1.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
2.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
3.Clinicopathologic characteristics of patients with ovarian metastases from colorectal cancer and construction of postoperative prognostic models
Qi ZHANG ; Renshen XIANG ; Shuaibing LU ; Wenjing YANG ; Deyang KONG ; Yu SUN ; Huiru ZHANG ; Xuesi DONG ; Jialiang FAN ; Lin FENG ; Haizeng ZHANG
Chinese Journal of Surgery 2025;63(12):1137-1145
Objective:To construct and validate a prognostic prediction model for patients with ovarian metastases from colorectal cancer after radical resection.Methods:A retrospective case series analysis was conducted on the clinical and pathological data of 81 patients with colorectal cancer and ovarian metastases who underwent radical resection for ovarian metastases at the Department of Colorectal Surgery, Cancer Hospital, Chinese Academy of Medical Sciences, between January 2014 and December 2023. The patients were all female, with an age ( M(IQR)) of 49(13) years (range: 22 to 79 years). The primary tumor was located in the colon in 60 cases (74.1%) and in the rectum in 21 cases (25.9%). Univariate and multivariate Cox regression analyses were used to identify independent risk factors affecting prognosis. A risk scoring system was constructed, and patients were assigned to high-risk and low-risk groups based on their risk scores. The predictive performance of the scoring system was assessed, and 5-fold cross-validation was performed to evaluate the model′s stability on the internal dataset. Results:Among the 81 patients with ovarian metastases, a high proportion had T4 stage (58 cases, 71.6%), lymph node positivity (68 cases, 84.0%), and colon cancer (60 cases, 74.1%). Preoperative imaging suggested unilateral ovarian metastasis in 15 patients (23.4%), but pathological examination after bilateral oophorectomy confirmed bilateral ovarian metastases. Among the 17 patients who initially underwent unilateral oophorectomy, 11 developed contralateral ovarian metastases at varying times postoperatively. Univariate Cox proportional hazards regression analysis revealed that positive lymph node ratio ( HR=2.68,95% CI:1.41 to 5.09, P=0.003), N stage ( HR=2.07,95% CI:1.08 to 3.95, P=0.028),maximum diameter of metastatic tumors ( HR=2.27,95% CI:1.04 to 4.96, P=0.040),and peritoneal metastasis or ascites at the time of ovarian metastasis ( HR=2.04,95% CI:1.02 to 4.08, P=0.043) were significantly associated with overall survival in patients with ovarian metastasis from colorectal cancer. Multivariate regression analysis identified that positive lymph node ratio ( HR=3.34,95% CI:1.08 to 10.34, P=0.037) and maximum diameter of metastatic tumors ( HR=2.65,95% CI:1.19 to 5.88, P=0.017) were independent prognostic factors for overall survival following radical oophorectomy in patients with ovarian metastasis from colorectal cancer. Based on the regression coefficients from the multivariate analysis for variables (ovarian metastatic tumor diameter ≥6 cm, positive lymph node ratio ≥0.3,and presence of peritoneal metastasis or ascites), a risk scoring system was developed. Using the optimal cutoff value (154 points) for the risk score,patients were divided into high-risk (19 cases) and low-risk (62 cases) groups. Kaplan-Meier survival curves demonstrated that the high-risk group had significantly lower median overall survival (27 months) and median disease-free survival (22 months) compared to the low-risk group (median overall survival 90 months,median disease-free survival not reached; both P<0.01). Receiver operating characteristic curve analysis showed that the area under the curve(AUC) for predicting 1-,3-,and 5-year overall survival was 0.731(95% CI:0.563 to 0.899), 0.703(95% CI:0.573 to 0.833), and 0.776(95% CI: 0.657 to 0.894), respectively. The AUC for predicting 1-,3-, and 5-year disease-free survival was 0.724(95% CI:0.397 to 0.993),0.710(95% CI:0.514 to 0.906),and 0.688(95% CI:0.478 to 0.898),respectively,indicating good performance of the model.The decision curve analysis showed that the model has good clinical net benefit and the results of the 5-fold cross-validation showed that the model demonstrated stability in the internal dataset. Conclusions:When performing radical resection for ovarian metastasis from colorectal cancer,bilateral oophorectomy should be considered to minimize the risk of postoperative recurrence. Patients with ovarian metastasis from colorectal cancer,characterized by a metastatic tumor diameter ≥6 cm,a positive lymph node ratio ≥0.3,and the presence of peritoneal metastasis or ascites, tend to have a poorer prognosis. Based on these findings,a clinical prognostic scoring system for radical resection of ovarian metastasis from colorectal cancer has been developed to stratify patients into different risk groups and may assist in postoperative risk assessment and management.
