1.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
2.A new method for flow cytometry-based detection of ABO antigen expression levels
Yuyu ZHANG ; Xi LIU ; Junhua XIE ; Bin CAO ; Jiewei ZHENG ; Xinyi ZHU ; Zhongying WANG ; Dong XIANG
Chinese Journal of Blood Transfusion 2025;38(5):665-672
Objective: To design and establish a new method for flow cytometry-based detection of commonly observed highly expressed antigens on red blood cells, and to further evaluate the differences and distribution characteristics of antigen expression levels between ABO blood type homozygotes and heterozygotes in healthy individuals. Methods: Residual blood samples after donor blood type identification by Shanghai Blood Center in April 2024 were collected. Among them, samples of 19 homozygous and 19 heterozygous individuals of type A and type B were selected. Then the expression level of ABO antigen on red blood cells were detected using the new method established in this study and the traditional aldehyde fixed red blood cell method. Both methods were tested independently three times and the results were compared. Results: The mean values of the three detection results of the new method was (×10
/RBC): AA homozygous 3.3±0.5, AO heterozygous 2.8±0.3, BB homozygous 3.6±0.3, BO heterozygous 3.1±2.8. The mean values of the three detection results of the aldehyde fixation method were AA homozygous 5.9±0.9, AO heterozygous 5.0±1.4, BB homozygous 3.8±0.6, and BO heterozygous 3.3±0.4. The average antigen distribution of each genotype followed a normal distribution. Comparing the average antigen expression levels of homozygotes and heterozygotes, both methods showed that A/B homozygotes had higher antigen levels than heterozygotes, with AA being 1.17 to 1.18 times that of AO and BB being 1.15 to 1.16 times that of BO. Comparing the inter batch differences in the three test results of two methods, the new method showed no significant difference in the three test results for four genotypes (P>0.05). The aldehyde fixation method showed significant differences in the test results for all three genotypes (P<0.01) except for BB homozygotes (P>0.05). The reliability and reproducibility of the new method were better than those of the traditional aldehyde fixation method. Conclusion: The antigen expression level of ABO homozygotes is higher than that of heterozygotes, and the difference in antigen level between type A homozygotes and heterozygotes is slightly higher than that of type B. The new method is superior to traditional aldolization fixation methods.
3.Association between Fish Consumption and Stroke Incidence Across Different Predicted Risk Populations: A Prospective Cohort Study from China.
Hong Yue HU ; Fang Chao LIU ; Ke Yong HUANG ; Chong SHEN ; Jian LIAO ; Jian Xin LI ; Chen Xi YUAN ; Ying LI ; Xue Li YANG ; Ji Chun CHEN ; Jie CAO ; Shu Feng CHEN ; Dong Sheng HU ; Jian Feng HUANG ; Xiang Feng LU ; Dong Feng GU
Biomedical and Environmental Sciences 2025;38(1):15-26
OBJECTIVE:
The relationship between fish consumption and stroke is inconsistent, and it is uncertain whether this association varies across predicted stroke risks.
METHODS:
A cohort study comprising 95,800 participants from the Prediction for Atherosclerotic Cardiovascular Disease Risk in China project was conducted. A standardized questionnaire was used to collect data on fish consumption. Participants were stratified into low- and moderate-to-high-risk categories based on their 10-year stroke risk prediction scores. Hazard ratios ( HRs) and 95% confidence intervals ( CIs) were estimated using Cox proportional hazard models and additive interaction by relative excess risk due to interaction (RERI), attributable proportion (AP), and synergy index (SI).
RESULTS:
During 703,869 person-years of follow-up, 2,773 incident stroke events were identified. Higher fish consumption was associated with a lower risk of stroke, particularly among moderate-to-high-risk individuals ( HR = 0.53, 95% CI: 0.47-0.60) than among low-risk individuals ( HR = 0.64, 95% CI: 0.49-0.85). A significant additive interaction between fish consumption and predicted stroke risk was observed (RERI = 4.08, 95% CI: 2.80-5.36; SI = 1.64, 95% CI: 1.42-1.89; AP = 0.36, 95% CI: 0.28-0.43).
CONCLUSION
Higher fish consumption was associated with a lower risk of stroke, and this beneficial association was more pronounced in individuals with moderate-to-high stroke risk.
Humans
;
China/epidemiology*
;
Male
;
Female
;
Stroke/etiology*
;
Middle Aged
;
Prospective Studies
;
Incidence
;
Aged
;
Animals
;
Fishes
;
Risk Factors
;
Diet
;
Seafood
;
Adult
;
Cohort Studies
4.Waist Circumference Status and Distribution in Chinese Adults: China Nutrition and Health Surveillance (2015-2017).
Jing NAN ; Mu Lei CHEN ; Hong Tao YUAN ; Qiu Ye CAO ; Dong Mei YU ; Wei PIAO ; Fu Sheng LI ; Yu Xiang YANG ; Li Yun ZHAO ; Shu Ya CAI
Biomedical and Environmental Sciences 2025;38(6):757-762
5.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
6.Study on lightweight plasma recognition algorithm based on depth image perception.
