1.A bibliometric and visual analysis of the literature published in the journal of Organ Transplantation since its inception
Xi CAO ; Tao HUANG ; Qiwei YANG ; Lin YU ; Xiaowen WANG ; Wenfeng ZHU ; Haoqi CHEN ; Ning FAN ; Genshu WANG
Organ Transplantation 2026;17(1):133-142
Objective To systematically analyze the literature characteristics of Journal of Organ Transplantation since its inception. Methods Using the China National Knowledge Infrastructure (CNKI) academic journal full-text database as the data source, all articles published in the Journal of Organ Transplantation from January 2010 to August 2025 were retrieved. After excluding non-academic papers, a total of 1 568 research papers were included. R language 4.3.0, Bibliometrix package 3.2.1, and Citespace software were used to analyze the number of publications, publishing institutions, authors, keywords and other aspects. Results The number of publications in Journal of Organ Transplantation increased from an average of 82 articles per year in the early years after its inception to 113 articles per year in recent years, a growth of 37.8%. The geographical distribution of publishing institutions covers 32 provinces, cities and autonomous regions nationwide, mainly concentrated in the South China, East China and North China regions, and has now basically covered the central and western regions in recent years. The author collaboration network includes 45 authors distributed across 7 major collaboration clusters, forming a stable multi-level national research system centered on key university-affiliated hospitals. The high-frequency keywords are dominated by "liver transplantation" (425 times) and "kidney transplantation" (396 times). The theme evolution shows a clear three-stage characteristic: initially focusing on clinical technology application, deepening to immune mechanism exploration in the middle stage, and recently (since 2022) focusing on cutting-edge research areas such as xenotransplantation. Conclusions Journal of Organ Transplantation has witnessed the rapid development of China's organ transplantation cause, fully reflecting the research status and trends in China's organ transplantation field, and has provided an important platform for the future development and international cooperation in China's organ transplantation field.
2.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
3.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
4.Low-titer group O whole blood: challenges to blood stations
Hong LIN ; Xi YU ; Wenjia HU ; Ling MA
Chinese Journal of Blood Transfusion 2025;38(2):297-302
Whole blood transfusion for the resuscitation of trauma patients is not a new concept, with its history dating back to World War I. Due to the significant survival benefits of early intervention with whole blood, an increasing number of countries and regions are using whole blood for pre-hospital resuscitation of patients with traumatic haemorrhage. Whole blood containing low-titer anti-A and anti-B antibodies is known as low-titer group O whole blood. The safety of transfusion of low-titer group O whole blood has been proven in military and local trauma centers in some countries. The use of low-titer group O whole blood for pre-hospital trauma care in China will pose new challenges to blood stations that provide whole blood. This paper reviews the selection of group O donors, the setting of anti-A and anti-B titers threshold and their detection, as well as the collection, preparation and storage of whole blood.
5.Severity Assessment Parameters and Diagnostic Technologies of Obstructive Sleep Apnea
Zhuo-Zhi FU ; Ya-Cen WU ; Mei-Xi LI ; Ping-Ping YIN ; Hai-Jun LIN ; Fu ZHANG ; Yu-Xiang YANG
Progress in Biochemistry and Biophysics 2025;52(1):147-161
Obstructive sleep apnea (OSA) is an increasingly widespread sleep-breathing disordered disease, and is an independent risk factor for many high-risk chronic diseases such as hypertension, coronary heart disease, stroke, arrhythmias and diabetes, which is potentially fatal. The key to the prevention and treatment of OSA is early diagnosis and treatment, so the assessment and diagnostic technologies of OSA have become a research hotspot. This paper reviews the research progresses of severity assessment parameters and diagnostic technologies of OSA, and discusses their future development trends. In terms of severity assessment parameters of OSA, apnea hypopnea index (AHI), as the gold standard, together with the percentage of duration of apnea hypopnea (AH%), lowest oxygen saturation (LSpO2), heart rate variability (HRV), oxygen desaturation index (ODI) and the emerging biomarkers, constitute a multi-dimensional evaluation system. Specifically, the AHI, which measures the frequency of sleep respiratory events per hour, does not fully reflect the patients’ overall sleep quality or the extent of their daytime functional impairments. To address this limitation, the AH%, which measures the proportion of the entire sleep cycle affected by apneas and hypopneas, deepens our understanding of the impact on sleep quality. The LSpO2 plays a critical role in highlighting the potential severe hypoxic episodes during sleep, while the HRV offers a different perspective by analyzing the fluctuations in heart rate thereby revealing the activity of the autonomic nervous system. The ODI provides a direct and objective measure of patients’ nocturnal oxygenation stability by calculating the number of desaturation events per hour, and the biomarkers offers novel insights into the