1.Precise suctioning scheme for intravenous drug dispensing based on vial dispensing robot
Xian-tao QIN ; Tai-min LUO ; Li YANG ; Peng GAO ; Jian-rong CUI
Chinese Medical Equipment Journal 2025;46(9):45-51
Objective To propose a precise suctioning scheme for intravenous drug dispensing based on the vial dispensing robot to enhance the quality of finished infusion.Methods Six kinds of typical representative vial drugs were selected as the research objects,including pantoprazole sodium for injection,papaverine hydrochloride for injection,cefuroxime sodium for injection,Bozhi Glycopeptide Injection,Esomeprazole Sodium for Injection and Methylprednisolone Sodium Succinate for injection.The optimal suction speed was determined by studying the relationship between the size parameters of vials and the suction speed of robot dispensing,which was used to carry out drug dispensing with the vial dispensing robot to verify whether the minimum drug residue could be obtained with the speed.The drug residue was compared with that by manual dispensing.SPSS 24.0 and Excel 2021 were applied to statistical analysis.Results The optimal suction efficiency and minimized drug residue could be got with the depth of the syringe needle hole into the rubber plug(X)less than the height of the rubber plug(H)and the optimal suction speed(Vs)of 7.48 mm/s;the suction efficiency could be ensured without air drawn in when X not less than H and Vs ranging from 10.64 to 39.31 mm/s.The mean values of the drug residue by the robot were all lower than those by manual dispensing,with the differences being statistically significant(P<0.05).Conclusion The proposed scheme can be used for optimizing the parameters of the vial vial dispensing robot to obtain infusion solution with high stability and reliability,which promotes standardization and normalization of intravenous infusion dispensing process.[Chinese Medical Equipment Journal,2025,46(9):45-51]
2.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.
3.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.
4.Precise suctioning scheme for intravenous drug dispensing based on vial dispensing robot
Xian-tao QIN ; Tai-min LUO ; Li YANG ; Peng GAO ; Jian-rong CUI
Chinese Medical Equipment Journal 2025;46(9):45-51
Objective To propose a precise suctioning scheme for intravenous drug dispensing based on the vial dispensing robot to enhance the quality of finished infusion.Methods Six kinds of typical representative vial drugs were selected as the research objects,including pantoprazole sodium for injection,papaverine hydrochloride for injection,cefuroxime sodium for injection,Bozhi Glycopeptide Injection,Esomeprazole Sodium for Injection and Methylprednisolone Sodium Succinate for injection.The optimal suction speed was determined by studying the relationship between the size parameters of vials and the suction speed of robot dispensing,which was used to carry out drug dispensing with the vial dispensing robot to verify whether the minimum drug residue could be obtained with the speed.The drug residue was compared with that by manual dispensing.SPSS 24.0 and Excel 2021 were applied to statistical analysis.Results The optimal suction efficiency and minimized drug residue could be got with the depth of the syringe needle hole into the rubber plug(X)less than the height of the rubber plug(H)and the optimal suction speed(Vs)of 7.48 mm/s;the suction efficiency could be ensured without air drawn in when X not less than H and Vs ranging from 10.64 to 39.31 mm/s.The mean values of the drug residue by the robot were all lower than those by manual dispensing,with the differences being statistically significant(P<0.05).Conclusion The proposed scheme can be used for optimizing the parameters of the vial vial dispensing robot to obtain infusion solution with high stability and reliability,which promotes standardization and normalization of intravenous infusion dispensing process.[Chinese Medical Equipment Journal,2025,46(9):45-51]
5.Management and operation of extra-large Fangcang hospitals: experience and lessons from containing the highly contagious SARS-CoV-2 Omicron in Shanghai, China.
Yun XIAN ; Chenhao YU ; Minjie CHEN ; Lin ZHANG ; Xinyi ZHENG ; Shijian LI ; Erzhen CHEN ; Zhongwan CHEN ; Weihua CHEN ; Chaoying WANG ; Qingrong XU ; Tao HAN ; Weidong YE ; Wenyi XU ; Xu ZHUANG ; Yu ZHENG ; Min CHEN ; Jun QIN ; Yu FENG ; Shun WEI ; Yiling FAN ; Zhiruo ZHANG ; Junhua ZHENG
Frontiers of Medicine 2023;17(1):165-171
6.Study on the diagnostic value of transient elastography, APRI and FIB-4 for liver fibrosis in children with non-alcoholic fatty liver disease.
