1.Diagnosis and treatment of acquired dermal macular hyperpigmentation
Chen WANG ; Yuecen DING ; Yaqi DONG ; Chengfeng ZHANG ; Leihong XIANG ; Zhongyi XU
Chinese Journal of Dermatology 2025;58(9):873-877
Acquired dermal macular hyperpigmentation (ADMH) is a group of diseases clinically characterized by grayish-black macules and patches, with pigment predominantly deposited in the dermis. ADMH includes Riehl's melanosis, lichen planus pigmentosus, and erythema dyschromicum perstans/ashy dermatosis. In light of the remarkable similarities in both morphological and histopathological characteristics among this group of diseases, the academic community has recently proposed the new nosological term "acquired dermal macular hyperpigmentation" to achieve integration and unified classification of these related disorders. This review comprehensively elaborates on advances in the diagnosis and treatment of ADMH, including clinical manifestations, dermoscopic findings, pathological characteristics, and treatment progress.
2.Clinical study of modified high tibial osteotomy combined with platelet-rich plasma in the treatment of moderate to severe knee osteoarthritis.
Xiao-Min LI ; Xiang-Dong TIAN ; Ye-Tong TAN ; Tian-Song DING
China Journal of Orthopaedics and Traumatology 2025;38(4):329-335
OBJECTIVE:
To evaluate the clinical efficacy of modified high tibial osteotomy combined with platelet-rich plasma in the treatment of moderate to severe knee osteoarthritis.
METHODS:
From January 2021 to March 2022, the clinical data of 60 patients with moderate to severe knee osteoarthritis admitted to the Third Affiliated Hospital of Beijing University of Chinese Medicine were analyzed. Among them, 30 patients were treated with modified tibia high osteotomy combined with platelet-rich plasma as the observation group, including 12 males and 18 females, aged from 51 to 74 years old, with an average age of (64.37±5.72) years old. The course of disease ranged from 1 to 7 years with an average of(3.43±1.41) years. Thirty patients were treated with modified high tibial osteotomy combined with sodium hyaluronate as control group, including 10 males and 20 females, aged from 50 to 78 years, with an average age of (64.33±8.18) years. The course of disease was 1 to 7 years with an average of(3.30±1.39) years. Knee X-rays were taken before surgery and at the last follow-up, and the changes of lower limb bearing-line ratio (WBLR), proximal medial tibial Angle (MPTA), femoro-tibial angle (FTA) and posterior tibial slope (PTS) were compared between the two times. Visual analogue scale (VAS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and Lysholm score were used to evaluate knee pain and functional changes before surgery and at 1, 3, and 6 months after surgery.
RESULTS:
The wounds of all patients healed in stage I after surgery. All 60 patients completed treatment and follow-up, with an average follow-up duration of (8.08±1.75) months, ranged from 6 to 12 months. No serious adverse events or complications occurred. At the last follow-up, WBLR, MPTA and FTA were significantly improved in both groups (P<0.05). At the last follow-up, there was no significant difference in PTS between the two groups compared with pre-operation(P>0.05). At the last follow-up, there were no significant differences in WBLR, MPTA, FTA and PTS between the observation group and the control group (P>0.05). The VAS scores, WOMAC scores and Lysholm scores of both groups were significantly Modified with time after operation (P<0.05). At 1, 3 and 6 months after operation, VAS score, WOMAC score and Lysholm score of the observation group were significantly better than those of the control group, with statistical significance (P<0.05).
CONCLUSION
For patients with moderate and severe knee osteoarthritis, modified high tibial osteotomy can significantly correct lower limb alignment, and combined with platelet-rich plasma therapy can further significantly relieve knee pain and improve knee function, the effect is better than combined with sodium hyaluronate.
Humans
;
Male
;
Female
;
Osteoarthritis, Knee/physiopathology*
;
Middle Aged
;
Osteotomy/methods*
;
Platelet-Rich Plasma
;
Aged
;
Tibia/surgery*
3.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
4.Diagnosis and treatment of acquired dermal macular hyperpigmentation
Chen WANG ; Yuecen DING ; Yaqi DONG ; Chengfeng ZHANG ; Leihong XIANG ; Zhongyi XU
Chinese Journal of Dermatology 2025;58(9):873-877
Acquired dermal macular hyperpigmentation (ADMH) is a group of diseases clinically characterized by grayish-black macules and patches, with pigment predominantly deposited in the dermis. ADMH includes Riehl's melanosis, lichen planus pigmentosus, and erythema dyschromicum perstans/ashy dermatosis. In light of the remarkable similarities in both morphological and histopathological characteristics among this group of diseases, the academic community has recently proposed the new nosological term "acquired dermal macular hyperpigmentation" to achieve integration and unified classification of these related disorders. This review comprehensively elaborates on advances in the diagnosis and treatment of ADMH, including clinical manifestations, dermoscopic findings, pathological characteristics, and treatment progress.