diagnosis and management of OSA, and fosters the development of more precise and tailored OSA therapeutic strategies. In terms of diagnostic techniques of OSA, the standardized questionnaire and Epworth sleepiness scale (ESS) is a simple and effective method for preliminary screening of OSA, and the polysomnography (PSG) which is based on recording multiple physiological signals stands for gold standard, but it has limitations of complex operations, high costs and inconvenience. As a convenient alternative, the home sleep apnea testing (HSAT) allows patients to monitor their sleep with simplified equipment in the comfort of their own homes, and the cardiopulmonary coupling (CPC) offers a minimal version that simply analyzes the electrocardiogram (ECG) signals. As an emerging diagnostic technology of OSA, machine learning (ML) and artificial intelligence (AI) adeptly pinpoint respiratory incidents and expose delicate physiological changes, thus casting new light on the diagnostic approach to OSA. In addition, imaging examination utilizes detailed visual representations of the airway’s structure and assists in recognizing structural abnormalities that may result in obstructed airways, while sound monitoring technology records and analyzes snoring and breathing sounds to detect the condition subtly, and thus further expands our medical diagnostic toolkit. As for the future development directions, it can be predicted that interdisciplinary integrated researches, the construction of personalized diagnosis and treatment models, and the popularization of high-tech in clinical applications will become the development trends in the field of OSA evaluation and diagnosis.
6.Effect of The Hydrophilic Amino Acids on Self-assembly Behavior of Short Bola-like Peptides
Xin-Xin GAO ; Yu HAN ; Yi-Lin ZHOU ; Xi-Ya CHEN ; Yu-Rong ZHAO
Progress in Biochemistry and Biophysics 2025;52(5):1290-1301
ObjectiveBola-like short peptides exhibit novel self-assembly properties due to the formation of peptide dimers via hydrogen bonding interactions between their C-terminals. In this configuration, hydrophilic amino acids are distributed at both terminals, making these peptides behave similarly to Bola peptides. The electrostatic repulsive interactions arising from the hydrophilic amino acids at each terminal can be neutralized, thereby greatly promoting the lateral association of β-sheets. Consequently, assemblies with significantly larger widths are typically the dominant nanostructures for Bola-like peptides. To investigate the effect of hydrophilic amino acids on the self-assembly behavior of Bola-like peptides, the peptides Ac-RI3-CONH2 and Ac-HI3-CONH2 were designed and synthesized using the Bola-like peptide Ac-KI3-CONH2 as a template. Their self-assembly behavior was systematically examined. MethodsAtomic force microscopy (AFM) and transmission electron microscopy (TEM) were employed to characterize the morphology and size of the assemblies. The secondary structures of the assemblies were analyzed using circular dichroism (CD) and Fourier transform infrared (FTIR) spectroscopy. Small-angle neutron scattering (SANS) was used to obtain detailed structural information at a short-length scale. Based on these experimental results, the effects of hydrophilic amino acids on the self-assembly behavior of Bola-like short peptides were systematically analyzed, and the underlying formation mechanism was explored. ResultsThe aggregation process primarily involved three steps. First, peptide dimers were formed through hydrogen bonding interactions between their C-terminals. Within these dimers, the hydrophilic amino acids K, R, and H were positioned at both terminals, enabling the peptides to self-assemble in a manner similar to Bola peptides. Next, β-sheets were formed via hydrogen bonding interactions along the peptide backbone. Finally, self-assemblies were generated through the lateral association of β-sheets. The results demonstrated that both Ac-KI3-CONH2 and Ac-RI3-CONH2 could self-assemble into double-layer nanotubes with diameters of approximately 200 nm. These nanotubes were formed by the edge fusion of helical ribbons, which initially emerged from twisted ribbons. Notably, the primary assemblies of these peptides exhibited opposite chirality: nanofibers formed by Ac-KI3-CONH2 displayed left-handed chirality, whereas those formed by Ac-RI3-CONH2 exhibited right-handed chirality. This reversal in torsional direction was primarily attributed to the different abilities of K and R to form hydrogen bonds with water. In contrast, Ac-HI3-CONH2 formed narrower twisted ribbons with a significantly reduced width of approximately 30 nm, which was attributed to the strong steric hindrance caused by the imidazole rings. The multilayer height of these ribbons was mainly due to the unique structure of the imidazole rings, which can function as both hydrogen bond donors and acceptors, thereby promoting aggregate growth in the vertical direction. ConclusionThe final morphology of the self-assemblies resulted from a delicate balance of various non-covalent interactions. By altering the types of hydrophilic amino acid residues in Bola-like short peptides, the relative strength of non-covalent interactions that drive assembly formation can be effectively regulated, allowing precise control over the morphology and chirality of the assemblies. This study provides a simple and effective approach for constructing diverse self-assemblies and lays a theoretical foundation for the development of functional biomaterials.