Shu Li HE ; Shuang Jie LI ; Min LIU ; Wen Xian OUYANG ; Wei Jian CHEN ; Xi ZHENG ; Tao JIANG ; Yan Fang TAN ; Zhen KANG ; Xiao Mei QIN ; Ying YU
Chinese Journal of Hepatology 2022;30(1):81-86
Objective: To evaluate the diagnostic value of transient elastography, aspartate aminotransferase-to-platelet ratio index (APRI), and fibrosis index based on 4 factors (FIB-4) for liver fibrosis in children with non-alcoholic fatty liver disease (NAFLD). Methods: A retrospective study was conducted on 100 cases of nonalcoholic fatty liver disease in Hunan Children's Hospital between August 2015 to October 2020 to collect liver tissue pathological and clinical data. The receiver operating characteristic curve (ROC curve) was used to analyze the diagnostic value of liver stiffness measurement (LSM), APRI and FIB-4 in the diagnosis of different stages of liver fibrosis caused by NAFLD in children. Results: The area under the ROC curve (AUC) value of LSM, APRI and FIB-4 for diagnosing liver fibrosis (S≥1) were 0.701 [95% confidence interval (CI): 0.579 ~ 0.822, P = 0.011], 0.606 (95%CI: 0.436 ~ 0.775, P = 0.182), and 0.568 (95%CI: 0.397 ~ 0.740, P = 0.387), respectively. The best cut-off values were 6.65 kPa, 21.20, and 0.18, respectively. The AUCs value of LSM, APRI, and FIB-4 for diagnosing significant liver fibrosis (S≥ 2) were 0.660 (95% CI: 0.552 ~ 0.768, P = 0.006), 0.578 (95% CI: 0.464 ~ 0.691, P = 0.182) and 0.541 (95% CI: 0.427 ~ 0.655, P = 0.482), respectively. The best cut-off values were 7.35kpa, 24.78 and 0.22, respectively. The AUCs value of LSM, APRI and FIB-4 for the diagnosis of advanced liver fibrosis (S≥ 3) were 0.639 (95% CI: 0.446 ~ 0.832, P = 0.134), 0.613 (95% CI: 0.447 ~ 0.779, P = 0.223) and 0.587 (95% CI: 0.411 ~ 0.764, P = 0.346), respectively. The best cut-off values were 8.55kpa, 26.66 and 0.27, respectively. Conclusion: The transient elastography technique has a better diagnostic value than APRI and FIB-4 for liver fibrosis in children with NAFLD.
Aspartate Aminotransferases
;
Biomarkers
;
Child
;
Elasticity Imaging Techniques
;
Humans
;
Liver/pathology*
;
Liver Cirrhosis/pathology*
;
Liver Function Tests
;
Non-alcoholic Fatty Liver Disease/pathology*
;
ROC Curve
;
Retrospective Studies
7.Assessment of myocardial injury in neonates born to pregnant women with pregnancy complicated by severe preeclampsia by myocardial work indices: a prospective study.
Hui-Yun CHEN ; Tao PAN ; Hong LI ; Qiu-Qin XU ; Fang-Can SUN ; Bing HAN ; Xin-Xian GU
Chinese Journal of Contemporary Pediatrics 2022;24(2):155-161
OBJECTIVES:
To evaluate myocardial injury in neonates born to pregnant women with pregnancy complicated by severe preeclampsia by myocardial work indices.
METHODS:
A prospective cohort study was performed on 25 preterm infants born to the pregnant women with severe preeclampsia from June 2020 to April 2021 (severe preeclampsia group), and 25 preterm infants born to the pregnant women without severe complications in pregnancy were enrolled as the control group. Echocardiography was performed within 24 hours and at 48-72 hours and 14-28 days after birth to measure conventional parameters. Two-dimensional speckle-tracking echocardiography was performed to construct a noninvasive left ventricular pressure-strain loop based on two-dimensional myocardial strain and left ventricular systolic pressure noninvasively measured, so as to calculate myocardial work indices.
RESULTS:
Compared with the control group, the severe preeclampsia group had significant reductions in left ventricular global work index and global constructive work within 24 hours after birth (P<0.05), a significant reduction in left ventricular global work efficiency and a significant increase in global waste work at 48-72 hours after birth (P<0.05), and a significant reduction in left ventricular global work efficiency at 14-28 days after birth (P<0.05).
CONCLUSIONS
Subclinical myocardial injury persists in the neonatal period in preterm infants born to pregnant women with severe preeclampsia.
Echocardiography/methods*
;
Female
;
Humans
;
Infant
;
Infant, Newborn
;
Infant, Premature
;
Pre-Eclampsia
;
Pregnancy
;
Pregnant Women
;
Prospective Studies
8.A 14-year multi-institutional collaborative study of Chinese pelvic floor surgical procedures related to pelvic organ prolapse.
Zhi-Jing SUN ; Xiu-Qi WANG ; Jing-He LANG ; Tao XU ; Yong-Xian LU ; Ke-Qin HUA ; Jin-Song HAN ; Huai-Fang LI ; Xiao-Wen TONG ; Ping WANG ; Jian-Liu WANG ; Xin YANG ; Xiang-Hua HUANG ; Pei-Shu LIU ; Yan-Feng SONG ; Hang-Mei JIN ; Jing-Yan XIE ; Lu-Wen WANG ; Qing-Kai WU ; Jian GONG ; Yan WANG ; Li-Qun WANG ; Zhao-Ai LI ; Hui-Cheng XU ; Zhi-Jun XIA ; Li-Na GU ; Qing LIU ; Lan ZHU
Chinese Medical Journal 2021;134(2):200-205
BACKGROUND:
It has been a global trend that increasing complications related to pelvic floor surgeries have been reported over time. The current study aimed to outline the development of Chinese pelvic floor surgeries related to pelvic organ prolapse (POP) over the past 14 years and investigate the potential influence of enhanced monitoring conducted by the Chinese Association of Urogynecology since 2011.
METHODS:
A total of 44,594 women with POP who underwent pelvic floor surgeries between October 1, 2004 and September 30, 2018 were included from 22 tertiary academic medical centers. The data were reported voluntarily and obtained from a database. We compared the proportion of each procedure in the 7 years before and 7 years after September 30, 2011. The data were analyzed by performing Z test (one-sided).
RESULTS:
The number of different procedures during October 1, 2011-September 30, 2018 was more than twice that during October 1, 2004-September 30, 2011. Regarding pelvic floor surgeries related to POP, the rate of synthetic mesh procedures increased from 38.1% (5298/13,906) during October 1, 2004-September 30, 2011 to 46.0% (14,107/30,688) during October 1, 2011-September 30, 2018, whereas the rate of non-mesh procedures decreased from 61.9% (8608/13,906) to 54.0% (16,581/30,688) (Z = 15.53, P < 0.001). Regarding synthetic mesh surgeries related to POP, the rates of transvaginal placement of surgical mesh (TVM) procedures decreased from 94.1% (4983/5298) to 82.2% (11,603/14,107) (Z = 20.79, P < 0.001), but the rate of laparoscopic sacrocolpopexy (LSC) procedures increased from 5.9% (315/5298) to 17.8% (2504/14,107).
CONCLUSIONS:
The rate of synthetic mesh procedures increased while that of non-mesh procedures decreased significantly. The rate of TVM procedures decreased while the rate of LSC procedures increased significantly.
TRIAL REGISTRATION NUMBER
NCT03620565, https://register.clinicaltrials.gov.
China
;
Female
;
Gynecologic Surgical Procedures/adverse effects*
;
Humans
;
Pelvic Floor/surgery*
;
Pelvic Organ Prolapse/surgery*
;
Surgical Mesh/adverse effects*
;
Treatment Outcome
;
Vagina
9.Effects of Bilateral Arm Transcutaneous Electrical Acupoint Stimulation on Upper Limb Function for Subacute Stroke Hemiplegic Patients
Dao-jin XIA ; Xian-shi XIONG ; Yu-qin LÜ ; Rong FAN ; Tao PENG
Chinese Journal of Rehabilitation Theory and Practice 2021;27(11):1318-1322
Objective:To explore the effects of bilateral arm transcutaneous electrical acupoint stimulation (TEAS) based on mirror therapy (MT) on upper limb function of subacute stroke hemiplegic patients. Methods:From September, 2017 to October, 2019, 48 subacute stroke hemiplegic patients were randomly divided into control group (
10. Projections from Infralimbic Cortex to Paraventricular Thalamus Mediate Fear Extinction Retrieval
Yan TAO ; Cheng-Yun CAI ; Jia-Yun XIAN ; Xiao-Lin KOU ; Yu-Hui LIN ; Cheng QIN ; Hai-Yin WU ; Lei CHANG ; Chun-Xia LUO ; Dong-Ya ZHU ; Dong-Ya ZHU ; Dong-Ya ZHU
Neuroscience Bulletin 2021;37(2):229-241
The paraventricular nucleus of the thalamus (PVT), which serves as a hub, receives dense projections from the medial prefrontal cortex (mPFC) and projects to the lateral division of central amygdala (CeL). The infralimbic (IL) cortex plays a crucial role in encoding and recalling fear extinction memory. Here, we found that neurons in the PVT and IL were strongly activated during fear extinction retrieval. Silencing PVT neurons inhibited extinction retrieval at recent time point (24 h after extinction), while activating them promoted extinction retrieval at remote time point (7 d after extinction), suggesting a critical role of the PVT in extinction retrieval. In the mPFC-PVT circuit, projections from IL rather than prelimbic cortex to the PVT were dominant, and disrupting the IL-PVT projection suppressed extinction retrieval. Moreover, the axons of PVT neurons preferentially projected to the CeL. Silencing the PVT-CeL circuit also suppressed extinction retrieval. Together, our findings reveal a new neural circuit for fear extinction retrieval outside the classical IL-amygdala circuit.

Result Analysis
Print
Save
E-mail