1.Chinese Materia Medica by Regulating Nrf2 Signaling Pathway in Prevention and Treatment of Ulcerative Colitis: A Review
Yasheng DENG ; Lanhua XI ; Yanping FAN ; Wenyue LI ; Tianwei LIANG ; Hui HUANG ; Shan LI ; Xian HUANG ; Chun YAO ; Guochu HUANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(1):321-330
Ulcerative colitis(UC) is a chronic non-specific inflammatory bowel disease characterized by inflammation and ulceration of the colonic mucosa and submucosa, and its complex pathogenesis involves immune abnormality, oxidative stress and other factors. The nuclear transcription factor E2-related factor 2(Nrf2), encoded by the Nfe212 gene, plays a central role in antioxidant responses. It not only activates various antioxidant response elements such as heme oxygenase-1(HO-1) and quinone oxidoreductase 1(NQO1), but also enhances the activity of glutathione-S-transferase(GST) and superoxide dismutase 1(SOD1), effectively eliminating reactive oxygen species(ROS) accumulated in the body, and mitigating oxidative stress-induced damage to intestinal mucosa. In addition, Nrf2 can reduce the release of inflammatory factors and infiltration of immune cells by regulating immune response, cell apoptosis and autophagy pathways, thereby alleviating intestinal inflammation and promoting the repair and regeneration of damaged mucosa. Based on this, this paper reviews the research progress of Chinese materia medica in the prevention and treatment of UC by modulating the Nrf2 signaling pathway. It deeply explores the physiological role of Nrf2, the molecular mechanism of activation, the protective effect in the pathological process of UC, and how active ingredients in Chinese materia medica regulate the Nrf2 signaling pathway through multiple pathways to exert their potential mechanisms. These studies have revealed in depth that Chinese materia medica can effectively combat oxidative stress by regulating the Nrf2 signaling pathway. It can also play a role in anti-inflammatory, promoting autophagy, inhibiting apoptosis, protecting the intestinal mucosal barrier, and promoting intestinal mucosal repair, providing new ideas and methods for the multi-faceted treatment of UC.
2.Chemical constituents from the stems and leaves of Dendrobium formosum and their biological activities
Li-hang CHI ; Hui-qin CHEN ; Sheng-zhuo HUANG ; Fei WU ; Wen-li MEI ; Xi-qiang SONG ; Hao-fu DAI
Chinese Traditional Patent Medicine 2025;47(2):467-473
AIM To study the chemical constituents from the stems and leaves of Dendrobium formosum Roxb.ex Lindl.and their biological activities.METHODS The 95%ethanol extract from the stems and leaves of D.formosum was isolated and purified by silica gel,Sephadex LH-20 and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.Their inhibitory activities onα-glucosidase were determined by PNPG method,and their in vitro anti-inflammatory activities were evaluated by RAW264.7 model.RESULTS Fifteen compounds were isolated and identified as coniferyl p-coumarate(1),(-)-pinoresinol(2),2,5,7-trihydroxy-4-methoxy-9,10-dihydrophenanthrene(3),naringenin(4),spiropreussomerin A(5),7-hydroxy-14-de-O-methyl-lasiodiplodin(6),(4S,5S,6Z,8E)-5-hydroxydeca-6,8-dien-4-olide(7),(6S,9R)-blumenol C(8),p-hydroxybenzoic acid(9),m-hydroxybenzoic acid(10),p-hydroxy benzenepropanoic acid(11),5,7-dihydroxy-isobenzofuran(12),2-(4-hydroxyphenyl)-ethanol(13),β-sitostenone(14),β-sitosterol(15).The IC50 values of compounds 1 and 4 on α-glucosidase inhibition were(65.60±3.31)and(98.95±2.53)μmol/L,respectively.Compound 3 presented inhibitory activity on NO production in RAW 264.7 cells,with IC50 value of(3.97±0.12)μmol/L.CONCLUSION Compounds 5-6,8 and 12 are isolated from Orchidacae family for the first time,and 2-15 are first isolated from this plant.Compounds 1 and 4 have α-glucosidase inhibitory activities,and 3 has anti-inflammatory activity.
3.Chemical constituents from the stems and leaves of Dendrobium formosum and their biological activities
Li-hang CHI ; Hui-qin CHEN ; Sheng-zhuo HUANG ; Fei WU ; Wen-li MEI ; Xi-qiang SONG ; Hao-fu DAI
Chinese Traditional Patent Medicine 2025;47(2):467-473
AIM To study the chemical constituents from the stems and leaves of Dendrobium formosum Roxb.ex Lindl.and their biological activities.METHODS The 95%ethanol extract from the stems and leaves of D.formosum was isolated and purified by silica gel,Sephadex LH-20 and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.Their inhibitory activities onα-glucosidase were determined by PNPG method,and their in vitro anti-inflammatory activities were evaluated by RAW264.7 model.RESULTS Fifteen compounds were isolated and identified as coniferyl p-coumarate(1),(-)-pinoresinol(2),2,5,7-trihydroxy-4-methoxy-9,10-dihydrophenanthrene(3),naringenin(4),spiropreussomerin A(5),7-hydroxy-14-de-O-methyl-lasiodiplodin(6),(4S,5S,6Z,8E)-5-hydroxydeca-6,8-dien-4-olide(7),(6S,9R)-blumenol C(8),p-hydroxybenzoic acid(9),m-hydroxybenzoic acid(10),p-hydroxy benzenepropanoic acid(11),5,7-dihydroxy-isobenzofuran(12),2-(4-hydroxyphenyl)-ethanol(13),β-sitostenone(14),β-sitosterol(15).The IC50 values of compounds 1 and 4 on α-glucosidase inhibition were(65.60±3.31)and(98.95±2.53)μmol/L,respectively.Compound 3 presented inhibitory activity on NO production in RAW 264.7 cells,with IC50 value of(3.97±0.12)μmol/L.CONCLUSION Compounds 5-6,8 and 12 are isolated from Orchidacae family for the first time,and 2-15 are first isolated from this plant.Compounds 1 and 4 have α-glucosidase inhibitory activities,and 3 has anti-inflammatory activity.
4.Epidemiological distribution characteristics and transmission patterns of Campylobacter in a Shandong broiler slaughterhouse
Shuai MIAO ; Xiu-mei HUANG ; Lin WANG ; Jun-hui LIU ; Jian-mei ZHAO ; Yu-bin GAO ; Shi-ping SONG ; Si-yu ZHANG ; Na LIU ; Ge ZHAO ; Xi-yue ZHANG ; Jun-wei WANG ; Juan WANG ; Zhi-na QU
Chinese Journal of Zoonoses 2025;41(6):583-591
This research investigated the contamination level,distribution of drug-resistant strains,and molecular epidemiologi-cal characteristics of Campylobacter,and further explored transmission pathways and prevention strategies.Cecum,chicken carcass,chicken product,and environmental samples,as well as swabs from workers'hands,were collected from a slaughterhouse in a large broiler group in the Jiaodong area between August 2023 and July 2024.Quantitative contamination assessment of Campylobacter in chicken carcasses and chicken products was performed.After microbial mass spectrometry identification,the representative strains of different links were selected for drug resistance testing and whole genome sequencing(WGS).On the basis of the sequencing results,the resistance genes,virulence genes,multilocus sequence typing(MLST),and phylogenetic characteristics of representative strains were analyzed.Homology comparisons were performed between isolates and strains from patients with diarrhea in the NCBI database.A total of 297 Campylobacter strains were isolated from 806 samples,and the overall detection rate was 36.85%.The detection rate of Campylobacter was highest in the evisceration process(47.33%),followed by the cutting process(35.64%).Overall,the Campylo-bacter detection rate first increased,then decreased,and subsequently increased.Drug sensitivity testing revealed that 90 isolates were resistant to nalidixic acid and ciprofloxacin,and 94.97%of isolates were resistant to tetracycline.WGS showed that both Campylo-bacter jejuni(C.jejuni)and Campylobacter coli(C.coli)carried many drug resistance and virulence genes.ST-14176 of C.jejuni was isolated for the first time herein.The predominant ST-8261 strain of C.jejuni and ST-860,ST-829,and ST-1586 strains of C.coli are known to cause human diarrhea.LOS expression genes associated with Guillain-Barré syndrome(GBS)were detected in both C.jejuni isolates from the slaughter chain and patients with GBS.Some strains exhibited close genetic relatedness to human-derived Campylo-bacter strains from the NCBI database.The detection rate of Campylobacter in the slaughterhouse first increased,then decreased,and subsequently increased,and the quantitative contamination level of each link was similar to the detection rate.Quantitative analysis of chicken carcasses/products revealed that the average bacterial load was highest in eviscerated carcasses(102.80 cfu/g),and the high-est amount of Campylobacter in chicken products reached 451.80 cfu/g.Abundant drug resistance genes and virulence genes were iden-tified,and the drug resistance genes were highly correlated with the drug resistance rate.Therefore,surveillance intensity and control measures for Campylobacter in slaughter processes should be strengthened.
5.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail