1.Propensity score matched comparison of pancreatoduodenectomy with pancreatogastrostomy versus pancreatojejunostomy: A single institution experience shifting from pancreatogastrostomy to pancreatojejunostomy
Teik Wen LIM ; Sabrina Hui Xian CHEOK ; Yvette CHONG ; Darren Weiquan CHUA ; Ek Khoon TAN ; Jin Yao TEO ; Ye-Xin KOH ; Peng Chung CHEOW ; Pierce Kah Hoe CHOW ; London Lucien Peng Jin OOI ; Alexander Yaw Fui CHUNG ; Brian Kim Poh GOH
Annals of Hepato-Biliary-Pancreatic Surgery 2026;30(1):91-98
Background:
s/Aims: Postoperative pancreatic fistulas (POPF) remain a major cause of morbidity and mortality following pancreatoduodenectomy (PD). Pancreatogastrostomy (PG) and pancreatojejunostomy (PJ) are the two most commonly used reconstruction techniques, yet evidence favoring one over the other is inconclusive. This study evaluates postoperative outcomes following open PD at a single institution that transitioned from PG to PJ as the preferred reconstruction method.
Methods:
This retrospective comparative study included patients who underwent PD between April 2005 and August 2022. Of 757 patients identified, 522 met the inclusion criteria. Propensity score matching (PSM) was performed to adjust for clinically relevant covariates. Primary endpoints were clinically relevant (CR) POPF (grade B/C) and Clavien–Dindo (CD) grade ≥ 3 POPFs. Secondary outcomes included post-pancreatectomy hemorrhage (PPH), delayed gastric emptying (DGE), systemic complications, length of hospital stay, and mortality.
Results:
Overall, CR-POPF and CD grade ≥ 3 POPFs occurred in 21.3% and 8.0% of patients, respectively. Thirty-day and in-hospital mortality rates were 3.1% and 4.2%. After PSM, 368 patients (184 PG and 184 PJ) were analyzed. Grade B POPFs were more frequent following PJ than PG (24.5% vs. 15.8%, p < 0.001). Although CR-POPF and CD grade ≥ 3 POPFs were numerically higher in the PJ group, differences were not statistically significant. In contrast, DGE, PPH, and in-hospital mortality were significantly higher following PG (37.0% vs. 25.0%, p = 0.025; 16.3% vs. 8.7%, p = 0.025; and 7.6% vs. 2.7%, p = 0.049, respectively).
Conclusions
PG was associated with a lower incidence of grade B POPFs but higher rates of DGE, PPH, and in-hospital mortality.
2.Advancements in the role of iris parameters in implantable collamer lens implantation
Huihui JIN ; Jiaqing HUANG ; Xian WU ; Yingjie NI ; Chaoyang HONG ; Peijin QIU ; Ting SHEN
International Eye Science 2025;25(7):1037-1045
Phakic intraocular lens implantation has become one of the important means of correcting refractive errors today. Among them,the implantable collamer lens(ICL)is favored for its wide range of correction, excellent optical quality, and high safety, but the risks of postoperative complications such as glaucoma and anterior subcapsular opacification still exist. Vault is an important indicator for evaluating the safety after ICL implantation, and its ideal state is crucial for preventing complications. Studies have shown that iris morphology has a significant impact on vault. In order to further optimize surgical outcomes and improve surgical safety, this review comprehensively reviews the research progress of iris-related parameters in ICL implantation and discusses the importance of various parameters in preoperative evaluation and postoperative follow-up.
3.Effect of different probes endoscopic ultrasonography on the diameter measurement of gastrointestinal submucosal tumors
Ping HUANG ; Xian GUO ; Chao-qun LI ; Jin LIU ; Xu-biao NIE ; Hui LIN ; Jian-ying BAI
Journal of Regional Anatomy and Operative Surgery 2025;34(10):908-912
Objective To explore the effect of endoscopic ultrasonography(EUS)with different probes on the measurement of gastrointestinal submucosal tumor(SMT)diameter.Methods The clinical data of 356 patients(with a total of 372 lesions)initially diagnosed as SMT by EUS at the Second Affiliated Hospital of Army Medical University from January 2023 to June 2024 were analyzed retrospectively.The basic characteristics of the origin layers and pathological distribution of SMT were analyzed.The differences between the EUS-measured diameters and the actual diameters of SMT at different diameter ranges of lesions were compared.Taking the postoperative pathological diagnosis results as the gold standard,the effects of different clinicopathological features and probe types on the relative error in EUS-measured diameters of SMT were analyzed.Results Among the 372 gastrointestinal SMT lesions,lesions were more frequent in female patients,gastric lesions was the most common,and leiomyoma was the predominant pathological type.The accuracy of EUS in diagnosing SMT was 94.4%.A statistically significant difference was observed between the EUS-measured diameters and the actual diameters of SMT(P<0.05).There were significantly differences in various ranges of lesions between the EUS-measured diameters and the actual diameters(P<0.05).The gender,age,lesion location,and pathological type had no significant effect on the relative error of EUS-measured diameters(P>0.05);while probe types had a significant effect on the relative error of EUS-measured diameters(P<0.05).For lesions with an actual diameter of 2.0 to 3.9 cm,the relative error of SMT diameters measured by small-probe EUS was significantly greater than that by large-probe EUS(P<0.05).Conclusion Large-probe EUS exhibits a smaller relative error in measuring the diameter of SMT with a diameter of≥2.0 cm.Therefore,large-probe EUS is recommended for the examination of SMT with an estimated diameter exceeding 2.0 cm.
4.Chemical constituents from ethyl acetate fraction of Balanophora harlandii and their tyrosinase inhibitory activity
Zhang-xian CHEN ; Hai-ming WANG ; Yun-tao ZHANG ; Mao-xin DENG ; Kui-lin ZHU ; Jin-lian ZOU ; Jian WANG ; Shan-shan WEI ; Hong-ping HE ; Fa-wu DONG
Chinese Traditional Patent Medicine 2025;47(10):3290-3297
AIM To study the chemical constituents from ethyl acetate fraction of Balanophora harlandii Hook.f.and their tyrosinase inhibitory activity.METHODS Separation and purification were performed using silica gel,MCI,ODS,Sephadex LH-20 and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.The monophenolase inhibitory activity was determined by the tyrosinase-catalyzed oxidation of L-tyrosine.RESULTS Twenty-four compounds were isolated and identified as sesamin(1),methyl caffeate(2),quercetin(3),5,7-dihydroxychromanone(4),methyl 3,4-dihydroxybenzoate(5),esculetin(6),kaempferol(7),naringenin(8),pyrogallic acid(9),pinosylvin(10),methyl propionate(11),caffeic acid(12),saccharinol(13),ferulic acid(14),trans-p-hydroxycinnamic acid(15),cinnamic acid(16),vanillic acid(17),vanillin(18),4-hydroxyacetophenone(19),4-hydroxybenzaldehyde(20),apigenin(21),(-)-isolariciresinol(22),(-)-secoisolariciresinol(23)and meso-2,3-di(3′,4′-methylenedioxybenzyl)butane-1,4-diol(24).The IC50 values of compounds 3,5,7,8,19,and 20 ranged from(0.246 5±0.028 3)to(1.278 2±0.021 3)mmol/L.CONCLUSION Compounds 1-9、11、15、17-21、24 are isolated from this plant for the first time,and 1,6,9,17-19,24 are first isolated from genus Balanophora.Compounds 3、5、7、8、19 and 20 have tyrosinase inhibitory activity.
