1.Correlation between bone mass loss and incidence of knee osteoarthritis in the elderly community-based population.
Chen-Jie XIA ; Jin LI ; Xiang LI ; Ke ZHOU ; Liang FANG ; Hong-Ting JIN ; Pei-Jian TONG
China Journal of Orthopaedics and Traumatology 2025;38(4):358-363
OBJECTIVE:
To explore the epidemiological characteristics of knee osteoarthritis (KOA) among the elderly in the community, and its correlation with bone mass loss.
METHODS:
A cross-sectional study was conducted on elderly community population over 50 year old from 12 community health service centers in Zhejiang province. Their gender, age, body mass index (BMI), T value and KOA diagnosis were collected using face to face questionnaire survey. Univariate regression was used to analyze the influence of age, gender, BMI and bone loss on KOA. Logistic multivariate regression model was used to analyze the independent effect of bone mass loss on KOA.
RESULTS:
Among 4 173 subjects in this study, 1 710 of them were had a KOA. The prevalence rate was 40.9%. The mean age, the proportion of females and the mean BMI in KOA patients were (65.5±3.8) years old, 67.7%(1 158/1 710) and(24.59±1.28) kg·m-2, respectively, which were significantly higher than (58.5±3.2) years old, 51.3%(1 263/2 463), and (23.48±1.25) kg·m-2 in non-KOA subjects (P<0.001). In the population aged from 60 to 69 years old, the influence of osteopenia and osteoporosis on the prevalence of KOA was[OR=1.21, 95%CI(1.00, 1.46), P=0.053 2], [OR=1.42, 95%CI(1.14, 1.78), P=0.002 2]. The influence of male and female osteoporosis on the prevalence of KOA was [OR=1.52, 95%CI(1.16, 1.99), P=0.002 7] and [OR=1.87, 95%CI(1.51, 2.32), P<0.000 1], respectively. In the population of 24 kg·m-2≤BMI<28 kg·m-2, the influence of osteopenia and osteoporosis on the prevalence of KOA was [OR=1.47, 95%CI(1.21, 1.80), P=0.000 1], [OR=2.69, 95%CI(2.11, 3.42), P<0.000 1], respectively. After controlling the confounding factors of age, gender and BMI, compared with people with normal bone mass, the effect of osteopenia on the prevalence of KOA was [OR=1.34, 95%CI(1.08, 1.67), P=0.009 2], and the effect of osteoporosis on the prevalence of KOA was [OR=1.38, 95%CI(1.06, 1.79), P=0.017 9].
CONCLUSION
Elderly overweight women are more likely to develop KOA. Bone mass loss is an independent risk factor for KOA, which will significantly increase the prevalence of KOA in people overweight or aged 60 to 69 years old.
Humans
;
Female
;
Male
;
Aged
;
Osteoarthritis, Knee/etiology*
;
Middle Aged
;
Cross-Sectional Studies
;
Bone Density
;
Aged, 80 and over
;
Incidence
;
Body Mass Index
;
China/epidemiology*
;
Osteoporosis/epidemiology*
2.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
3.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
4.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
5.Clinical characteristics and prognosis of perioperative myocardial injury after non-cardiac surgery in intensive care unit patients
Shi-hong XIA ; Xue-li MA ; Guo-feng SHEN ; Li-jing JIANG ; Kang-yi LIU ; Wei-yi TANG ; Jin-di NI ; Xiang LI
Fudan University Journal of Medical Sciences 2025;52(3):424-428,445
Objective To retrospectively analyze the clinical risk factors and prognosis of perioperative myocardial injury(MINS)in non-cardiac surgery patients admitted to the intensive care unit(ICU).Methods A total of 478 postoperative patients admitted to the Department of Intensive Medicine,Minhang Hospital,Fudan University from Jan 2020 to Dec 2023 were selected.They were divided into MINS group(n=302)and normal group(n=176)based on whether myocardial injury occurred within 7 days after surgery.The differences in clinical characteristics between the two groups were compared,and risk factors for perioperative myocardial injury were identified.Risk factors for mortality in the MINS group were analyzed with 30-day mortality as the clinical endpoint.Results The prevalence of acute physiology and chronic health evaluation Ⅱ(Apache Ⅱ)score,coronary artery disease,and chronic kidney disease were all higher in the MINS group than those in the normal group,with statistically significant differences(P<0.05).The proportion of emergency surgeries,co-infection,and perioperative hypotension were significantly different between the MINS group and the normal group(P<0.05).Multivariate logistic regression analysis revealed that chronic kidney disease,emergency surgery,co-infection,and intraoperative and postoperative hypotension were risk factors for MINS occurrence.Prognostic analysis indicated that perioperative hypotension was a risk factor for 30-day mortality in MINS patients.Conclusion MINS is closely associated with patients'underlying conditions,timing of surgery,and perioperative hypotension status,and especially perioperative hypotension affects the final outcomes.
6.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
7.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
8.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
9.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
10.Clinical characteristics and prognosis of perioperative myocardial injury after non-cardiac surgery in intensive care unit patients
Shi-hong XIA ; Xue-li MA ; Guo-feng SHEN ; Li-jing JIANG ; Kang-yi LIU ; Wei-yi TANG ; Jin-di NI ; Xiang LI
Fudan University Journal of Medical Sciences 2025;52(3):424-428,445
Objective To retrospectively analyze the clinical risk factors and prognosis of perioperative myocardial injury(MINS)in non-cardiac surgery patients admitted to the intensive care unit(ICU).Methods A total of 478 postoperative patients admitted to the Department of Intensive Medicine,Minhang Hospital,Fudan University from Jan 2020 to Dec 2023 were selected.They were divided into MINS group(n=302)and normal group(n=176)based on whether myocardial injury occurred within 7 days after surgery.The differences in clinical characteristics between the two groups were compared,and risk factors for perioperative myocardial injury were identified.Risk factors for mortality in the MINS group were analyzed with 30-day mortality as the clinical endpoint.Results The prevalence of acute physiology and chronic health evaluation Ⅱ(Apache Ⅱ)score,coronary artery disease,and chronic kidney disease were all higher in the MINS group than those in the normal group,with statistically significant differences(P<0.05).The proportion of emergency surgeries,co-infection,and perioperative hypotension were significantly different between the MINS group and the normal group(P<0.05).Multivariate logistic regression analysis revealed that chronic kidney disease,emergency surgery,co-infection,and intraoperative and postoperative hypotension were risk factors for MINS occurrence.Prognostic analysis indicated that perioperative hypotension was a risk factor for 30-day mortality in MINS patients.Conclusion MINS is closely associated with patients'underlying conditions,timing of surgery,and perioperative hypotension status,and especially perioperative hypotension affects the final outcomes.

Result Analysis
Print
Save
E-mail