5.Architecture and Method Path of Party Building Leading the High-quality Development of Public Hospitals
Xiang LI ; Siyu LEI ; Dong DING
Chinese Hospital Management 2025;45(1):25-28
The high-quality development of public hospitals is the fundamental guarantee for the realization of the strategic task of ensuring people's health.In the development process of public hospitals in the new era,the institutional inertia of traditional decision-making,the complexity of contradictions caused by conflicts of interests,and the diversity of medical staff's ideologies are all constraints to the high-quality development of public hospitals.Based on that,from the perspective of public hospital business,on the one hand,a certain structural system should be reinforced for party building leading the high-quality development of public hospitals around the four dimensions of governance structure,medical service capacity,hospital precision management,and culture brand;on the other hand,relevant methods such as political guidance,organizational coverage,management optimization and cultural guidance should be supplied to explore a better path for party building leading the public hospitals' development through systemic reform,thus achieving the goal of high-quality development of public hospitals.
6.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
7.Architecture and Method Path of Party Building Leading the High-quality Development of Public Hospitals
Xiang LI ; Siyu LEI ; Dong DING
Chinese Hospital Management 2025;45(1):25-28
The high-quality development of public hospitals is the fundamental guarantee for the realization of the strategic task of ensuring people's health.In the development process of public hospitals in the new era,the institutional inertia of traditional decision-making,the complexity of contradictions caused by conflicts of interests,and the diversity of medical staff's ideologies are all constraints to the high-quality development of public hospitals.Based on that,from the perspective of public hospital business,on the one hand,a certain structural system should be reinforced for party building leading the high-quality development of public hospitals around the four dimensions of governance structure,medical service capacity,hospital precision management,and culture brand;on the other hand,relevant methods such as political guidance,organizational coverage,management optimization and cultural guidance should be supplied to explore a better path for party building leading the public hospitals' development through systemic reform,thus achieving the goal of high-quality development of public hospitals.
8.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.
9.Analysis of Organized Scientific Research Practice in an Affiliated Hospital of University
Ning DING ; Yu HU ; Danyun DAI ; Jiancai WU ; Can XIANG ; Ming ZHANG ; Dong XU
Chinese Hospital Management 2024;44(2):87-90
Taking Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology as an example,it discusses the basic ideas and innovative practices of project organization from"passive order taking"to"active planning",platform construction from"free growth"to"directional cultivation",team construction from"wearing hats"to"focusing on actual combat",and achievement transformation from"resource guidance"to"comprehensive policy".It puts forward some suggestions that hospitals should play the leading role of"national team"in organizing scientific research and innovation practice,pay attention to the docking of national strategy,the linkage of university resources.
10.Content determination of seventeen amino acids in Gualoupi Injection and its intermediates and research on their change laws
Xiang TAO ; Jing-Xian ZHANG ; Qing HU ; Jian SUN ; Ying DONG ; Jin-Guo DING ; Hong YU ; Ying-Ying SHEN ; Xiu-Hong MAO ; Shen JI
Chinese Traditional Patent Medicine 2024;46(3):709-717
AIM To determine the contents of aspartic acid,glutamic acid,serine,glycine,threonine,citrulline,arginine,alanine,γ-amino-butyric acid,tyrosine,valine,phenlalanine,isoleucine,ornithine,leucine,lysine and proline in Gualoupi Injection and its intermediates,and to analyze their change laws.METHODS The OPA-FMOC online derivatization analysis was performed on a 45℃ thermostatic Waters XBridge C18 column(4.6 mm×100 mm,3.5 μm),with the mobile phase comprising of phosphate buffer solution-[methanol-acetonitrile-water(45 : 45 : 10)]flowing at 1 mL/min in a gradient elution manner,and the detection wavelengths were set at 262,338 nm.Principal component analysis and heatmap analysis were adopted in chemical pattern recognition for the corresponding intermediates in ten processes of six batches of samples.RESULTS Seventeen amino acids showed good linear relationships within their own ranges(R2>0.998 0),whose average recoveries were 83.4%-119.5%with the RSDs of 0.91%-7.94%.Different batches of samples in the same process were clustered,and the corresponding intermediates in different processed were clustered into three groups.Alcohol precipitation and cation exchange column demonstrated the biggest influences on amino acid composition.CONCLUSION This experiment can provide important references for the critical factors on quality control of Gualoupi Injection,thus ensure the stability and uniformity of final product.

Result Analysis
Print
Save
E-mail