5.Comparison of left ventricular reverse remodeling and prognosis after transcatheter aortic valve replacement in aortic stenosis and mixed aortic valve disease
Meng SUN ; Lu-lin CHEN ; Jing-yun BAI ; Li-jie YAN ; Jing-jing LIU ; Xian-wei FAN ; Xue-jie LI ; Juan HU ; Jin-tao WU ; Hai-tao YANG
Chinese Journal of Interventional Cardiology 2025;33(2):71-78
Objective To evaluate the effects of transcatheter aortic valve replacement(TAVR)on left ventricular reverse remodeling(LVRR)and outcomes in patients with mixed aortic valve disease(MAVD)and predominant aortic stenosis(AS).Methods Patients undergoing TAVR at our center between January 2020 and December 2022 were enrolled consecutively.Propensity score matching(PSM)(1∶1 ratio)was used to reduce selection bias.Transthoracic echocardiography(TTE)was used to monitor left ventricular ejection fraction(LVEF)and other structural parameters over time.The study outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes.Linear mixed-effects models and logistic regression were utilized for comparing echocardiographic changes across groups and identifying independent risk factors for no-LVRR,respectively.Results After PSM,126 patients were included.MAVD group exhibited larger structural parameters(left ventricular end-systolic/end-diastolic diameter and volume,left ventricular mass index)and a lower left ventricular ejection fraction(LVEF)(all P<0.05).However,more pronounced improvements in left ventricular structure and hemodynamics were observed during follow-up.Multivariate logistic regression analysis indicated that the left ventricular mass index(LVMI)was an independent predictor of left ventricular reverse remodeling(LVRR)after TAVR,whereas persistent moderate or greater mitral regurgitation(MR)and paravalvular leak(PVL)significantly reduced the incidence of LVRR.During a median follow-up period of 23 months,a total of 31 endpoint events occurred,and there was no statistically significant difference in long-term prognosis between the two groups(Log-rank P=0.330).Conclusions Compared to patients in the AS group,those in the MAVD group exhibited more severe left ventricular remodeling before TAVR.However,more significant LVRR was observed during postoperative follow-up.Additionally,the long-term prognosis was comparable between the two groups.
6.Design and application of positive and negative pressure sequential irrigation suction device
Kun-feng SANG ; Xian-jin ZHONG ; Jia-li HUANG
Chinese Medical Equipment Journal 2025;46(1):114-117
Objective To design a positive and negative pressure sequential irrigation suction device and explore its efficacy when applied to unblocking nasoenteric tubes.Methods The device consisted of a positive-pressure irrigation component,a negative-pressure suction component,a three-way adapter and a precise unblocker.The positive-pressure irrigation compo-nent was composed of a positive-pressure irrigation unit,a positive pressure regulator,a pressure sensor,a pressure bag and etc;the negative-pressure suction component was made up of a negative-pressure suction unit,a negative pressure regulator,a negative-pressure gauge,a negative-pressure bottle and etc.The pressure bag was hollow cylinder-shaped,and made of ordinary polyvinyl chloride for its inner layer and acrylonitrile-styrene-butadiene copolymer for its outer layer.Sixty patients with nasoenteric tube blockage were selected and randomly divided into a control group and an observation group,with 30 cases in each group.Irrigation suction was carried out with a 10 mL syringe for the control group and with the device for the observation group,and then unblocking was performed with lukewarm water between 38 and 40 degrees.The two groups were compared in terms of the unblocking efficacy,time required for unblocking and the days and cost of nutritional support.SPSS 22.0 software was used for statistical analysis.Results The observation group gained advantages over the control group in terms of the total effective rate(93.3%vs 73.4%),unblocking efficacy,time required for unblocking((7.63±4.97)min vs(10.73±4.57)min),days of nutritional support((10.07±3.07)d vs(13.03±4.05)d)and cost of nutritional support((3 180±260)yuan vs(4 550±660)yuan).Conclusion The device developed effectively enhances the efficacy for unblocking nasoenteric tubes,shortens the time required and decreases the days and cost of nutritional support,and thus is worthy promoting practi-cally.[Chinese Medical Equipment Journal,2025,46(1):114-117]
7.Effect of different probes endoscopic ultrasonography on the diameter measurement of gastrointestinal submucosal tumors
Ping HUANG ; Xian GUO ; Chao-qun LI ; Jin LIU ; Xu-biao NIE ; Hui LIN ; Jian-ying BAI
Journal of Regional Anatomy and Operative Surgery 2025;34(10):908-912
