1.Curcumol Mediates the Programmed Cell Death in Acute Myeloid Leukemia through PI3K/AKT Signaling Pathway
Zuo-Tao LI ; Xiao-Yun CHEN ; Hai-Liang LI ; Gui-Xiang LENG ; Yan-Quan LIU ; Ling GUO ; Yi-Li WANG
Journal of Experimental Hematology 2024;32(6):1682-1688
Objective:To investigate the effects of Curcumol on the malignant biological characteristics of acute myeloid leukemia (AML)cells and its molecular mechanism,and to provide theoretical and experimental evidence for the anti-leukemia treatment of traditional Chinese medicine.Methods:After the AML cell lines HL-60 and KG-1 cells were treated different concentrations of with Curcumol.The proliferation activity of cells was detected by CCK-8 method,and the expression changes of apoptotic proteins and PI3 K/AKT signaling pathway proteins were detected by Western blot. Real-time quantitative fluorescence polymerase chain reaction (RT-qPCR ) was used to detect the expression of Caspase family mRNA.Results:Curcumol could inhibit the proliferation and induce apoptosis of HL-60 and KG-1 cells,promote apoptosis by up-regulating the expression of Bax and down-regulating the expression of Bcl-2 protein (P<0.05).When Curcumol interferes with HL-60 and KG-1 cells,it can also induce programmed cell death of AML by inhibiting PI3 K/AKT signaling pathway.In addition,after the intervention of Curcumol,the expression of Caspase 3,Caspase 6,Caspase 8 and Caspase 9 were up-regulated in HL-60 cells (P<0.05 ),the expression of Caspase 3,Caspase 8 and Caspase 9 were significantly up-regulated in KG-1 cells (P<0.01),while the expression of Caspase 6 was weakly affected (P<0.05 ),but low concentration of Curcumol (<60 μg/ml)had no effect on the expression of Caspase 6 in KG-1 cells (P>0.05).Conclusion:Curcumol may mediate the programmed death of AML cells by inhibiting the PI3K/AKT signaling pathway,affecting the expression of Bcl-2 family proteins,and promoting the activation of core members of Caspase family,so as to play an anti-leukemia role.
2.Characteristics of abnormal coronary aorta origin in adults and cause analysis of missed diagnosis by transthoracic echocardiography
Si-Yang ZUO ; Sen LI ; You-Xiang KANG ; Xiao-Ling ZHAO ; Li-Xing WANG ; Rui CHEN ; Zhi-Yu FENG
Chinese Medical Equipment Journal 2024;45(1):71-75
Objective To analyze the characteristics of adult anomalous aortic origin of coronary artery(AAOCA)and the causes of missed diagnosis by transthoracic echocardiography(TTE)so as to facilitate TTE in diagnosing adult AAOCA.Methods A total of 37 adult patients with AAOCA diagnosed by non-invasive coronary CT angiography(CCTA)and/or invasive coronary angiography(ICA)were selected as research samples at some hospital from January 2019 to December 2022,and their clinical symptoms and the findings of 12-lead electrocardiogram,cardiac enzymes and TTE were summarized;the patients were typed according to the site of origin of coronary artery anomalies,and the causes for the missed diagnosis of TTE were eplored.Chi-square test was used to compare the differences in TTE missed diagnoses.Results Of the 37 patients,31 ones had no or only mild symptoms;most ones had negative results in terms of 12-lead electrocardiography,cardiac enzymes,changes in the size of the cardiac chambers,segmental ventricular wall motion abnormalities and left ventricular systolic function.The patients with anomalous origin of the right coronary artery from left sinus(ARCA-L)gained the largest proportion of 59.45%(22/37);21 patients were diagnosed with anomalous origin of coronary artery arising from the opposite sinus(ACAOS)in the two examinations of TTE,of whom there were 19 cases of ARCA-L,and the detection rate of ACAOS by TTE was 87.5%;all the 13 patients origins in branches and high-grade openings were missed by TTE.The detection rate of ACAOS by TTE was significantly higher than that of coronary artery anomalies originating in branches and in high openings,and the difference was statistically significant(21/24 vs 0/13,P<0.001).Conclusion Most adult AAOCA patients lack specificity in symptoms and related examination results.TTE has a high detection rate of ACAOS,while it is easy to miss the diagnosis of coronary artery anomalies originating from branches and high openings.Ultrasonographers have to identify false negative AAOCA by multi-section and multi-angle scanning and color Doppler flow imaging in order to reduce the rate of missed diagnosis.[Chinese Medical Equipment Journal,2024,45(1):71-75]
3.Environmental contamination related to the first patient with carbapenem-resistant Acinetobacter baumannii infection and the infection status of pa-tients in the intensive care unit in Tibetan areas
Cuo-Ta QIE ; Ding-Ying HE ; Fu-Yan LONG ; Xiao-Hua ZHANG ; Chun-Hua PENG ; Xiang-Xiang JIANG ; Ming-Lei DENG ; Cong FU ; Guo-Ping ZUO
Chinese Journal of Infection Control 2024;23(2):220-224
Objective To investigate the environmental contamination related to first patient with carbapenem-re-sistant Acinetobacter baumannii(CRAB)infection and the infection status of relevant patients in a newly established intensive care unit(ICU)of a hospital in Tibetan area,and analyze the transmission risk.Methods From the ad-mission in ICU of a patients who was first detected CRAB on November 15,2021 to the 60th day of hospitalization,all patients who stayed in ICU for>48 hours were performed active screening on CRAB.On the 30th day and 60th day of the admission to the ICU of the first CRAB-infected patient,environment specimens were taken respectively 2 hours after high-frequency diagnostic and therapeutic activities but before disinfection,and after disinfection but before medical activities.CRAB was cultured with chromogenic culture medium.Results Among the 13 patients who were actively screened,1 case was CRAB positive,he was transferred from the ICU of a tertiary hospital to the ICU of this hospital on November 19th.On the 40th day of admission to the ICU,he had fever,increased frequency for sputum suction,and CRAB was detected.The drug sensitivity spectrum was similar to that of the first case,and he also stayed in the adjacent bed of the first case.64 environmental specimens were taken,and 9 were positive for CRAB,with a positive rate of 14.06%,8 sampling points such as the washbasin,door handle and bed rail were positive for CRAB after high-frequency diagnostic and therapeutic activities.After routine disinfection,CRAB was detected from the sink of the washbasin.Conclusion For the prevention and control of CRAB in the basic-level ICU in ethnic areas,it is feasible to conduct risk assessment on admitted patients and adopt bundled prevention and con-trol measures for high-risk patients upon admission.Attention should be paid to the contaminated areas(such as washbasin,door handle,and bed rail)as well as the effectiveness of disinfection of sink of washbasin.
4.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
5.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
6.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
7.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
8.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
9.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
10.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.

Result Analysis
Print
Save
E-mail