4.Symptoms and quality of life benefits of successful percutaneous coronary intervention in left main disease and/or 3-vessel disease patients with diabetes
Bo-da ZHU ; Tian-tong YU ; Peng HAN ; Bo-hui ZHANG ; Xi ZHANG ; Ping YUAN ; Gang WANG ; Yi YANG ; Hui-li ZHU ; Pan-pan SUN ; Tong-tong LI ; Shuai ZHAO ; Cheng-xiang LI ; Kun LIAN
Chinese Journal of Interventional Cardiology 2025;33(2):93-100
Objective To investigate whether successful percutaneous coronary intervention(PCI)could improve symptoms and quality of life(QOL)in left main disease and/or 3-vessel disease patients with diabetes.Methods Patients with left main disease and/or 3-vessel disease who underwent PCI in the First Affiliated Hospital of Air Force Medical University from April 2018 to May 2021 were consecutively enrolled and subdivided into 2 groups:diabetes and no diabetes.Detailed baseline characteristics,symptoms,including dyspnea and angina,assessed with the Rose dyspnea scale(RDS),Seattle angina questionnaire(SAQ),the European quality of life-5 dimensions(EQ-5D)and 12-item short-form health survey(SF-12)questionnaire respectively,procedural details,and 1 month and 1 year follow-up data were collected.Results Among 440 left main disease and/or 3-vessel disease patients,disease was present in 176(40.00%),who had more hypertension,peripheral artery disease,and LCX lesion(all P<0.05).The incidence of major adverse cardiovascular events(MACE)and all-cause mortality were similar between the two groups(both P>0.05)at 1 month follow-up,while all-cause mortality in diabetes patients was significantly higher than those without diabetes at 1 year follow-up(P=0.013).Low left ventricular ejection fraction was an independent risk factor for MACE and all-cause mortality at 1 month and 1 year follow-up after successful revascularization(all P<0.05).Most importantly,symptoms,including dyspnea and angina,and QOL were markedly improved regardless of diabetes both at 1 month and 1 year follow-up(all P<0.05).Diabetes patients showed improved dyspnea and QOL at similar degree to the non-diabetes patients(all P>0.05)and a more significantly relieved angina(P=0.013).Additionally,the number of chronic total occlusion(CTO)per patient was identified as an independent risk factor of dyspnea(OR 0.723,95%CI 0.525~0.997,P=0.048)and angina relief(OR 0.686,95%CI 0.473~0.995,P=0.047),and the contrast volume(OR 0.995,95%CI 0.992~0.999,P=0.008)as an independent risk factor of QOL improvement in diabetic patients.Conclusions Successful PCI is beneficial for relieving symptoms and improving quality of life in patients with diabetes who have left main disease and/or 3-vessel disease.
5.Clinicopathological features and prognosis of rectal neuroendocrine tumor with grade 2
Zhenkai LUO ; Qi ZHANG ; Xiaoting MA ; Renshen XIANG ; Shuaibing LU ; Deyang KONG ; Yu SUN ; Yingying FENG ; Wei PEI ; Lin FENG ; Yuelu ZHU ; Lin YANG ; Haizeng ZHANG
Chinese Journal of Oncology 2025;47(1):108-117
Objective:To explore the clinicopathological features of rectal neuroendocrine tumor (R-NET) G2, identify prognostic factors, and summarize treatment experience.Methods:The clinical data of patients diagnosed with R-NET G2 by pathological diagnosis admitted to Cancer Hospital of the Chinese Academy of Medical Sciences from January 2003 to September 2023 were retrospectively analyzed. The Fisher's exact test and Kaplan-Meier curves were performed to analyze the association between pathological features and prognosis.Results:A total of 22 patients were enrolled in this study and 21 patients were followed up for a period of 6-98 months with a median follow-up time of 42 months. 5 patients died due to tumor progression during the follow-up period. The 1-, 3-, and 5-year cancer-specific survival (CSS) of the whole group were 100.0%, 92.9%, and 69.6%, respectively. Of the 22 patients, 20 underwent surgical treatment, of which 15 underwent postoperative adjuvant therapy; 2 underwent medical treatment for liver and bone multiple metastases. The 5-year survival rates of patients with tumours ≥2 cm in length, T2-3 stage, lymph node metastasis, and distant metastasis (57.1%, 68.8%, 66.7%, and 63.6%, respectively) were shorter than those of patients with tumours <2 cm in length, T1 stage, no lymph node metastasis, and no distant metastasis (all 100.0%, P<0.001). In addition, patients with liver metastases had larger primary tumor diameters and higher T-stages compared with those without distant metastasis ( P<0.05). Conclusions:R-NET G2 has a high degree of malignancy compared with G1 and a high propensity for metastasis. Clinicians should formulate appropriate diagnostic and treatment strategies based on factors such as tumor size, depth of invasion, lymph node status, presence of distant metastasis, and the location and extent of distant metastasis.
6.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
7.Analysis of reoperation causes in unilateral biportal endoscopy for treating lumbar degenerative diseases
Yuquan LIU ; Guangpeng LI ; Xiang LI ; Bin ZHU ; Weiyang ZUO ; Haining TAN ; Ning LIU ; Qi FEI ; Haibo SUN ; Tianqi FAN ; Yong YANG ; Lingjia YU
International Journal of Surgery 2025;52(2):108-113
Objective:To analyze the reoperation rate and causes during the early adoption phase of unilateral biportal endoscopy (UBE).Methods:The clinical data of 180 patients who underwent UBE performed by a single surgeon at Beijing Friendship Hospital, Capital Medical University from October 2021 to June 2023 were retrospectively analyzed. Clinical and imaging data of patients who underwent reoperation were collected to analyze the causes of reoperation, and the clinical efficacy of the reoperations was also followed up. Measurement data were expressed as mean ± standard deviation ( ± s), and t-test was used before and after treatment. Results:A total of 180 patients who underwent UBE were included in this study, of which 6 patients underwent reoperation, and the reoperation rate was 3.33%. Among them, 3 cases occurred in the first 90 surgeries and the other 3 occurred in the subsequent 90 surgeries. The causes of reoperation were as follows: recurrent lumbar disc herniation at the same segment postoperatively in 2 cases, insufficient decompression in 2 cases, disc herniation following isolated decompression in 1 case, and immediate postoperative perianal numbness in 1 case. The time between the initial surgery and reoperation ranged from 0 to 187 days, with an average of 63.3 days. The average follow-up time after reoperation was 18.3 months. The visual analogue scale (VAS) and Oswestry disability index (ODI) scores of the patients at the last follow-up were significantly improved compared with those before operation (VAS score of low back pain: 5.2 ± 1.7 before operation, 1.2 ± 0.8 at the last follow-up, P<0.001; VAS score of leg pain: 7.2 ± 1.5 before operation, 1.2 ± 1.2 at the last follow-up, P<0.001; ODI score: 67.3 ± 5.7 before operation, 20.2 ± 8.2 at the last follow-up, P<0.001). The postoperative modified MacNab scores were generally satisfactory (4 cases were rated as excellent, accounting for 66.7%; 2 cases were rated as good, accounting for 33.3%). Except for one patient who experienced dural injury during open revision surgery, there were no serious complications such as nerve damage. Conclusions:In the early stages of UBE surgery, recurrent lumbar disc herniation and inadequate decompression are the primary reasons for reoperation, typically occurring within the first three months postoperatively. Reoperation does not significantly increase the risk of nerve injury. Enhanced early postoperative follow-up is recommended. For symptomatic patients, a second surgery with thorough decompression can yield satisfactory treatment outcomes.
