1.The SMAD-Pathway Mediates HMGB1-Induced Proliferation and Metastatic Progression in Cutaneous Squamous Cell Carcinoma Cells
De-De LIAN ; Xue Mei LI ; Yu-Xi JIA ; Ming-Wei ZHOU ; Xiang-Ru CHEN ; Yang-Yang TIAN ; Min LI ; Ming-Hui SUN ; Ye ZHAO ; Hong-Jun LI ; Qing-Ling ZHANG
Annals of Dermatology 2026;38(1):51-58
Background:
High-mobility group box protein 1 (HMGB1) is a chromatin-binding protein involved in arthritis, ischemia, sepsis, atherosclerosis, neurodegenerative disorders, meningitis, and cancer. HMGB1 exhibits dual roles in cancer, acting as either a tumor suppressor or oncoprotein depending on context.
Objective:
This research aimed to elucidate HMGB1’s functional significance in cutaneous squamous cell carcinoma (cSCC).
Methods:
We overexpressed HMGB1 in cSCC cell lines using recombinant adenovirus and examined its effects on cell proliferation, colony formation, and cell migration.
Results:
Immunohistochemical analysis revealed elevated HMGB1 expression levels in cSCC tissue relative to normal epidermis. To assess the influence of HMGB1, we employed recombinant adenoviruses expressing HMGB1 to transduce SCC cell lines (SCC12 and SCC13). Enhanced HMGB1 expression significantly promoted cellular proliferation and colony formation capacity.Notably, HMGB1 overexpression elevated the levels of proliferation regulators, including P63, SOX2, CDK4 and CDK6. Furthermore, HMGB1 overexpression substantially enhanced tumor invasiveness, accompanied by upregulation of epithelial-mesenchymal transition (EMT) biomarkers. Mechanistically, overexpression of HMGB1 enhanced transforming growth factor-β signaling by increasing phosphorylation of SMAD2/3, the key mediators of EMT.
Conclusion
These data imply that HMGB1 acts as a tumor-promoting factor in cSCC.
2.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
3.Environmental contamination status of norovirus outbreaks in schools and nurseries in Linhai City
ZHENG Jianjun, WANG Xi,HONG Danyang, LI Yaling, XU Qiumeng, ZHANG Huili, HAN Qian, LU Da, ZHENG Qiao
Chinese Journal of School Health 2025;46(4):601-603
Objective:
To investigate the environmental contamination of norovirus in nurseries and primary/secondary schools, so as to provide a scientific basis for effective prevention and control measures.
Methods:
A total of 483 external environmental samples were collected from 34 cluster outbreaks of norovirus gastroenteritis in kindergartens and primary/secondary schools in Linhai City from 2021 to 2024. Pathogen detection was conducted using a rapid nucleic acid extraction kit and realtime fluorescence RT-PCR, and the results were analyzed using the χ2 test or Fishers exact test.
Results:
Among the collected external environmental samples, the total positive rate of surface contamination was 13.66%. The positive rates in kindergartens and primary/secondary schools were 12.20% and 15.82%, respectively. In kindergartens, the five surfaces with the highest detection rates were desks/chairs (23.33%), toilet stool troughs (20.69%), urinal troughs (12.00%), washbasins/sinks (11.11%), and toilet mops (9.38%). In primary/secondary schools, the top five were toilet stool troughs (38.30%), urinal troughs (23.53%), toilet door handles (13.04%), toilet mops (12.50%), and drinking cups (11.11%). The difference in positive detection rates among different external environments in primary/secondary schools was statistically significant (Fishers exact probability test, P<0.01). The positive detection rate in sanitary toilets was higher than that in classroom environments (χ2=17.38), while the positive detection rate in classroom environments of kindergartens was higher than that in primary/secondary schools (χ2=5.42)(P<0.05).
Conclusions
Norovirus exhibits a high contamination rate in nurseries and schools, particularly in restroom areas. Strengthening sanitation and disinfection in highrisk environments, and improving hygiene awareness among children and staff, are essential for the effective prevent and control of norovirus.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Effect and mechanism of circular RNA SEC24A on proliferation and apoptosis of synovial fibroblasts in osteoarthritis
Lijun ZHOU ; Keyuan ZHANG ; Feihu XU ; Xi WANG ; Li YU ; Shiming DONG ; Junyu XU ; Yufeng GUO ; Hairong MA ; Hong DING
Chinese Journal of Tissue Engineering Research 2025;29(24):5086-5092
BACKGROUND:Synovitis is involved in all stages of osteoarthritis and is a key factor contributing to the development of osteoarthritis.Studies have shown that circular RNA(circRNA)plays an important role in the proliferation,apoptosis and extracellular matrix degradation of synovial cells and chondrocytes.OBJECTIVE:To observe the effects of circRNA SEC24A on the interleukin-1β-induced proliferation,apoptosis,and expression of inflammatory factors in human synovial fibroblasts.METHODS:Human synovial fibroblasts were divided into four groups,including control group,interleukin-1β group,empty vector group,and sh-circSEC24A group.Except for the control group,the other three groups were induced with 10 ng/mL interleukin-1β for 24 hours to establish inflammatory cell models;the empty vector group and sh-circSEC24A group were infected with empty vector virus and lentiviral vector knocking down circSEC24A.CCK-8 assay was used to detect cell proliferation.Flow cytometry was used to detect cell apoptosis.ELISA was used to detect the levels of matrix metalloproteinase-9,matrix metalloproteinase-13,interleukin-6,and tumor necrosis factor-α in cell supernatant.Western blot assay was used to detect the relative expression levels of Bax,Bcl-2,matrix metalloproteinase-9,matrix metalloproteinase-13,casepase3,cleaved-casepase3,casepase8,and cleaved-casepase8 proteins in cells.RESULTS AND CONCLUSION:(1)qRT-PCR results showed that compared with the normal group,the expression of circSEC24A in human synovial fibroblasts induced by interleukin 1β was significantly up-regulated.