Hanwen ZHANG ; Yu SUN ; Hao JIANG ; Jintian HU ; Gangyin LUO ; Dong LI ; Weijuan CAO ; Xiang QIU
Journal of Biomedical Engineering 2025;42(1):123-131
In the clinical stage, suspected hemolytic plasma may cause hemolysis illness, manifesting as symptoms such as heart failure, severe anemia, etc. Applying a deep learning method to plasma images significantly improves recognition accuracy, so that this paper proposes a plasma quality detection model based on improved "You Only Look Once" 5th version (YOLOv5). Then the model presented in this paper and the evaluation system were introduced into the plasma datasets, and the average accuracy of the final classification reached 98.7%. The results of this paper's experiment were obtained through the combination of several key algorithm modules including omni-dimensional dynamic convolution, pooling with separable kernel attention, residual bi-fusion feature pyramid network, and re-parameterization convolution. The method of this paper obtains the feature information of spatial mapping efficiently, and enhances the average recognition accuracy of plasma quality detection. This paper presents a high-efficiency detection method for plasma images, aiming to provide a practical approach to prevent hemolysis illnesses caused by external factors.
Algorithms
;
Humans
;
Hemolysis
;
Plasma
;
Deep Learning
;
Image Processing, Computer-Assisted/methods*
7.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
8.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
9.Effect of printing orientation on physical and mechanical properties of 3D printing prosthodontic base resin materials
Xinxin ZHAN ; Lulu CAO ; Dong XIANG ; Hao TANG ; Dandan XIA ; Hong LIN
Journal of Peking University(Health Sciences) 2024;56(2):345-351
Objective:To analyze the influence of forming direction on the surface characteristics,elastic modulus,bending strength and fracture toughness of printed parts and the relationship between forming direction and force direction,and to provide scientific basis and guidance for the clinical applica-tion of oral denture base resin materials.Methods:The 3D printing technology was used to print denture base resin samples.The shape and size of the samples referred to the current standard for testing conven-tional denture base materials.The samples used for physical performance testing were cylindrical(with a diameter of 15 mm and a thickness of 1 mm)and printed at different angles along the Z axis(0°,45°,90°).Scanning electron microscope was used to observe the microscopic topography of the different sam-ples.The color stability of different samples was observed by color stabilizer.The surface roughness of the samples was analyzed by using surface roughness tester.The Vickers hardness was measured to ana-lyze the hardness of the samples.The samples used for mechanical performance testing were rectangular(elastic modulus and bending strength:A length of 64 mm,a width of 10 mm,and a height of 3.3 mm;fracture toughness:A length of 39 mm,a width of 8 mm,and a height of 4 mm),divided into two groups:W group and H group.The W group was printed from the bottom up along the Z axis with the length × width as the bottom surface parallel to the X,Y axis plane,while the H group printed from the bottom up along the Z axis with the length × height as the bottom surface parallel to the X,Y axis plane.The forming angles of both groups were equally divided into 0°,45°,and 90°.The elastic modulus,bending strength and fracture toughness of different samples were studied through universal mechanical testing machine.SPSS 22.0 software was used for statistical analysis.Results:The microscopic topogra-phy and roughness of different samples were closely related to the printing direction,with significant differences between the 0°,45°,and 90° specimens.The 0° specimens had the smoothest surface(roughness<1 μm).The surface of the 45 ° specimen was the roughest(roughness>3 μm).The microhardness of the 0° sample was the best[(196.13±0.20)MPa],with a significant difference com-pared with the 90° sample[(186.62±4.81)MPa,P<0.05].The mechanical properties of different samples were also closely related to the printing direction.The elastic modulus,bending strength,and fracture toughness of the 45° samples in the W group were the highest compared with the other groups.The results of elastic modulus showed that in the H group,the 45° specimens had the highest elastic mo-dulus,which was significantly different from the 0° and 90° specimens(P<0.05).The elastic modulus of 0° and 45° specimens in the W group were higher than those in 90° specimens(P<0.05).The bending strength results showed that there was no significant difference between the specimens from dif-ferent angles in the H group.The bending strength of the 90° specimens in the W group was the smallest,and there was a significant difference between 90° and the 0° and 45° specimens(P<0.05);And the bendind strength of the 0° and 45° specimens in the W group was significantly higher than that of the 0° and 45° specimens in the H group(P<0.05).The fracture toughness results showed that the fracture toughness of the H group specimens was lower than 1.9 MPa m1/2,which was specified in the denture base standard.The 45° samples in the W group were the highest,with significant differences compared with the 0° and 90° samples(P<0.05).And the 90° samples of the W group specimens were lower than 1.9 MPa m1/2.And the fracture toughness of the 45° specimen in the W group was significantly higher than that of all the specimens in the H group(P<0.05).Conclusion:The 0° samples had rela-tively better physical properties.The 45° samples had the best mechanical properties.But the fracture toughness of specimens(H group and 90° samples of W group)did not yet meet clinical requirements.That indicated that the characteristics of the 3D printing denture base resin were affected by the printing direction.Only when the performance of the printed samples in all directions met the minimum require-ments of the standard,they could be used in clinical practice.
10.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]

Result Analysis
Print
Save
E-mail