8.Effect of acupuncture on postoperative delirium in diabetic patients undergoing surgery under general anesthesia
Jiaxi LIU ; Qi WANG ; Lingling DING ; Jiaqi NING ; Hai KE ; Zhuoya CHEN ; Bo YU ; Weiming SUN ; Peng CHEN ; Xiang LI ; Shishun KOU ; Reiling ZHOU ; Yudong ZHOU ; Yan GUO ; Mengjie CHEN ; Ruyu YAN ; Jiansheng LUO
Chinese Journal of Anesthesiology 2025;45(10):1313-1316
Objective:To evaluate the effect of acupuncture on postoperative delirium (POD) in diabetic patients undergoing surgery under general anesthesia.Methods:In this randomized controlled trial, 92 diabetic patients of either sex, aged 30-80 yr, with a body mass index of 18-28 kg/m 2, of American Society of Anesthesiologists Physical Status classification Ⅱ or Ⅲ, scheduled for elective surgery under general anesthesia, were divided into 2 groups ( n=46 each) using a table of random numbers: control group (group C) and acupuncture group (group A). Group A received acupuncture at the Baihui (GV20), Shenting (GV24) and Sishencong (EX-HN1) acupoints before anesthesia. The needles were retained for 30 min, with manual stimulation applied every 10 min for 10 s each time. After 4 stimulations, routine anesthesia was carried out. Group C received routine anesthesia only. Regional cerebral oxygen saturation was recorded on admission to the operating room (T 0), after anesthesia induction (T 1), at the start of surgery (T 2), at the end of surgery (T 3), and immediately after tracheal extubation (T 4). The POD developed within 3 days after surgery was assessed. The occurrence of needle-related adverse effects such as fainting, subcutaneous bleeding, and local paresthesia was recorded. Results:Compared with group C, the incidence of POD was significantly reduced, and the regional cerebral oxygen saturation was increased at T 1, 4 in group A ( P<0.05). Conclusions:Acupuncture can decrease the development of POD in diabetic patients undergoing surgery under general anesthesia, which is related to an increase in regional cerebral oxygen saturation.
9.Construction of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) based on the Delphi method
Shixiang GAO ; Zhijian SUN ; Changrun LI ; Dongchen YAO ; Han FEI ; Zhelun TAN ; Xiang YU ; Yinghong MA ; Shiyu ZHU ; Ting LI
Chinese Journal of Orthopaedic Trauma 2025;27(8):709-714
Objective:To report construction of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) using the Delphi method.Methods:Literature related to the study of adult distal radius fractures was fully searched for and evaluated. An expert group was established from representative experts from all over the nation. The related clinical issues were established by consulting the experts in the form of electronic questionnaires, strictly following the Delphi research method. After the first draft of Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) was written, an expert consultation questionnaire was designed for the recommendation opinions to determine the recommendation strength.Results:The clinical issues were determined by 2 rounds of correspondence based on the Delphi method. For the both rounds of correspondence, the questionnaire recovery rates were respectively 88.68% (47/53) and 98.11% (52/53), and the expert authority coefficients >0.7. According to the screening criteria based on the importance of clinical issues (mean importance score <3.5 points or a coefficient of variation ≥0.25 points and a full score ratio <30%) and expert opinions, a total of 40 clinical issues were deleted in the first round of determination of clinical issues, and a total of 5 clinical issues deleted in the second round of determination of clinical issues. The reliability analysis of the results of the 2 rounds of questionnaires showed that the Cronbach α coefficient was >0.9. In the questionnaire to determine the recommendation strength, according to the screening criteria for the consistency of recommendation strength (consistency ≥ 70%) and expert opinions, a total of 26 recommendations were screened in the first round. In the second round when the remaining 4 recommendations were investigated, one recommendation reached the consistency of recommendation strength ≥ 70%. Eventually, 27 recommendations were formed.Conclusion:The Evidence-Based Guidelines for the Diagnosis and Treatment of Distal Radius Fractures in Adults (2024) constructed using the Delphi method shows good scientific validity, authority, and reliability, providing methodological references for guideline development and research.
10.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.

Result Analysis
Print
Save