1.Guidelines for the perioperative diagnosis and treatment of oncogene-driven non-small cell lung cancer (2026)
Weidong WANG ; Yongbin LIN ; Hui TIAN ; Gaofeng LI ; Shun XU ; Yongde LIAO ; Haitao MA ; Junfeng LIU ; Chundong GU ; Xiaolong YAN ; Shumin WANG ; Daqiang SUN ; Jianyang LIU ; Tao XUE ; Shaohua MA ; Zhigang LI ; Shuanghu YUAN ; Gen LIN ; Ling CAI ; Jianping ZHOU ; Wenzhao ZHONG ; Naixin LIANG ; Yi HAN ; Junfeng WANG ; Weidong ZHANG ; Xin WANG ; Lianjuan CHEN ; Lunxu LIU ; Xiuyi ZHI ; Lanjun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(09):1337-1353
Lung cancer constitutes the most prevalent and lethal malignant tumor in China. Approximately 85% of lung cancer diagnoses correspond to the non-small cell histological subtype [non-small cell lung cancer (NSCLC)]. Despite surgery being the mainstay for early-stage disease, postoperative recurrence remains high and adjuvant chemotherapy offers limited benefit. In recent years, targeted therapy has demonstrated substantial advantages in driver mutation-positive NSCLC. To this end, the Lung Cancer Medical Education Committee of the Chinese Medical Education Association developed guidelines based on a systematic review of evidence through November 2025, using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach and a modified Delphi method. Focusing on epidermal growth factor receptor (EGFR) and anaplastic lymphoma kinase (ALK), and addressing ROS proto-oncogene 1 (ROS1), B-Raf proto-oncogene serine/threonine kinase (BRAF) V600E mutation, and mesenchymal-epithelial transition factor (MET) exon 14 (METex14) skipping, the guideline covers molecular testing, neoadjuvant/adjuvant therapy, perioperative strategies, minimal residual disease monitoring, and postoperative surveillance. It defines testing requirements, specifies stage-directed and subtype-specific treatments, and standardizes minimal residual disease monitoring. These recommendations emphasize precision and feasibility to improve survival and quality of life.
2.The Impairment Attention Capture by Topological Change in Children With Autism Spectrum Disorder
Hui-Lin XU ; Huan-Jun XI ; Tao DUAN ; Jing LI ; Dan-Dan LI ; Kai WANG ; Chun-Yan ZHU
Progress in Biochemistry and Biophysics 2025;52(1):223-232
ObjectiveAutism spectrum disorder (ASD) is a neurodevelopmental condition characterized by difficulties with communication and social interaction, restricted and repetitive behaviors. Previous studies have indicated that individuals with ASD exhibit early and lifelong attention deficits, which are closely related to the core symptoms of ASD. Basic visual attention processes may provide a critical foundation for their social communication and interaction abilities. Therefore, this study explores the behavior of children with ASD in capturing attention to changes in topological properties. MethodsOur study recruited twenty-seven ASD children diagnosed by professional clinicians according to DSM-5 and twenty-eight typically developing (TD) age-matched controls. In an attention capture task, we recorded the saccadic behaviors of children with ASD and TD in response to topological change (TC) and non-topological change (nTC) stimuli. Saccadic reaction time (SRT), visual search time (VS), and first fixation dwell time (FFDT) were used as indicators of attentional bias. Pearson correlation tests between the clinical assessment scales and attentional bias were conducted. ResultsThis study found that TD children had significantly faster SRT (P<0.05) and VS (P<0.05) for the TC stimuli compared to the nTC stimuli, while the children with ASD did not exhibit significant differences in either measure (P>0.05). Additionally, ASD children demonstrated significantly less attention towards the TC targets (measured by FFDT), in comparison to TD children (P<0.05). Furthermore, ASD children exhibited a significant negative linear correlation between their attentional bias (measured by VS) and their scores on the compulsive subscale (P<0.05). ConclusionThe results suggest that children with ASD have difficulty shifting their attention to objects with topological changes during change detection. This atypical attention may affect the child’s cognitive and behavioral development, thereby impacting their social communication and interaction. In sum, our findings indicate that difficulties in attentional capture by TC may be a key feature of ASD.
