1.The Association of Iodixanol With Renal and Cardiovascular Safety in Patients With ST-Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention:A Prospective Cohort Study
Zhaoping LIU ; Jian AN ; Aijie HOU ; Yanqin REN ; Lei QIN ; Xiaojie CHEN ; Guozhen HAO ; Xi SU ; Ping YANG ; Guidong SHEN ; Shenghuang WANG ; In-ho CHAE ; Yong HUO
Journal of Cardiovascular Intervention 2026;5(1):38-48
Background:
This study was performed to characterize the incidence, costs, and risk factors associated with renal and cardiovascular adverse outcomes following primary percutaneous coronary intervention (pPCI) in patients with ST-elevation myocardial infarction (STEMI).
Methods:
Patients with STEMI who underwent pPCI using iso-osmolar contrast were enrolled at 39 centers. The incidence of acute kidney injury (AKI) and major adverse renal and cardiovascular events (MARCE) was analyzed, as well as inpatient costs. Logistic regression analysis was performed to identify risk factors.
Results:
Among 2,293 patients, the incidence of AKI and MARCE within 72 hours post-pPCI was 4.14% (n = 95) and 4.40% (n = 101), respectively. AKI and/or MARCE were associated with systolic blood pressure (AKI: odds ratio [OR], 1.009; 95% confidence interval [CI], 1.000–1.018), hypertension (AKI: OR, 1.815; 95% CI, 1.133–2.906; MARCE: OR, 1.760;95% CI, 1.118–2.769), anterior wall infarction (AKI: OR, 1.895; 95% CI, 1.196–3.004; MARCE:OR, 1.939; 95% CI, 1.240–3.032), Killip class (AKI: OR, 1.465; 95% CI, 1.117–1.922; MARCE:OR, 1.467; 95% CI, 1.131–1.903), and serum creatinine (SCr; MARCE: OR, 1.006; 95% CI, 1.000–1.012). Hospitalization costs for patients with STEMI who developed AKI or MARCE were significantly higher than for those without AKI (9,595 ± 5,795 vs. 8,279 ± 3,872 USD, P = 0.003) or without MARCE (9,890 ± 5,616 vs. 8,255 ± 3,859 USD, P < 0.001).
Conclusions
In patients with STEMI undergoing pPCI with iso-osmolar contrast, the incidence of AKI and MARCE was associated with higher hospitalization costs. Systolic blood pressure, hypertension, anterior wall infarction, Killip class, and SCr were identified as risk factors for these outcomes.
2.Expert consensus on the application of artificial intelligence in lung cancer screening, diagnosis, and treatment (2026 edition)
Wenzhao ZHONG ; Haibo WANG ; Yi HU ; Hao ZHANG ; Jigang DAI ; Junqiang FAN ; Guibin QIAO ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Zihao CHEN ; Hongxia TIAN ; Lunxu LIU ; Hecheng LI ; Xiaolong YAN ; Zongyang YU ; Zhenbin QIU ; Yihua SUN ; Jing HU ; Yuhang SHI ; Zhifei GUO ; Peng ZHANG ; Kezhong CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):848-856
With the continuous deepening of the concept of precision diagnosis and treatment for lung cancer, how to achieve higher efficiency and accuracy in the screening, diagnosis, and treatment pathways in clinical practice has become an important issue that urgently needs to be overcome. The current clinical difficulty lies in the fact that despite continuous advancements in imaging and molecular diagnostic technologies, there are still limitations in manual efficiency and subjective experience when it comes to massive data analysis and multi-scale feature extraction. Artificial intelligence (AI), especially algorithm systems based on deep learning, is an innovative technology capable of deeply empowering medical big data. This method utilizes algorithms such as convolutional neural networks, combined with radiomics, pathomics, and multi-modal data fusion analysis, demonstrating immense potential in early precise detection and benign-malignant differentiation of pulmonary nodules, digital pathological subtype recognition and non-invasive prediction of driver genes, precise 3D surgical planning and automatic delineation of radiotherapy target volumes, as well as dynamic risk warning during follow-up. This innovative technology provides a brand-new solution for realizing intelligent and individualized lung cancer diagnosis and treatment models. This consensus, based on the latest evidence from evidence-based medicine and combined with the development trends in the AI field and real-world clinical needs, was ultimately formed by gathering the consensus opinions of multidisciplinary experts in radiology, pathology, thoracic surgery, and other fields. The main content covers the application specifications of AI in the three core scenarios of lung cancer screening, diagnosis, and treatment, the technical standards for data collection and algorithm validation, as well as the ethical and regulatory challenges faced at the current stage. It aims to clarify the applicable boundaries of AI as a clinical auxiliary decision support tool, providing scientific guidance and standardized exploration directions for peers currently engaged in or planning to carry out AI-assisted clinical diagnosis, treatment, and translation of lung cancer.
3.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
4.Optimization Study of Rat Models for Sequelae of Pelvic Inflammatory Disease
Zhen LIU ; Wei-ling WANG ; Yun-cheng MA ; Yu-xi WANG ; Yuan TIAN ; Qian LI ; Xiao-zhu WANG ; Xiao-yao LIU ; Mei JIANG ; Wen-hui XU ; Jian GAO ; Ting WANG
Progress in Modern Biomedicine 2025;25(12):1921-1930
Objective:To establish a stable rat model of sequelae of pelvic inflammatory disease(SPID)with clinical characteristics,and to provide a reliable experimental model for the study of the pharmcological effect and mechanism of SPID.Methods:Twenty-four 7-week-old SD rats were divided into sham operation group,model-A(108 cfu/mL mixed bacterial solution,0.2 mL),model-B(109 cfu/mL mixed bacterial solution 0.2 mL),and model-C(108 cfu/mL E.coli 0.2 mL).The weight of the rat's uterine was weighed and the uterine index was calculated.The automatic hematology analyzer was used to detect the blood routine;hematoxylin-eosin staining(HE)and masson staining were used to detect uterine pathlogical changes in rats.Enzyme-linked immunosorbent assay(ELISA)was used to detect interleukin-1β(IL-1β),interleukin-6(IL-6)and tumor necrosis factor-α(TNF-α)in rat uterine tissue homogenates.Western blot was used to detect the expression of proteins related to NF-κB signaling pathway.Results:Compared with the sham operation group,the uterine index of model-A,model-B,and model-C were significantly increased(P<0.05,P<0.01).The levels of WBC and NE in the model-A increased significantly(P<0.01).The level of LY in model-B decreased significantly(P<0.01).The levels of IL-1β,TNF-α in model-A,model-B,and model-C were significantly increased(P<0.01).The levels of IL-6 in model-A and model-B were significantly increased(P<0.05,P<0.01).The collagen volume fraction of model-A and model-B were significantly increased(P<0.01).Mechanism study indicates that the expression levels of p-IKKβ/IKKβ,p-IκBα/IκBα and p-p65/p65 in model-A were significantly increased(P<0.01),and the expression levels of IκBα/β-actin were significantly decreased(P<0.01).The expression level of p-IKKβ/IKKβ in model-B was significantly increased(P<0.01).Conclusions:A stable rat model of SPID that conforms to clinical characteristics can be successfully constructed by combining 0.2 mL of mixed bacterial solution with a concentration of 108 cfu/mL and mechanical injury.This modeling method intervened in the expression of the NF-κB inflammatory signaling pathway.
5.Optimization Study of Rat Models for Sequelae of Pelvic Inflammatory Disease
Zhen LIU ; Wei-ling WANG ; Yun-cheng MA ; Yu-xi WANG ; Yuan TIAN ; Qian LI ; Xiao-zhu WANG ; Xiao-yao LIU ; Mei JIANG ; Wen-hui XU ; Jian GAO ; Ting WANG
Progress in Modern Biomedicine 2025;25(12):1921-1930
Objective:To establish a stable rat model of sequelae of pelvic inflammatory disease(SPID)with clinical characteristics,and to provide a reliable experimental model for the study of the pharmcological effect and mechanism of SPID.Methods:Twenty-four 7-week-old SD rats were divided into sham operation group,model-A(108 cfu/mL mixed bacterial solution,0.2 mL),model-B(109 cfu/mL mixed bacterial solution 0.2 mL),and model-C(108 cfu/mL E.coli 0.2 mL).The weight of the rat's uterine was weighed and the uterine index was calculated.The automatic hematology analyzer was used to detect the blood routine;hematoxylin-eosin staining(HE)and masson staining were used to detect uterine pathlogical changes in rats.Enzyme-linked immunosorbent assay(ELISA)was used to detect interleukin-1β(IL-1β),interleukin-6(IL-6)and tumor necrosis factor-α(TNF-α)in rat uterine tissue homogenates.Western blot was used to detect the expression of proteins related to NF-κB signaling pathway.Results:Compared with the sham operation group,the uterine index of model-A,model-B,and model-C were significantly increased(P<0.05,P<0.01).The levels of WBC and NE in the model-A increased significantly(P<0.01).The level of LY in model-B decreased significantly(P<0.01).The levels of IL-1β,TNF-α in model-A,model-B,and model-C were significantly increased(P<0.01).The levels of IL-6 in model-A and model-B were significantly increased(P<0.05,P<0.01).The collagen volume fraction of model-A and model-B were significantly increased(P<0.01).Mechanism study indicates that the expression levels of p-IKKβ/IKKβ,p-IκBα/IκBα and p-p65/p65 in model-A were significantly increased(P<0.01),and the expression levels of IκBα/β-actin were significantly decreased(P<0.01).The expression level of p-IKKβ/IKKβ in model-B was significantly increased(P<0.01).Conclusions:A stable rat model of SPID that conforms to clinical characteristics can be successfully constructed by combining 0.2 mL of mixed bacterial solution with a concentration of 108 cfu/mL and mechanical injury.This modeling method intervened in the expression of the NF-κB inflammatory signaling pathway.
6.Key technology and equipment development status of first-aid robotics
Zhen-bao WANG ; Zi-jian WANG ; Xin-xi XU ; Xin LIU ; Tao CHENG ; Pei-peng LIU ; Xiu-guo ZHAO ; Chen SU
Chinese Medical Equipment Journal 2025;46(3):96-114
The development status of the key technologies of first-aid robotics was introduced in autonomous system,embo-died intelligence,digital twins,large artificial intelligence model and autonomous unmanned medical treatment.The present situation in first-aid robotics equipment was reviewed for first-aid diagnosis,treatment,assistance and transportation.The development trends of the key technology and equipment of first-aid robotics were analyzed.It was pointed out the involve-ment of big model-based embodied intelligence technology and digital twins technology in first aid might provide new pers-pectives for the application and advancement of specialized first-aid robotics.[Chinese Medical Equipment Journal,2025,46(3):96-114]
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Effectiveness of three-dimensional-printed microporous titanium prostheses combined with flap implantation in treatment of large segmental infectious bone defects in limbs.
Yongqing XU ; Xinyu FAN ; Teng WANG ; Shaoquan PU ; Xingbo CAI ; Xiangwen SHI ; Wei LIN ; Xi YANG ; Jian LI ; Min LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):521-528
OBJECTIVE:
To analyze the effectiveness of single three-dimensional (3D)-printed microporous titanium prostheses and flap combined prostheses implantation in the treatment of large segmental infectious bone defects in limbs.
METHODS:
A retrospective analysis was conducted on the clinical data of 76 patients with large segmental infectious bone defects in limbs who were treated between January 2019 and February 2024 and met the selection criteria. Among them, 51 were male and 25 were female, with an age of (47.7±9.4) years. Of the 76 patients, 51 had no soft tissue defects (single prostheses group), while 25 had associated soft tissue defects (flap combined group). The single prostheses group included 28 cases of tibial bone defects, 11 cases of femoral defects, 5 cases of humeral defects, 4 cases of radial bone defects, and 3 cases of metacarpal, or carpal bone defects, with bone defect length ranging from 3.5 to 28.0 cm. The flap combined group included 3 cases of extensive dorsum of foot soft tissue defects combined with large segmental metatarsal bone defects, 19 cases of lower leg soft tissue defects combined with large segmental tibial bone defects, and 3 cases of hand and forearm soft tissue defects combined with metacarpal, carpal, or radial bone defects, with bone defect length ranging from 3.8 to 32.0 cm and soft tissue defect areas ranging from 8 cm×5 cm to 33 cm×10 cm. In the first stage, vancomycin-loaded bone cement was used to control infection, and flap repair was performed in the flap combined group. In the second stage, 3D-printed microporous titanium prostheses were implanted. Postoperative assessments were performed to evaluate infection control and bone integration, and pain release was evaluated using the visual analogue scale (VAS) score.
RESULTS:
All patients were followed up postoperatively, with an average follow-up time of (35.2±13.4) months. In the 61 lower limb injury patients, the time of standing, walk with crutches, and fully bear weight were (2.2±0.6), (3.9±1.1), and (5.4±1.1) months, respectively. The VAS score at 1 year postoperatively was significantly lower than preoperative one ( t=-10.678, P<0.001). At 1 year postoperatively, 69 patients (90.8%) showed no complication such as infection, fracture, prosthesis displacement, or breakage, and X-ray films indicated good integration at the prosthesis-bone interface. According to the Paley scoring system for the healing of infectious bone defects, the results were excellent in 37 cases, good in 29 cases, fair in 3 cases, and poor in 7 cases. In the single prostheses group, during the follow-up, there was 1 case each of femoral prostheses fracture, femoral infection, and tibial infection, with a treatment success rate of 94.1% (48/51). In lower limb injury patients, the time of fully bear weight was (5.0±1.0) months. In the flap combined group, during the follow-up, 1 case of tibial fixation prostheses screw fracture occurred, along with 2 cases of recurrent foot infection in diabetic patients and 1 case of tibial infection. The treatment success rate was 84.0% (21/25). The time of fully bear weight in lower limb injury patients was (5.8±1.2) months. The overall infection eradication rate for all patients was 93.4% (71/76).
CONCLUSION
The use of 3D-printed microporous titanium prostheses, either alone or in combination with flaps, for the treatment of large segmental infectious bone defects in the limbs results in good effectiveness with a low incidence of complications. It is a feasible strategy for the reconstruction of infectious bone defects.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Titanium
;
Retrospective Studies
;
Surgical Flaps
;
Adult
;
Prosthesis Implantation/methods*
;
Plastic Surgery Procedures/methods*
;
Treatment Outcome
;
Prostheses and Implants
;
Bone Diseases, Infectious/surgery*
;
Extremities/surgery*
;
Prosthesis Design

Result Analysis
Print
Save
E-mail