7.Development and evaluation of the clinical standard operating procedure for dust mite nasal allergen challenge
Yu ZHANG ; Yu SONG ; Xu ZHANG ; Jingyun LI ; Lin XI ; Yuan ZHANG ; Luo ZHANG
Chinese Archives of Otolaryngology-Head and Neck Surgery 2025;32(8):480-485
OBJECTIVE To establish standardized operating procedures,result interpretation guidelines,and clinical application protocols for dust mite-nasal allergen challenge(NAC),and to systematically evaluate its operational reliability and safety.METHODS Patients with positive serum-specific IgE(sIgE)against mites and healthy controls were enrolled between January 2023 and December 2024.Demographic and clinical information was systematically collected.A standardized mite allergen extract was utilized to prepare the challenge solution for all participants.Bilateral synchronous nasal spray challenges were conducted using progressively increasing concentrations(1 000,3 000,10 000,and 30 000 BU/ml).During the challenge,total nasal symptom scores,visual analogue scale,acoustic rhinometry,active anterior rhinomanometry,and four-phase rhinomanometry were assessed,and all evaluation data and diagnostic outcomes were documented accordingly.RESULTS Compared to the baseline measurements,both subjective symptom scores and objective evaluation indicators in patients demonstrated statistically significant changes following NAC(P≤0.001).Among these patients,40 individuals(81.6%)exhibited a positive response to the dust mite-NAC.All healthy control subjects showed negative results in the test.CONCLUSION This study established standardized operating procedures and clinical application guidelines for the dust mite-NAC.These encompass indications,contraindications,preparation of stimulation solutions,procedural steps,operational standards,criteria for positive results,and pre-/post-examination precautions,thereby providing a clinically actionable framework for dust mite-NAC implementation.
8.Fast Screening of 10 Kinds of Illegal Aphrodisiac Drugs in Foods by Matrix-assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry
Xi ZENG ; Yu WANG ; Ying-Li CHEN ; Tian-Tian ZHAO ; Zhen-Lin XU ; Heng-Xin ZHOU
Chinese Journal of Analytical Chemistry 2025;53(3):441-450,中插3-中插5
A matrix-assisted laser desorption ionization time-of-flight mass spectrometry(MALDI-TOF MS)method was developed for simultaneous analysis of 10 kinds of aphrodisiac drugs,including sildenafil,acetildenafil,nor-acetildenafil,homosildenafil,lodenafil carbonate,sildlenafil dimer impurity,vardenafil dimer,hydroxyacetildenafil,N-desmethylsildenafil and udenafil.By using different matrices(α-cyano-4-hydroxycinnamic acid(HCCA)and sinapic acid(SA)),the effects of solvents,amount of matrices,laser intensity and spotting methods on the peak strength and signal intensity of MALDI-TOF MS for the aphrodisiac drugs were investigated.As a result,SA was chosen as the matrix,and then dispersed in methanol-water(50∶50,V/V),and spotted by matrix firstly and sample secondly approach with the reflect linear positive mode and laser power of 60%.Under optimal conditions,the proposed MALDI-TOF MS method could obtain stable signal,high intensity and well-repeated mass spectrometric results.The results of method validation showed a linear range from 10 to 100 ng/mL,and the regression coefficients(r)were all above 0.985.The limits of detection(LOD)were 0.1-1.0 ng/mL,and the recoveries were in the range of 72.9%-109.9%for health wine,soft capsule and instant coffee samples,while the relative standard deviations(RSDs)ranged from 0.7%to 11.3%(n=3).The test results of 10 kinds of aphrodisiac drugs by MALDI-TOF MS were in accordance with the results of high-performance liquid chromatography-tandem mass spectrometry.This method exhibited high sensitivity,high accuracy,good anti-interference ability,low chemical solvents consumption and environmentally friendliness,and could be used to detect drugs without standards.The developed MALDI-TOF MS method could realize the non-target screening and detection of 10 kinds of illegally added aphrodisiac drugs in foods.
9.Synthesis of A New Naphthalenesulfonamide-based"Turn-on"Fluorescent Probe for Rapid Detection of Glyphosate
Rong-Rong ZHAO ; Hong-Lin LIU ; Ying-Ping HUANG ; Cui-Wen DENG ; Song-Yan LI ; Shui-Lian YU ; Mao-Sheng TAO ; Yi-Qun TIAN ; Xi YUAN
Chinese Journal of Analytical Chemistry 2025;53(6):903-913
Widespread utilization of glyphosate has led to environmental residues,posing potential threats to ecological systems and human health.Traditional methods for detection of glyphosate are limited by specialized equipment and operational techniques,resulting in inefficient responses.Therefore,it is urgent to develop a convenient,sensitive and accurate detection method for detection of glyphosate.Herein,a new naphthalenesulfonamide-based"Turn-on"fluorescent probe was synthesized using 2-chloroaniline and dansyl chloride as raw materials through a one-step process,which showed a good linear relationship between the glyphosate concentration in concentration range of 0.003-70 μmol/L and the fluorescence intensity(R2=0.995),with a detection limit of 2.73 nmol/L(S/N=3).Analytical techniques such as nuclear magnetic resonance(NMR)spectroscopy and high-resolution mass spectrometry(HRMS)were used to investigate the interaction mechanism between the fluorescent probe and glyphosate.The results indicated that a nucleophilic substitution reaction occurred between the probe and the secondary amine(—NH—)of glyphosate,inducing a photoinduced electron transfer(PET)effect which enhanced the fluorescence intensity by 11.2 times.The probe showed good anti-interference ability towards coexisting metal ions,anions and pesticides in water.When applied to determination of glyphosate in the samples such as tap water,river water(Xiangxi River Reservoir),soil,soybeans,and corn,the spiking recoveries ranged from 94.7%to 109.9%,demonstrating the high accuracy and broad applicability of this detection method.A portable test strip based on this fluorescent probe was developed for rapid semi-quantitative analysis of glyphosate.The developed method was rapid,sensitive,and portable,providing theoretical and technical support for on-site measurement of environmental contaminants.
10.Synthesis and Applications of Indole-3-formylhydrazine Modified Pyrene Schiff Base Compound as Copper Ion Fluorescence Probe
Mu-Xi WANG ; Zhen-Yu HUANG ; Xiao-Feng LIN ; Xiao-Lan LEI ; Jian SUN ; Li-Jun MA
Chinese Journal of Analytical Chemistry 2025;53(7):1108-1117
In this work,a fluorescent probe PIN was synthesized using indole-3-carbohydrazide and pyrenecarboxaldehyde as raw materials.PIN showed weak fluorescence emission in aqueous solution with acetonitrile volume fraction of 70%.However,when Cu2+was added to this aqueous solution of PIN,a new fluorescence emission peak appeared at 495 nm,and the intensity of this peak gradually increased with the increase of concentration of Cu2+,and also caused a significant change in the fluorescence color of the solution.In contrast,the addition of 15 kinds of other common metal ions did not cause such change.The detection limit of PIN for Cu2+was 78.7 nmol/L,which was much lower than the maximum permitting level of Cu2+in drinking water in hygienic standard for drinking water in China.Therefore,PIN was a highly selective and sensitive fluorescence-enhanced probe for Cu2+.Meanwhile,the addition of Cu2+could also cause a new absorption peak at 440 nm in the ultraviolet-visible absorption spectrum of the aqueous solution of PIN,and meanwhile the colorless PIN solution changed into yellow,exhibiting the performance of PIN as a colorimetric probe for Cu2+.By fitting with the Levenberg-Marquardt algorithm equation,the binding ratio of PIN to Cu2+was 2:1,and the binding constant was 3.42×1012 L2/mol2.In addition,the binding mode of PIN with Cu2+was explored by using proton nuclear magnetic resonance(1H NMR)titration experiments and density functional theory simulations.The results showed that the addition of Cu2+could cause the aggregation of PIN molecules to form excimers,thus showing highly selective recognition.Finally,PIN was made into a simple test strip,which could achieve rapid and convenient fluorescence detection of Cu2+in actual water samples.


Result Analysis
Print
Save
E-mail