(2)The absorbance value of cells in the sh-circSEC24A group detected by CCK-8 assay was significantly higher than that of interleukin 1β group and empty vector group(P<0.05).The apoptosis rate of sh-circSEC24A group detected by flow cytometry was significantly lower than that of interleukin 1β group and empty vector group(P<0.05).(3)The levels of tumor necrosis factor α and interleukin 6 in the supernatant of human synovial fibroblasts in the sh-circSEC24A group detected by ELISA were significantly lower than those in the interleukin 1β group and the empty vector group(P<0.01,P<0.001).(4)Western blot assay results showed that compared with the interleukin 1β group and the empty vector group,the expression of the pro-apoptotic factor Bax protein in the sh-circSEC24A group significantly decreased,and the expression of the anti-apoptotic factor Bcl-2 protein increased significantly(P<0.05);apoptosis and related activating factors cleaved-casepase3 and cleaved-casepase8 protein expressions were both reduced(P<0.05).(5)ELISA and western blot assay results showed that compared with the interleukin 1β group and the empty vector group,the sh-circSEC24A group had lower levels of matrix metalloproteinase 9 and matrix metalloproteinase 13 protein(P<0.05).These findings indicated that the expression of circSEC24A was abnormally increased in human synovial fibroblasts induced by interleukin 1β.Knocking down circSEC24A expression could promote the proliferation of human synovial fibroblasts and inhibit apoptosis,inflammatory factor release,and extracellular matrix degradation,suggesting that circSEC24A may be an important intervention target for early osteoarthritis.
8.Research on the cognition,preference and willingness to pay of Traditional Chinese Medicine intelligent diagnosis device of Beijing residents based on Discrete Choice Experiment
Rui-xi QIN ; Rui-feng LI ; Hong-yun WANG ; Han XUE ; Liang-ru ZHOU
Chinese Journal of Health Policy 2025;18(8):46-52
Objective:This paper investigates residents'awareness and preference for Traditional Chinese Medicine intelligent diagnostic device(hereinafter referred to as the device),and provides basis and suggestions for further promoting the integrated development of artificial intelligence and traditional Chinese medicine clinical diagnosis.Method:A random sampling survey was conducted,and a Discrete Choice Experiment was designed to conduct an offline survey in Beijing.Use chi square test,count analysis,and conditional Logit model for data analysis.Result:A total of 480 valid questionnaires were collected and surveyed.Most respondents have heard of it(58.96%),a few have used it(31.67%),and most would recommend the device(71.25%).Knowing and using experience will increase the probability of recommendation.Residents attach the highest importance to annual average expenses;More inclined to use devices in the community that can see family data,connect data and hospitals,monitor electrocardiogram,provide comprehensive health reports,and have low annual costs;Willing to pay an additional 572 yuan per year for the comprehensive health report device.Conclusion:There should be more collaboration with hospitals in usage scenarios and cloud data.In addition,manufacturers should enrich output information and service methods of the e.
9.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
10.Study of debridement effects of multi shapes of plasma scalpels in explosion injury model
Hong-ye ZHENG ; Yu LI ; Zi-heng XU ; Yu-fan WEI ; Bo-ya ZHANG ; Yan LI ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(2):31-38
Objective To explore the debridement effects of 3 types of plasma scalpels for the animal model of explosion injury,and to compare them with the steel scalpel and high-frequency electrosurgical scalpel.Methods Firstly,blast wounds were constructed in the right inguinal regions of 9 Landrace pigs by high-pressure gas impact combined with preset metal shrapnel.Secondly,debridement was carried out in experimental groups with wide-,arrow-or needle-type plasma scalpel and in control groups with steel and high-frequency electrisurgical scalpel,with the operating temperature and debridement time recorded during the procedure and trauma specimens analyzed pathologically after the debridement;comparisons were performed among the five types of scalpels in terms of debridement effect,and among the four ones in terms of maximum operating temperature and depth of tissue thermal damage under electrocutaneous cutting and electrocoagulation modes with the steel scalpel excluded because it did not generate any heat.GraphPad Prism 9.5.1 software was used for statistical analysis.Results There were no significant differences in debridement effect found between the three plasma scalpels and the steel and high-frequency electrosurgical scalpels(P>0.05).The three types of plasma scalpels had the maximum operating temperature lower significantly than that of the high-frequency electrosurgical scalpel during debridement(P<0.05).Under electrosection and electrocoagulation modes the three plasma scalpels had the depths of tissue thermal damage statistically less than that by the high-frequency electrosurgical scalpel under electrosection and electrocoagulation modes(P<0.05).The depths of tissue thermal damage by the four scalpels under electrocoagulation mode were obviously greater than those under electrosection mode(P<0.05).Conclusion Multi shapes of plasma scalpels behave well in debridement with low operating temperature,little tissue thermal damage and high efficiency for wound protection and the same efficacy with the steel scalpel and high-frequency electrosur-gical scalpel.[Chinese Medical Equipment Journal,2025,46(2):31-38]


Result Analysis
Print
Save
E-mail