Objective To explore the effect of endoscopic ultrasonography(EUS)with different probes on the measurement of gastrointestinal submucosal tumor(SMT)diameter.Methods The clinical data of 356 patients(with a total of 372 lesions)initially diagnosed as SMT by EUS at the Second Affiliated Hospital of Army Medical University from January 2023 to June 2024 were analyzed retrospectively.The basic characteristics of the origin layers and pathological distribution of SMT were analyzed.The differences between the EUS-measured diameters and the actual diameters of SMT at different diameter ranges of lesions were compared.Taking the postoperative pathological diagnosis results as the gold standard,the effects of different clinicopathological features and probe types on the relative error in EUS-measured diameters of SMT were analyzed.Results Among the 372 gastrointestinal SMT lesions,lesions were more frequent in female patients,gastric lesions was the most common,and leiomyoma was the predominant pathological type.The accuracy of EUS in diagnosing SMT was 94.4%.A statistically significant difference was observed between the EUS-measured diameters and the actual diameters of SMT(P<0.05).There were significantly differences in various ranges of lesions between the EUS-measured diameters and the actual diameters(P<0.05).The gender,age,lesion location,and pathological type had no significant effect on the relative error of EUS-measured diameters(P>0.05);while probe types had a significant effect on the relative error of EUS-measured diameters(P<0.05).For lesions with an actual diameter of 2.0 to 3.9 cm,the relative error of SMT diameters measured by small-probe EUS was significantly greater than that by large-probe EUS(P<0.05).Conclusion Large-probe EUS exhibits a smaller relative error in measuring the diameter of SMT with a diameter of≥2.0 cm.Therefore,large-probe EUS is recommended for the examination of SMT with an estimated diameter exceeding 2.0 cm.
8.Problems and suggestions for minor purchasing of medical equipment
Xian-ju YUAN ; Fei-ba CHANG ; Yong CHEN ; Cheng-qun MA ; Jia TAN ; Xi GUO ; Jin-chuan HAN
Chinese Medical Equipment Journal 2025;46(8):91-95
The minor purchasing process and mode of some hospital were introduced,and the implementation of the hospital's minor purchasing projects in the past year was analyzed.The causes for high failure rate of purchasing were pointed out including long interval between project creation and procurement,unreasonable demand presentation,insufficient demand demonstration and lack of active participation of suppliers.Some suggestions were put forward such as timely adjustment of demands,strengthening of demand demonstration,improvement of supplier motivation and enhancement of procurement process management,which were of great significance for increasing the success rate of minor purchasing of the hospital.[Chinese Medical Equipment Journal,2025,46(8):91-95]
9.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
10.Effect of Modified Autologous Skull Defect Repair in Patients with Traumatic Brain Injury and its Influence on Neurological Function and Living Ability
Bin WANG ; Jin ZHU ; Biao YUAN ; Yu-ping TANG ; Yang SHEN ; Xian-jun ZHANG
Progress in Modern Biomedicine 2025;25(18):2949-2955
Objective:To observe the effect of modified autologous skull defect repair in patients with traumatic brain injury and its influence on neurological function and living ability.Methods:104 patients with traumatic brain injury who were admitted to our hospital from March 2022 to August 2024 were included,they were divided into Group A[37 cases,poly ether ether ketone(PEEK)skull defect repair],Group B(35 cases,traditional titanium mesh skull defect repair),and Group C(32 cases,modified autologous skull defect repair).Perioperative indicators,neurological function,activity of daily living,quality of life,satisfaction,and incidence of postoperative complications were compared among three groups.Results:There were no differences in the operation time,operation blood loss and postoperative hospital stay among the three groups(P>0.05).The hospitalization costs of Group A,Group B and Group C decreased successively(P<0.05).Activity of Daily Living(ADL)scores at 3 and 6 months after surgery increased among three groups,while National Institutes of Health Stroke Scale(NIHSS)scores decreased(P<0.05).There was no significant difference in physiological function,social function,psychological function,and material life among the three groups at 6 months after surgery(P>0.05).The overall satisfaction rate in Group C was higher than that of Group A and Group B(P<0.05).The overall incidence of complications in Group C was lower than that in Group A and Group B(P<0.05).Conclusion:PEEK,traditional titanium mesh,and modified autologous skull are used in skull defect repair,operation time,operation blood loss and postoperative hospital stay are comparable,they can also reduce neurological function damage,improve living ability,and enhance the quality of life of patients,however,PEEK is relatively expensive,the satisfaction of traditional titanium mesh is low,andincidence of postoperative complications are relatively high.

Result Analysis
Print
Save
E-mail