Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Multidisciplinary expert consensus on weight management for overweight and obese children and adolescents based on healthy lifestyle
HONG Ping, MA Yuguo, TAO Fangbiao, XU Yajun, ZHANG Qian, HU Liang, WEI Gaoxia, YANG Yuexin, QIAN Junwei, HOU Xiao, ZHANG Yimin, SUN Tingting, XI Bo, DONG Xiaosheng, MA Jun, SONG Yi, WANG Haijun, HE Gang, CHEN Runsen, LIU Jingmin, HUANG Zhijian, HU Guopeng, QIAN Jinghua, BAO Ke, LI Xuemei, ZHU Dan, FENG Junpeng, SHA Mo, Chinese Association for Student Nutrition & ; Health Promotion, Key Laboratory of Sports and Physical Fitness of the Ministry of Education,〖JZ〗 Engineering Research Center of Ministry of Education for Key Core Technical Integration System and Equipment,〖JZ〗 Key Laboratory of Exercise Rehabilitation Science of the Ministry of Education
Chinese Journal of School Health 2025;46(12):1673-1680
Abstract
In recent years, the prevalence of overweight and obesity among children and adolescents has risen rapidly, posing a serious threat to their physical and mental health. To provide scientific, systematic, and standardized weight management guidance for overweight and obese children and adolescents, the study focuses on the core concept of healthy lifestyle intervention, integrates multidisciplinary expert opinions and research findings,and proposes a comprehensive multidisciplinary intervention framework covering scientific exercise intervention, precise nutrition and diet, optimized sleep management, and standardized psychological support. It calls for the establishment of a multi agent collaborative management mechanism led by the government, implemented by families, fostered by schools, initiated by individuals, optimized by communities, reinforced by healthcare, and coordinated by multiple stakeholders. Emphasizing a child and adolescent centered approach, the consensus advocates for comprehensive, multi level, and personalized guidance strategies to promote the internalization and maintenance of a healthy lifestyle. It serves as a reference and provides recommendations for the effective prevention and control of overweight and obesity, and enhancing the health level of children and adolescents.
7.Synthesis and characterization of matrix metalloproteinase-responsive BDNF controlled-release materials
Jun-Ru HEI ; Cui WANG ; Meng-Wen SONG ; Sheng-Qiang XIE ; Bing-Xian WANG ; Xiao-Juan LAN ; Han-Bo ZHANG ; Gang CHENG ; Zhi-Qiang LIU ; Xi-Qin YANG ; Jian-Ning ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(11):1319-1326
Objective To develop a matrix metalloproteinase(MMP)-responsive hyaluronic acid(HA)-based controlled-release material for brain-derived neurotrophic factor(BDNF)to provide a novel therapeutic strategy for intervention and repair of traumatic brain injury(TBI).Methods HA was modified with amination,followed by condensation with Suflo-SMCC carboxyl group to form amide,and then linked with glutathione(GSH)to synthesize HA-GSH.The recombinant glutathione S-transferase(GST)-tissue inhibitor of metalloproteinase(TIMP)-BDNF(GST-TIMP-BDNF)expression plasmid was constructed using molecular cloning technique with double enzyme digestion by Bam H Ⅰ and Eco R Ⅰ.The recombinant GST-TIMP-BDNF protein was expressed in the Escherichia coli prokaryotic expression system,and purified by ion exchange chromatography,confirmed by Western blotting.MMP diluents were supplemented with PBS,MMP inhibitor marimastat,and varing concentrations(0.4,0.6,0.8 mg/ml)of GST-TIMP-BDNF or GST-BDNF.MMP-2 activity was analyzed using an MMP activity detection kit to evaluate the inhibitory effect of the recombinant protein on MMP.Primary rat neurons were extracted and cultured to establish an iron death model induced by RSL3.The effect of recombinant protein GST-TIMP-BDNF on neuronal injury was detected by immunofluorescence staining.Results MRI hydrogen spectrum identification confirmed the successful synthesis of HA-GSH.Western blotting results showed the successful expression of the recombinant protein GST-TIMP-BDNF containing the GST tag using the E.coli prokaryotic expression system.MMP activity detection results indicated that the recombinant protein GST-TIMP-BDNF had a superior inhibitory effect on MMP-2 activity compared to GST-BDNF(P<0.05).Immunofluorescence staining results showed a significant increase in fluorescence intensity in rat neurons treated with GST-TIMP-BDNF after RSL3 induction(P<0.05).Conclusion A MMP-responsive HA-based BDNF controlled-release material has been successfully developed,exhibiting a protective effect on neuron damage.
8.Current and predicted disease burden in middle aged and elderly population aged 55 years and above in Shenzhen, 2016-2030
Junyan XI ; Ruiqi MING ; Yijing WANG ; Yingbin FU ; Zhen ZHANG ; Jia ZHANG ; Jianjun BAI ; Yining XIANG ; Xiao LIN ; Jing GU ; Yuantao HAO ; Gang LIU
Chinese Journal of Epidemiology 2024;45(11):1550-1558
Objective:To analyze the disease burden in middle-aged and elderly population aged ≥55 in Shenzhen from 2016 to 2030 and provide evidence for the development of healthy aging strategies.Methods:The years of life lost (YLL), years lost due to disability (YLD), and the disability-adjusted life year (DALY) in this population from 2016 to 2022 were calculated. Joinpoint log-linear regression model was used to analyze the time trend. Bayesian age-period-cohort model and grey system model were used to predict YLL, YLD, and DALY in this population in 2030.Results:From 2016 to 2022, the crude DALY rate showed a transient fluctuation in age group 55-74 years, but a pronounced increase in age group ≥85 years. The proportions of YLL and YLD due to non-communicable diseases in all age groups was considerably higher than those due to communicable and nutritional diseases and injuries. In 2022, in all age groups, the YLL due to neoplasms (55-74 years old) and cardiovascular disease (≥75 years old) ranked first, and the YLD due to musculoskeletal disorder ranked first. By 2030, the causes of YLL and YLD ranking first in each age group would be remained, while the ranks of some causes would increase.Conclusions:The age specific characteristics of current and predicted disease burden differed in individuals aged ≥55 years. Therefore, it is necessary to allocate social and medical resources according to the disease burden pattern.
9.Chemical constituents of dichloromethane extract from the stems of Ephedra intermedia
Xi-ling FAN ; Yan-gang CAO ; Xiao-ke ZHENG ; Zhen-zhong WANG ; Wei XIAO ; Wei-sheng FENG
Acta Pharmaceutica Sinica 2024;59(9):2574-2580
Ten compounds were isolated and purified from the dichloromethane extract of stems of
10.Application of copy number variation sequencing in patients with intellectual disability/developmental delay and autistic spectrum disorder.
Jie LEI ; Gang ZHAO ; Yanke HUANG ; Min LONG ; Wei LI ; Xi DENG ; Zihan XIU ; Yanwei XIAO ; Sifan ZENG ; Jing ZHANG
Chinese Journal of Medical Genetics 2023;40(3):308-316
OBJECTIVE:
To assess the value of copy number variation sequencing (CNV-seq) for the diagnosis of children with intellectual disability (ID), developmental delay (DD), and autistic spectrum disorder (ASD).
METHODS:
Forty patients with ID/DD/ASD referred to Nanshan Maternity and Child Health Care Hospital from September 2018 to January 2022 were enrolled. G-banded karyotyping analysis was carried out for the patients. Genomic DNA was extracted from peripheral blood samples and subjected to CNV-Seq analysis to detect chromosome copy number variations (CNVs) in such patients. ClinVar, DECIPHER, OMIM and other database were searched for data annotation.
RESULTS:
Among the 40 patients (including 30 males and 10 females), 16, 15 and 6 were diagnosed with ID, DD and ASD, respectively. One patient had combined symptoms of ID and DD, whilst the remaining two had combined ID and ASD. Four patients were found with abnormal karyotypes, including 47,XY,+mar, 46,XY,inv(8)(p11.2q21.2), 46,XX,del(5)(p14) and 46,XX[76]/46,X,dup(X)(p21.1q12). Chromosome polymorphism was also found in two other patients. CNV-seq analysis has detected 32 CNVs in 20 patients (50.0%, 20/40). Pathogenic CNVs were found in 10 patients (25.0%), 15 CNVs of uncertain clinical significance were found in 12 patients (30.0%), and 7 likely benign CNVs were found in 4 patients (10.0%).
CONCLUSION
Chromosome CNVs play an important role in the pathogenesis of ID/DD/ASD. CNV-seq can detect chromosomal abnormalities including microdeletions and microduplications, which could provide a powerful tool for revealing the genetic etiology of ID/DD/ASD patients.
Pregnancy
;
Child
;
Male
;
Humans
;
Female
;
DNA Copy Number Variations
;
Intellectual Disability/genetics*
;
Autism Spectrum Disorder/genetics*
;
Developmental Disabilities/genetics*
;
Abnormal Karyotype


Result Analysis
Print
Save
E-mail