3.Progress in Methods for Electrochemical Detection of Thrombin
Di WU ; Xi-Yao ZHANG ; Jing-Jing XU ; Yi-Ting CHEN ; Wen-Qi TANG ; Wen-Hui XU ; Song-Min CHEN ; Qiong HU ; Li NIU
Chinese Journal of Analytical Chemistry 2025;53(9):1403-1410
As a serine protease,thrombin can convert soluble fibrinogen into insoluble fibrin and plays a pivotal role in the coagulation cascade.Therefore,the accurate quantitative assay of thrombin levels is of great value in the evaluation of coagulation function,clinical screening and prognostic monitoring of coagulation-related diseases,and screening of drugs for targeted therapy.Existing methods for thrombin detection can be divided into two categories,e.g.,the assay of concentration levels using nucleic acid aptamers as the affinity elements and the assay of activity levels based on the hydrolytic cleavage of substrate peptides.In recent years,electrochemical biosensors have attracted much attention in thrombin detection due to high sensitivity,high selectivity,simple instrument,fast response,and good portability.In this review,the latest research progress in methods for electrochemical detection of thrombin was summarized,focusing on the detection principles and the applied signal amplification strategies of related electrochemical biosensors.In addition,the challenges with respect to the practical use of electrochemical thrombin biosensors and the prospects were discussed.
4.Monte Carlo simulation study of the effect of filter on radiotherapy dosimetry in superficial X-ray therapy apparatus
Li TAO ; Hui ZHANG ; Yikai WU ; Junyi LIU ; Miao QI ; Ning GAO ; Yankui CHANG ; Xi PEI ; Zhi CHEN ; Xie XU
Chinese Journal of Radiological Medicine and Protection 2025;45(3):194-201
Objective:To explore the dosimetry optimization strategy based on filter thickness and shape selection for the bulb superficial X-ray radiotherapy unit.Methods:Monte Carlo code TOPAS was used to model tubular equipment, and the dose distribution from six X-ray energies (50-150 kV) and five conventional aluminum filters (0.5-3.0 mm) with different thickness were simulated in the water model. The percentage depth dose (PDD) curve along the central axis, the center-axis profile dose at different depths, and the lateral dose distribution were analyzed. The dose distribution of three different designs of aluminum filters (conventional cylindrical, conical and oblique cylindrical filters) was compared to evaluate the effect of dosimetric optimization of different filter shapes.Results:Under the same energy, increasing the thickness of the filter can optimize the superficial skin dose, and the optimization effect of depth dose uniformity can be increased by 26% at a depth of 5.5 mm at 70 kV energy. The raised, flat and inclined dose distribution modes can be achieved by using conventional cylindrical, conical and inclined aluminum filters.Conclusions:By selecting the appropriate X-ray energy and filter thickness, an ideal dose distribution matching the tumor depth can be achieved. The application of personalized filters is also of great significance for diverse target areas.
5.Psychological stress-activated NR3C1/NUPR1 axis promotes ovarian tumor metastasis.
Bin LIU ; Wen-Zhe DENG ; Wen-Hua HU ; Rong-Xi LU ; Qing-Yu ZHANG ; Chen-Feng GAO ; Xiao-Jie HUANG ; Wei-Guo LIAO ; Jin GAO ; Yang LIU ; Hiroshi KURIHARA ; Yi-Fang LI ; Xu-Hui ZHANG ; Yan-Ping WU ; Lei LIANG ; Rong-Rong HE
Acta Pharmaceutica Sinica B 2025;15(6):3149-3162
Ovarian tumor (OT) is the most lethal form of gynecologic malignancy, with minimal improvements in patient outcomes over the past several decades. Metastasis is the leading cause of ovarian cancer-related deaths, yet the underlying mechanisms remain poorly understood. Psychological stress is known to activate the glucocorticoid receptor (NR3C1), a factor associated with poor prognosis in OT patients. However, the precise mechanisms linking NR3C1 signaling and metastasis have yet to be fully elucidated. In this study, we demonstrate that chronic restraint stress accelerates epithelial-mesenchymal transition (EMT) and metastasis in OT through an NR3C1-dependent mechanism involving nuclear protein 1 (NUPR1). Mechanistically, NR3C1 directly regulates the transcription of NUPR1, which in turn increases the expression of snail family transcriptional repressor 2 (SNAI2), a key driver of EMT. Clinically, elevated NR3C1 positively correlates with NUPR1 expression in OT patients, and both are positively associated with poorer prognosis. Overall, our study identified the NR3C1/NUPR1 axis as a critical regulatory pathway in psychological stress-induced OT metastasis, suggesting a potential therapeutic target for intervention in OT metastasis.
