1.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
2.Evaluation of Hemolytic Performance of Cellulose Hemostatic Products
Qing-qing HOU ; Qin-lian JIAO ; Chun-xia QIAO ; Zi-ye WANG ; Xiao-yan WANG ; Wen-qian MA ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(9):1488-1495
Objective:To compare the differences in the evaluation of hemolysis performance of cellulose hemostatic materials using different detection methods and test media,and to explore a m ore reasonable testing plan for such products.Methods:Hemolysis tests were conducted on cellulose hemostatic materials using the absorbance measurement hemolysis method and hemoglobin concentration measurement hemolysis method in accordance with YY/T 1651.1-2019 standard.We compared the changes in hemolysis rate,pH value,and osmotic pressure under different experimental media.Results:Under the same experimental method,compared to SC,the hemolysis results using PBS as the extraction medium are smaller,and the changes in pH and osmotic pressure are closer to the normal range of human body changes.Conclusions:The changes in pH and osmotic pressure may be one of the reasons for the high hemolysis rate of cellulose hemostatic materials.Choosing PBS with buffering effect as the leaching medium may be more suitable for evaluating the hemolysis performance of cellulose hemostatic materials.
3.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
4.Clinical efficacy and safety of a domestic calcipotriol/betamethasone dipropionate ointment in the treatment of stable plaque psoriasis: a multicenter, randomized, double-blind, controlled study
Lixin XIA ; Guang XIANG ; Qingchun DIAO ; Kun HUANG ; Shoumin ZHANG ; Shanshan LI ; Yumei LI ; Zhiqiang SONG ; Qing SUN ; Xiumin YANG ; Meng PAN ; Yuling SHI ; Shuping GUO ; Huiping WANG ; Tiechi LEI ; Xiaoyong ZHOU ; Songmei GENG ; Suchun HOU ; Juan SU ; Yong CUI ; Rixin CHEN ; Yanyan FENG ; Hongxia FENG ; Rushan XIA ; Zudong MENG ; Fang YIN ; Jingjing WANG ; Xinghua GAO
Chinese Journal of Dermatology 2025;58(11):1020-1026
Objective:To evaluate the clinical equivalence between a domestic calcipotriol/betamethasone dipropionate ointment and the originator product in the treatment of stable plaque psoriasis.Methods:A multicenter, randomized, double-blind, three-arm, parallel-group, active- and placebo-controlled study was conducted, and 449 patients aged 18 - 65 years with stable plaque psoriasis were enrolled from 25 hospitals (such as the First Affiliated Hospital of China Medical University). Eligible patients had a baseline physician's global assessment (PGA) score of ≥ 3 points, baseline body surface area (BSA) involvement of 5% - 30%, and a target lesion psoriasis area and severity index (TL-PASI) for plaque elevation of ≥ 3 points. Participants were randomly assigned in a 2:2:1 ratio to the test group ( n = 179), reference group ( n = 180), and placebo group ( n = 90), and applied the domestic calcipotriol/betamethasone dipropionate ointment, originator product, and ointment base respectively, once daily in the evening for 4 weeks. Efficacy and safety were assessed at weeks 1, 2, and 4. The primary efficacy endpoints were the treatment success rates and clinical success rates in each group at week 4. The per-protocol set (PPS) was used for the primary efficacy analysis, and the intention-to-treat (ITT) set for supplementary efficacy analysis. Equivalence between the test and reference preparations was tested using the Cochran-Mantel-Haenszel method adjusted for randomization strata. Superiority of the test and reference preparations over the placebo was also tested. Measurement data were compared among the 3 groups using analysis of variance or non-parametric tests, while treatment success rates, clinical success rates, and incidence rates of adverse reactions were compared using the chi-square test. Results:The ITT, PPS, and safety sets included 447, 420, and 448 patients, respectively. In the ITT set, patients were aged 43.6 ± 12.8 years, including 320 (71.6%) males and 127 (28.4%) females, and the disease duration was 11.21 ± 9.05 years; 316 (70.7%) had a PGA score of 3 points and 131 (29.3%) had a PGA score of 4 - 5 points. No significant differences in the baseline characteristics (including age, sex, disease duration and disease severity) were observed among the 3 groups (all P > 0.05). Based on the PPS analysis, the treatment success rates were 57.9% (99/171) in the test group, 50.3% (86/171) in the reference group, and 7.7% (6/78) in the placebo group, and the clinical success rates were 57.9% (99/171), 50.3% (86/171), and 10.3% (8/78), respectively; both the test and reference groups were superior to the placebo group in both treatment and clinical success rates (all P < 0.001) ; the rate differences for treatment success (90% confidence interval [ CI]: -1.3% - 16.4%) and clinical success (90% CI: -1.3% - 16.3%) between the test and reference groups were entirely within the pre-defined equivalence margin (-20% - 20%). Subgroup analyses by baseline PGA scores: for patients with a baseline PGA score of 3 points, the treatment success rates in the test, reference, and placebo groups were 60.8% (73/120), 52.1% (62/119), and 11.1% (6/54), respectively, and the corresponding clinical success rates were 61.7% (74/120), 53.8% (64/119), and 13% (7/54), respectively; the test and reference groups did not differ significantly in treatment or clinical success rates (both P > 0.05), but both showed higher success rates than the placebo group (all P < 0.001) ; the results of statistical comparisons among the 3 groups in patients with a baseline PGA score of 4 - 5 points were consistent with those observed in patients with a baseline PGA score of 3 points. The percentage reductions in PGA and TL-PASI scores from baseline to weeks 1, 2, and 4 showed significant differences among the 3 groups, which were significantly higher in the test and reference groups than in the placebo group (all P < 0.001), but did not differ between the test and reference groups (all P > 0.05). The primary adverse reactions were local skin reactions, such as pruritus, pain, and erythema. The incidence rates of adverse reactions were 8.9% (16/179) in the test group, 7.3% (13/179) in the reference group, and 7.8% (7/90) in the placebo group, with no significant difference among the 3 groups ( P > 0.05) . Conclusions:The domestic calcipotriol/betamethasone dipropionate ointment demonstrated clinical equivalence to the originator product in the treatment of stable plaque psoriasis, and the two agents exhibited comparable efficacy for patients with varying degrees of disease severity, and were comparable in the speed and degree of clinical improvement, with similar favorable safety profiles.
5.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
6.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
7.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
8.Clinical efficacy and safety of a domestic calcipotriol/betamethasone dipropionate ointment in the treatment of stable plaque psoriasis: a multicenter, randomized, double-blind, controlled study
Lixin XIA ; Guang XIANG ; Qingchun DIAO ; Kun HUANG ; Shoumin ZHANG ; Shanshan LI ; Yumei LI ; Zhiqiang SONG ; Qing SUN ; Xiumin YANG ; Meng PAN ; Yuling SHI ; Shuping GUO ; Huiping WANG ; Tiechi LEI ; Xiaoyong ZHOU ; Songmei GENG ; Suchun HOU ; Juan SU ; Yong CUI ; Rixin CHEN ; Yanyan FENG ; Hongxia FENG ; Rushan XIA ; Zudong MENG ; Fang YIN ; Jingjing WANG ; Xinghua GAO
Chinese Journal of Dermatology 2025;58(11):1020-1026
Objective:To evaluate the clinical equivalence between a domestic calcipotriol/betamethasone dipropionate ointment and the originator product in the treatment of stable plaque psoriasis.Methods:A multicenter, randomized, double-blind, three-arm, parallel-group, active- and placebo-controlled study was conducted, and 449 patients aged 18 - 65 years with stable plaque psoriasis were enrolled from 25 hospitals (such as the First Affiliated Hospital of China Medical University). Eligible patients had a baseline physician's global assessment (PGA) score of ≥ 3 points, baseline body surface area (BSA) involvement of 5% - 30%, and a target lesion psoriasis area and severity index (TL-PASI) for plaque elevation of ≥ 3 points. Participants were randomly assigned in a 2:2:1 ratio to the test group ( n = 179), reference group ( n = 180), and placebo group ( n = 90), and applied the domestic calcipotriol/betamethasone dipropionate ointment, originator product, and ointment base respectively, once daily in the evening for 4 weeks. Efficacy and safety were assessed at weeks 1, 2, and 4. The primary efficacy endpoints were the treatment success rates and clinical success rates in each group at week 4. The per-protocol set (PPS) was used for the primary efficacy analysis, and the intention-to-treat (ITT) set for supplementary efficacy analysis. Equivalence between the test and reference preparations was tested using the Cochran-Mantel-Haenszel method adjusted for randomization strata. Superiority of the test and reference preparations over the placebo was also tested. Measurement data were compared among the 3 groups using analysis of variance or non-parametric tests, while treatment success rates, clinical success rates, and incidence rates of adverse reactions were compared using the chi-square test. Results:The ITT, PPS, and safety sets included 447, 420, and 448 patients, respectively. In the ITT set, patients were aged 43.6 ± 12.8 years, including 320 (71.6%) males and 127 (28.4%) females, and the disease duration was 11.21 ± 9.05 years; 316 (70.7%) had a PGA score of 3 points and 131 (29.3%) had a PGA score of 4 - 5 points. No significant differences in the baseline characteristics (including age, sex, disease duration and disease severity) were observed among the 3 groups (all P > 0.05). Based on the PPS analysis, the treatment success rates were 57.9% (99/171) in the test group, 50.3% (86/171) in the reference group, and 7.7% (6/78) in the placebo group, and the clinical success rates were 57.9% (99/171), 50.3% (86/171), and 10.3% (8/78), respectively; both the test and reference groups were superior to the placebo group in both treatment and clinical success rates (all P < 0.001) ; the rate differences for treatment success (90% confidence interval [ CI]: -1.3% - 16.4%) and clinical success (90% CI: -1.3% - 16.3%) between the test and reference groups were entirely within the pre-defined equivalence margin (-20% - 20%). Subgroup analyses by baseline PGA scores: for patients with a baseline PGA score of 3 points, the treatment success rates in the test, reference, and placebo groups were 60.8% (73/120), 52.1% (62/119), and 11.1% (6/54), respectively, and the corresponding clinical success rates were 61.7% (74/120), 53.8% (64/119), and 13% (7/54), respectively; the test and reference groups did not differ significantly in treatment or clinical success rates (both P > 0.05), but both showed higher success rates than the placebo group (all P < 0.001) ; the results of statistical comparisons among the 3 groups in patients with a baseline PGA score of 4 - 5 points were consistent with those observed in patients with a baseline PGA score of 3 points. The percentage reductions in PGA and TL-PASI scores from baseline to weeks 1, 2, and 4 showed significant differences among the 3 groups, which were significantly higher in the test and reference groups than in the placebo group (all P < 0.001), but did not differ between the test and reference groups (all P > 0.05). The primary adverse reactions were local skin reactions, such as pruritus, pain, and erythema. The incidence rates of adverse reactions were 8.9% (16/179) in the test group, 7.3% (13/179) in the reference group, and 7.8% (7/90) in the placebo group, with no significant difference among the 3 groups ( P > 0.05) . Conclusions:The domestic calcipotriol/betamethasone dipropionate ointment demonstrated clinical equivalence to the originator product in the treatment of stable plaque psoriasis, and the two agents exhibited comparable efficacy for patients with varying degrees of disease severity, and were comparable in the speed and degree of clinical improvement, with similar favorable safety profiles.
9.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
10.Evaluation of Hemolytic Performance of Cellulose Hemostatic Products
Qing-qing HOU ; Qin-lian JIAO ; Chun-xia QIAO ; Zi-ye WANG ; Xiao-yan WANG ; Wen-qian MA ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(9):1488-1495
Objective:To compare the differences in the evaluation of hemolysis performance of cellulose hemostatic materials using different detection methods and test media,and to explore a m ore reasonable testing plan for such products.Methods:Hemolysis tests were conducted on cellulose hemostatic materials using the absorbance measurement hemolysis method and hemoglobin concentration measurement hemolysis method in accordance with YY/T 1651.1-2019 standard.We compared the changes in hemolysis rate,pH value,and osmotic pressure under different experimental media.Results:Under the same experimental method,compared to SC,the hemolysis results using PBS as the extraction medium are smaller,and the changes in pH and osmotic pressure are closer to the normal range of human body changes.Conclusions:The changes in pH and osmotic pressure may be one of the reasons for the high hemolysis rate of cellulose hemostatic materials.Choosing PBS with buffering effect as the leaching medium may be more suitable for evaluating the hemolysis performance of cellulose hemostatic materials.

Result Analysis
Print
Save
E-mail