score based on HE-stained lung sections was significantly increased(P<0.01).Conclusion The porcine ARDS model established by continuous LPS injection can dynamically simulate the pathophysiological characteristics and typical pathological manifestations of clinical septic ARDS,making it an effective tool to study the pathogenesis,prevention,and treatment strategies of septic ARDS.
4.Effect of acupuncture on postoperative delirium in diabetic patients undergoing surgery under general anesthesia
Jiaxi LIU ; Qi WANG ; Lingling DING ; Jiaqi NING ; Hai KE ; Zhuoya CHEN ; Bo YU ; Weiming SUN ; Peng CHEN ; Xiang LI ; Shishun KOU ; Reiling ZHOU ; Yudong ZHOU ; Yan GUO ; Mengjie CHEN ; Ruyu YAN ; Jiansheng LUO
Chinese Journal of Anesthesiology 2025;45(10):1313-1316
Objective:To evaluate the effect of acupuncture on postoperative delirium (POD) in diabetic patients undergoing surgery under general anesthesia.Methods:In this randomized controlled trial, 92 diabetic patients of either sex, aged 30-80 yr, with a body mass index of 18-28 kg/m 2, of American Society of Anesthesiologists Physical Status classification Ⅱ or Ⅲ, scheduled for elective surgery under general anesthesia, were divided into 2 groups ( n=46 each) using a table of random numbers: control group (group C) and acupuncture group (group A). Group A received acupuncture at the Baihui (GV20), Shenting (GV24) and Sishencong (EX-HN1) acupoints before anesthesia. The needles were retained for 30 min, with manual stimulation applied every 10 min for 10 s each time. After 4 stimulations, routine anesthesia was carried out. Group C received routine anesthesia only. Regional cerebral oxygen saturation was recorded on admission to the operating room (T 0), after anesthesia induction (T 1), at the start of surgery (T 2), at the end of surgery (T 3), and immediately after tracheal extubation (T 4). The POD developed within 3 days after surgery was assessed. The occurrence of needle-related adverse effects such as fainting, subcutaneous bleeding, and local paresthesia was recorded. Results:Compared with group C, the incidence of POD was significantly reduced, and the regional cerebral oxygen saturation was increased at T 1, 4 in group A ( P<0.05). Conclusions:Acupuncture can decrease the development of POD in diabetic patients undergoing surgery under general anesthesia, which is related to an increase in regional cerebral oxygen saturation.
5.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
6.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
7.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
8.Establishment of a clinical risk scoring model for patients undergoing curative resection of pulmonary metastases from colorectal cancer based on primary tumor lymph node indices
Renshen XIANG ; Qi ZHANG ; Shuaibing LU ; Wenjing YANG ; Deyang KONG ; Yu SUN ; Huiru ZHANG ; Jialiang FAN ; Lin FENG ; Haizeng ZHANG
Chinese Journal of Oncology 2025;47(10):1039-1049
Objective:To analyze the clinicopathological factors affecting the prognosis of patients after curative resection of lung metastases (LMs) from colorectal cancer (CRC) and to construct a clinical risk scoring (CRS) model.Methods:This study retrospectively collected clinicopathological data and follow-up information on 132 patients who underwent radical resection of LMs from CRC at the Cancer Hospital of the Chinese Academy of Medical Sciences between January 2010 and December 2020. We analyzed the clinicopathological factors influencing patient prognosis using univariate and multivariate Cox proportional hazards regression models, and we developed a risk stratification model for prognostic prediction.Results:The median follow-up duration for the cohort of 132 patients was 54.2 months. During this period, 61 patients (46.2%) experienced recurrence or distant metastasis, resulting in a 5-year DFS rate of 54.1%. Additionally, 33 patients (25.0%) died, corresponding to a 5-year overall survival (OS) rate of 76.7%. Univariate Cox proportional hazards regression model analysis indicated that ten clinicopathological factors were significantly associated with OS (all P<0.05). These factors include the total number of lymph nodes (LNs) dissected from the primary tumor (PT) <16, the number of negative LNs from the PT <13, pN(+) of the PT, logarithmic odds of positive lymph nodes (LODDS) of the PT ≥-1.1, lymph nodes ratio (LNR) of the PT ≥0.02, preoperative carcinoembryonic antigen (CEA) level before LMs resection ≥10 ng/ml, the presence of hilar/mediastinal LN metastasis, the number of LMs ≥2, the maximum diameter of LMs ≥2.5 cm, and the necessity for hilar/mediastinal lymphadenectomy. Multivariate Cox proportional hazards regression analysis identified the number of negative LNs <13 ( HR=3.01, 95% CI: 1.28-7.03, P=0.011), pN(+) of the PT ( HR=5.04, 95% CI: 1.51-16.84, P=0.009), preoperative CEA level before LMs resection ≥10 ng/ml ( HR=5.39, 95% CI: 1.80-16.19, P=0.003), the number of LMs ≥2 ( HR=2.47, 95% CI: 1.09-5.60, P=0.030), and the necessity for hilar/mediastinal lymphadenectomy ( HR=2.74, 95% CI: 1.15-6.52, P=0.023) as independent prognostic risk factors. Patients were categorized based on independent risk factors, revealing statistically significant differences in OS across the groups with CRS scores of ≤2, 3~4, and ≥5 ( P<0.001). Conclusions:Independent risk factors associated with LMs from CRC patients include the number of negative LNs <13, pN(+) of the PT, preoperative CEA level before LMs resection ≥10 ng/ml, the number of LMs ≥2, and the necessity for hilar/mediastinal lymphadenectomy. Patients scoring 3 or higher on the CRS model may warrant cautious assessment for the appropriateness of direct surgical treatment.
9.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
10.The application of surgical robots in head and neck tumors.
Xiaoming HUANG ; Qingqing HE ; Dan WANG ; Jiqi YAN ; Yu WANG ; Xuekui LIU ; Chuanming ZHENG ; Yan XU ; Yanxia BAI ; Chao LI ; Ronghao SUN ; Xudong WANG ; Mingliang XIANG ; Yan WANG ; Xiang LU ; Lei TAO ; Ming SONG ; Qinlong LIANG ; Xiaomeng ZHANG ; Yuan HU ; Renhui CHEN ; Zhaohui LIU ; Faya LIANG ; Ping HAN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1001-1008

Result Analysis
Print
Save