6.Effects of luteolin on glucose and lipid metabolism and liver oxidative stress injury in db/db mice based on artificial intelligence assisted drug quality evaluation and pharmacodynamics and its mechanisms
Qi XU ; Hong-rong ZHANG ; Nuo-bing RUAN ; Xi-juan LYU ; Zhao-hui FANG
Chinese Pharmacological Bulletin 2025;41(2):323-333
Aim To study the possibility of luteolin(LUT)as a new drug of traditional Chinese medicine and its improving effect on glucose and lipid metabo-lism and liver oxidative stress injury in db/db mice,and to explore the possible mechanism.Methods AI was used to predict the drug toxicity,evaluate the phys-ical and chemical properties and segment the molecular structure of LUT.Molecular docking was used to verify the binding ability of LUT with Nrf2 and HMOX1;db/m mice were divided into the group C,and db/db mice were randomly divided into the T,L,M,H and P groups.The body weight and FBG changes were ob-served within 12 weeks of intervention.The expres-sions of FBG,HbA1c,Fins,TC,TG,HDL-C,LDL-C were detected.The pathomorphological changes and steatosis of mouse liver were observed by HE and oil red O staining.The expression of MDA,SOD and GSH-Px in liver was detected by Kit.The protein and mRNA expressions of Nrf2 and HMOX1 were detected by immunohistochemistry,WB and qPCR.Results AI algorithm predicted the safety and easy synthesis of LUT.LUT intervention had no significant effect on the body weight of db/db mice.After 12 weeks,compared with the group C,the livers of mice in group T showed disordered structure of hepatic lobules,irregular ar-rangement of hepatocytes,and a large number of fat vacuoles and lipid droplets in the cytoplasm.Compared with the group T,LUT intervention could improve the pathological changes of liver,reduce the expression of FBG,HbA1c,fins,TC,TG,LDL-C,MDA,improve the level of HOMA-IR,and upregulate the activities of SOD and GSH-Px.Molecular docking results showed LUT had strong binding with Nrf2 and HMOX1,and could increase the expression of Nrf2 and HMOX1.Conclu-sion LUT can correct the disorder of glucose and lip-id metabolism in db/db mice,and improve the level of oxidative stress in liver of mice through Nrf2/HMOX1 pathway,which has the development prospect as a new Chinese medicine for the treatment of T2DM.
7.Monte Carlo simulation study of the effect of filter on radiotherapy dosimetry in superficial X-ray therapy apparatus
Li TAO ; Hui ZHANG ; Yikai WU ; Junyi LIU ; Miao QI ; Ning GAO ; Yankui CHANG ; Xi PEI ; Zhi CHEN ; Xie XU
Chinese Journal of Radiological Medicine and Protection 2025;45(3):194-201
Objective:To explore the dosimetry optimization strategy based on filter thickness and shape selection for the bulb superficial X-ray radiotherapy unit.Methods:Monte Carlo code TOPAS was used to model tubular equipment, and the dose distribution from six X-ray energies (50-150 kV) and five conventional aluminum filters (0.5-3.0 mm) with different thickness were simulated in the water model. The percentage depth dose (PDD) curve along the central axis, the center-axis profile dose at different depths, and the lateral dose distribution were analyzed. The dose distribution of three different designs of aluminum filters (conventional cylindrical, conical and oblique cylindrical filters) was compared to evaluate the effect of dosimetric optimization of different filter shapes.Results:Under the same energy, increasing the thickness of the filter can optimize the superficial skin dose, and the optimization effect of depth dose uniformity can be increased by 26% at a depth of 5.5 mm at 70 kV energy. The raised, flat and inclined dose distribution modes can be achieved by using conventional cylindrical, conical and inclined aluminum filters.Conclusions:By selecting the appropriate X-ray energy and filter thickness, an ideal dose distribution matching the tumor depth can be achieved. The application of personalized filters is also of great significance for diverse target areas.
8.Monte Carlo study of transmission X-ray tubes in kilovoltage radiotherapy
Yikai WU ; Zhongyu QI ; Li TAO ; Hui ZHANG ; Zeeshan MUHAMMAD ; Zirui YE ; Yankui CHANG ; Xi PEI ; Xu GEORGE
Chinese Journal of Medical Physics 2025;42(7):863-871
Transmission X-ray tubes are relatively new devices characterized by portability,suitability for miniaturization,and low requirements for shielding,making them ideal radiation sources for kilovoltage X-ray therapy.However,their application in radiotherapy remains underexplored.An electron target model of a transmission X-ray tube is developed using the Monte Carlo toolkit TOPAS 3.8.1.The study investigates the effect of tungsten target thickness on X-ray output efficiency,finding that a tube voltage of 50 kV and a tungsten thickness of 1.4 μm yields the highest emission efficiency.Based on the energy spectrum at this optimal efficiency,polynomial fitting approach is applied to determine the corresponding aluminum filter thickness for mean energies ranging from 20 keV to 35 keV,achieving a mean fitting error of 0.91%.Next,the study simulates dose deposition in a water phantom for spectra with different mean energies and various source-to-surface distances,and plots percent-depth-dose curves,relative normalized dose-depth curves,and relative normalized dose histograms under each treatment condition.Finally,the simulated results are compared with experimental data from the intraoperative radiotherapy system Intrabeam and the superficial X-ray therapy unit SRT-100,obtaining average relative errors of 3.71%and 4.38%,respectively.These findings provide a theoretical foundation for further optimization of transmission X-ray tubes in kilovoltage radiotherapy.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail